SlideShare une entreprise Scribd logo
1  sur  82
Télécharger pour lire hors ligne
MUX-2200E INTEGRATED SERVICE MULTIPLEXER


OPERATION AND MAINTENANCE MANUAL




     Wancom Communication and Network technology Ltd
           Copyright © 2010, All Rights Reserved
MUX-2200E - CONTENTS




                       -2-
MUX-2200E - CONTENTS




CONTENTS
DECLARATION......................................................................................................................... 3

COPYRIGHT AND TRADEMARK ............................................................................................ 3

VERSION HISTORY.................................................................................................................. 3

ABOUT THIS MANUAL ............................................................................................................ 3

   Intended Readers .................................................................................................................. 3
   Typographical Conventions ................................................................................................... 3
   Notes, Notices and Cautions ................................................................................................. 3
   Safty Instructions ................................................................................................................... 3

CHAPTER-1 INTRODUCTION ................................................................................................. 3

   1.1 Overview .......................................................................................................................... 3
   1.2 Features........................................................................................................................... 3
   1.3 Specifications ................................................................................................................... 3
   1.4 Physical Description ........................................................................................................ 3

CHAPTER-2 INSTALLATION ................................................................................................... 3

   2.1 Packing List...................................................................................................................... 3
   2.2 Unpacking ........................................................................................................................ 3
   2.3 Rack-free installation ....................................................................................................... 3
   2.4 Rack Installation............................................................................................................... 3
   2.5 Connect to Unit ................................................................................................................ 3
   2.6 Initial Power On and Checkout ........................................................................................ 3

CHAPTER-3 CONNECTOR PINOUTS..................................................................................... 3

   3.1 RJ45 Connectors (J1-J12)............................................................................................... 3
   3.2 V26 Connectors (CHN1-CHN6):...................................................................................... 3
   3.3 Serial M&C Port ............................................................................................................... 3

CHAPTER-4 MANAGEMENT................................................................................................... 3

   4.1 Through Front Panel ........................................................................................................ 3
   4.2 Through the M&C Port ..................................................................................................... 3
   4.3 Through Ethernet port...................................................................................................... 3

CHAPTER-5 CONFIGURATION............................................................................................... 3

   5.1 Unit Management ............................................................................................................ 3
   5.2 Trunk Management.......................................................................................................... 3
   5.3 Serial Port Management .................................................................................................. 3
   5.4 Voice Port Management .................................................................................................. 3
   5.5 E1 Port Management....................................................................................................... 3


                                                                  -3-
MUX-2200E - CONTENTS

   5.6 Utility ................................................................................................................................ 3
   5.7 Status ............................................................................................................................... 3

CHAPTER-6 MAINTENANCE .................................................................................................. 3

   6.1 Disassemble the Major Components............................................................................... 3
   6.2 Clean the Chassis............................................................................................................ 3
   6.3 Replace the Functional Boards........................................................................................ 3
   6.4 Upgrade the Firmware ..................................................................................................... 3

ANNEX-1 CLI COMMAND........................................................................................................ 3

   A1.1 Basic Command Formats.............................................................................................. 3
   A1.2 CLI Command Set......................................................................................................... 3

ANNEX-2 CONTROL MENU..................................................................................................... 3

ANNEX-3 CABLES ................................................................................................................... 3

   A3.1 RS530 DTE SMART SERIAL Cable.............................................................................. 3
   A3.2 RS530 DCE SMART SERIAL Cable ............................................................................. 3
   A3.3 RS232 DCE SMART SERIAL Cable ............................................................................. 3
   A3.4 Serial M&C Cable .......................................................................................................... 3




                                                                    -4-
MUX-2200E - FIGURES




FIGURES
  Figure 1-1. MUX-2200E Integration Service Multiplexer ....................................3
  Figure 1-2. Block Diagram ....................................................................................3
  Figure 1-4. Indicators on the front panel ...............................................................3
  Figure 1-5. Keypad ................................................................................................3
  Figure 1-6. LCD display ........................................................................................3
  Figure 1-8. Data interface ......................................................................................3
  Figure 1-9. Internal structure .................................................................................3
  Figure 1-10. System Motherboard .........................................................................3
  Figure 1-11. CPU module ......................................................................................3
  Figure 1-12. 4-way voice processing module (FXO/Blue)....................................3
  Figure 1-13. 4-way voice processing module (FXS/Black)...................................3
  Figure 1-14. 4E1 processing module .....................................................................3
  Figure 2-1. Status indicators as initial Power On...................................................3
  Figure 3-1. The RJ-45 socket.................................................................................3
  Figure 3-2. The V26 socket....................................................................................3
  Figure 6-1. Disassembling diagram of the top cover of the chassis ......................3
  Figure 6-2. Disassembling diagram for the functional modules............................3
  Figure 6-3. Installation diagram for the functional modules .................................3
  Figure 6-4. Disassembling diagram for the motherboard ......................................3
  Figure 6-5. Installation diagram for the motherboard............................................3
  Figure 6-6. Software upgrade program interface...................................................3
  Figure 6-7. The upgrade program screen – unit scan process................................3
  Figure 6-8. The upgrade program screen - uploading process...............................3




                                                     -5-
MUX-2200E - TABLES




TABLES
   Table 1-1 Indicator list of the front panel ..............................................................3
   Table 1-2 Data port list of the rear panel ...............................................................3
   Table 3-1. Defintion of the FXO/FXS voice port ..................................................3
   Table 3-2. Definition of the E&M voice port.........................................................3
   Table 3-3. Definition of the E1/T1 port .................................................................3
   Table 3-4. Definition of the Ethernet port..............................................................3
   Table 3-5. Definition of the RS-232 interface........................................................3
   Table 3-6. Definition of the RS-449 interface........................................................3
   Table 3-7. Definition of the V.35 interface ............................................................3
   Table 3-8. Definition of the X.21 interface............................................................3
   Table 3-9. Definition of the RS-530 interface........................................................3
   Table 3-10. Definition of the interface of the serial M&C port .............................3
   Table 4-1. Definitions of buttons on the front panel ..............................................3
   Table 5-1 System clock source...............................................................................3
   Table 6-1. Field Maintenance Record Sheet ..........................................................3
   Table 7-1. Port number correspondence table........................................................3
   Table 9-1. Definition of the V26 (DTE) converter cable .......................................3
   Table 9-2. Definition of the V26 (DCE) converter cable.......................................3
   Table 9-3. Definition of the V26 (RS232/DCE) converter cable...........................3
   Table 9-4. Definition of the serial M&C cable ......................................................3




                                                   -6-
MUX-2200E - DECLARATION




DECLARATION
 Thank you for selecting the multiplexer products of Wancom Communication and
 Network Technology Ltd (hereinafter referred to as “Wancom”).
 The manual will help you use Wancom Integrated Service Multiplexer products
 (hereinafter referred to as the “Product” or the “Device”). Be sure to read all data
 supplied with the Device carefully before installing and using the Product for the
 first time, especially cautions mentioned in the manual. This will help you use the
 Product in a better and safer way. Keep the manual appropriately for future
 reference.
 The manual does not represent any description to the specifications, software and
 hardware configurations of the Product. Refer to related agreements, packing lists
 and product specification and configuration description documents or consult the
 distributor of the Product for actual specifications and configurations related to the
 Product.
 Wancom will not be liable for any damage incurred if the user fails to install, use or
 maintain the product correctly or according to the instructions and requirements of
 the product or technicians not authorized by Wancom are allowed to repair or
 modify the Product.
 Pictures, figures, graphics and illustrations contained in the manual are only used
 for explanation and illustration purposes and may different slightly from the real
 product. Moreover, the actual product specifications and configurations are subject
 to change according to the demands. The product specifications and configurations
 are subject to the actual products.
 The manual does not mean that Wancom has made any warranty regarding its
 products and services, either express or implied, including but not limited to
 warranties of applicability, safety, merchantability and fitness for a particular
 purpose for products recommended in the manual. The warranty commitments for
 the product and related services shall be subject to the applicable agreement or the
 service terms and conditions of the product standards. In no event shall Wancom be
 liable for any damage including but not limited to direct or indirect personal
 damage, business profit loss, business interruption, business data loss or any other
 losses incurred thereof during your use or failure to use the Product within the
 maximum allowable range of laws and regulations.
 Though we have checked and verified the manual carefully, we do not guarantee
 that the manual is free from any error or omission. To offer better services, we may
 improve or modify product software and hardware described and contents
 contained herein from time to time without notice. Contact us if you find any
 difference between the actual conditions of the product and the manual during use
 or you want to acquire the latest information or have any questions and ideas.



                                        -7-
MUX-2200E - COPYRIGHT AND TRADEMARK




COPYRIGHT AND TRADEMARK
  Wancom mentioned herein is the trademark of Wancom Communication and
  Network Technology Ltd. Other trademarks and product names mentioned herein
  are also owned by the original owner of the trademark.
  The manual is protected by copyright laws and regulations. No person is allowed to
  duplicate, copy or delete the manual in whole or in part by any means or compile it
  into computer readable format or save it in the retrievable system or transmit it in a
  cable or wireless network in any form or translate it into any language.




                                         -8-
MUX-2200E - VERSION HISTORY




VERSION HISTORY
Version   Version description              Compiled by   Compiled on
1.0       Original version (applicable for Poppy         2010-08-25
          MUX-2200E V1.0)
1.1       Update ”3.1.1.2 E&M Interface”   Poppy         2010-10-26




                                 -9-
MUX-2200E - VERSION HISTORY

                 This page is intentionally left blank.




                                 - 10 -
MUX-2200E - ABOUT THIS MANUAL




ABOUT THIS MANUAL
This manual consists of the following Chapters:
     Chapter 1: INTRODUCTION - Brief the hardware of the MUX-2200E and its
     features
     Chapter 2: INSTALLATION - Instruct users to install the MUX-2200E
     Chapter 3: CONNECTOR PINOUTS - Describe the definitions of various ports
     on the front and rear panel
     Chapter 4: MANAGEMENT - Instruct users to configure and manage the
     MUX-2200E via the front panel, the monitored port and the Ethernet
     Chapter 5: CONFIGURATION – Describe the menu operations of the front panel
     Chapter 6: MAINTENANCE - Instruct users to do routine device maintenance
     Annex 1: CLI COMMANDS - Provide complete CLI command set.
     Annex 2: CONTROL MENU - Provide tree-like menu list.
     Annex 3: CABLES - Describe the definition of the supporting cables for the device


Intended Readers

This manual contains information useful for setup and management of the MUX-2200E
integration service multiplexer. This manual is intended for telecommunication
engineers familiar with system installation and network management concepts and
terminology.


Typographical Conventions

Convention            Description
Bold font             It indicates the button of the software interface as well as menu
                      and menu item. For example, click the Start button to select the
                      Run command.
[]                    [ ] represents a command option in the command line mode. Such
                      as <1/TXDR_port number_ [rate], if the command contains
                      the rate value, it means to set the TX data rate of the specified
                      port; if not, it means to inquire about the TX data rate of the
                      specified port.
Menu Name             Menu Name►Menu Option indicates the menu structure for
►Menu Option          the operations on the front panel or the software interface, such as
                      selecting UNIT►DATE command on the front panel, means the
                      DATE menu option under the UNIT menu that is located under
                      the device menu.

                                         - 11 -
MUX-2200E - ABOUT THIS MANUAL

Lucida Console        The words in this font indicates input command and information
Font                  feedback by the equipment under the command line mode, of
                      which, the underline represents the keypad command input
                      while italics denotes information feedback from the
                      equipment.



Notes, Notices and Cautions

To avoid personal injury and property loss, read and follow the following safety
precautions carefully before installing this product. The following safety signs will be
used in the document or on the product and product package. Safety signs are illustrated
as follows:


                    A Note explains some important information, helping you use your
                    equipment in a better way.

                    A Notice indicates potential hazards which may result in hardware
                    damage or data loss and tell you how to avoid such problems.

                    A Caution indicates the potential hazards which may result in
                    property loss, personal injury or even death.




                                         - 12 -
MUX-2200E - ABOUT THIS MANUAL




Safty Instructions

Follow these safety guidelines to ensure personal safety and help protect your system
from potential damage.


Safety Cautions

To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment,
obverve the following precautions.
   Read the operation labels and follow the instructions of the labels.
   Do not carry out operations not described in any document of the product.
   Disassembling the chassis may result in electric shock.
   Only properly-trained maintenance technicians can handle the assemblies in the
   chassis.
   Power off the product and contact your training service provider in case of one of
   the following circumstances:
   The power cord, extension wire or plug is damaged.
   Unknown objects in the chassis
   The chassis is wet.
   Falling from a high position may result in product damage.
   Keep your system far away from the heat source and the radiator.
   Do not block the cooling vent.
   Do not drop food or liquid into the chassis.
   Do not operate the device in a wet environment.
   Do not attempt to squeeze any object into the opening of the chassis, which may
   result in a fire or electric shock incurred by short circuit of internal components.
   Use devices from proper channels only.
   Wait until the device is cooled properly before removing the cover or touching
   components inside the chassis.
   Guarantee that the power source type and power supply cable conform to the
   product requirements.
   To prevent electric shock, insert a properly-grounded power outlet system and
   external power cord. Such cables have three-pin plugs to help guarantee appropriate
   grounding. Don’t use a plug adaptor or grounding pin with broken power cords. Use
   three-wire cables with proper grounding plugs if extension wires must be used.
   Check the capacity of the extension wire and the distribution panel to ensure the
   total current of all products does not exceed 80% of the nominal current of the
   extension cord or the power panel.
   Use UPS to prevent sudden and transient increase and decrease of the power
   system.

                                         - 13 -
MUX-2200E - ABOUT THIS MANUAL

   Ensure firm power cable binding to prevent system cables or power cable from
   being short-circuited or broken and prevent it from being stepped on or tripped over.
   Do not change the power cord or plug.



General Precautions for Rack-Mounted Products

   If the rack itself is not stable before installing the device, it may result in personal
   injury. Therefore, install the supporting assembly inside the rack to ensure that the
   rack is firm. If a sliding track or tray is available, install the sliding track assembly
   or tray on the rack first. Ensure that the sliding track and tray can support the device
   properly.
   Ensure the rack has been mounted on the floor properly before the rack is installed.
   Use connectors if there are other racks near it.
   Always install the loads inside the rack from the bottom up; the heaviest load shall
   be installed at the bottom of the rack.
   The AC or DC power supply provided for the rack shall have enough load capacity.
   The total load of the devices on the rack shall not exceed 80% of the rated load of
   the power supply system.
   Ensure the airflow in the rack is unobstructed to facilitate heat elimination of the
   devices on the rack.
   Don’t step or stand on any assembly when maintaining other parts.

                    Don’t operate the devices under non-grounding or
                    poorly-grounded conditions. Contact the electrician if the
                    grounding condition is unclear.


Protecting against Electrostatic Discharge

Electrostatic may damage some sensitive parts inside your system. To prevent
electrostatic damage, remove the electrostatic from your body first before touching
electronic products, such as the electronic assembly of the micro-processor. You may
also touch uncoated metal surfaces on a regular basis to remove electrostatic. In
addition, you may take the following measures to prevent ESD damage:
   Do not take electrostatic sensitive equipments from anti-static packaging material
   after taking them out of the transport package until you are ready to install them into
   the components of your system. Be sure to discharge the electrostatic of your body
   thoroughly before removing the anti-static package.
   Place electrostatic sensitive equipment into anti-static container or package first for
   packing when transporting such sensitive equipment.
   Handle sensitive parts within the electrostatic safe area. Use an anti-static floor mat,
   anti-static workbench mattress and grounding strap if possible.

                                          - 14 -
MUX-2200E - CHAPTER-1 INTRODUCTION




CHAPTER-1 INTRODUCTION
This Chapter gives a brief introduction to the product characteristics, system
specification and function features of the MUX-2200E integrated service multiplexer
(hereinafter referred to as the “Multiplexer” or the “Equipment”) to help you to have a
general understanding of the multiplexer.


1.1 Overview

The MUX-2200E is a high-quality integrated service multiplexer product with super
system performance launched in 2010 on the basis of the original MUX-2200D
integrated service multiplexer, which is specially developed for enterprise and industry
users.
The MUX-2200E is an integrated multiplexer platform oriented to telecommunication,
public security and frontier defenses, bank and finance as well as enterprise application.
It supports compressing serial data, voice and IP services into high speed data streams,
realizes duplex transmission via communication links such as DDN, microwave and
satellite etc, which simplifies the network structure of the communication system and
improves the system stability.




                 Figure 1-1. MUX-2200E Integration Service Multiplexer

Two versions of the MUX-2200E are available at present, the V1.0 is fully compatible
with MUX-2200D, while V2.0 shall provide more expandable capacity. Therefore,
users may customize the required one according to their own demand.


1.2 Features

High availability

The MUX-2200E adopts TDM technology to support converting serial data, voice and
IP businesses into high speed data streams, which are transmitted duplex via

                                          - 15 -
MUX-2200E - CHAPTER-1 INTRODUCTION

communication links such as DDN, microwaves and satellites. The transmission is
stable with less signal delay.
The MUX-2200E provides EIA-232/EIA-422/V.35/G.703/E1 interface, Analog voice
and Ethernet, which can support a variety of data, voice or video services; support the
trunk data rate up to 20Mbps.
The MUX-2200E V1.0 with standard configurations are fully compatible with
MUX2200D.




                              Figure 1-2. Block Diagram


High reliability

The MUX-2200E is configured with two trunk ports with 1: 1 redundant backup. Two
hardware ports adopt independent data processing chips. If one trunk port fails or is
damaged, the other one may be used.

High expansibility

The MUX-2200E adopts modular design, which takes into account the expansion
requirement from the beginning of the design. Through simple hardware upgrading and
functional module replacement, it can be expanded up to eight voice channels or eight
E1 channels, two groups of independent network connection, and video expansion.

High manageability

Users may configure and monitor MUX-2200 through the front panel, serial M&C port
and Ethernet port. The firmware version may be updated via the serial M&C port or
Ethernet port conveniently and rapidly.



                                        - 16 -
MUX-2200E - CHAPTER-1 INTRODUCTION


1.3 Specifications

Trunk port
    Interface:   EIA-422/EIA-232/V.35/LVDS
    Type:        V26 with DB25 converter cable
    Data rate:   9.6kbps to 20Mbps synchronous (step by 100bps)
    Quantity:    2 ports, adopting 1:1 redundant configuration

Serial port
    Interface: EIA-422/EIA-232/V.35/LVDS
    Type:       V26 with DB25 converter cable
    Data rate: 1.2kbps -10Mbps synchronous (step by 100bps) or 300bps
--115.2kbps asynchronous
    Quantity: 4

E1 port
    Interface:   G.703 /G.704
    Type:        RJ45
    Data rate:   64Kpbs × n (n≤32)
    Quantity:    4 (Support up to 8 ports optionally)

Voice port
    Interface: FXS, FXO and E&M
    Type:        RJ45
    Data rate and Protocol:
         Coding:            G.711 (64k), G.723.1 (5.3k/6.3k)
         Echo cancellation: G.168
    Quantity: 4 (Support up to eight ports optionally)

Ethernet port
    Interface:   IEEE802.3
    Type:        RJ45
    Data rate:   10/100M
    Quantity:    2 groups, 2 ports available for each group (Support up to 4 ports each
group)

Expansion slot
    Expandable video port

M&C
    Provide the M&C port to facilitate monitor and control
    Provide CLI and Telnet management interface.

