International Journal of Electrical and Computer Engineering (IJECE)
Vol. 11, No. 2, April 2021, pp. 1029~1035
ISSN: 2088-8708, DOI: 10.11591/ijece.v11i2.pp1029-1035  1029
Journal homepage: http://ijece.iaescore.com
Power dissipation analysis of PV module under partial shading
Byunggyu Yu1
, Seok-Cheol Ko2
1
Division of Electrical, Electronic and Control Engineering and Regional-Industrial Application Research Institute and
Institute of IT Convergence Technology, Kongju National University, Republic of Korea
2
Industry-University Cooperation Foundation and Regional-Industrial Application Research Institute,
Kongju National University, Republic of Korea
Article Info ABSTRACT
Article history:
Received Aug 19, 2020
Revised Sep 4, 2020
Accepted Oct 7, 2020
Photovoltaic (PV) generation has been growing dramatically over the last
years and it ranges from small, rooftop-mounted or building integrated
systems, to large utility scale power stations. Especially for rooftop-mounted
PV system, PV modules are serially connected to match with PV inverter
input voltage specification. For serially connected PV system, shading is a
problem since the shaded PV module reduces the output whole string of PV
modules. The excess power from the unshaded PV module is dissipated in
the shaded PV module. In this paper, power dissipation of PV module under
partial shading is analyzed with circuit analysis for series connected PV
modules. The specific current and voltage operating point of the shaded PV
module are analyzed under shading. PSIM simulation tool is used to verify
the power dissipation analysis. When there is no bypass diode and three solar
modules are connected in series, upto 39.1% of the total maximum PV power
is dissipated in the shaded PV module. On the other hand, when the bypass is
attached, 0.3% of the total maximum power is generated as a loss in the
shaded PV module. The proposed analysis technique of shaded PV module
could be used in PV system performance analysis, especially for maximum
power point tracking (MPPT) performance.
Keywords:
Hotspot
Partial shading
Power dissipation
PV generation
PV module configuration
PV modules
This is an open access article under the CC BY-SA license.
Corresponding Author:
Byunggyu Yu
Division of Electrical, Electronic and Control Engineering and Institute of IT Convergence Technology
Kongju National University, 1223-24 Cheonan Daero
Seobuk-gu, Cheonan-Si, Chungnam, 330-717, Republic of Korea
Email: bgyuyu@kongju.ac.kr
1. INTRODUCTION
Photovoltaic (PV) generation is to convert sunglight directly into electricity by using PV module,
which is called as the photovoltaic effect. As PV is one of the increasing important renewalbe energy
resources, and it has been widely spread around the world [1, 2]. Recently, PV generation has become cost
competitive in many regions and it consits of three market segments: residential rooftop [3-5], commercial
rooftop [6-7], and ground mount utility scale systems [8-10]. Especially, the number of residential PV system
has grown rapidly over the past years [11, 12] and sized to provide power that would offset as much of the
household load as possible. An averaging around 5kW was specified based on the predicted load for a peak
day [13]. PV modules are serially connected for residential application by matchng with PV string inverter
input voltage specification [14-16]. For serially connected PV system, shading, such a s birds, tree shadows,
is a problem since the shaded PV module reduces the output whole string of PV modules [17-19]. The excess
power from the unshaded PV module is dissipated in the shaded PV module and it is shown that temperature
of the shaded PV module or cell rises as hot spot [20-22]. Until now, research on the shaded PV modules or
 ISSN: 2088-8708
Int J Elec & Comp Eng, Vol. 11, No. 2, April 2021 : 1029 - 1035
1030
cells has been mainly on the performance of the whole PV system, and there has been little analysis on the
circuit and power dissipation of each PV module [23-25].
In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis
for series connected PV modules. Firstly, analysis of PV module power dissipation is presented accroding to
the amount of the electric load and circuit operation of each PV module is also introduced. Then, in order to
verify the analysis technique, the simulation results are presented.
