(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
133874 RANEE AGENCIES-Model.pdf
1. 10.50M 5.70M 18.50M
2.10M 2.10M
13.50M
6.10M
6.27M
8.0M
8.0M
6.8M
6.8M
17.20M
6.8M
3.0M
7.60M
39.60M
24.14M
22.62M
S
F
S S
D
V
M
TANK-
1
HSD
(15
KLD)
HSD
S
F
S
S
D
V
M
TANK- 2 MS (20 KLD)
HSD
10.00M
12.0M
7.2M
3.10M
1.5M
MS/HSD
MS/HSD
2.1M
0.9M
0.9M
0.9M
3.98M
5.9M
2.3M
2.3M
1.5M
1.5M
2.3M
1.5M
CURVE WALL CURVE WALL
CURVE
WALL
CURVE
WALL
CURVE
WALL
CURVE
WALL
R
=
3
.
6
M
2.30M
2.5M
R=4.0M
HIGH MAST LIGHT
G.TOILET
2.0X2.5M
L.TOILET
1.8X2.5M
OIL ROOM
3.5X2.5M
ELEC. ROOM
3.5X2.5M
OFFICE&
AUTOMATION
ROOM
3.5X2.5M
SALES ROOM
7.70X4.09M
D
D
D
D D
D
COMPOUND WALL 1.20M HT
ALROUND
1X15KL HSD TANK 1.95M DIA X 5.50M LONG
IN UNDER DRIVE WAY EITH STRIP RAFT AND
TOP COVERED BY RCC SLAB.
1X20 KL MS TANK 2.10M DIA X 6.25M LONG
IN UNDER DRIVE WAY WITH STRIPRAFT
AND TOP COVERED BY RCC SLAB
2 NOS PUMP ISLAND 2.10M X 0.90M E/O MPD,HSD,MS
DISPENSING PUMP CONFG. TO IS 2148 4 NOS SAND
BUCKETS & FIRE EXTINGUISHERS
ISLAND DONT HAVE MPD
VENT PIPE 1.50M HT.
ABOVE ROOF LEVEL.
BUFFER STRIP
6.0MX1.62M
CANOPY
WATER PUMP
AIR
MITTER
MAIN SIGN BOARD
INGRESS EGRESS
Fall
Fall
Fall
DG
SET
30
KVA
DG SET
YARD LIGHT
7.0
2M
PWD BOUNDARY
1.4
M
7.8
M
1.2
M
9.0
M
1.2
M
9.0
M
39.60M
11
12 10 9 8 7 6 5 4 3 2 1
B
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
11
12 10 9 8 7 6 5 4 3 2 1
REFERENCE DRAWINGS
S.NO. DRAWING TITLE DRAWING NUMBER
NEW NOTES FOR CBG:-
A1
SIZE
SCALE:
JOB NO.
TOTAL NO. OF SHTS: SHT.NO
DRAWING NUMBER REV.
1.
DATE
11.08.2022 01
TITLE:
CLIENT:
REV. DATE DESCRIPTION PREP. CHKD. APPD.
CAPACITY PRODUCT PUMP TANK SIZE
PLATE THICKNESS
END SHELL
1X20 KL 2.10MX6.00M 8MM 6MM
MS
TANK DETAILS
CERTIFIED THAT
1. CNG DISPENSER IS CONNECTED TO STORAGE
CASCADE VIA BOOSTER COMPRESSOR BY SS TUBES.
2. THE PROPOSED CNG FACILITIES ARE DESIGNED
IN ACCORDANCE WITH THE FOLLOWING CODE AND
GUIDELINES:
A. NZS 5425 - 1980.
B. PETROLEUM RULES - 2002.
C. GAS CYLINDER RULES - 2004. (GOVT. OF INDIA.)
D. GUIDE LINES OF CHIEF CONTROLLER OF
EXPLOSIVES NAGPUR.
3. FIRE SAFETY EQUIPMENT FOR CNG FACILITIES
SHALL BE PROVIDED AND INSTALLED BY CLIENT.
4. FIRE SAFETY AND TRAFFIC SIGNS SHALL BE INSTALLED BY R.O.
5. ALL EXISTING LIGHTING POLES SHOULD BE INSTALLED 6 METER AWAY FROM
THE CNG EQUIPMENTS LIKE COMPRESSORS, CASCADES & DISPENSORS.