                                        - 17 -
MUX-2200E - CHAPTER-1 INTRODUCTION


Operation method and status display
    6-key keypad on the front panel with LCD
    Monitor and control via serial M&C port
    Monitor and control via Ethernet port
    Status indicator
        TX and RX Indication for Trunk port
        Synchronous status indication for Trunk port
        TX and RX Indication for serial ports
        Connection status for Ethernet ports
        Synchronous and carrier indication for E1 ports
        Off-hook or ringing indication for analog voice interface

Environments
    Operating temperature:    0℃ ~ +60℃
    Operating humidity:       0 ~ 90%
    Storage temperature:      -40℃ ~ +70℃

Power supply
    Working voltage:          85V ~ 240V AC, -48V DC (optional)
    Consumption:              less than 25W

Physical specification
    Net weight:               3.1 kg
    Dimension(W×D×H):         482mm×355mm×44mm


1.4 Physical Description

This part gives a brief introduction to the appearance and internal structure of the
MUX-2200E chassis. Refer to Chapter-6 MAINTENANCE contained herein for
related product installation and disassembling contents.
                   All pictures contained in this part are for reference only. Specific
                   products are subject to the real objects.


1.4.1 Outline Structure

The MUX-2200E integration service multiplexer is constructed as a 1RU-high rack
mounting chasiss, which can be free-standing if desired. Rack handles at the front
facilitate removal from and placement into a rack.




                                        - 18 -
MUX-2200E - CHAPTER-1 INTRODUCTION


1.4.1.1 Front Panel




                             Figure 1-3. Front Panel View
Figure 1-3 shows the front panel of the MUX-2200E. The front panel features (from left)
the following components:
   Serial M&C port
   Light-Emitting-Diode(LED) indicators
   Keypad
   Liquid-Crystal-Display(LCD)
   Power switch

- Indicators




                        Figure 1-4. Indicators on the front panel

The front panel of the MUX-2200E includes the following indicators:

 Indicator      Color    Function description
 PWR            Green    Always on, indicating the power supply works normally.
 TX             Green    Always on or flickering, indicating the trunk port is
                         transmitting data
 RX             Green    Always on or flickering, indicating the trunk port is
                         receiving data
 SYNC           Green    Always on, indicating the trunk is receiving data normally.
 DS             Red      Red light always on indicates the unit is starting during
                         start-up.
                         Red light always on or flickering indicates the unit works
                         abnormally after start-up is completed.
 TX1-TX8        Green    On or flickering indicates the serial port CH1 is transmitting
                         data
 RX1-RX8        Green    On or flickering indicates the serial port CH1 is receiving
                         data
                        Table 1-1 Indicator list of the front panel




                                          - 19 -
MUX-2200E - CHAPTER-1 INTRODUCTION

- Keypad

The MUX-2200E adopts 6-key layout, including the , , and direction keys as
well as the ENTER key for confirmation and the CLEAR key for cancel or return.




                                  Figure 1-5. Keypad

- LCD

The LCD of the front panel of the MUX-2200E is an active showing two lines of
20-character each, and produces a yellow green backlight. “▲” is used to prompt the
current menu items or edit position.



                                Figure 1-6. LCD display


1.4.1.2 Rear Panel




                              Figure 1-7. Rear Panel View
Figure 1-7 shows the the following components:
   Power interface and fuse
   Expansion slot
   RJ45 ports
   V26 serial ports
   Ground pole

- Data Interface




                               Figure 1-8. Data interface

Figure 1-8 shows the connectors installed in the rear panel of the MUX-2200E. Each

                                         - 20 -
MUX-2200E - CHAPTER-1 INTRODUCTION

connector is described in detail in Chapter-3 “CONNECTOR PINOUTS”. Extenal
cables are attached to these connectors.
                  A hardware port of the same type as RJ45 on the rear panel may be
                  set as different service type by changing the functional module
                  board inside the chassis.

 Connnector Name       Default            Optional             Remarks
 V26 port   CHN5       Online trunk       Standby trunk        Only one online trunk
            CHN6       Standby trunk      Online trunk         port can be selected
            CHN1       Serial Data
            CHN2       Serial Data                             If LAN2 enabled,
                                                               CHN2 will be off
                                                               automatically
              CHN3     Serial Data
              CHN4     Serial Data
 RJ45 port    J1-J4    Voice              E1                  Need      to   replace
              J5-J8    E1                 Voice/Ethernet      functional     module
                                                              boards
              J9/J11 LAN Group1                               Default ON
              J10/J12 LAN Group2                              Default OFF.
                      Table 1-2 Data port list of the rear panel


1.4.2 Internal Structure




                           Figure 1-9. Internal structure

The MUX-2200E adopts modular design. The chassis mainly contains the following
components.
   E1 Processing Module;
   Voice Processing Module;

                                        - 21 -
MUX-2200E - CHAPTER-1 INTRODUCTION

   CPU Module;
   System Motherboard;
   Keypad and Display Module;
   Power Supply Module;
   Ventilating Fan;
   M&C Interface Module


1.4.2.1 Keypad and Display Module

The Keypad and Display Module consists of a keypad input interface circuit, a drive
circuit for LCD and indicators. Any keypad operation will be sent to the system
motherboard via the module while feedback message from the system will be displayed
on the LCD through the module, as well as affect the status of the indicators.


1.4.2.2 System Motherboard

The system motherboard is the core component of the MUX-2200E, which has the
following functions:
   Provide Wiring and logic connections of other modules inside the chassis;
   Provide FPGA to achieve a multiplexing function;
   Provide interface circuits for all input and output ports;
   Provide all input and output connectors on the rear panel, including 6 V26 ports and
   12 RJ45 ports;
   Provide sockets for all sub-function modules, including CPU module socket and
   functional module sockets;
   Provide Ethernet bridge and switching circuit;




                          Figure 1-10. System Motherboard
             (with CPU module, 4E1 module and 4-way voice module)


                                        - 22 -
MUX-2200E - CHAPTER-1 INTRODUCTION


1.4.2.3 Common Functional Modules

- CPU Module




                               Figure 1-11. CPU module



- Voice Processing Module

The voice processing module is responsible for voice compression to achieve FXO,
FXS and E&M analog voice interface functions, provide reliable lightning prevention
and anti-static protection.
The analog voice signal line provides 180V of overvoltage protection and 90mA
over-current protection (the breakdown voltage is more than 250V). Each interface
provides two indicators, which are driven by CPU. Functions of the following lights are
shown below:
   Yellow: Glittering, indicating ringing signals
   Green: Always on, indicating the telephone is in use.
The voice processing module is classified as 2 kinds, which support FXO interface and
FXS interface respectively.




                Figure 1-12. 4-way voice processing module (FXO/Blue)




               Figure 1-13. 4-way voice processing module (FXS/Black)


                                        - 23 -
MUX-2200E - CHAPTER-1 INTRODUCTION

- E1 Processing Module

The E1 processing module is responsible for E1/T1 interface functions, providing
lightning and anti-static protection. Provide 6V over-voltage protection and 90mA
over-current protection (the breakdown voltage exceeds 250V). Each interface provides
two indicators (built in RJ45 interface), which are driven by the CPU board. Lights are
defined as follows:
   Yellow: Flickering or always on indicates the carrier is losing lock.
   Green: If the light is on, it indicates the frame has been synchronous.




                          Figure 1-14. 4E1 processing module




                                         - 24 -
MUX-2200E - CHAPTER-2 INSTALLATION




CHAPTER-2 INSTALLATION
This Chapter introduces the installation, cable connection and power-on procedure.


2.1 Packing List

The standard MUX-2200E packing box contains the following items:
   MUX-2200E chassis ;
   AC power cord ;
   Two V26 interface converter cable;
   One serial M&C cable;
   Operation and Maintenance Manual (CD-ROM);


2.2 Unpacking

   Check the appearance of the packing box carefully to ensure the original package of
   the equipment is neither worn nor damaged and free from water and foreign objects.
   Place the packing box on a stable plane at the correct position.
   Uncover the upper transparent tape sealing of the packing box with a paper knife.
   Take out the equipment together with the anti-shock foamed plastic.
   Take out the equipment from the anti-static packing bag.
   Check whether all items are complete carefully with reference to the packing list
   contained in this Chapter and have an appearance inspection to ensure the
   equipment and parts are free from any damage.
   Keep the original packing box and the packing materials in the box temporarily,
   which may be used for equipment transport and packing once again.

                    Contact the distributor to make up the deficiency in case of any
                    shortage of the above contents in the open-case inspection.



2.3 Rack-free installation

   Tear off the protective film outside the chassis.
   Place the equipment at the selected installation position.
   Connect the power cord and other signal cables.
   Ensure that the equipment is properly grounded.



                                         - 25 -
MUX-2200E - CHAPTER-2 INSTALLATION

                    More than 20cm of distance must be provided at the left side (air
                    inlet) and the right side (exhaust outlet) of the chassis for heat
                    radiation. At least 50cm of distance must be provided at the back
                    side of the chassis to facilitate feeder connection and maintenance;
                    moreover, not less than 50cm of distance must be provided at the
                    front side of the chassis to facilitate the operations of the front
                    panel.

                    If the equipment is installed in a room without an air purification
                    and filter system or non-professional communication room, the
                    chassis is recommended to be installed 1 meter above the ground to
                    prevent dust and foreign objects from being absorbed into the
                    chassis after long-term operation.

                    Equipment shall not be stacked exceed 2 layers, and the overall
                    bearing of the top cover of the equipment shall not exceed 10kg.
                    Ensure the surface of the cabinet, table or support of the equipment
                    placed are flat and the overall support is stable; the overall weight
                    of all equipments shall not exceed 50% of the bearing of the
                    cabinet, the table or the support.



2.4 Rack Installation

   Install the tray or bracket at the required rack position.
   Tear off the protective film outside the chassis.
   Place the equipment on the rack tray and fasten the front panel.
   Connect the power cord and other signal cables.
   Connect the grounding line to the equipment from the grounding copper bar of the
   cabinet.

                    It is recommended that the equipment be installed with a 1U space
                    in the rack. If the equipment does need to be stacked, it shall not
                    exceed 2 layers.


2.5 Connect to Unit

The MUX-2200E may need to use the following (partial) cables:
   Power cord
   Grounding wire
   Serial cable for Trunk port (including V26 converter cables)
   Serial cables for serial port (including V26 converter cable, if required)

                                         - 26 -
MUX-2200E - CHAPTER-2 INSTALLATION

  Telephone line
  E1 line
  LAN Cable
  Serial M&C cable

                  The V26 converter cables, serial M&C cable and power cord are
                  standard configurations with MUX-2200E. Other cables shall be
                  fabricated on the field by users or professional installation
                  personnel. Refer to Chapter-3 “CONNECTOR PINOUTS” for
                  specific port definitions.


2.6 Initial Power On and Checkout

                  Read and follow all precautions mentioned in the safety
                  instructions. Ensure the MUX-2200E has been installed in line
                  with the prompts of this section and complete cable connection
                  work.

  Turn on the power switch on the front panel; the following information will be
  displayed as follows:


  Wait for the equipment to complete the power-on self-check. The following
  information will be displayed on the LCD:


  The status indicators of the front panel show below before the equipment has not
  been configured:




                 Figure 2-1. Status indicators as initial Power On




                                      - 27 -
MUX-2200E - CHAPTER-2 INSTALLATION

                 This page is intentionally left blank.




                                 - 28 -
MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS




CHAPTER-3 CONNECTOR PINOUTS

3.1 RJ45 Connectors (J1-J12)




                             Figure 3-1. The RJ-45 socket

J1-12 on the rear panel may be configured as the voice, E1/T1 or Ethernet ports
according to different functional modules installed inside the chassis.


3.1.1 Analog Voice Ports

J1-J4 are default analog voice ports and J5-J8 may also be configured as analog voice
ports after installing appropriate functional module.


3.1.1.1 FXO/FXS Interface

                          Pin         Signal name
                          4           TIP
                          5           RING
                    Table 3-1. Defintion of the FXO/FXS voice port


3.1.1.2 E&M Interface

              Pin         Signal name             Signal direction
              1           SG                      Input
              2           E                       Input
              3           RR                      Input
              4           Ring                    Output
              5           TIP                     Output
              6           TR                      Input
              7           M                       Output
              8           SB                      Output
                      Table 3-2. Definition of the E&M voice port

                                        - 29 -
MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS


3.1.2 E1/T1 Interface

J5-J8 are default E1/T1 ports and J1-J4 may also be configured as E1/T1 ports after
necessary functional modules are installed. The pin assignment is defined as follows:


                 Pin         Signal name           Signal direction
                 1           RX_TIP                Input
                 2           RX_RING               Input
                 4           TX_TIP                Output
                 5           TX_RING               Output
                        Table 3-3. Definition of the E1/T1 port


3.1.3 Ethernet Interface

J5-J12 may be configured as Ethernet ports, of which J5, J7, J9 and J11 belong to LAN1
and J6, J8, J10 and J12 belong to LAN2. LAN1 and LAN2 are separated from each
other. Only J9 and J11 are active under the default condition. The pin assignment is
defined as follows:

                 Pin         Signal name           Signal direction
                 1           RX+                   Input
                 2           RX-                   Input
                 3           TX+                   Output
                 6           TX-                   Output
                       Table 3-4. Definition of the Ethernet port


3.2 V26 Connectors (CHN1-CHN6):




                              Figure 3-2. The V26 socket

The ports (CHN1-CHN6) on the rear panel are serial ports, 4 ports (CHN1-CHN4) are
serial data ports, 2 ports (CHN5 and CHN6) are trunk ports. The pin assignment is
defined as follows.
                                         - 30 -
MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS



               All undefined pins must be kept floating


3.2.1 RS-232 Interface

             Pin          Signal name             Signal direction
             21           TXD                     Output
             22           TXCE                    Output
             23           TXC                     Input
             24           RXC                     Input
             13           RXD                     Input
             6            DCD                     Input
             7            DTR                     Output
             8            RTS                     Output
             11           CTS                     Input
             12           DSR                     Input
             26           GND                     --
                   Table 3-5. Definition of the RS-232 interface


3.2.2 RS-449 Interface

             Pin          Signal name             Signal direction
             1            TXDa                    Output
             2            TXCEa                   Output
             3            TXCa                    Input
             4            RXCa                    Input
             5            RXDa                    Input
             6            DCDa                    Input
             7            DTRa                    Output
             8            RTSa                    Output
             9            RTSb
             10           CTSb
             11           CTSa                    Input
             12           DSRa                    Input
             14           TXDb                    Output
             15           TXCEb                   Output
             16           TXCb                    Input
             17           RXCb                    Input
             18           RXDb                    Input
             19           DCDb                    Input

                                      - 31 -
MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS

             20           DTRb                    Output
             25           DSRb                    Input
             26           GND                     --
                   Table 3-6. Definition of the RS-449 interface


3.2.3 V.35 Interface

             Pin          Signal name             Signal direction
             1            TXDa                    Output
             2            TXCEa                   Output
             3            TXCa                    Input
             4            RXCa                    Input
             5            RXDa                    Input
             6            DCD                     Input
             7            DTR                     Output
             8            RTSa                    Output
             11           CTS                     Input
             12           DSR                     Input
             14           TXDb                    Output
             15           TXCEb                   Output
             16           TXCb                    Input
             17           RXCb                    Input
             18           RXDb                    Input
             26           GND                     --
                    Table 3-7. Definition of the V.35 interface


3.2.4 X.21 Interface

             Pin          Signal name             Signal direction
             1            TXDa                    Output
             4            RXCa                    Input
             5            RXDa                    Input
             6            DCDa                    Input
             7            DTR                     Output
             8            RTS                     Output
             11           CTS                     Input
             12           DSR                     Input
             14           TXDb                    Output
             17           RXCb                    Input
             18           RXDb                    Input
             26           GND                     --

                                      - 32 -
MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS

                         Table 3-8. Definition of the X.21 interface


3.2.5 RS-530 Interface

                  Pin          Signal name             Signal direction
                  1            TXDa                    Output
                  2            TXCEa                   Output
                  3            TXCa                    Input
                  4            RXCa                    Input
                  5            RXDa                    Input
                  6            DCDa                    Input
                  7            DTRa                    Output
                  8            RTSa                    Output
                  9            RTSb                    Output
                  10           CTSb                    Input
                  11           CTSa                    Input
                  12           DSRa                    Input
                  14           TXDb                    Output
                  15           TXCEb                   Output
                  16           TXCb                    Input
                  17           RXCb                    Input--
                  18           RXDb                    Input--
                  19           DCDb                    Input--
                  20           DTRb                    Output
                  25           DSRb                    Input
                  26           GND                     --
                        Table 3-9. Definition of the RS-530 interface


3.2.6 V26 Conversion Cable

The product package contains V26-DB25 converter cables. Refer to related contents of
Annex-3 “CALBES” for their definitions.


3.3 Serial M&C Port

The serial M&C port is located at the left side of the front panel, which is in the form of
a RJ45 port. The pin assignment is defined as follows:

                  Pin          Signal name             Signal direction
                  1            RTS
                  2            DTR

                                           - 33 -
MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS

                3            TXD                     Output
                4            GND
                5            GND
                6            RXD                     Input
                7            DSR
                8            CTS
             Table 3-10. Definition of the interface of the serial M&C port


                    The serial M&C port does not provide flow control signal. If
                    connected equipment needs flow control signals, short-circuit RTS
                    and CTS, DTR and DSR signal lines of the equipment port.


The product package provides serial M&C cables compatible with the cable of the
Console port of Cisco router. Refer to the related contents contained in Annex-3
“CABLES” for its definition.




                                         - 34 -
MUX-2200E - CHAPTER-4 MANAGEMENT




CHAPTER-4 MANAGEMENT
The MUX-2200E may be configured through the front panel, the M&C port and
Ethernet port. This Chapter will introduce them respectively. See Chapter-5
“CONFIGURATION” for the detailed configuration methods and procedures.


4.1 Through Front Panel

4.1.1 Menu Hierarchy

The front panel of the MUX-2200E provides all function settings of local units. To
manage such functions and facilitate users’ understanding and memorization, the
control menu system of the MUX-2200E may be classified into the followings:
   Category - Root menu, including main function category
   Function - Secondary menu, including all function of a category
   Parameter - current value and option of a certain function
                   For complete menu list, see Annex-2 “CONTROL MENU”.