2. ANALYSIS OF PV MODULE POWER DISSPATION
Figure 1 shows the voltage-current characteric curve of PV module by the operating point, which
can be classified into three regions. Region 1 is in the power generation mode, which is a desirable condtion
to achieve the electric power from the sunlight. However, PV modules are conducted as a power load in Region 2
and 3. The power dissipation in Region 2 and 3 happen under abnormal environmental conditions like partial
shading. More specifically, reverse voltage of Region 2 appears in the series-connected PV cells or modules,
reverse current of Region 3 appears in the parallel-connected PV cells or modules under partial shading.
Figure 1. Voltage-current characteristic curve of PV module by the operation point
In this paper, the scope of power dissipation analysis is limited to a series-connected PV modules to
focus on bypass diode performance of PV module. In other words, Region 2 of PV module characteristic
curve is analyzed under shading condition. In order to analyze the performance of PV module power
generation under shading, the following condition is assumed as follows:
Figure 2 shows the PV modules configuration in series to analyze the effect of shading and
performance of bypass diodes. Without any shading, n PV modules in series shows voltage-current curve in
Figure 3. In the case of n PV modules without bypass didoe under partial shading, the available power to be
generated is reduced becasue there is no path for the other current from no shaded (n-1) PV modules. This
current makes the reverse voltage of the shaded PV module. Thus, the power is dissipated in the area of Figure 4.
The amount of power dissipation can be quantitized as (1).
𝑃𝑑𝑖𝑠𝑠 = 𝑉𝑝𝑣,𝑛𝑡ℎ × 𝐼𝑠ℎ𝑎𝑑𝑖𝑛𝑔 (1)
while shading on nth PV module, the nth PV voltage ranges from -Vop to zero for power dissipation and the
nth PV current ranges from Ishadning,nth to Isc,nth. The amount of power dissipation is dominated from the other
(n-1) PV modules’ voltage. Specifically, the power dissipation is maximized at the short circuit condition, R2,min.
In the same way, when n PV modules with bypass diode under partial shading, the generated power
can be maximized compared with the previous case, because the bypass diode provides the path for the other
current from no shaded (n-1) PV modules. The reverse voltage of the shaed PV module is dominated by the
bypass diode threshold voltage, which is normaly 0.7V. Thus, as shown in Figure 5, the power dissipation is
Int J Elec & Comp Eng ISSN: 2088-8708 
Power dissipation analysis of PV module under partial shading (Byunggyu Yu)
1031
reduced dramatically by the low reverse voltage 0.7 V of the shaded nth PV module, compared with the case
of no bypass diode. In short, the amount of power dissipation can be quantitized as (2).
𝑃𝑑𝑖𝑠𝑠 = 0.7 × 𝐼𝑠ℎ𝑎𝑑𝑖𝑛𝑔 (2)
(a) (b) (c)
Figure 2. PV modules configuration in series, (a) case 1: PV connection under no shading,
(b) case 2: PV connection without bypass didoes under partial shading,
(c) case 3: PV connection with bypass diodes under partial shading
Figure 3. Voltage-current characteristic curve of n PV modules in series under no shading
(a) (b)
Figure 4. Voltage-current characteristic curve of n PV modules in series without by pass diodes under partial
shading, (a) overall curve of n PV modules, (b) Separate curves of both a PV module under shading and the
others under no shading
 ISSN: 2088-8708
Int J Elec & Comp Eng, Vol. 11, No. 2, April 2021 : 1029 - 1035
1032
(a) (b)
Figure 5. Voltage-current characteristic curve of n PV modules in series with bypass diodes under partial
shading, (a) overall curve of n PV modules, (b) separate curves of both a PV module under shading
and the others under no shading
3. SIMULATION RESULTS
In order to verify the analysis of power dissipation, three PV modules in series are tested in PSIM
simulation software. A commercial PV module datasheet is used for the specification of a PV module to
simulate three PV modules in series under partial shading, where maximum power Pmax is 360W, voltage at
maximum power Vmp is 38 V, current at maximum power is 9.47 A, open circuit voltage Voc is is 47 V, and
short circuit current Isc is 9.72 A.