A. NECESSARY APPROVALS/CLEARANCES FROM MOP,
,IRC AND ALL OTHER CONCERNED , DEPARTMENT HAVE
ALREADY OBTAINED.
B. NO CASE IS PENDING IN ANY COURT OF LAW AGAINST
THIS PREMISES/DEALERSHIP
C. THIS IS NOT A RE-SITEMENT CASE
E. ALL FACILITIES WILL BE INSTALLED EXACTLY AS PER THIS PLAN
F. ERECTION OF CANOPY IS AS PER IS STANDARED DRAWINGS
APPROVED BY CCOE/NAGPUR. VIDE REF.NO.P6(5)83 DATED 09/05/2003
NOTE :
1. PROPOSAL SHOWN IN RED.
2. DISMANTLED SHOWN IN YELLOW
3. APPROVED BUT NOT CONSTRUCTED SHOWN IN GREEN
4. PRO. TANK IS CONFG TO IS 10987.
5. END PLATE 8MM TH, SHELL PLATE 6MM TH.
6. FILL POINT 3.60M RADIUS
7 .23M THICHK BRICK MASONRY COMPOUND WALL 1.20M HT.
ALL ROUND THE INSTALLATION AREA
8. NO ELECTRICAL WIRE PASSING OVER THE SITE
VENT PIPE 40MMØ 4.0M HT AND 4.0M CLEARANCE COVERED WITH
TWO LAYERS OF NON-CORRODING METAL WIRE MESH 11 PER LINEAR CM.
9. 12NOS. FIRE EXTINGUISHERS D.C.P. TYPE, 10KGS.CAP.AND 12NOS.
10. SAND BUCKETS PROVIDED.
11. HSD/MS DISPENSING PUMP CONFG. TO IS 2148.
FILL PIPE AND DIP PIPE OF UNDER GROUND TANKS
12. ARE PROVIDED WITH AIR TIGHT THREADED BRASS CAP.
13. NO SMOCKING BOARD DISPLAYED AT SITE
1. ALL DIMENSIONS ARE IN MM.
2. CNG DISPENSER IS CONNECGTED TO STORAGE CASCADE VIA CNG COMPRESSOR
3. THE PROPOSED CNG FACILITIES ARE DESIGNED IN ACCORDANCE WITH THE
FOLLOWING CODE AND GUIDLINES.
A. NZS 5452-1980/OISD-179.
B. PETROLEUM RULES-2002.
C. GAS CYLINDER RULES -2004/2016.
(GOVT. OF INDIA).
D. GUIDE LINES OF CHIF CONTROLLER OF EXPLOSIVES.
4. FIRE SAFETY EQUIPMENT FOR CNG FACILITIES SHALL BE PROVED
5. FIRE SAFETY AND TRAFFIC SIGNS SHALL BE INSTALLED.
6. ALL EXISTING LIGHTING POLES SHOUD BE INSTALLED 6 METER AWAY FROM THE
CNG EQUIPMENTS LIKE COMPRESSORS. CASCADE & DISPENSERS.
20 KL
2.10 m dia
LONGITUDINAL SECTION OF 15KL U/D
CROSS SECTION OF 15KL U/D
2100
700
350
350
600 600
IndianOil
INDIANOIL CORPORATION LTD
MARKETING DIVISION
TRICHY DIVISIONAL OFFICE
B34,3RD FLOOR ,THIRIVENI BUILDING
SASTRI ROAD THILAI NAGAR
TRICHY-18.
CONSULTANT:
MS REFLECTIVE TECHNO STYLE.
Mob No -9937460565,8093540205
Email ID : bibhu_bandematarm@yahoo.com,reflective_style@yahoo.com.
1181 - NEAR SANTOSHI MAA TEMPLE,BOMIKHAL,BHUBANESWAR.
1X15 KL 8MM
AREA OF THE PLOT
AREA OF THE OFICE BUILDING - 87.64SQ.M
AREA OF THE CANOPY - 339.13SQ.M
- 925.83SQ.M
S.NO. ROOM SIZE
1
2
3
4
5
6
SALES ROOM
OFFICE ROOM
OIL ROOM
GENTS TOILET
LEDIES TOILET
ELEC. ROOM
7.70X4.09M
3.5X2.5M
3.5X2.5M
2.0X2.5M
1.8X2.5M
3.5X2.5M
7
CNG PIPE LINE. ARROW IN DIRECTION OF FLOW.