4.1.2 Buttons

  Button       Button Function
               Switch menu option under menu mode; change parameter
               modification position under parameter edition mode.
               Modify parameters or select parameter from options under the
               parameter edition mode.
  ENTER        Confirm the current menu selected to enter the submenu or display
               the current value of the parameter under the menu mode.
               Enter the parameter edition mode under the parameter display
               mode.
               Confirm the parameter value modification under the parameter
               edition mode.
  CLEAR        Return to the upper menu by pressing it under menu selection;
               Cancel the modification of the current parameters and restore the
               original setting under edition means.
                 Table 4-1. Definitions of buttons on the front panel




                                        - 35 -
MUX-2200E - CHAPTER-4 MANAGEMENT


4.1.3 Menu Operations


4.1.3.1 Standby Screen

The standby screen is as follows:




Press the ENTER key to enter the Category screen under the Standby screen.


4.1.3.2 Category Screen

The first line of the Category screen displays SELECT, prompting that the current
position is the root menu; the second line indicates all category items. “▲” will stop at
the current classified menu item position.




Press the     key or      key to move the cursor (“▲”signal) on the second line of the
screen to select specified category. Press the ENTER key to enter the specified function
group (secondary menu). Press the CLEAR key to return to the standby screen.


4.1.3.3 Function Screen

The first line of the Function screen displays the current category name, prompting the
current position is the secondary menu; the second line indicates all function items
contained in the category. “▲” will stop at the current function position.




Press the    key or     key to move the cursor (“▲”signal) on the second line of the
screen to select the specified function. Press the ENTER key to enter the Parameter
Display screen to view the current configurations. Press the CLEAR key to return to
the Category screen.


                    In some Function screen, the first line indicates that the bracket
                    behind the category name contains the specified port number.




                                         - 36 -
MUX-2200E - CHAPTER-4 MANAGEMENT


4.1.3.4 Parameter Display Screen

The first line of the Parameter Display screen displays the full name of the parameter
and the second displays the current parameter value.




Press the ENTER key to enter the Parameter Modification screen. Press the CLEAR to
return to the Function screen.
                    For some Parameter Display screen, the first line indicates that the
                    bracket behind the parameter name contains the current port
                    number specified.


4.1.3.5 Parameter Modification Screen

The first line of the Parameter Modification screen displays the full description of the
parameter and the second line displays the current value.




Press the     key or     key to move the cursor on the second line of the screen
(“▲”signal) and select editable position. Press the key or key select the current
parameter option or change parameter value at current editable position.
Press the ENTER key to confirm parameter modification and return to the Parameter
Display screen. Press the CLEAR to cancel parameter modification and return to the
Parameter Display screen directly.
                    For some Parameter Display screen, the first line indicates that the
                    bracket behind the parameter name contains the current port
                    number specified.


4.2 Through the M&C Port

The front panel of the MUX-2200E provides an RS-232 serial port of RJ45 type as the
M&C port, through which the computer can be used to monitor unit status and update
parameter configurations of the MUX-2200E.
To connect to the MUX-2200E through the serial M&C port, the following shall be
prepared:
   Terminal or computer with a serial port
   Serial M&C cable supplied with the equipment

                                         - 37 -
MUX-2200E - CHAPTER-4 MANAGEMENT


4.2.1 Connection Procedures

Follow the following procedures to use the M&C port to monitor the equipment:
     Plug the RJ45 cable connector of the M&C cable into the M&C port of the front
     panel of the MUX-2200E.
     Connect the 9-pin cable head at the other end of the M&C cable to the serial port of
     the computer.

                     To prevent computer serial interface or equipment M&C port from
                     being damaged, it is recommended to plug/unplug the M&C cable
                     in case of equipment outage.

     Run a terminal simulation software (ie. Hyperterminal) on the computer and set the
     following port parameters:
          Select correct serial port;
          Set data rate to 115,200bps;
          Set data format to 8 data-bits and 1 stop-bit, without Parity and flow control;
          Set the simulation mode as AUTO.
          Select “Terminal Keys” for the “Function, arrow and ctrl keys act as” instead
            of “Windows keys”.
     Connect the power cord of the MUX-2200E and turn on the power switch of the
     front panel, the front panel will display:


     The computer terminal software will display system boot information.

U-Boot 1.3.2 (May 6 2010 - 13:28:05)


MPC8272 Reset Status: External Soft, External Hard


MPC8272 Clock Configuration
- Bus-to-Core Mult 3.5x, VCO Div 2, 60x Bus Freq 30-85 , Core Freq 100-300
- dfbrg 1, corecnf 0x1e, busdf 3, cpmdf 1, plldf 0, pllmf 3, pcidf 7
- vco_out     400000000, scc_clk 100000000, brg_clk         25000000
- cpu_clk     350000000, cpm_clk 200000000, bus_clk        100000000
- pci_clk      25000000


CPU:    MPC8272 (HiP7 Rev 14, Mask 1.0 1K50M) at 350 MHz
Board: Motorola MPC8272ADS
DRAM: 64 MB
FLASH 1: 8 MB


……

                                          - 38 -
MUX-2200E - CHAPTER-4 MANAGEMENT

……


Loading system parameter......


WANCOM Communication & Networks Technology Ltd.
MUX2200E version 1.0.0165
Firmware version 0.1


SCCrun_Flag [0] =1 hdlc0: Carrier detected SCCrun_Flag [2] =1 hdlc1: Carrier
detected SCCrun_Flag [3] =1 hdlc2: Carrier detected voice bandwidth = 292000
Program download successful!
chip1 download successful! times=1 error=0


LOCAL>



When the boot procedure is completed, the front panel will display:




4.3 Through Ethernet port

Ethernet port J9 and J11 on the rear panel of the MUX-2200E may be used for
equipment configuration and management.
The computer may manage the MUX-2200E through the Ethernet port. The following
shall be prepared:
     Terminal or computer with network interface card
     Standard straight-connection cable


4.3.1 Connection Procedures

To use the Ethernet port to monitor the equipment, follow the following procedures:
     Connect the power cord of the MUX-2200E and turn on the power switch on the
     front panel, and wait for completion of the system boot procedure until the front
     panel displays:


     Use the LAN cable to connect the computer Ethernet port to Port 9 or Port 11 on the
     rear panel of the MUX-2200E.
     Set the equipment network address through the front panel menu- UNIT►IPADDR,

                                         - 39 -
MUX-2200E - CHAPTER-4 MANAGEMENT

  such as 192.168.1.1_24.
  The attribute of the computer network interface card are configured as follows:
       IP address: 192.168.1.x, x ranges from 2 to 254.
       Subnet Mask: 255.255.255.0
       Default gateway: Null
  Execute Start►Run on the computer and input cmd command to enter the
  MS-DOS command line mode. Enter the command:
        telnet [Unit IP address]
  After connecting successfully, the screen will pop up:
       LOCAL>




                                       - 40 -
MUX-2200E - CHAPTER-5 CONFIGURATION




CHAPTER-5 CONFIGURATION
Users may have full configurations and management for the MUX-2200E via the
keypad and LCD on the front panel.


5.1 Unit Management

This section covers some general settings for the equipment, including settings of the
M&C address, IP address and time and date as well as serial number and software
version inquiry. The operations of the front panel concentrate on the UNIT function
menu.


5.1.1 Set the M&C Address

Set the M&C Address for the MUX-2200E via menu UNIT►ADDR. The M&C
Address is selected from 0 to 255 (set 1 as default) via and . The screen display is
as follows:




5.1.2 Set the IP Address

Set the IP address and mask for the MUX-2200E via menu UNIT►IPADDR (set
192.168.1.1 as default IP address and 255.255.255.0 as default subnet mask).
The subnet mask is set via a decimal digit from 0 to 32. The masks used are as follows:

                           Code      Subnet Mask
                           8         255.0.0.0
                           16        255.255.0.0
                           24        255.255.255.0

Adjust the cursor position using      keys and modify values using        keys.
The screen display is as follows:




                                        - 41 -
MUX-2200E - CHAPTER-5 CONFIGURATION


5.1.3 Set the Date

Set the date and time for the MUX-2200E via menu UNIT►DATE. The screen display
is as follows:




5.1.4 Show the Serial Number

The serial number of the MUX-2200E may be inquired about via menu UNIT►SN.
The screen display is as follows:




5.1.5 Enable/Disable the LAN Group 2

Enable/disable the LAN Group 2 via menu UNIT►LAN2. Use           keys to select ON
or OFF (set OFF as default). The screen display is as follows:




                   Set LAN2 as ON to enable it, the serial Port CHN2 will be off
                   automatically.


5.1.6 Set the Screen Backlight

Turn on or off the LCD backlight of the front panel of the MUX-2200E via menu
UNIT►BACKLIGHT. Use the                    keys to select ON (backlight ON) or OFF
(backlight off). The screen display is as follows:



                   When the BACKLIGHT is set as ON, any button operation will
                   trigger the backlight of the LCD; No button operation lasts for
                   more than 20 seconds, the backlight of the screen will turn off
                   automatically until next button operation.




                                       - 42 -
MUX-2200E - CHAPTER-5 CONFIGURATION


5.2 Trunk Management

This section covers the configuration for CHN5 or CHN6 trunk ports. The Operations
on the front panel concentrate on the TRUNK function menu.


5.2.1 Select the Online Trunk Port

Two hardware ports on the rear panel of the MUX-2200E are available as trunk ports.
Select one as the online port and the other will become the backup port automatically.
Use the  keys to select one of two ports (CHN5 and CHN6) as the online port via
menu TRUNK►PORT. The screen display is as follows:




The selected trunk port number will appear in the bracket of the first line on the
TRUNK function screen.




5.2.2 Set the TX Data Rate

Theoretically the MUX-2200E supports a TX data rate of up to 20Mbps. The actual TX
data rate will be an integral multiple of the step rate of the multiplexer.
Use the      keys to adjust the cursor positions via menu TRUNK►TXDR and press
the     keys to modify the value of the cursor position. The TX data rate is k times,
which ranges from 0 to 2048, of the step rate. The screen display is as follows:




                    Related settings: Refer to 5.6.2 “Set the Step Rate”.


5.2.3 Set the TX Clock Mode

The TX clock of the trunk port of the MUX-2200E may be set to the following three
kinds of clock modes. The MUX-2200E is at the DTE side in the figure below.
   TT mode - TX data will be synchronized with the TT clock at the DTE side. DCE
   equipment will acquire a clock from the DTE side.



                                        - 43 -
MUX-2200E - CHAPTER-5 CONFIGURATION

                             DTE          SD           DCE

                                          TT

                                          ST

                                          RD

                                          RT




   ST mode - TX data will be synchronized with the ST clock at the DCE side. DTE
   equipment will acquire a clock from the DCE side.
                             DTE          SD           DCE

                                          TT

                                          ST

                                          RD

                                          RT




   RT mode - TX data will be synchronized with the RX clock.
                             DTE          SD           DCE

                                          TT

                                          ST

                                          RD

                                          RT




Adjust the TX clock mode via menu TRUNK►TXCM. Press the                keys to select TT,
ST or RT. The screen display is as follows:




When the clock at the trunk port is set as TT clock, the MUX-2200E may select either
built-in high-precision clock or the serial port clock as the clock source.

                    Related settings: Refer to 5.6.1“Set the Clock Source”.


5.2.4 Set the TX Clock Polarity

Press the key or the      key to adjust the TX clock polarity at the trunk port via menu
TRUNK►RXCP.
   Select NORMAL - TX data will be updated at the clock falling edge, and the
   equipment at the remote side shall sample data at the clock rising edge
   Select INVERT - TX data will be updated at the clock rising edge, and the
   equipment at the remote side shall sample data at the clock falling edge).
The screen display is as follows:



                                         - 44 -
MUX-2200E - CHAPTER-5 CONFIGURATION




5.2.5 Set the RX Data Rate

Via menu TRUNK►RXDR, press the               key or the      key to adjust the cursor
position and press the key or the key to modify the value at the cursor position.
The RX data rate is k times, which ranges from 0 to 2,048, of the step rate. The screen
display is as follows:




                    Related settings: See 5.6.2 “Set the Step Rate”.


5.2.6 Set the RX Clock Polarity

Via menu TRUNK►RXCP, Press the              key or the     key to adjust the RX clock
polarity of the trunk port.
   Select NORMAL - (normal polarity) Sample and receive data at the clock rising
   edge
   Select INVERT - (opposite polarity) Sample and receive data at the clock falling
   edge
The screen display is as follows:




5.2.7 Set the Trunk Loopback

Active the trunk loopback function via menu TRUNK►LPBK. It is often used for
system testing. Press the key or the    key to select NORMAL (loopback OFF) or
LOOPBACK (loopback ON).




                                        - 45 -
MUX-2200E - CHAPTER-5 CONFIGURATION

The screen display is as follows:




                    Related setting: Refer to 5.3.8 “Set the Port Loopback”


5.3 Serial Port Management

This section covers the configuration for serial ports (CHN1-CHN4). Operations on the
front panel concentrate on the SERIAL function menu.


5.3.1 Select the Current Serial Port

Four hardware ports CHN1-CHN4 of the MUX-2200E work as the serial ports. Users
may configure any one or several serial ports according to link requirements;
The function “Select the current serial port” can be realized via menu
SERIAL►PORT. Press the           key or the     key from CHN1 to CHN4 to select any
one port as the current specified port (here the specified port selected is CHN1). The
screen display is as follows:




Selected serial port number will appear in the bracket of the first line displayed on the
SERIAL Function screen. The screen display is as follows:




5.3.2 Set the TX Data Rate

Theoretically the serial port of the MUX-2200E supports up to a TX data rate of
10Mbps. The TX data rate actually set shall be integral multiple of the step rate of the
multiplexer.
Use the    key or the     key to adjust the cursor position and use the key or the
key to modify the value where the cursor is located via menu SERIAL►TXDR. The
TX data rate is k times, which ranges from 0 to 2048, of the step rate.
The screen display is as follows:




                                         - 46 -
MUX-2200E - CHAPTER-5 CONFIGURATION


                   Related setting: See 5.6.2 “Set the Step Rate”


5.3.3 Set the TX Clock Mode

The TX clock of the serial port of the MUX-2200E may be set to the following three
kinds of clock modes. The MUX-2200E constitutes the equipment at the DCE side in
the diagram below.
   TT mode - TX data will be synchronized with the clock at the DTE side, and the
   DCE equipment will acquire clock from the DTE side.




   ST mode - TX data will be synchronized with the clock at the DCE side. The DTE
   equipment will acquire a clock from the DCE side.




   RT mode - The TX clock will be synchronized with the RX clock.




Adjust the TX clock mode via menu SERIAL►TXCM. Press the            key or the   key
to select TT, ST or RT. The screen display is as follows:




When the serial port clock is set as the ST mode, the MUX-2200E may select the
built-in high precision clock or other serial port clock as the clock source.

                   Related setting: See 5.6.1 “Set the Clock Source.”



                                       - 47 -
MUX-2200E - CHAPTER-5 CONFIGURATION


5.3.4 Set the TX Clock Polarity

Adjust the TX clock polarity of the trunk port via menu SERIAL►TXCP. Press the
key or the key to select NORMAL or INVERT. The screen display is as follows:




5.3.5 Set the RX Data Rate

Use the        key or the        key to adjust the position of the cursor via menu
SERIAL►RXDR and use the              key or the     key to modify the value where the
cursor is located. The RX data rate is k times, which ranges from 0 to 2048, of the step
rate. The screen display is as follows:




                    Related setting: See 5.6.2 “Set Step Rate”


5.3.6 Set the RX Clock Polarity

Adjust the RX clock polarity of the trunk port via menu SERIAL►RXCP. Press the
key or the key to select NORMAL or INVERT. The screen display is as follows:




5.3.7 Set the Async Mode

Set the async mode of the serial port via menu SERIAL►ASYNC. Users may use the
   key or the key to select ON (async mode) or OFF (sync mode). The screen display
is as follows:




5.3.8 Set the Port Loopback

The serial port loopback may be enabled via menu SERIAL►LPBK. It is often used
for system testing. Press the key or the key to select OFF (loopback off) or ON
(loopback on).

                                         - 48 -
MUX-2200E - CHAPTER-5 CONFIGURATION




The screen display is as follows:




                    Related setting: See 5.2.7 “Set the Trunk Loopback”


5.4 Voice Port Management

This section covers the configuration for voice ports (J1-J4). Operations on the front
panel concentrate on the VOICE functional classification menu.


5.4.1 Select the Current Voice Port

The MUX-2200E provides four hardware ports (J1~J4) as voice ports. Via menu
VOICE►PORT, press the key or the key to select one as the currently specified
configuration port (here select J1 as the specified port).
The screen display is as follows:




The current voice port number selected will appear in the bracket of the first line
displayed on the voice function screen.
The screen display is as follows:




5.4.2 Enable/Disable the Voice Port

Via menu VOICE►ENABLE, press the                 key or the   key to enable or disable
current voice port. The screen display is as follows:



                                         - 49 -
MUX-2200E - CHAPTER-5 CONFIGURATION




5.4.3 Set the Fax Lines

Via menu VOICE►FAXLINE, press the key or the key to select a number from
1 to 4 to set the maximum fax lines (here the fax line number is set as 1). The screen
display is as follows:




5.4.4 Set the Voice Coder

Via menu VOICE►CODER, press the key or the key to select G.711 or G.723.1
to set the voice coder for the current voice port (here it is set as G.711). The screen
display is as follows:




5.4.5 Set the Voice Volume

Via menu VOICE►VOL, press the             key or the   key to modify from -32dB to
+31dB to adjust the volume for the current voice port (here the default setting of the
volume is 0dB). The screen display is as follows:




5.4.6 Set the DTMF Level

Via menu VOICE►DTMF, press the key or the key to modify it from -32dB to
+3dB and adjust the DTMF Level for the current voice port (here the default setting of
the volume is -4dB).The screen display is as follows:




5.5 E1 Port Management

This section covers the configuration for the E1 ports (J5-J8). Operations on the front

                                        - 50 -
MUX-2200E - CHAPTER-5 CONFIGURATION

panel concentrate on the E1 function menu.


5.5.1 Select the Current E1 Port

The MUX-2200E with standard configurations provides 4 hardware ports (J5-J8) as E1
ports. Via menu E1►PORT, press the           key or the     key to select any port as the
currently specified configuration port from J5 to J8 (here the current port selected is J5).
The screen display is as follows:




The currently selected E1 port number will appear in the bracket of the first line
displayed on the E1 function screen after completing such setting. The screen display is
as follows:




5.5.2 Enable/Disable the E1 Port

Via menu E1►TYPE, press the               key or the        key to select OFF/E1 to
Enable/Disable the current E1 port . The screen display is as follows:




5.5.3 Enable/Disable the CRC Function

Via menu E1►CRC, press the            key or the      key to select ON/OFF to
Enable/Disable the CRC function for the current E1 port (here the default setting is
OFF) .
The screen display is as follows:




5.5.4 Set the Time Slots

Via menu E1►SLOT, set the time slot of the current E1 port. Press the             key or the
    key to adjust the cursor position to select the assigned time slot, and press the key
or the key to select 1 or 0.


                                           - 51 -
MUX-2200E - CHAPTER-5 CONFIGURATION

                    The time slots parameter is a 32-bit binary number, which
                    represents Time Slot 0, 1, …, 31 of E1 from left to right. Each bit
                    distinguishes the status of the time slot: 1 (indicates that the time
                    slot is occupied) or 0 (indicates that the time slot is not occupied).
                    As the left first Time Slot is set to 0, it indicates the current port
                    support non-framing data stream.
The screen display is as follows:




5.5.5 Set the Sync Mode

Via menu E1►SYNC, press the         key or the     key to select ON or OFF and set the
sync mode of the current E1 port (here the default setting is ON). The screen display is
as follows:




5.5.6 Set the Impedance

Via menu E1►IMPED, press the key or the key to select 75 ohm or 120 ohm and
set the impedance of the current E1 port (here the default setting is 120 ohm). The
screen display is as follows:




5.5.7 Inquire the TX Data Rate

Inquire about the TX data rate of the specified E1 port via menu E1►TXDR, the
parameter will be modified automatically according to the SLOT setting.
The screen display is as follows:




                    Related setting: See 5.5.4 “Set the Time Slots”




                                         - 52 -
MUX-2200E - CHAPTER-5 CONFIGURATION


5.5.8 Inquire the RX Data Rate

Inquire about the RX data rate of the specified E1 port via menu E1►RXDR, the
parameter will be modified automatically according to the SLOT setting.
The screen display is as follows:




                    Related setting: See 5.5.4 “Set the Time Slots”


5.5.9 Inquire the Local Status

Via menu E1►STATUS, inquire about the local status for the current E1 port. Press the
  key or the key to scroll screen and inquire more contents.
The default setting displays “Not E1 Interface” when the E1 port is disabled. The screen
display is as follows:




5.5.10 Inquire the Remote Status

Via menu E1►RSTATUS, inquire about the status of the corresponding E1 port of the
remote equipment. Press the key or the    key to scroll screen and inquire more
contents.
The screen display is as follows:




5.5.11 Set the Port Loopback

Via menu E1►LPBK, press the key or the            key to select LLP, RLP or OFF and set
the loopback function for the current E1 port.
   LLP - Loopback toward local side.




                                         - 53 -
MUX-2200E - CHAPTER-5 CONFIGURATION




   RLP - Loopback toward remote side.




The screen display is as follows: (here the default setting is set as OFF and the port
loopback is OFF)




5.6 Utility

5.6.1 Set the Step Rate

Set the step rate for MUX-2200E via menu UTILITY►DRSTEP. Press the             key or
the    key to adjust the cursor position and press the key or the key to modify the
value where the cursor is located. The step rate is n times 100bps, in which n ranges
from 1 to 160.
The screen is displayed in the table below.




5.6.2 Set the Clock Source

Via menu UTILITY►REFS, press the              key or the    key to select and set the
reference clock source of the TX clock of the system.
See the table below for optional clock sources.

       Code                Clock source
       TCXO                Built-in temperature compensated crystal Oscillator
       CHN1-CHN4           TT clock of 4 serial ports, CHN1-CHN4
       ST                  ST clock of trunk port

                                         - 54 -
MUX-2200E - CHAPTER-5 CONFIGURATION

       RT                  RT clock of trunk port
       E1P1-E1P8           Restoring clock of E1P1-E1P8
                             Table 5-1 System clock source

The screen display is as follows:




5.6.3 Reboot

Via menu UTILITY►REBOOT, press the           key or the   key to select YES and
press the ENTER key to reset the MUX-2200E immediately. The screen is displayed in
the table below.



                    The REBOOT function will result in interruption of the current
                    data links.


5.6.4 Restore to Default

Via menu UTILITY►DEFAULT, press the                  key or the key to select YES and
press the ENTER key to clear all system configurations, which shall not affect the
settings of the IP address. All user settings of the MUX-2200E will be erased and set to
the default setting.
The screen is displayed in the table below.




                    The DEFAULT operation will not affect the IP address setting.


                    The DEFAULT operation will result in interruption of the current
                    links.


5.7 Status

This section covers status and alarm information inquiry. Operations of the front panel
concentrate on the STATUS function classification menu.




                                         - 55 -
MUX-2200E - CHAPTER-5 CONFIGURATION


5.7.1 Display the Current Status

Inquire about the current status via the STATUS►STAT menu.
The screen is displayed in the table below.




5.7.2 Display the Active Alarms

Inquire about all active alarm information via menu UTILITY►ALARM. Use the
key and key to scroll screen and display alarm lists.




                                         - 56 -
MUX-2200E - CHAPTER-6 MAINTENANCE




CHAPTER-6 MAINTENANCE
This Chapter mainly describes the field maintenance of the MUX-2200E, which
consists of chassis clearance, function board replacement and software version update.
It also gives additional descriptions of disassembly and assembly of main components
according to field maintenance demand.


6.1 Disassemble the Major Components

                    Before conduct any hardware replacement and software upgrade,
                    user must be officially authorized by the manufacturer and follow
                    the steps prescribed in this Chapter. Any hardware operation and
                    software upgrade without official written authorization will void
                    the product warranty immediately.


6.1.1 Precautions for Disassembly

                    Read and follow all precautions mentioned on the section “Safety
                    Instructions” in the manual. If additional descriptions provided
                    with the equipment are not consistent with these descriptions,
                    contact the technical service personnel of the supplier to
                    acknowledge.
   To ensure heat radiation and ventilation, the chassis cover must be installed before
   the MUX-2200E is powered.
   The power supply switch cannot cut off the AC power supply completely. To cut it
   off completely, it is recommended to unplug the power cord connected to the
   MUX-2200E from the AC sockets.
   The following operations must be conducted on the ESD platform when it is
   necessary to open the chassis for component replacement or inspection. If such
   platform is not available, reduce the ESD hazards by the following means:
   Wear an anti-static bracelet and connect it to the metal part of the MUX-2200E.
   Touch the metal case of the MUX-2200E chassis before touching any parts of the
   MUX-2200E.
   Keep part of the body in touch with the metal chassis of the MUX-2200E to
   discharge electrostatic while handling components.
   Avoid unnecessary movements.
   Hold the components (especially the boards) by the edges when handling the
   MUX-2200E parts.
   Place the MUX-2200E components on a grounded, static-free operating platform.
   Use a conductive foam pad if available rather than use the component wrapper.

                                        - 57 -
MUX-2200E - CHAPTER-6 MAINTENANCE

   Do not let components slide on the operating platform.


6.1.2 Tools for Disassembly

   Cross-head screwdriver;
   Anti-static bracelet and conductive foam pad (recommended);
   Paper and pens used to record the modification of the MUX-2200E system
   configuration status as well as specific information of all installed parts including
   the part number and the serial number;


6.1.3 Disassemble the Top Cover of the Chassis

                    Ensure you have fully understood the contents contained in
                    Precautions for Disassembly in this Chapter before operation and
                    have read the safety warnings and precautions on the section
                    “Safety Instructions” in the manual.


6.1.3.1 Remove the Top Cover of the Chassis

   Turn off the MUX-2200E and all the devices connected to it,
   Unplug the AC power cord.
   If the MUX-2200E is rack-mounted, the grounding wires and all related connection
   cables shall be removed, the equipment may be taken off of the rack and be placed
   on the disassembling platform; if the MUX-2200E is non-rack-mounted, other
   equipment stacked on it shall be taken down and related connection cables shall
   also be removed from the front and rear panels.
   Remove the 12 screws on the top cover of the chassis (refer to “①” shown in the
   figure below) and lift the top cover up (refer to “②” shown in the figure below).




           Figure 6-1. Disassembling diagram of the top cover of the chassis

The installation procedure for the top cover of the chassis is opposite of the remove
procedure of the top cover of the chassis.

                                        - 58 -
MUX-2200E - CHAPTER-6 MAINTENANCE


6.1.4 Disassemble the Functional Modules

                   Ensure you have fully understood the contents contained in
                   Precautions for Disassembly in this Chapter and have read the
                   safety warnings and precautions on the section “Safety
                   Instructions” in the manual before operation.


6.1.4.1 Remove the Functional Modules

   Remove the top cover of the chassis (refer to the operation procedure of “Remove
   the top cover of the chassis”).
   Loosen the screws on the functional board (see “①” shown in the figure below,
   each sub-board is fastened with 2 screws).
   Press the system motherboard with one hand and hold the module edge with the
   other hand and lift it from the ramp top with even force and remove the board (see
   “②” shown in the figure below).




            Figure 6-2. Disassembling diagram for the functional modules


6.1.4.2 Install the Functional Modules

   Remove the top cover of the chassis. (Refer to the operation methods of “Remove
   the top cover of the chassis”)
   Align the interface on the functional module to the interface sockets on the
   motherboard and check whether the positions of four fastening screw holes on the
   board correspond to the supporting columns (see “①” shown in the figure below).
   Press the module down with even force from the interface positions at two sides of
   the module (see “②” shown in the figure below).
   Fasten the screws on the functional board.



                                       - 59 -
MUX-2200E - CHAPTER-6 MAINTENANCE




             Figure 6-3. Installation diagram for the functional modules


6.1.5 Disassemble the Motherboard

                   Ensure you have fully understood the contents contained in
                   Precautions for Disassembly in this Chapter before operation and
                   have read the safety warnings and precautions on the section
                   “Safety Instructions” in the manual.


6.1.5.1 Remove the Motherboard

  Remove the top cover of the chassis (refer to the operation procedure of “Remove
  the top cover of the chassis”).
  Remove the functional modules (refer to the operation procedure of “Remove the
  functional modules”).
  Unplug the connection wires of other modules on the motherboard, include the
  exhausted fan, the power supply module, the keypad display module and the M&C
  interface module.
  Loosen 4 screws on the motherboard (see “①” shown in the figure below).
  Slip out the motherboard from the interface clearance of the rear panel of the chassis
  after inclining the board to one side (see “②” shown in the figure below).




                                        - 60 -
MUX-2200E - CHAPTER-6 MAINTENANCE




              Figure 6-4. Disassembling diagram for the motherboard


6.1.5.2 Install the Motherboard

  Remove the top cover of the chassis. (Refer to the procedure for “Remove the top
  cover of the chassis”).
  Align the interface pins on the motherboard to the corresponding vacancy on the
  rear board (see “①” and “②” shown in the figure below), check whether the
  positions of the 4 fastening screw holes on the motherboard correspond to the
  supporting columns on the motherboard (see “③” shown in the figure below).
  Fasten 4 screws on the motherboard.
  Install the functional modules (Refer to the procedure for “Installing functional
  modules”)
  Connect the motherboard to the plugs of the connection wires of other modules in
  the chassis, includes the exhausted fan, the power supply module, the keypad
  display module and the M&C interface module).




               Figure 6-5. Installation diagram for the motherboard



                                      - 61 -
MUX-2200E - CHAPTER-6 MAINTENANCE


6.2 Clean the Chassis

                     Ensure you have fully understood the contents of this Chapter and
                     have read the safety warnings and precautions on the section
                     “Safety precautions” of the manual.

                     Power supply button cannot cut off the AC power supply
                     completely. To cut it off completely, the user must unplug all the
                     power cords connected to the MUX-2200E from the AC sockets.


Following the following steps to clear dust accumulated in the chassis over a long time.
It is recommended to perform such cleaning once a year according to the conditions of
the computer room.
   Remove the top cover of the chassis. (Refer to the procedure for “Remove the top
   cover of the chassis”).
   Clean the chassis with a dust catcher, especially the positions near to the left air inlet
   and the right exhaust fan.
   Clean the above positions with a brush if thick dust has accumulated. Repeat the
   above step.
   Check and ensure no foreign articles are left in the chassis, install the top cover of
   the chassis. (Refer to the procedure for “Install the top cover of the chassis”).
   Power on the equipment and check its status.


6.3 Replace the Functional Boards

                     Ensure you have fully understood the contents of this Chapter and
                     have read the safety warnings and precautions on the section
                     “Safety precautions” of the manual.

                     Power supply button cannot cut off the AC power supply
                     completely. To cut it off completely, the user must unplug all the
                     power cords connected to the MUX-2200E from the AC sockets.

                     Replacement of the functional board (motherboard) may result in
                     missing original parameter configuration. Record such
                     configuration in advance before replacement.


Replacement of any functional board must follow the following steps based on the
demand for system hardware configuration adjustment and for rapid field maintenance
of faulty boards.
   Record the current parameter configurations.
                                           - 62 -
MUX-2200E - CHAPTER-6 MAINTENANCE

   Remove the top cover of the chassis. (Refer to the procedure for “Remove the top
   cover of the chassis”).
   Use a dust catcher to dedust the inside of the chassis.
   Remove the original functional board (motherboard). (Refer to the procedure for
   “Remove the functional board (motherboard)”).
   Record the type and serial number information of the current boards as well as the
   type and serial number information of new boards.
   Install the new functional board (motherboard). (Refer to the procedure for “Install
   the functional board (motherboard”).
   Check and ensure no foreign articles are left in the chassis, install the top cover of
   the chassis. (Refer to the procedure for “Install the top cover of the chassis”).
   Power on the equipment and check its status.
   Check parameter configurations.
Fill out the following form after the replacement of functional boards is completed, and
inform the Customer Service Center of Wancom via fax or e-mail.
Customer name:                            Telephone:
Engineer name:                            E-mail:
Replacement Time:

Unit Part Number:                         Serial Number:
Motherboard                               Serial number:
Module:
CPU Module:                               Serial number:
Voice Module:                             Serial number:
E1 Module:                                Serial number:

New Board:                                Serial number:
                       Table 6-1. Field Maintenance Record Sheet


6.4 Upgrade the Firmware

The MUX-2200E supports field software upgrading to realize notable improvement of
equipment performance. Users may consult the manufacturer to acquire new product
software upgrading data package.
                    Theoretically, system software version upgrading will not result in
                    missing original parameter configurations. For the sake of safety, it
                    is recommended to record the original configurations before
                    upgrading.

   Use cables to connect the computer and J10 or J12 on the rear panel of the
   MUX-2200E to be upgraded; or connect the computer for upgrading and the
   MUX-2200E to the same network exchange or HUB via LAN cables.
                                         - 63 -
MUX-2200E - CHAPTER-6 MAINTENANCE

  Set the computer and the MUX-2200E to be upgraded at the same IP network
  segment.
  Find the folder contained the MUX-2200E upgrading file on the computer and
  double-click the icon to run the upgrading program.




                  Figure 6-6. Software upgrade program interface
  Click the SCAN button in the Upgrade Program window; the program will search
  all linkable MUX-2200E.




            Figure 6-7. The upgrade program screen – unit scan process
  Select the corresponding IP address of the MUX-2200E which needs to upgrade
  firmware in the “Machines List” list in the upper left corner of the window and view
  the current version information in the “Version Information:” in the upper right
  corner of the window and confirm the version that needs to be upgraded.
  Check the checkbox before “Reboot after Upgrade” in the middle of the window.
  Click the Upgrade button to start the uploading process of the firmware upgrade

                                       - 64 -
MUX-2200E - CHAPTER-6 MAINTENANCE

package.
                 The user may enter the IP address of the MUX-2200E to be
                 upgraded in the address column at the left of the Upgrade button in
                 the middle of the window, and click the Upgrade button to start the
                 uploading of the upgrade software package.




           Figure 6-8. The upgrade program screen - uploading process
The program prompts “info: upgrade finished”, the MUX-2200E will reboot
automatically.
Use the Hyperterminal or Telnet to connect equipment and check the new version
information displayed on the screen, or use the upgrade program to execute the
SCAN operation again and select the MUX-2200E after upgraded and view the new
version information in the Version Information box.
Check whether equipment configurations are complete and accurate.




                                     - 65 -
MUX-2200E - CHAPTER-6 MAINTENANCE

                This page is intentionally left blank.




                                - 66 -
MUX-2200E - ANNEX-1 CLI COMMAND




ANNEX-1 CLI COMMAND

A1.1 Basic Command Formats

The CLI command formats for the MUX-2200E are classified as three kinds.

Port (interface)-related configuration operations
    Input command: <Address/command_port_[value]
    Device feedback: >Address/command_port_value

Other configuration operations
    Input command: <Address/command_[value]
    Device feedback: >Address/command_value

Inquiry operations
    Input command: <Address/command_
    Device feedback: >


A1.1.1 Start Character

Computer to Device: ’<’ (ASCII code 60)
Device to Computer: ’>’ (ASCII code 62)


A1.1.2 Unit Address

Address range used for serial M&C is 0~255 and the default address is 1. It is set via
UNIT►ADDR on the front panel.


A1.1.3 Address Separator

‘/’ (ASCII code 47) is used as the separator between address and command in the CLI
command format.


A1.1.4 Command Code

Command code consists of a character string of variable lengths in the CLI command

                                        - 67 -
MUX-2200E - ANNEX-1 CLI COMMAND

format without the upper and lower case difference.


A1.1.5 Instruction Code Qualifiers

In CLI command format, both ’_’ (i.e. the underline, which ASCII code is 95) and ’ ’ (i.e.
the space character, which ASCII code is 32) may be qualifiers for mixed use.
E.g., enter the following two commands via the keypad, their roles are exactly the same.
          <addr/TXDR_n_[xxx]
          <addr/TXDR n [xxx]


A1.1.6 Port Number

In CLI command format, the port number ranges from 0 to 9. The correspondence
between the port number in the command format and the hardware port is shown in the
table below under normal conditions:

                 Port #        hardware port       Remarks
                 0             CH5/CH6             Serial trunk port
                 1-4           CH1-CH4             Serial port
                 5-8           J5-J8               E1 port
                 9             J1-J4               Voice port
                      Table 7-1. Port number correspondence table


A1.1.7 Optional Parameter Values

In CLI command format, parameter values correspond to those of specific ports or the
value of specific parameters. If input commands do not contain parameter values, the
equipment will return to the current configuration or status.