SAND BUCKET
S
N "NO SMOKING" SIGN
"STOP VEHICLE" SIGN
"NO OPEN FLAME PERMITTED" SIGN
"FLAMMABLE GAS" SIGN
SIGN SHOWING DETAILED PRECAUTIONS
& PROCEDURE OF REFUELLING.
V
F
G
P
DCP(10) DCP ( 10 kg )
DCP(75) DCP ( 75 kg )
E EARTH PIT
EE INSTRUMENT EARTH PIT
1 NO.
3 NOS.
3 NOS.
5 NOS.
1 NO.
4 NOS.
3 NOS.
3 NOS.
3 NOS.
1 NO.
LEGENDS:-
SITE PLAN & KEY PLAN
M/S. RANI AGENCIES
REFERENCE
N
W
S
E
5MM
1.95MX5.50M
S.NO.
VILLAGE
TALUK
DISTRICT
NEAREST RAILWAY STATION
NEAREST FIRE STATION
NEAREST POLICE STATION
144/1A
NO.199, PULIANTHOPPU
THANJAVUR
THANJAVUR
TAMIL NADU
600012
THANJAVUR
STATE
PIN
PLAN SHOWING THE RETAIL OUTLET
MS/HSD FILLING STATION PULIANTHOPPU
G.L. G.L.
Plinth beam
9"x12"
0.25
P.C.C. 1:5:10
COLUMN ROD
BOTH WAYS
4 Nos 12 Ø
0.25
0.15 1.20
GL
COLUMN MATT
SAND FILLING
1.0M
COMPOUND WALL
1.20MHT. ALROUND
GL
P.C.C (1:3:6)
R.R IN CM 1:6
.23M
0.15
1.37
1.5M
1.50M
WBM IN TWO LAYER 75mm TH.
BITUMINOUS MACADAM
PREMIX CARPET 20mm TH.
75 mm TH.
900MMØ R.C. HUME PIPE
WELL GRADED GRAVEL
( NP4 CLASS )
FILLING
GL
.10
.10
R.C.C1:2:4 0.23TH.
GL
SAND FILLING 0.3TH.
C.C1:4:8 0.23TH.
.10
.90M
.75M
39.60M
24.14M
22.62M
1.4
M
39.60M
7.8
M
1.2
M
1
0
0
M
1
0
0
M
1
0
0
M
1
0
0
M
5.70M
2.10M 2.10M
6.10M
MS/HSD
MS/HSD
2.1M
0.9M
0.9M
0.9M
16183.36M
17776.55M
6.0M
1.6
2M
7.4M
REFERENCE
N
W
S
E
12.0M
G.TOILET
2.0X2.5M
L.TOILET
1.8X2.5M
OIL ROOM
3.5X2.5M
ELEC. ROOM
3.5X2.5M
OFFICE&
AUTOMATION
ROOM
3.5X2.5M
SALES ROOM
7.70X4.09M
D
D
D
D D
D
IOC
RETAIL
OUTLET
AGRICULTURAL LAND
AGRICULTURAL LAND
AGRICULTURAL LAND
SERVICE ROAD
FLY OVER
FLY OVER
TO TANJAVUR
TO NAGAPATINAM
9.0
M
1.2
M
9.0
M
HSD
20 KL
2.10 m dia
LONGITUDINAL SECTION OF 20KL U/D
CROSS SECTION OF 20KL U/D
2100
700
350
2100
700
350
340
600
UNDER DRIVE WAY TANK (20KL)
UNDER DRIVE WAY TANK (15KL)
MS/HSD
BUILDING PLAN
6.0M
AS PER SITE
CONDITION
CANOPY SECTION CANOPY SECTION
SECTION
COMPOUND WALL DETAILS
FOUNDATION WALL DETAILS
SERVICE ROAD
FLY OVER
FLY OVER
133874
LIC. NO.P/SC/TN/14/2310(P36387)
7.2M
THANJAVUR
THANJAVUR
SCALE 1:200