A1.2 CLI Command Set

A1.2.1 Port Commands


Enable/Disable the voice port
Command:     <addr/VEN_n_[xxx]
Answer:      >addr/VEN_n_xxx
n:           voice port number, n=1-4
xxx:         ON/OFF, xxx=ON/OFF

                                          - 68 -
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1
O&m manual(mux 2200 e)v1.1

Contenu connexe

Tendances

Compaq + hp service manual notebook - notebook series general
Compaq + hp service manual   notebook - notebook series generalCompaq + hp service manual   notebook - notebook series general
Compaq + hp service manual notebook - notebook series generalCCE COMPUTACION
 
ALPHASEAPILOT MFA Autopilot
ALPHASEAPILOT MFA Autopilot ALPHASEAPILOT MFA Autopilot
ALPHASEAPILOT MFA Autopilot Le Minh
 
01 28008-0004-20050204 forti-gate-200_administration guide
01 28008-0004-20050204 forti-gate-200_administration guide01 28008-0004-20050204 forti-gate-200_administration guide
01 28008-0004-20050204 forti-gate-200_administration guidesarpro
 
Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)
Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)
Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)ufjjdfjkskemd
 
Win plc engine-en
Win plc engine-enWin plc engine-en
Win plc engine-endreamtech2
 

Tendances (9)

Mach3 Turn 1.84
Mach3 Turn 1.84Mach3 Turn 1.84
Mach3 Turn 1.84
 
Compaq + hp service manual notebook - notebook series general
Compaq + hp service manual   notebook - notebook series generalCompaq + hp service manual   notebook - notebook series general
Compaq + hp service manual notebook - notebook series general
 
ALPHASEAPILOT MFA Autopilot
ALPHASEAPILOT MFA Autopilot ALPHASEAPILOT MFA Autopilot
ALPHASEAPILOT MFA Autopilot
 
Open VAS Manual
Open VAS ManualOpen VAS Manual
Open VAS Manual
 
01 28008-0004-20050204 forti-gate-200_administration guide
01 28008-0004-20050204 forti-gate-200_administration guide01 28008-0004-20050204 forti-gate-200_administration guide
01 28008-0004-20050204 forti-gate-200_administration guide
 
Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)
Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)
Komatsu wa200 pz 6 wheel loader service repair manual (sn 70001 and up)
 
Bucher lift control guide
Bucher lift control guideBucher lift control guide
Bucher lift control guide
 
Win plc engine-en
Win plc engine-enWin plc engine-en
Win plc engine-en
 
Omron CS1D
Omron CS1DOmron CS1D
Omron CS1D
 

En vedette

3 dimensional shapes powerpoint
3 dimensional shapes powerpoint3 dimensional shapes powerpoint
3 dimensional shapes powerpointathorburn
 
Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...
Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...
Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...OndaSolution
 
TRILATIONS: E/I government
TRILATIONS: E/I governmentTRILATIONS: E/I government
TRILATIONS: E/I governmentTRILATIONS
 
Trilations company presentation
Trilations company presentationTrilations company presentation
Trilations company presentationTRILATIONS
 

En vedette (8)

Uruguay!!!!!
Uruguay!!!!!Uruguay!!!!!
Uruguay!!!!!
 
Uruguay!!!!
Uruguay!!!!Uruguay!!!!
Uruguay!!!!
 
3 dimensional shapes powerpoint
3 dimensional shapes powerpoint3 dimensional shapes powerpoint
3 dimensional shapes powerpoint
 
Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...
Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...
Regolamento controlli interni ex dl 174 2012 convertito in l 213-2012 version...
 
TRILATIONS: E/I government
TRILATIONS: E/I governmentTRILATIONS: E/I government
TRILATIONS: E/I government
 
Uruguay!!!!
Uruguay!!!!Uruguay!!!!
Uruguay!!!!
 
Trilations company presentation
Trilations company presentationTrilations company presentation
Trilations company presentation
 
Uruguay
UruguayUruguay
Uruguay
 

Similaire à O&m manual(mux 2200 e)v1.1

Motorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guideMotorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guideAdvantec Distribution
 
Motorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guideMotorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guideAdvantec Distribution
 
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAdvantec Distribution
 
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAdvantec Distribution
 
B7.2 a1353-ra platform commissioning solaris 2.6
B7.2 a1353-ra platform commissioning solaris 2.6B7.2 a1353-ra platform commissioning solaris 2.6
B7.2 a1353-ra platform commissioning solaris 2.6chungminh1108
 
software-eng.pdf
software-eng.pdfsoftware-eng.pdf
software-eng.pdffellahi1
 
350209_NGU-2000 BB (799020).pdf
350209_NGU-2000 BB (799020).pdf350209_NGU-2000 BB (799020).pdf
350209_NGU-2000 BB (799020).pdfGerson37561
 
Nx 8-eur ins e ge 020706
Nx 8-eur ins e ge 020706Nx 8-eur ins e ge 020706
Nx 8-eur ins e ge 020706gzebel
 
T Series Core Router Architecture Review (Whitepaper)
T Series Core Router Architecture Review (Whitepaper)T Series Core Router Architecture Review (Whitepaper)
T Series Core Router Architecture Review (Whitepaper)Juniper Networks
 
PT - Siemens WinCC Flexible Security Hardening Guide
PT - Siemens WinCC Flexible Security Hardening GuidePT - Siemens WinCC Flexible Security Hardening Guide
PT - Siemens WinCC Flexible Security Hardening Guideqqlan
 
60950106 basis-latest-till-interview-questions
60950106 basis-latest-till-interview-questions60950106 basis-latest-till-interview-questions
60950106 basis-latest-till-interview-questionsRavic Kumar
 
Teamviewer manual
Teamviewer manualTeamviewer manual
Teamviewer manualjeetjsr11
 
Teamviewer manual
Teamviewer manualTeamviewer manual
Teamviewer manualEroel Irzha
 
Teamviewer manual by PW
Teamviewer manual by PWTeamviewer manual by PW
Teamviewer manual by PWtesttodel
 
E2027 a8v e-se
E2027 a8v e-seE2027 a8v e-se
E2027 a8v e-seyyc73
 
E1911 a8n e
E1911 a8n eE1911 a8n e
E1911 a8n epratmen
 
Motorola air defense mobile 6.1 user guide
Motorola air defense mobile 6.1 user guideMotorola air defense mobile 6.1 user guide
Motorola air defense mobile 6.1 user guideAdvantec Distribution
 

Similaire à O&m manual(mux 2200 e)v1.1 (20)

Motorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guideMotorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guide
 
Motorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guideMotorola ws2000 wireless switch system reference guide
Motorola ws2000 wireless switch system reference guide
 
2226 v3 rev_a
2226 v3 rev_a2226 v3 rev_a
2226 v3 rev_a
 
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revd
 
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )
 
Ap650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revdAp650 installation guide_72_e-131207-01_revd
Ap650 installation guide_72_e-131207-01_revd
 
B7.2 a1353-ra platform commissioning solaris 2.6
B7.2 a1353-ra platform commissioning solaris 2.6B7.2 a1353-ra platform commissioning solaris 2.6
B7.2 a1353-ra platform commissioning solaris 2.6
 
software-eng.pdf
software-eng.pdfsoftware-eng.pdf
software-eng.pdf
 
350209_NGU-2000 BB (799020).pdf
350209_NGU-2000 BB (799020).pdf350209_NGU-2000 BB (799020).pdf
350209_NGU-2000 BB (799020).pdf
 
Nx 8-eur ins e ge 020706
Nx 8-eur ins e ge 020706Nx 8-eur ins e ge 020706
Nx 8-eur ins e ge 020706
 
T Series Core Router Architecture Review (Whitepaper)
T Series Core Router Architecture Review (Whitepaper)T Series Core Router Architecture Review (Whitepaper)
T Series Core Router Architecture Review (Whitepaper)
 
PT - Siemens WinCC Flexible Security Hardening Guide
PT - Siemens WinCC Flexible Security Hardening GuidePT - Siemens WinCC Flexible Security Hardening Guide
PT - Siemens WinCC Flexible Security Hardening Guide
 
60950106 basis-latest-till-interview-questions
60950106 basis-latest-till-interview-questions60950106 basis-latest-till-interview-questions
60950106 basis-latest-till-interview-questions
 
Teamviewer manual
Teamviewer manualTeamviewer manual
Teamviewer manual
 
Teamviewer manual
Teamviewer manualTeamviewer manual
Teamviewer manual
 
Teamviewer manual by PW
Teamviewer manual by PWTeamviewer manual by PW
Teamviewer manual by PW
 
E2027 a8v e-se
E2027 a8v e-seE2027 a8v e-se
E2027 a8v e-se
 
E1911 a8n e
E1911 a8n eE1911 a8n e
E1911 a8n e
 
Motorola air defense mobile 6.1 user guide
Motorola air defense mobile 6.1 user guideMotorola air defense mobile 6.1 user guide
Motorola air defense mobile 6.1 user guide
 

O&m manual(mux 2200 e)v1.1

  • 1. MUX-2200E INTEGRATED SERVICE MULTIPLEXER OPERATION AND MAINTENANCE MANUAL Wancom Communication and Network technology Ltd Copyright © 2010, All Rights Reserved
  • 3. MUX-2200E - CONTENTS CONTENTS DECLARATION......................................................................................................................... 3 COPYRIGHT AND TRADEMARK ............................................................................................ 3 VERSION HISTORY.................................................................................................................. 3 ABOUT THIS MANUAL ............................................................................................................ 3 Intended Readers .................................................................................................................. 3 Typographical Conventions ................................................................................................... 3 Notes, Notices and Cautions ................................................................................................. 3 Safty Instructions ................................................................................................................... 3 CHAPTER-1 INTRODUCTION ................................................................................................. 3 1.1 Overview .......................................................................................................................... 3 1.2 Features........................................................................................................................... 3 1.3 Specifications ................................................................................................................... 3 1.4 Physical Description ........................................................................................................ 3 CHAPTER-2 INSTALLATION ................................................................................................... 3 2.1 Packing List...................................................................................................................... 3 2.2 Unpacking ........................................................................................................................ 3 2.3 Rack-free installation ....................................................................................................... 3 2.4 Rack Installation............................................................................................................... 3 2.5 Connect to Unit ................................................................................................................ 3 2.6 Initial Power On and Checkout ........................................................................................ 3 CHAPTER-3 CONNECTOR PINOUTS..................................................................................... 3 3.1 RJ45 Connectors (J1-J12)............................................................................................... 3 3.2 V26 Connectors (CHN1-CHN6):...................................................................................... 3 3.3 Serial M&C Port ............................................................................................................... 3 CHAPTER-4 MANAGEMENT................................................................................................... 3 4.1 Through Front Panel ........................................................................................................ 3 4.2 Through the M&C Port ..................................................................................................... 3 4.3 Through Ethernet port...................................................................................................... 3 CHAPTER-5 CONFIGURATION............................................................................................... 3 5.1 Unit Management ............................................................................................................ 3 5.2 Trunk Management.......................................................................................................... 3 5.3 Serial Port Management .................................................................................................. 3 5.4 Voice Port Management .................................................................................................. 3 5.5 E1 Port Management....................................................................................................... 3 -3-
  • 4. MUX-2200E - CONTENTS 5.6 Utility ................................................................................................................................ 3 5.7 Status ............................................................................................................................... 3 CHAPTER-6 MAINTENANCE .................................................................................................. 3 6.1 Disassemble the Major Components............................................................................... 3 6.2 Clean the Chassis............................................................................................................ 3 6.3 Replace the Functional Boards........................................................................................ 3 6.4 Upgrade the Firmware ..................................................................................................... 3 ANNEX-1 CLI COMMAND........................................................................................................ 3 A1.1 Basic Command Formats.............................................................................................. 3 A1.2 CLI Command Set......................................................................................................... 3 ANNEX-2 CONTROL MENU..................................................................................................... 3 ANNEX-3 CABLES ................................................................................................................... 3 A3.1 RS530 DTE SMART SERIAL Cable.............................................................................. 3 A3.2 RS530 DCE SMART SERIAL Cable ............................................................................. 3 A3.3 RS232 DCE SMART SERIAL Cable ............................................................................. 3 A3.4 Serial M&C Cable .......................................................................................................... 3 -4-
  • 5. MUX-2200E - FIGURES FIGURES Figure 1-1. MUX-2200E Integration Service Multiplexer ....................................3 Figure 1-2. Block Diagram ....................................................................................3 Figure 1-4. Indicators on the front panel ...............................................................3 Figure 1-5. Keypad ................................................................................................3 Figure 1-6. LCD display ........................................................................................3 Figure 1-8. Data interface ......................................................................................3 Figure 1-9. Internal structure .................................................................................3 Figure 1-10. System Motherboard .........................................................................3 Figure 1-11. CPU module ......................................................................................3 Figure 1-12. 4-way voice processing module (FXO/Blue)....................................3 Figure 1-13. 4-way voice processing module (FXS/Black)...................................3 Figure 1-14. 4E1 processing module .....................................................................3 Figure 2-1. Status indicators as initial Power On...................................................3 Figure 3-1. The RJ-45 socket.................................................................................3 Figure 3-2. The V26 socket....................................................................................3 Figure 6-1. Disassembling diagram of the top cover of the chassis ......................3 Figure 6-2. Disassembling diagram for the functional modules............................3 Figure 6-3. Installation diagram for the functional modules .................................3 Figure 6-4. Disassembling diagram for the motherboard ......................................3 Figure 6-5. Installation diagram for the motherboard............................................3 Figure 6-6. Software upgrade program interface...................................................3 Figure 6-7. The upgrade program screen – unit scan process................................3 Figure 6-8. The upgrade program screen - uploading process...............................3 -5-
  • 6. MUX-2200E - TABLES TABLES Table 1-1 Indicator list of the front panel ..............................................................3 Table 1-2 Data port list of the rear panel ...............................................................3 Table 3-1. Defintion of the FXO/FXS voice port ..................................................3 Table 3-2. Definition of the E&M voice port.........................................................3 Table 3-3. Definition of the E1/T1 port .................................................................3 Table 3-4. Definition of the Ethernet port..............................................................3 Table 3-5. Definition of the RS-232 interface........................................................3 Table 3-6. Definition of the RS-449 interface........................................................3 Table 3-7. Definition of the V.35 interface ............................................................3 Table 3-8. Definition of the X.21 interface............................................................3 Table 3-9. Definition of the RS-530 interface........................................................3 Table 3-10. Definition of the interface of the serial M&C port .............................3 Table 4-1. Definitions of buttons on the front panel ..............................................3 Table 5-1 System clock source...............................................................................3 Table 6-1. Field Maintenance Record Sheet ..........................................................3 Table 7-1. Port number correspondence table........................................................3 Table 9-1. Definition of the V26 (DTE) converter cable .......................................3 Table 9-2. Definition of the V26 (DCE) converter cable.......................................3 Table 9-3. Definition of the V26 (RS232/DCE) converter cable...........................3 Table 9-4. Definition of the serial M&C cable ......................................................3 -6-
  • 7. MUX-2200E - DECLARATION DECLARATION Thank you for selecting the multiplexer products of Wancom Communication and Network Technology Ltd (hereinafter referred to as “Wancom”). The manual will help you use Wancom Integrated Service Multiplexer products (hereinafter referred to as the “Product” or the “Device”). Be sure to read all data supplied with the Device carefully before installing and using the Product for the first time, especially cautions mentioned in the manual. This will help you use the Product in a better and safer way. Keep the manual appropriately for future reference. The manual does not represent any description to the specifications, software and hardware configurations of the Product. Refer to related agreements, packing lists and product specification and configuration description documents or consult the distributor of the Product for actual specifications and configurations related to the Product. Wancom will not be liable for any damage incurred if the user fails to install, use or maintain the product correctly or according to the instructions and requirements of the product or technicians not authorized by Wancom are allowed to repair or modify the Product. Pictures, figures, graphics and illustrations contained in the manual are only used for explanation and illustration purposes and may different slightly from the real product. Moreover, the actual product specifications and configurations are subject to change according to the demands. The product specifications and configurations are subject to the actual products. The manual does not mean that Wancom has made any warranty regarding its products and services, either express or implied, including but not limited to warranties of applicability, safety, merchantability and fitness for a particular purpose for products recommended in the manual. The warranty commitments for the product and related services shall be subject to the applicable agreement or the service terms and conditions of the product standards. In no event shall Wancom be liable for any damage including but not limited to direct or indirect personal damage, business profit loss, business interruption, business data loss or any other losses incurred thereof during your use or failure to use the Product within the maximum allowable range of laws and regulations. Though we have checked and verified the manual carefully, we do not guarantee that the manual is free from any error or omission. To offer better services, we may improve or modify product software and hardware described and contents contained herein from time to time without notice. Contact us if you find any difference between the actual conditions of the product and the manual during use or you want to acquire the latest information or have any questions and ideas. -7-
  • 8. MUX-2200E - COPYRIGHT AND TRADEMARK COPYRIGHT AND TRADEMARK Wancom mentioned herein is the trademark of Wancom Communication and Network Technology Ltd. Other trademarks and product names mentioned herein are also owned by the original owner of the trademark. The manual is protected by copyright laws and regulations. No person is allowed to duplicate, copy or delete the manual in whole or in part by any means or compile it into computer readable format or save it in the retrievable system or transmit it in a cable or wireless network in any form or translate it into any language. -8-
  • 9. MUX-2200E - VERSION HISTORY VERSION HISTORY Version Version description Compiled by Compiled on 1.0 Original version (applicable for Poppy 2010-08-25 MUX-2200E V1.0) 1.1 Update ”3.1.1.2 E&M Interface” Poppy 2010-10-26 -9-
  • 10. MUX-2200E - VERSION HISTORY This page is intentionally left blank. - 10 -
  • 11. MUX-2200E - ABOUT THIS MANUAL ABOUT THIS MANUAL This manual consists of the following Chapters: Chapter 1: INTRODUCTION - Brief the hardware of the MUX-2200E and its features Chapter 2: INSTALLATION - Instruct users to install the MUX-2200E Chapter 3: CONNECTOR PINOUTS - Describe the definitions of various ports on the front and rear panel Chapter 4: MANAGEMENT - Instruct users to configure and manage the MUX-2200E via the front panel, the monitored port and the Ethernet Chapter 5: CONFIGURATION – Describe the menu operations of the front panel Chapter 6: MAINTENANCE - Instruct users to do routine device maintenance Annex 1: CLI COMMANDS - Provide complete CLI command set. Annex 2: CONTROL MENU - Provide tree-like menu list. Annex 3: CABLES - Describe the definition of the supporting cables for the device Intended Readers This manual contains information useful for setup and management of the MUX-2200E integration service multiplexer. This manual is intended for telecommunication engineers familiar with system installation and network management concepts and terminology. Typographical Conventions Convention Description Bold font It indicates the button of the software interface as well as menu and menu item. For example, click the Start button to select the Run command. [] [ ] represents a command option in the command line mode. Such as <1/TXDR_port number_ [rate], if the command contains the rate value, it means to set the TX data rate of the specified port; if not, it means to inquire about the TX data rate of the specified port. Menu Name Menu Name►Menu Option indicates the menu structure for ►Menu Option the operations on the front panel or the software interface, such as selecting UNIT►DATE command on the front panel, means the DATE menu option under the UNIT menu that is located under the device menu. - 11 -
  • 12. MUX-2200E - ABOUT THIS MANUAL Lucida Console The words in this font indicates input command and information Font feedback by the equipment under the command line mode, of which, the underline represents the keypad command input while italics denotes information feedback from the equipment. Notes, Notices and Cautions To avoid personal injury and property loss, read and follow the following safety precautions carefully before installing this product. The following safety signs will be used in the document or on the product and product package. Safety signs are illustrated as follows: A Note explains some important information, helping you use your equipment in a better way. A Notice indicates potential hazards which may result in hardware damage or data loss and tell you how to avoid such problems. A Caution indicates the potential hazards which may result in property loss, personal injury or even death. - 12 -
  • 13. MUX-2200E - ABOUT THIS MANUAL Safty Instructions Follow these safety guidelines to ensure personal safety and help protect your system from potential damage. Safety Cautions To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, obverve the following precautions. Read the operation labels and follow the instructions of the labels. Do not carry out operations not described in any document of the product. Disassembling the chassis may result in electric shock. Only properly-trained maintenance technicians can handle the assemblies in the chassis. Power off the product and contact your training service provider in case of one of the following circumstances: The power cord, extension wire or plug is damaged. Unknown objects in the chassis The chassis is wet. Falling from a high position may result in product damage. Keep your system far away from the heat source and the radiator. Do not block the cooling vent. Do not drop food or liquid into the chassis. Do not operate the device in a wet environment. Do not attempt to squeeze any object into the opening of the chassis, which may result in a fire or electric shock incurred by short circuit of internal components. Use devices from proper channels only. Wait until the device is cooled properly before removing the cover or touching components inside the chassis. Guarantee that the power source type and power supply cable conform to the product requirements. To prevent electric shock, insert a properly-grounded power outlet system and external power cord. Such cables have three-pin plugs to help guarantee appropriate grounding. Don’t use a plug adaptor or grounding pin with broken power cords. Use three-wire cables with proper grounding plugs if extension wires must be used. Check the capacity of the extension wire and the distribution panel to ensure the total current of all products does not exceed 80% of the nominal current of the extension cord or the power panel. Use UPS to prevent sudden and transient increase and decrease of the power system. - 13 -
  • 14. MUX-2200E - ABOUT THIS MANUAL Ensure firm power cable binding to prevent system cables or power cable from being short-circuited or broken and prevent it from being stepped on or tripped over. Do not change the power cord or plug. General Precautions for Rack-Mounted Products If the rack itself is not stable before installing the device, it may result in personal injury. Therefore, install the supporting assembly inside the rack to ensure that the rack is firm. If a sliding track or tray is available, install the sliding track assembly or tray on the rack first. Ensure that the sliding track and tray can support the device properly. Ensure the rack has been mounted on the floor properly before the rack is installed. Use connectors if there are other racks near it. Always install the loads inside the rack from the bottom up; the heaviest load shall be installed at the bottom of the rack. The AC or DC power supply provided for the rack shall have enough load capacity. The total load of the devices on the rack shall not exceed 80% of the rated load of the power supply system. Ensure the airflow in the rack is unobstructed to facilitate heat elimination of the devices on the rack. Don’t step or stand on any assembly when maintaining other parts. Don’t operate the devices under non-grounding or poorly-grounded conditions. Contact the electrician if the grounding condition is unclear. Protecting against Electrostatic Discharge Electrostatic may damage some sensitive parts inside your system. To prevent electrostatic damage, remove the electrostatic from your body first before touching electronic products, such as the electronic assembly of the micro-processor. You may also touch uncoated metal surfaces on a regular basis to remove electrostatic. In addition, you may take the following measures to prevent ESD damage: Do not take electrostatic sensitive equipments from anti-static packaging material after taking them out of the transport package until you are ready to install them into the components of your system. Be sure to discharge the electrostatic of your body thoroughly before removing the anti-static package. Place electrostatic sensitive equipment into anti-static container or package first for packing when transporting such sensitive equipment. Handle sensitive parts within the electrostatic safe area. Use an anti-static floor mat, anti-static workbench mattress and grounding strap if possible. - 14 -
  • 15. MUX-2200E - CHAPTER-1 INTRODUCTION CHAPTER-1 INTRODUCTION This Chapter gives a brief introduction to the product characteristics, system specification and function features of the MUX-2200E integrated service multiplexer (hereinafter referred to as the “Multiplexer” or the “Equipment”) to help you to have a general understanding of the multiplexer. 1.1 Overview The MUX-2200E is a high-quality integrated service multiplexer product with super system performance launched in 2010 on the basis of the original MUX-2200D integrated service multiplexer, which is specially developed for enterprise and industry users. The MUX-2200E is an integrated multiplexer platform oriented to telecommunication, public security and frontier defenses, bank and finance as well as enterprise application. It supports compressing serial data, voice and IP services into high speed data streams, realizes duplex transmission via communication links such as DDN, microwave and satellite etc, which simplifies the network structure of the communication system and improves the system stability. Figure 1-1. MUX-2200E Integration Service Multiplexer Two versions of the MUX-2200E are available at present, the V1.0 is fully compatible with MUX-2200D, while V2.0 shall provide more expandable capacity. Therefore, users may customize the required one according to their own demand. 1.2 Features High availability The MUX-2200E adopts TDM technology to support converting serial data, voice and IP businesses into high speed data streams, which are transmitted duplex via - 15 -
  • 16. MUX-2200E - CHAPTER-1 INTRODUCTION communication links such as DDN, microwaves and satellites. The transmission is stable with less signal delay. The MUX-2200E provides EIA-232/EIA-422/V.35/G.703/E1 interface, Analog voice and Ethernet, which can support a variety of data, voice or video services; support the trunk data rate up to 20Mbps. The MUX-2200E V1.0 with standard configurations are fully compatible with MUX2200D. Figure 1-2. Block Diagram High reliability The MUX-2200E is configured with two trunk ports with 1: 1 redundant backup. Two hardware ports adopt independent data processing chips. If one trunk port fails or is damaged, the other one may be used. High expansibility The MUX-2200E adopts modular design, which takes into account the expansion requirement from the beginning of the design. Through simple hardware upgrading and functional module replacement, it can be expanded up to eight voice channels or eight E1 channels, two groups of independent network connection, and video expansion. High manageability Users may configure and monitor MUX-2200 through the front panel, serial M&C port and Ethernet port. The firmware version may be updated via the serial M&C port or Ethernet port conveniently and rapidly. - 16 -
  • 17. MUX-2200E - CHAPTER-1 INTRODUCTION 1.3 Specifications Trunk port Interface: EIA-422/EIA-232/V.35/LVDS Type: V26 with DB25 converter cable Data rate: 9.6kbps to 20Mbps synchronous (step by 100bps) Quantity: 2 ports, adopting 1:1 redundant configuration Serial port Interface: EIA-422/EIA-232/V.35/LVDS Type: V26 with DB25 converter cable Data rate: 1.2kbps -10Mbps synchronous (step by 100bps) or 300bps --115.2kbps asynchronous Quantity: 4 E1 port Interface: G.703 /G.704 Type: RJ45 Data rate: 64Kpbs × n (n≤32) Quantity: 4 (Support up to 8 ports optionally) Voice port Interface: FXS, FXO and E&M Type: RJ45 Data rate and Protocol: Coding: G.711 (64k), G.723.1 (5.3k/6.3k) Echo cancellation: G.168 Quantity: 4 (Support up to eight ports optionally) Ethernet port Interface: IEEE802.3 Type: RJ45 Data rate: 10/100M Quantity: 2 groups, 2 ports available for each group (Support up to 4 ports each group) Expansion slot Expandable video port M&C Provide the M&C port to facilitate monitor and control Provide CLI and Telnet management interface. - 17 -
  • 18. MUX-2200E - CHAPTER-1 INTRODUCTION Operation method and status display 6-key keypad on the front panel with LCD Monitor and control via serial M&C port Monitor and control via Ethernet port Status indicator TX and RX Indication for Trunk port Synchronous status indication for Trunk port TX and RX Indication for serial ports Connection status for Ethernet ports Synchronous and carrier indication for E1 ports Off-hook or ringing indication for analog voice interface Environments Operating temperature: 0℃ ~ +60℃ Operating humidity: 0 ~ 90% Storage temperature: -40℃ ~ +70℃ Power supply Working voltage: 85V ~ 240V AC, -48V DC (optional) Consumption: less than 25W Physical specification Net weight: 3.1 kg Dimension(W×D×H): 482mm×355mm×44mm 1.4 Physical Description This part gives a brief introduction to the appearance and internal structure of the MUX-2200E chassis. Refer to Chapter-6 MAINTENANCE contained herein for related product installation and disassembling contents. All pictures contained in this part are for reference only. Specific products are subject to the real objects. 1.4.1 Outline Structure The MUX-2200E integration service multiplexer is constructed as a 1RU-high rack mounting chasiss, which can be free-standing if desired. Rack handles at the front facilitate removal from and placement into a rack. - 18 -
  • 19. MUX-2200E - CHAPTER-1 INTRODUCTION 1.4.1.1 Front Panel Figure 1-3. Front Panel View Figure 1-3 shows the front panel of the MUX-2200E. The front panel features (from left) the following components: Serial M&C port Light-Emitting-Diode(LED) indicators Keypad Liquid-Crystal-Display(LCD) Power switch - Indicators Figure 1-4. Indicators on the front panel The front panel of the MUX-2200E includes the following indicators: Indicator Color Function description PWR Green Always on, indicating the power supply works normally. TX Green Always on or flickering, indicating the trunk port is transmitting data RX Green Always on or flickering, indicating the trunk port is receiving data SYNC Green Always on, indicating the trunk is receiving data normally. DS Red Red light always on indicates the unit is starting during start-up. Red light always on or flickering indicates the unit works abnormally after start-up is completed. TX1-TX8 Green On or flickering indicates the serial port CH1 is transmitting data RX1-RX8 Green On or flickering indicates the serial port CH1 is receiving data Table 1-1 Indicator list of the front panel - 19 -
  • 20. MUX-2200E - CHAPTER-1 INTRODUCTION - Keypad The MUX-2200E adopts 6-key layout, including the , , and direction keys as well as the ENTER key for confirmation and the CLEAR key for cancel or return. Figure 1-5. Keypad - LCD The LCD of the front panel of the MUX-2200E is an active showing two lines of 20-character each, and produces a yellow green backlight. “▲” is used to prompt the current menu items or edit position. Figure 1-6. LCD display 1.4.1.2 Rear Panel Figure 1-7. Rear Panel View Figure 1-7 shows the the following components: Power interface and fuse Expansion slot RJ45 ports V26 serial ports Ground pole - Data Interface Figure 1-8. Data interface Figure 1-8 shows the connectors installed in the rear panel of the MUX-2200E. Each - 20 -
  • 21. MUX-2200E - CHAPTER-1 INTRODUCTION connector is described in detail in Chapter-3 “CONNECTOR PINOUTS”. Extenal cables are attached to these connectors. A hardware port of the same type as RJ45 on the rear panel may be set as different service type by changing the functional module board inside the chassis. Connnector Name Default Optional Remarks V26 port CHN5 Online trunk Standby trunk Only one online trunk CHN6 Standby trunk Online trunk port can be selected CHN1 Serial Data CHN2 Serial Data If LAN2 enabled, CHN2 will be off automatically CHN3 Serial Data CHN4 Serial Data RJ45 port J1-J4 Voice E1 Need to replace J5-J8 E1 Voice/Ethernet functional module boards J9/J11 LAN Group1 Default ON J10/J12 LAN Group2 Default OFF. Table 1-2 Data port list of the rear panel 1.4.2 Internal Structure Figure 1-9. Internal structure The MUX-2200E adopts modular design. The chassis mainly contains the following components. E1 Processing Module; Voice Processing Module; - 21 -
  • 22. MUX-2200E - CHAPTER-1 INTRODUCTION CPU Module; System Motherboard; Keypad and Display Module; Power Supply Module; Ventilating Fan; M&C Interface Module 1.4.2.1 Keypad and Display Module The Keypad and Display Module consists of a keypad input interface circuit, a drive circuit for LCD and indicators. Any keypad operation will be sent to the system motherboard via the module while feedback message from the system will be displayed on the LCD through the module, as well as affect the status of the indicators. 1.4.2.2 System Motherboard The system motherboard is the core component of the MUX-2200E, which has the following functions: Provide Wiring and logic connections of other modules inside the chassis; Provide FPGA to achieve a multiplexing function; Provide interface circuits for all input and output ports; Provide all input and output connectors on the rear panel, including 6 V26 ports and 12 RJ45 ports; Provide sockets for all sub-function modules, including CPU module socket and functional module sockets; Provide Ethernet bridge and switching circuit; Figure 1-10. System Motherboard (with CPU module, 4E1 module and 4-way voice module) - 22 -
  • 23. MUX-2200E - CHAPTER-1 INTRODUCTION 1.4.2.3 Common Functional Modules - CPU Module Figure 1-11. CPU module - Voice Processing Module The voice processing module is responsible for voice compression to achieve FXO, FXS and E&M analog voice interface functions, provide reliable lightning prevention and anti-static protection. The analog voice signal line provides 180V of overvoltage protection and 90mA over-current protection (the breakdown voltage is more than 250V). Each interface provides two indicators, which are driven by CPU. Functions of the following lights are shown below: Yellow: Glittering, indicating ringing signals Green: Always on, indicating the telephone is in use. The voice processing module is classified as 2 kinds, which support FXO interface and FXS interface respectively. Figure 1-12. 4-way voice processing module (FXO/Blue) Figure 1-13. 4-way voice processing module (FXS/Black) - 23 -
  • 24. MUX-2200E - CHAPTER-1 INTRODUCTION - E1 Processing Module The E1 processing module is responsible for E1/T1 interface functions, providing lightning and anti-static protection. Provide 6V over-voltage protection and 90mA over-current protection (the breakdown voltage exceeds 250V). Each interface provides two indicators (built in RJ45 interface), which are driven by the CPU board. Lights are defined as follows: Yellow: Flickering or always on indicates the carrier is losing lock. Green: If the light is on, it indicates the frame has been synchronous. Figure 1-14. 4E1 processing module - 24 -
  • 25. MUX-2200E - CHAPTER-2 INSTALLATION CHAPTER-2 INSTALLATION This Chapter introduces the installation, cable connection and power-on procedure. 2.1 Packing List The standard MUX-2200E packing box contains the following items: MUX-2200E chassis ; AC power cord ; Two V26 interface converter cable; One serial M&C cable; Operation and Maintenance Manual (CD-ROM); 2.2 Unpacking Check the appearance of the packing box carefully to ensure the original package of the equipment is neither worn nor damaged and free from water and foreign objects. Place the packing box on a stable plane at the correct position. Uncover the upper transparent tape sealing of the packing box with a paper knife. Take out the equipment together with the anti-shock foamed plastic. Take out the equipment from the anti-static packing bag. Check whether all items are complete carefully with reference to the packing list contained in this Chapter and have an appearance inspection to ensure the equipment and parts are free from any damage. Keep the original packing box and the packing materials in the box temporarily, which may be used for equipment transport and packing once again. Contact the distributor to make up the deficiency in case of any shortage of the above contents in the open-case inspection. 2.3 Rack-free installation Tear off the protective film outside the chassis. Place the equipment at the selected installation position. Connect the power cord and other signal cables. Ensure that the equipment is properly grounded. - 25 -
  • 26. MUX-2200E - CHAPTER-2 INSTALLATION More than 20cm of distance must be provided at the left side (air inlet) and the right side (exhaust outlet) of the chassis for heat radiation. At least 50cm of distance must be provided at the back side of the chassis to facilitate feeder connection and maintenance; moreover, not less than 50cm of distance must be provided at the front side of the chassis to facilitate the operations of the front panel. If the equipment is installed in a room without an air purification and filter system or non-professional communication room, the chassis is recommended to be installed 1 meter above the ground to prevent dust and foreign objects from being absorbed into the chassis after long-term operation. Equipment shall not be stacked exceed 2 layers, and the overall bearing of the top cover of the equipment shall not exceed 10kg. Ensure the surface of the cabinet, table or support of the equipment placed are flat and the overall support is stable; the overall weight of all equipments shall not exceed 50% of the bearing of the cabinet, the table or the support. 2.4 Rack Installation Install the tray or bracket at the required rack position. Tear off the protective film outside the chassis. Place the equipment on the rack tray and fasten the front panel. Connect the power cord and other signal cables. Connect the grounding line to the equipment from the grounding copper bar of the cabinet. It is recommended that the equipment be installed with a 1U space in the rack. If the equipment does need to be stacked, it shall not exceed 2 layers. 2.5 Connect to Unit The MUX-2200E may need to use the following (partial) cables: Power cord Grounding wire Serial cable for Trunk port (including V26 converter cables) Serial cables for serial port (including V26 converter cable, if required) - 26 -
  • 27. MUX-2200E - CHAPTER-2 INSTALLATION Telephone line E1 line LAN Cable Serial M&C cable The V26 converter cables, serial M&C cable and power cord are standard configurations with MUX-2200E. Other cables shall be fabricated on the field by users or professional installation personnel. Refer to Chapter-3 “CONNECTOR PINOUTS” for specific port definitions. 2.6 Initial Power On and Checkout Read and follow all precautions mentioned in the safety instructions. Ensure the MUX-2200E has been installed in line with the prompts of this section and complete cable connection work. Turn on the power switch on the front panel; the following information will be displayed as follows: Wait for the equipment to complete the power-on self-check. The following information will be displayed on the LCD: The status indicators of the front panel show below before the equipment has not been configured: Figure 2-1. Status indicators as initial Power On - 27 -
  • 28. MUX-2200E - CHAPTER-2 INSTALLATION This page is intentionally left blank. - 28 -
  • 29. MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS CHAPTER-3 CONNECTOR PINOUTS 3.1 RJ45 Connectors (J1-J12) Figure 3-1. The RJ-45 socket J1-12 on the rear panel may be configured as the voice, E1/T1 or Ethernet ports according to different functional modules installed inside the chassis. 3.1.1 Analog Voice Ports J1-J4 are default analog voice ports and J5-J8 may also be configured as analog voice ports after installing appropriate functional module. 3.1.1.1 FXO/FXS Interface Pin Signal name 4 TIP 5 RING Table 3-1. Defintion of the FXO/FXS voice port 3.1.1.2 E&M Interface Pin Signal name Signal direction 1 SG Input 2 E Input 3 RR Input 4 Ring Output 5 TIP Output 6 TR Input 7 M Output 8 SB Output Table 3-2. Definition of the E&M voice port - 29 -
  • 30. MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS 3.1.2 E1/T1 Interface J5-J8 are default E1/T1 ports and J1-J4 may also be configured as E1/T1 ports after necessary functional modules are installed. The pin assignment is defined as follows: Pin Signal name Signal direction 1 RX_TIP Input 2 RX_RING Input 4 TX_TIP Output 5 TX_RING Output Table 3-3. Definition of the E1/T1 port 3.1.3 Ethernet Interface J5-J12 may be configured as Ethernet ports, of which J5, J7, J9 and J11 belong to LAN1 and J6, J8, J10 and J12 belong to LAN2. LAN1 and LAN2 are separated from each other. Only J9 and J11 are active under the default condition. The pin assignment is defined as follows: Pin Signal name Signal direction 1 RX+ Input 2 RX- Input 3 TX+ Output 6 TX- Output Table 3-4. Definition of the Ethernet port 3.2 V26 Connectors (CHN1-CHN6): Figure 3-2. The V26 socket The ports (CHN1-CHN6) on the rear panel are serial ports, 4 ports (CHN1-CHN4) are serial data ports, 2 ports (CHN5 and CHN6) are trunk ports. The pin assignment is defined as follows. - 30 -
  • 31. MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS All undefined pins must be kept floating 3.2.1 RS-232 Interface Pin Signal name Signal direction 21 TXD Output 22 TXCE Output 23 TXC Input 24 RXC Input 13 RXD Input 6 DCD Input 7 DTR Output 8 RTS Output 11 CTS Input 12 DSR Input 26 GND -- Table 3-5. Definition of the RS-232 interface 3.2.2 RS-449 Interface Pin Signal name Signal direction 1 TXDa Output 2 TXCEa Output 3 TXCa Input 4 RXCa Input 5 RXDa Input 6 DCDa Input 7 DTRa Output 8 RTSa Output 9 RTSb 10 CTSb 11 CTSa Input 12 DSRa Input 14 TXDb Output 15 TXCEb Output 16 TXCb Input 17 RXCb Input 18 RXDb Input 19 DCDb Input - 31 -
  • 32. MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS 20 DTRb Output 25 DSRb Input 26 GND -- Table 3-6. Definition of the RS-449 interface 3.2.3 V.35 Interface Pin Signal name Signal direction 1 TXDa Output 2 TXCEa Output 3 TXCa Input 4 RXCa Input 5 RXDa Input 6 DCD Input 7 DTR Output 8 RTSa Output 11 CTS Input 12 DSR Input 14 TXDb Output 15 TXCEb Output 16 TXCb Input 17 RXCb Input 18 RXDb Input 26 GND -- Table 3-7. Definition of the V.35 interface 3.2.4 X.21 Interface Pin Signal name Signal direction 1 TXDa Output 4 RXCa Input 5 RXDa Input 6 DCDa Input 7 DTR Output 8 RTS Output 11 CTS Input 12 DSR Input 14 TXDb Output 17 RXCb Input 18 RXDb Input 26 GND -- - 32 -
  • 33. MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS Table 3-8. Definition of the X.21 interface 3.2.5 RS-530 Interface Pin Signal name Signal direction 1 TXDa Output 2 TXCEa Output 3 TXCa Input 4 RXCa Input 5 RXDa Input 6 DCDa Input 7 DTRa Output 8 RTSa Output 9 RTSb Output 10 CTSb Input 11 CTSa Input 12 DSRa Input 14 TXDb Output 15 TXCEb Output 16 TXCb Input 17 RXCb Input-- 18 RXDb Input-- 19 DCDb Input-- 20 DTRb Output 25 DSRb Input 26 GND -- Table 3-9. Definition of the RS-530 interface 3.2.6 V26 Conversion Cable The product package contains V26-DB25 converter cables. Refer to related contents of Annex-3 “CALBES” for their definitions. 3.3 Serial M&C Port The serial M&C port is located at the left side of the front panel, which is in the form of a RJ45 port. The pin assignment is defined as follows: Pin Signal name Signal direction 1 RTS 2 DTR - 33 -
  • 34. MUX-2200E - CHAPTER-3 CONNECTOR PINOUTS 3 TXD Output 4 GND 5 GND 6 RXD Input 7 DSR 8 CTS Table 3-10. Definition of the interface of the serial M&C port The serial M&C port does not provide flow control signal. If connected equipment needs flow control signals, short-circuit RTS and CTS, DTR and DSR signal lines of the equipment port. The product package provides serial M&C cables compatible with the cable of the Console port of Cisco router. Refer to the related contents contained in Annex-3 “CABLES” for its definition. - 34 -
  • 35. MUX-2200E - CHAPTER-4 MANAGEMENT CHAPTER-4 MANAGEMENT The MUX-2200E may be configured through the front panel, the M&C port and Ethernet port. This Chapter will introduce them respectively. See Chapter-5 “CONFIGURATION” for the detailed configuration methods and procedures. 4.1 Through Front Panel 4.1.1 Menu Hierarchy The front panel of the MUX-2200E provides all function settings of local units. To manage such functions and facilitate users’ understanding and memorization, the control menu system of the MUX-2200E may be classified into the followings: Category - Root menu, including main function category Function - Secondary menu, including all function of a category Parameter - current value and option of a certain function For complete menu list, see Annex-2 “CONTROL MENU”. 4.1.2 Buttons Button Button Function Switch menu option under menu mode; change parameter modification position under parameter edition mode. Modify parameters or select parameter from options under the parameter edition mode. ENTER Confirm the current menu selected to enter the submenu or display the current value of the parameter under the menu mode. Enter the parameter edition mode under the parameter display mode. Confirm the parameter value modification under the parameter edition mode. CLEAR Return to the upper menu by pressing it under menu selection; Cancel the modification of the current parameters and restore the original setting under edition means. Table 4-1. Definitions of buttons on the front panel - 35 -
  • 36. MUX-2200E - CHAPTER-4 MANAGEMENT 4.1.3 Menu Operations 4.1.3.1 Standby Screen The standby screen is as follows: Press the ENTER key to enter the Category screen under the Standby screen. 4.1.3.2 Category Screen The first line of the Category screen displays SELECT, prompting that the current position is the root menu; the second line indicates all category items. “▲” will stop at the current classified menu item position. Press the key or key to move the cursor (“▲”signal) on the second line of the screen to select specified category. Press the ENTER key to enter the specified function group (secondary menu). Press the CLEAR key to return to the standby screen. 4.1.3.3 Function Screen The first line of the Function screen displays the current category name, prompting the current position is the secondary menu; the second line indicates all function items contained in the category. “▲” will stop at the current function position. Press the key or key to move the cursor (“▲”signal) on the second line of the screen to select the specified function. Press the ENTER key to enter the Parameter Display screen to view the current configurations. Press the CLEAR key to return to the Category screen. In some Function screen, the first line indicates that the bracket behind the category name contains the specified port number. - 36 -
  • 37. MUX-2200E - CHAPTER-4 MANAGEMENT 4.1.3.4 Parameter Display Screen The first line of the Parameter Display screen displays the full name of the parameter and the second displays the current parameter value. Press the ENTER key to enter the Parameter Modification screen. Press the CLEAR to return to the Function screen. For some Parameter Display screen, the first line indicates that the bracket behind the parameter name contains the current port number specified. 4.1.3.5 Parameter Modification Screen The first line of the Parameter Modification screen displays the full description of the parameter and the second line displays the current value. Press the key or key to move the cursor on the second line of the screen (“▲”signal) and select editable position. Press the key or key select the current parameter option or change parameter value at current editable position. Press the ENTER key to confirm parameter modification and return to the Parameter Display screen. Press the CLEAR to cancel parameter modification and return to the Parameter Display screen directly. For some Parameter Display screen, the first line indicates that the bracket behind the parameter name contains the current port number specified. 4.2 Through the M&C Port The front panel of the MUX-2200E provides an RS-232 serial port of RJ45 type as the M&C port, through which the computer can be used to monitor unit status and update parameter configurations of the MUX-2200E. To connect to the MUX-2200E through the serial M&C port, the following shall be prepared: Terminal or computer with a serial port Serial M&C cable supplied with the equipment - 37 -
  • 38. MUX-2200E - CHAPTER-4 MANAGEMENT 4.2.1 Connection Procedures Follow the following procedures to use the M&C port to monitor the equipment: Plug the RJ45 cable connector of the M&C cable into the M&C port of the front panel of the MUX-2200E. Connect the 9-pin cable head at the other end of the M&C cable to the serial port of the computer. To prevent computer serial interface or equipment M&C port from being damaged, it is recommended to plug/unplug the M&C cable in case of equipment outage. Run a terminal simulation software (ie. Hyperterminal) on the computer and set the following port parameters: Select correct serial port; Set data rate to 115,200bps; Set data format to 8 data-bits and 1 stop-bit, without Parity and flow control; Set the simulation mode as AUTO. Select “Terminal Keys” for the “Function, arrow and ctrl keys act as” instead of “Windows keys”. Connect the power cord of the MUX-2200E and turn on the power switch of the front panel, the front panel will display: The computer terminal software will display system boot information. U-Boot 1.3.2 (May 6 2010 - 13:28:05) MPC8272 Reset Status: External Soft, External Hard MPC8272 Clock Configuration - Bus-to-Core Mult 3.5x, VCO Div 2, 60x Bus Freq 30-85 , Core Freq 100-300 - dfbrg 1, corecnf 0x1e, busdf 3, cpmdf 1, plldf 0, pllmf 3, pcidf 7 - vco_out 400000000, scc_clk 100000000, brg_clk 25000000 - cpu_clk 350000000, cpm_clk 200000000, bus_clk 100000000 - pci_clk 25000000 CPU: MPC8272 (HiP7 Rev 14, Mask 1.0 1K50M) at 350 MHz Board: Motorola MPC8272ADS DRAM: 64 MB FLASH 1: 8 MB …… - 38 -
  • 39. MUX-2200E - CHAPTER-4 MANAGEMENT …… Loading system parameter...... WANCOM Communication & Networks Technology Ltd. MUX2200E version 1.0.0165 Firmware version 0.1 SCCrun_Flag [0] =1 hdlc0: Carrier detected SCCrun_Flag [2] =1 hdlc1: Carrier detected SCCrun_Flag [3] =1 hdlc2: Carrier detected voice bandwidth = 292000 Program download successful! chip1 download successful! times=1 error=0 LOCAL> When the boot procedure is completed, the front panel will display: 4.3 Through Ethernet port Ethernet port J9 and J11 on the rear panel of the MUX-2200E may be used for equipment configuration and management. The computer may manage the MUX-2200E through the Ethernet port. The following shall be prepared: Terminal or computer with network interface card Standard straight-connection cable 4.3.1 Connection Procedures To use the Ethernet port to monitor the equipment, follow the following procedures: Connect the power cord of the MUX-2200E and turn on the power switch on the front panel, and wait for completion of the system boot procedure until the front panel displays: Use the LAN cable to connect the computer Ethernet port to Port 9 or Port 11 on the rear panel of the MUX-2200E. Set the equipment network address through the front panel menu- UNIT►IPADDR, - 39 -
  • 40. MUX-2200E - CHAPTER-4 MANAGEMENT such as 192.168.1.1_24. The attribute of the computer network interface card are configured as follows: IP address: 192.168.1.x, x ranges from 2 to 254. Subnet Mask: 255.255.255.0 Default gateway: Null Execute Start►Run on the computer and input cmd command to enter the MS-DOS command line mode. Enter the command: telnet [Unit IP address] After connecting successfully, the screen will pop up: LOCAL> - 40 -
  • 41. MUX-2200E - CHAPTER-5 CONFIGURATION CHAPTER-5 CONFIGURATION Users may have full configurations and management for the MUX-2200E via the keypad and LCD on the front panel. 5.1 Unit Management This section covers some general settings for the equipment, including settings of the M&C address, IP address and time and date as well as serial number and software version inquiry. The operations of the front panel concentrate on the UNIT function menu. 5.1.1 Set the M&C Address Set the M&C Address for the MUX-2200E via menu UNIT►ADDR. The M&C Address is selected from 0 to 255 (set 1 as default) via and . The screen display is as follows: 5.1.2 Set the IP Address Set the IP address and mask for the MUX-2200E via menu UNIT►IPADDR (set 192.168.1.1 as default IP address and 255.255.255.0 as default subnet mask). The subnet mask is set via a decimal digit from 0 to 32. The masks used are as follows: Code Subnet Mask 8 255.0.0.0 16 255.255.0.0 24 255.255.255.0 Adjust the cursor position using keys and modify values using keys. The screen display is as follows: - 41 -
  • 42. MUX-2200E - CHAPTER-5 CONFIGURATION 5.1.3 Set the Date Set the date and time for the MUX-2200E via menu UNIT►DATE. The screen display is as follows: 5.1.4 Show the Serial Number The serial number of the MUX-2200E may be inquired about via menu UNIT►SN. The screen display is as follows: 5.1.5 Enable/Disable the LAN Group 2 Enable/disable the LAN Group 2 via menu UNIT►LAN2. Use keys to select ON or OFF (set OFF as default). The screen display is as follows: Set LAN2 as ON to enable it, the serial Port CHN2 will be off automatically. 5.1.6 Set the Screen Backlight Turn on or off the LCD backlight of the front panel of the MUX-2200E via menu UNIT►BACKLIGHT. Use the keys to select ON (backlight ON) or OFF (backlight off). The screen display is as follows: When the BACKLIGHT is set as ON, any button operation will trigger the backlight of the LCD; No button operation lasts for more than 20 seconds, the backlight of the screen will turn off automatically until next button operation. - 42 -
  • 43. MUX-2200E - CHAPTER-5 CONFIGURATION 5.2 Trunk Management This section covers the configuration for CHN5 or CHN6 trunk ports. The Operations on the front panel concentrate on the TRUNK function menu. 5.2.1 Select the Online Trunk Port Two hardware ports on the rear panel of the MUX-2200E are available as trunk ports. Select one as the online port and the other will become the backup port automatically. Use the keys to select one of two ports (CHN5 and CHN6) as the online port via menu TRUNK►PORT. The screen display is as follows: The selected trunk port number will appear in the bracket of the first line on the TRUNK function screen. 5.2.2 Set the TX Data Rate Theoretically the MUX-2200E supports a TX data rate of up to 20Mbps. The actual TX data rate will be an integral multiple of the step rate of the multiplexer. Use the keys to adjust the cursor positions via menu TRUNK►TXDR and press the keys to modify the value of the cursor position. The TX data rate is k times, which ranges from 0 to 2048, of the step rate. The screen display is as follows: Related settings: Refer to 5.6.2 “Set the Step Rate”. 5.2.3 Set the TX Clock Mode The TX clock of the trunk port of the MUX-2200E may be set to the following three kinds of clock modes. The MUX-2200E is at the DTE side in the figure below. TT mode - TX data will be synchronized with the TT clock at the DTE side. DCE equipment will acquire a clock from the DTE side. - 43 -
  • 44. MUX-2200E - CHAPTER-5 CONFIGURATION DTE SD DCE TT ST RD RT ST mode - TX data will be synchronized with the ST clock at the DCE side. DTE equipment will acquire a clock from the DCE side. DTE SD DCE TT ST RD RT RT mode - TX data will be synchronized with the RX clock. DTE SD DCE TT ST RD RT Adjust the TX clock mode via menu TRUNK►TXCM. Press the keys to select TT, ST or RT. The screen display is as follows: When the clock at the trunk port is set as TT clock, the MUX-2200E may select either built-in high-precision clock or the serial port clock as the clock source. Related settings: Refer to 5.6.1“Set the Clock Source”. 5.2.4 Set the TX Clock Polarity Press the key or the key to adjust the TX clock polarity at the trunk port via menu TRUNK►RXCP. Select NORMAL - TX data will be updated at the clock falling edge, and the equipment at the remote side shall sample data at the clock rising edge Select INVERT - TX data will be updated at the clock rising edge, and the equipment at the remote side shall sample data at the clock falling edge). The screen display is as follows: - 44 -
  • 45. MUX-2200E - CHAPTER-5 CONFIGURATION 5.2.5 Set the RX Data Rate Via menu TRUNK►RXDR, press the key or the key to adjust the cursor position and press the key or the key to modify the value at the cursor position. The RX data rate is k times, which ranges from 0 to 2,048, of the step rate. The screen display is as follows: Related settings: See 5.6.2 “Set the Step Rate”. 5.2.6 Set the RX Clock Polarity Via menu TRUNK►RXCP, Press the key or the key to adjust the RX clock polarity of the trunk port. Select NORMAL - (normal polarity) Sample and receive data at the clock rising edge Select INVERT - (opposite polarity) Sample and receive data at the clock falling edge The screen display is as follows: 5.2.7 Set the Trunk Loopback Active the trunk loopback function via menu TRUNK►LPBK. It is often used for system testing. Press the key or the key to select NORMAL (loopback OFF) or LOOPBACK (loopback ON). - 45 -
  • 46. MUX-2200E - CHAPTER-5 CONFIGURATION The screen display is as follows: Related setting: Refer to 5.3.8 “Set the Port Loopback” 5.3 Serial Port Management This section covers the configuration for serial ports (CHN1-CHN4). Operations on the front panel concentrate on the SERIAL function menu. 5.3.1 Select the Current Serial Port Four hardware ports CHN1-CHN4 of the MUX-2200E work as the serial ports. Users may configure any one or several serial ports according to link requirements; The function “Select the current serial port” can be realized via menu SERIAL►PORT. Press the key or the key from CHN1 to CHN4 to select any one port as the current specified port (here the specified port selected is CHN1). The screen display is as follows: Selected serial port number will appear in the bracket of the first line displayed on the SERIAL Function screen. The screen display is as follows: 5.3.2 Set the TX Data Rate Theoretically the serial port of the MUX-2200E supports up to a TX data rate of 10Mbps. The TX data rate actually set shall be integral multiple of the step rate of the multiplexer. Use the key or the key to adjust the cursor position and use the key or the key to modify the value where the cursor is located via menu SERIAL►TXDR. The TX data rate is k times, which ranges from 0 to 2048, of the step rate. The screen display is as follows: - 46 -
  • 47. MUX-2200E - CHAPTER-5 CONFIGURATION Related setting: See 5.6.2 “Set the Step Rate” 5.3.3 Set the TX Clock Mode The TX clock of the serial port of the MUX-2200E may be set to the following three kinds of clock modes. The MUX-2200E constitutes the equipment at the DCE side in the diagram below. TT mode - TX data will be synchronized with the clock at the DTE side, and the DCE equipment will acquire clock from the DTE side. ST mode - TX data will be synchronized with the clock at the DCE side. The DTE equipment will acquire a clock from the DCE side. RT mode - The TX clock will be synchronized with the RX clock. Adjust the TX clock mode via menu SERIAL►TXCM. Press the key or the key to select TT, ST or RT. The screen display is as follows: When the serial port clock is set as the ST mode, the MUX-2200E may select the built-in high precision clock or other serial port clock as the clock source. Related setting: See 5.6.1 “Set the Clock Source.” - 47 -
  • 48. MUX-2200E - CHAPTER-5 CONFIGURATION 5.3.4 Set the TX Clock Polarity Adjust the TX clock polarity of the trunk port via menu SERIAL►TXCP. Press the key or the key to select NORMAL or INVERT. The screen display is as follows: 5.3.5 Set the RX Data Rate Use the key or the key to adjust the position of the cursor via menu SERIAL►RXDR and use the key or the key to modify the value where the cursor is located. The RX data rate is k times, which ranges from 0 to 2048, of the step rate. The screen display is as follows: Related setting: See 5.6.2 “Set Step Rate” 5.3.6 Set the RX Clock Polarity Adjust the RX clock polarity of the trunk port via menu SERIAL►RXCP. Press the key or the key to select NORMAL or INVERT. The screen display is as follows: 5.3.7 Set the Async Mode Set the async mode of the serial port via menu SERIAL►ASYNC. Users may use the key or the key to select ON (async mode) or OFF (sync mode). The screen display is as follows: 5.3.8 Set the Port Loopback The serial port loopback may be enabled via menu SERIAL►LPBK. It is often used for system testing. Press the key or the key to select OFF (loopback off) or ON (loopback on). - 48 -
  • 49. MUX-2200E - CHAPTER-5 CONFIGURATION The screen display is as follows: Related setting: See 5.2.7 “Set the Trunk Loopback” 5.4 Voice Port Management This section covers the configuration for voice ports (J1-J4). Operations on the front panel concentrate on the VOICE functional classification menu. 5.4.1 Select the Current Voice Port The MUX-2200E provides four hardware ports (J1~J4) as voice ports. Via menu VOICE►PORT, press the key or the key to select one as the currently specified configuration port (here select J1 as the specified port). The screen display is as follows: The current voice port number selected will appear in the bracket of the first line displayed on the voice function screen. The screen display is as follows: 5.4.2 Enable/Disable the Voice Port Via menu VOICE►ENABLE, press the key or the key to enable or disable current voice port. The screen display is as follows: - 49 -
  • 50. MUX-2200E - CHAPTER-5 CONFIGURATION 5.4.3 Set the Fax Lines Via menu VOICE►FAXLINE, press the key or the key to select a number from 1 to 4 to set the maximum fax lines (here the fax line number is set as 1). The screen display is as follows: 5.4.4 Set the Voice Coder Via menu VOICE►CODER, press the key or the key to select G.711 or G.723.1 to set the voice coder for the current voice port (here it is set as G.711). The screen display is as follows: 5.4.5 Set the Voice Volume Via menu VOICE►VOL, press the key or the key to modify from -32dB to +31dB to adjust the volume for the current voice port (here the default setting of the volume is 0dB). The screen display is as follows: 5.4.6 Set the DTMF Level Via menu VOICE►DTMF, press the key or the key to modify it from -32dB to +3dB and adjust the DTMF Level for the current voice port (here the default setting of the volume is -4dB).The screen display is as follows: 5.5 E1 Port Management This section covers the configuration for the E1 ports (J5-J8). Operations on the front - 50 -
  • 51. MUX-2200E - CHAPTER-5 CONFIGURATION panel concentrate on the E1 function menu. 5.5.1 Select the Current E1 Port The MUX-2200E with standard configurations provides 4 hardware ports (J5-J8) as E1 ports. Via menu E1►PORT, press the key or the key to select any port as the currently specified configuration port from J5 to J8 (here the current port selected is J5). The screen display is as follows: The currently selected E1 port number will appear in the bracket of the first line displayed on the E1 function screen after completing such setting. The screen display is as follows: 5.5.2 Enable/Disable the E1 Port Via menu E1►TYPE, press the key or the key to select OFF/E1 to Enable/Disable the current E1 port . The screen display is as follows: 5.5.3 Enable/Disable the CRC Function Via menu E1►CRC, press the key or the key to select ON/OFF to Enable/Disable the CRC function for the current E1 port (here the default setting is OFF) . The screen display is as follows: 5.5.4 Set the Time Slots Via menu E1►SLOT, set the time slot of the current E1 port. Press the key or the key to adjust the cursor position to select the assigned time slot, and press the key or the key to select 1 or 0. - 51 -
  • 52. MUX-2200E - CHAPTER-5 CONFIGURATION The time slots parameter is a 32-bit binary number, which represents Time Slot 0, 1, …, 31 of E1 from left to right. Each bit distinguishes the status of the time slot: 1 (indicates that the time slot is occupied) or 0 (indicates that the time slot is not occupied). As the left first Time Slot is set to 0, it indicates the current port support non-framing data stream. The screen display is as follows: 5.5.5 Set the Sync Mode Via menu E1►SYNC, press the key or the key to select ON or OFF and set the sync mode of the current E1 port (here the default setting is ON). The screen display is as follows: 5.5.6 Set the Impedance Via menu E1►IMPED, press the key or the key to select 75 ohm or 120 ohm and set the impedance of the current E1 port (here the default setting is 120 ohm). The screen display is as follows: 5.5.7 Inquire the TX Data Rate Inquire about the TX data rate of the specified E1 port via menu E1►TXDR, the parameter will be modified automatically according to the SLOT setting. The screen display is as follows: Related setting: See 5.5.4 “Set the Time Slots” - 52 -
  • 53. MUX-2200E - CHAPTER-5 CONFIGURATION 5.5.8 Inquire the RX Data Rate Inquire about the RX data rate of the specified E1 port via menu E1►RXDR, the parameter will be modified automatically according to the SLOT setting. The screen display is as follows: Related setting: See 5.5.4 “Set the Time Slots” 5.5.9 Inquire the Local Status Via menu E1►STATUS, inquire about the local status for the current E1 port. Press the key or the key to scroll screen and inquire more contents. The default setting displays “Not E1 Interface” when the E1 port is disabled. The screen display is as follows: 5.5.10 Inquire the Remote Status Via menu E1►RSTATUS, inquire about the status of the corresponding E1 port of the remote equipment. Press the key or the key to scroll screen and inquire more contents. The screen display is as follows: 5.5.11 Set the Port Loopback Via menu E1►LPBK, press the key or the key to select LLP, RLP or OFF and set the loopback function for the current E1 port. LLP - Loopback toward local side. - 53 -
  • 54. MUX-2200E - CHAPTER-5 CONFIGURATION RLP - Loopback toward remote side. The screen display is as follows: (here the default setting is set as OFF and the port loopback is OFF) 5.6 Utility 5.6.1 Set the Step Rate Set the step rate for MUX-2200E via menu UTILITY►DRSTEP. Press the key or the key to adjust the cursor position and press the key or the key to modify the value where the cursor is located. The step rate is n times 100bps, in which n ranges from 1 to 160. The screen is displayed in the table below. 5.6.2 Set the Clock Source Via menu UTILITY►REFS, press the key or the key to select and set the reference clock source of the TX clock of the system. See the table below for optional clock sources. Code Clock source TCXO Built-in temperature compensated crystal Oscillator CHN1-CHN4 TT clock of 4 serial ports, CHN1-CHN4 ST ST clock of trunk port - 54 -
  • 55. MUX-2200E - CHAPTER-5 CONFIGURATION RT RT clock of trunk port E1P1-E1P8 Restoring clock of E1P1-E1P8 Table 5-1 System clock source The screen display is as follows: 5.6.3 Reboot Via menu UTILITY►REBOOT, press the key or the key to select YES and press the ENTER key to reset the MUX-2200E immediately. The screen is displayed in the table below. The REBOOT function will result in interruption of the current data links. 5.6.4 Restore to Default Via menu UTILITY►DEFAULT, press the key or the key to select YES and press the ENTER key to clear all system configurations, which shall not affect the settings of the IP address. All user settings of the MUX-2200E will be erased and set to the default setting. The screen is displayed in the table below. The DEFAULT operation will not affect the IP address setting. The DEFAULT operation will result in interruption of the current links. 5.7 Status This section covers status and alarm information inquiry. Operations of the front panel concentrate on the STATUS function classification menu. - 55 -
  • 56. MUX-2200E - CHAPTER-5 CONFIGURATION 5.7.1 Display the Current Status Inquire about the current status via the STATUS►STAT menu. The screen is displayed in the table below. 5.7.2 Display the Active Alarms Inquire about all active alarm information via menu UTILITY►ALARM. Use the key and key to scroll screen and display alarm lists. - 56 -
  • 57. MUX-2200E - CHAPTER-6 MAINTENANCE CHAPTER-6 MAINTENANCE This Chapter mainly describes the field maintenance of the MUX-2200E, which consists of chassis clearance, function board replacement and software version update. It also gives additional descriptions of disassembly and assembly of main components according to field maintenance demand. 6.1 Disassemble the Major Components Before conduct any hardware replacement and software upgrade, user must be officially authorized by the manufacturer and follow the steps prescribed in this Chapter. Any hardware operation and software upgrade without official written authorization will void the product warranty immediately. 6.1.1 Precautions for Disassembly Read and follow all precautions mentioned on the section “Safety Instructions” in the manual. If additional descriptions provided with the equipment are not consistent with these descriptions, contact the technical service personnel of the supplier to acknowledge. To ensure heat radiation and ventilation, the chassis cover must be installed before the MUX-2200E is powered. The power supply switch cannot cut off the AC power supply completely. To cut it off completely, it is recommended to unplug the power cord connected to the MUX-2200E from the AC sockets. The following operations must be conducted on the ESD platform when it is necessary to open the chassis for component replacement or inspection. If such platform is not available, reduce the ESD hazards by the following means: Wear an anti-static bracelet and connect it to the metal part of the MUX-2200E. Touch the metal case of the MUX-2200E chassis before touching any parts of the MUX-2200E. Keep part of the body in touch with the metal chassis of the MUX-2200E to discharge electrostatic while handling components. Avoid unnecessary movements. Hold the components (especially the boards) by the edges when handling the MUX-2200E parts. Place the MUX-2200E components on a grounded, static-free operating platform. Use a conductive foam pad if available rather than use the component wrapper. - 57 -
  • 58. MUX-2200E - CHAPTER-6 MAINTENANCE Do not let components slide on the operating platform. 6.1.2 Tools for Disassembly Cross-head screwdriver; Anti-static bracelet and conductive foam pad (recommended); Paper and pens used to record the modification of the MUX-2200E system configuration status as well as specific information of all installed parts including the part number and the serial number; 6.1.3 Disassemble the Top Cover of the Chassis Ensure you have fully understood the contents contained in Precautions for Disassembly in this Chapter before operation and have read the safety warnings and precautions on the section “Safety Instructions” in the manual. 6.1.3.1 Remove the Top Cover of the Chassis Turn off the MUX-2200E and all the devices connected to it, Unplug the AC power cord. If the MUX-2200E is rack-mounted, the grounding wires and all related connection cables shall be removed, the equipment may be taken off of the rack and be placed on the disassembling platform; if the MUX-2200E is non-rack-mounted, other equipment stacked on it shall be taken down and related connection cables shall also be removed from the front and rear panels. Remove the 12 screws on the top cover of the chassis (refer to “①” shown in the figure below) and lift the top cover up (refer to “②” shown in the figure below). Figure 6-1. Disassembling diagram of the top cover of the chassis The installation procedure for the top cover of the chassis is opposite of the remove procedure of the top cover of the chassis. - 58 -
  • 59. MUX-2200E - CHAPTER-6 MAINTENANCE 6.1.4 Disassemble the Functional Modules Ensure you have fully understood the contents contained in Precautions for Disassembly in this Chapter and have read the safety warnings and precautions on the section “Safety Instructions” in the manual before operation. 6.1.4.1 Remove the Functional Modules Remove the top cover of the chassis (refer to the operation procedure of “Remove the top cover of the chassis”). Loosen the screws on the functional board (see “①” shown in the figure below, each sub-board is fastened with 2 screws). Press the system motherboard with one hand and hold the module edge with the other hand and lift it from the ramp top with even force and remove the board (see “②” shown in the figure below). Figure 6-2. Disassembling diagram for the functional modules 6.1.4.2 Install the Functional Modules Remove the top cover of the chassis. (Refer to the operation methods of “Remove the top cover of the chassis”) Align the interface on the functional module to the interface sockets on the motherboard and check whether the positions of four fastening screw holes on the board correspond to the supporting columns (see “①” shown in the figure below). Press the module down with even force from the interface positions at two sides of the module (see “②” shown in the figure below). Fasten the screws on the functional board. - 59 -
  • 60. MUX-2200E - CHAPTER-6 MAINTENANCE Figure 6-3. Installation diagram for the functional modules 6.1.5 Disassemble the Motherboard Ensure you have fully understood the contents contained in Precautions for Disassembly in this Chapter before operation and have read the safety warnings and precautions on the section “Safety Instructions” in the manual. 6.1.5.1 Remove the Motherboard Remove the top cover of the chassis (refer to the operation procedure of “Remove the top cover of the chassis”). Remove the functional modules (refer to the operation procedure of “Remove the functional modules”). Unplug the connection wires of other modules on the motherboard, include the exhausted fan, the power supply module, the keypad display module and the M&C interface module. Loosen 4 screws on the motherboard (see “①” shown in the figure below). Slip out the motherboard from the interface clearance of the rear panel of the chassis after inclining the board to one side (see “②” shown in the figure below). - 60 -
  • 61. MUX-2200E - CHAPTER-6 MAINTENANCE Figure 6-4. Disassembling diagram for the motherboard 6.1.5.2 Install the Motherboard Remove the top cover of the chassis. (Refer to the procedure for “Remove the top cover of the chassis”). Align the interface pins on the motherboard to the corresponding vacancy on the rear board (see “①” and “②” shown in the figure below), check whether the positions of the 4 fastening screw holes on the motherboard correspond to the supporting columns on the motherboard (see “③” shown in the figure below). Fasten 4 screws on the motherboard. Install the functional modules (Refer to the procedure for “Installing functional modules”) Connect the motherboard to the plugs of the connection wires of other modules in the chassis, includes the exhausted fan, the power supply module, the keypad display module and the M&C interface module). Figure 6-5. Installation diagram for the motherboard - 61 -
  • 62. MUX-2200E - CHAPTER-6 MAINTENANCE 6.2 Clean the Chassis Ensure you have fully understood the contents of this Chapter and have read the safety warnings and precautions on the section “Safety precautions” of the manual. Power supply button cannot cut off the AC power supply completely. To cut it off completely, the user must unplug all the power cords connected to the MUX-2200E from the AC sockets. Following the following steps to clear dust accumulated in the chassis over a long time. It is recommended to perform such cleaning once a year according to the conditions of the computer room. Remove the top cover of the chassis. (Refer to the procedure for “Remove the top cover of the chassis”). Clean the chassis with a dust catcher, especially the positions near to the left air inlet and the right exhaust fan. Clean the above positions with a brush if thick dust has accumulated. Repeat the above step. Check and ensure no foreign articles are left in the chassis, install the top cover of the chassis. (Refer to the procedure for “Install the top cover of the chassis”). Power on the equipment and check its status. 6.3 Replace the Functional Boards Ensure you have fully understood the contents of this Chapter and have read the safety warnings and precautions on the section “Safety precautions” of the manual. Power supply button cannot cut off the AC power supply completely. To cut it off completely, the user must unplug all the power cords connected to the MUX-2200E from the AC sockets. Replacement of the functional board (motherboard) may result in missing original parameter configuration. Record such configuration in advance before replacement. Replacement of any functional board must follow the following steps based on the demand for system hardware configuration adjustment and for rapid field maintenance of faulty boards. Record the current parameter configurations. - 62 -
  • 63. MUX-2200E - CHAPTER-6 MAINTENANCE Remove the top cover of the chassis. (Refer to the procedure for “Remove the top cover of the chassis”). Use a dust catcher to dedust the inside of the chassis. Remove the original functional board (motherboard). (Refer to the procedure for “Remove the functional board (motherboard)”). Record the type and serial number information of the current boards as well as the type and serial number information of new boards. Install the new functional board (motherboard). (Refer to the procedure for “Install the functional board (motherboard”). Check and ensure no foreign articles are left in the chassis, install the top cover of the chassis. (Refer to the procedure for “Install the top cover of the chassis”). Power on the equipment and check its status. Check parameter configurations. Fill out the following form after the replacement of functional boards is completed, and inform the Customer Service Center of Wancom via fax or e-mail. Customer name: Telephone: Engineer name: E-mail: Replacement Time: Unit Part Number: Serial Number: Motherboard Serial number: Module: CPU Module: Serial number: Voice Module: Serial number: E1 Module: Serial number: New Board: Serial number: Table 6-1. Field Maintenance Record Sheet 6.4 Upgrade the Firmware The MUX-2200E supports field software upgrading to realize notable improvement of equipment performance. Users may consult the manufacturer to acquire new product software upgrading data package. Theoretically, system software version upgrading will not result in missing original parameter configurations. For the sake of safety, it is recommended to record the original configurations before upgrading. Use cables to connect the computer and J10 or J12 on the rear panel of the MUX-2200E to be upgraded; or connect the computer for upgrading and the MUX-2200E to the same network exchange or HUB via LAN cables. - 63 -
  • 64. MUX-2200E - CHAPTER-6 MAINTENANCE Set the computer and the MUX-2200E to be upgraded at the same IP network segment. Find the folder contained the MUX-2200E upgrading file on the computer and double-click the icon to run the upgrading program. Figure 6-6. Software upgrade program interface Click the SCAN button in the Upgrade Program window; the program will search all linkable MUX-2200E. Figure 6-7. The upgrade program screen – unit scan process Select the corresponding IP address of the MUX-2200E which needs to upgrade firmware in the “Machines List” list in the upper left corner of the window and view the current version information in the “Version Information:” in the upper right corner of the window and confirm the version that needs to be upgraded. Check the checkbox before “Reboot after Upgrade” in the middle of the window. Click the Upgrade button to start the uploading process of the firmware upgrade - 64 -
  • 65. MUX-2200E - CHAPTER-6 MAINTENANCE package. The user may enter the IP address of the MUX-2200E to be upgraded in the address column at the left of the Upgrade button in the middle of the window, and click the Upgrade button to start the uploading of the upgrade software package. Figure 6-8. The upgrade program screen - uploading process The program prompts “info: upgrade finished”, the MUX-2200E will reboot automatically. Use the Hyperterminal or Telnet to connect equipment and check the new version information displayed on the screen, or use the upgrade program to execute the SCAN operation again and select the MUX-2200E after upgraded and view the new version information in the Version Information box. Check whether equipment configurations are complete and accurate. - 65 -
  • 66. MUX-2200E - CHAPTER-6 MAINTENANCE This page is intentionally left blank. - 66 -
  • 67. MUX-2200E - ANNEX-1 CLI COMMAND ANNEX-1 CLI COMMAND A1.1 Basic Command Formats The CLI command formats for the MUX-2200E are classified as three kinds. Port (interface)-related configuration operations Input command: <Address/command_port_[value] Device feedback: >Address/command_port_value Other configuration operations Input command: <Address/command_[value] Device feedback: >Address/command_value Inquiry operations Input command: <Address/command_ Device feedback: > A1.1.1 Start Character Computer to Device: ’<’ (ASCII code 60) Device to Computer: ’>’ (ASCII code 62) A1.1.2 Unit Address Address range used for serial M&C is 0~255 and the default address is 1. It is set via UNIT►ADDR on the front panel. A1.1.3 Address Separator ‘/’ (ASCII code 47) is used as the separator between address and command in the CLI command format. A1.1.4 Command Code Command code consists of a character string of variable lengths in the CLI command - 67 -
  • 68. MUX-2200E - ANNEX-1 CLI COMMAND format without the upper and lower case difference. A1.1.5 Instruction Code Qualifiers In CLI command format, both ’_’ (i.e. the underline, which ASCII code is 95) and ’ ’ (i.e. the space character, which ASCII code is 32) may be qualifiers for mixed use. E.g., enter the following two commands via the keypad, their roles are exactly the same. <addr/TXDR_n_[xxx] <addr/TXDR n [xxx] A1.1.6 Port Number In CLI command format, the port number ranges from 0 to 9. The correspondence between the port number in the command format and the hardware port is shown in the table below under normal conditions: Port # hardware port Remarks 0 CH5/CH6 Serial trunk port 1-4 CH1-CH4 Serial port 5-8 J5-J8 E1 port 9 J1-J4 Voice port Table 7-1. Port number correspondence table A1.1.7 Optional Parameter Values In CLI command format, parameter values correspond to those of specific ports or the value of specific parameters. If input commands do not contain parameter values, the equipment will return to the current configuration or status. A1.2 CLI Command Set A1.2.1 Port Commands Enable/Disable the voice port Command: <addr/VEN_n_[xxx] Answer: >addr/VEN_n_xxx n: voice port number, n=1-4 xxx: ON/OFF, xxx=ON/OFF - 68 -