Three different scenarios as shown in Figure 2 are considered for three PV modules (n=3) in series,
in order to verify the analysis of power dissipation. Figure 6 shows characteristic curves of three PV modules
in series with regards to shading and bypass diode. For Case 1, there is no distortion of the characteristic
curves on PV current and PV power with the nominal values under no shading, and there is only one global
maximum power point (MPP). Compared with Case 1, the results of Case 2 and Case 3 under shading are
shown in Figure 6. Without bypass diode, the short circuit current for Case 2 is reduced from 9.72 A to
4.861A becasue there is no path for the other current from no shaded two PV modules. Accordingly, the
maximum power with only one global MPP is decrease from 1080W to 607 W. The power degradation cause
the PV module problem as hot spot problem. Hot spot heating occurs in a PV module under Case 2 while its
operating current exceeds the reduced short circuit current.
(a) (b)
Figure 6. Characteristic curves of three PV modules in series with regards to shading and bypass diode,
(a) voltage-current curve, (b) voltage-power curve
For Case 3, there are two local MPP which are 713 W and 607 W because the bypass diode provides
the path for the other current from no shaded two PV modules. Since the short circuit current isn’t reduced
with bypass diode, the hotspot problem of Case 2 doesn’t occurs. Specific analysis of power dissipation for
the shaded PV module and the other has been conducted. Figure 7 shows the voltage-current characteristic
curve of three PV modules in series under partial shading. For Case 2, the voltage across the shaded 3rd PV
module ranges from a negative value, -86.968V to a positive value, 46.263 V, as shown in Figure 7(a). While
Int J Elec & Comp Eng ISSN: 2088-8708 
Power dissipation analysis of PV module under partial shading (Byunggyu Yu)
1033
PV voltage is operated at a negative value, the shaded PV module dissipates its power upto 422.751 W as
shown in Figure 8, which can be analyzed by (1). In other words, when there is no bypass diode and three
solar modules are connected in series, upto 39% of the total power generated by the shaded PV module is
dissipated, which cause a hotspot.
For Case 3, the negative voltage across the shaded 3rd PV module is limited to 0.7 V as shown in
Figure 7(b), which is the threshold voltage of the bypass diode. The power dissipation of the shaded PV
module is limited 3.402W as shown in Figure 8. Which means that just 0.3% power loss of the total power
available occurs when the bypass diodes are attached to the PV modules. Therefore, it is concluded that
power dissipation can be dramatically reduced by the bypass diode. This result can be applied into a PV
module, which is consisted with PV cells and bypass diodes.
(a) (b)
Figure 7. Voltage-current characteristic curve of three PV modules in series under partial shading,
(a) without bypass diode in case 2, (b) with bypass didoe in case 3
Figure 8. Power loss comparison of shaded PV modules under partial shading with respect to bypass diode
4. CONCLUSION
This paper presents the study on the power dissipation of PV module under partial shading with
circuit analysis for series connected PV modules. For verify the analysis method, three commercial PV
modules in series are considered by PSIM simulation under partial shading. When there is no bypass diode
and three solar modules are connected in series, upto 39% of the total maximum PV power is dissipated in
the shaded PV module. On the other hand, when the bypass was attached, 0.3% of the total maximum power
was generated as a loss in the shaded PV module. As a result, the circuit operation of the shaded PV modules
was verified as the analysis method to casue so called hot spot. The proposed analysis method on power
dissipation of the shaded PV module can be used in the application of PV system performance improvement
to prevent hotspot and acheive higher power generation from the shaded PV string.
 ISSN: 2088-8708
Int J Elec & Comp Eng, Vol. 11, No. 2, April 2021 : 1029 - 1035
1034
ACKNOWLEDGEMENTS
This work was supported by the 2020 sabbatical year research grant of Kongju National University.
REFERENCES
[1] S. Eftekharnejad, G. Heydt, and V. Vittal, "Optimal Generation Dispatch With High Penetration of Photovoltaic
Generation," IEEE Transactions on Sustainable Energy, vol. 6, no. 3, pp. 1013-1020, 2015.
[2] P. Vithayasrichareon, G. Mills, and I. Macgill, "Impact of Electric Vehicles and Solar PV on Future Generation
Portfolio Investment," IEEE Transactions on Sustainable Energy, vol. 6, no. 3, pp. 899-908, 2015.
[3] R. Li and F. Shi, "Control and Optimization of Residential Photovoltaic Power Generation System with High
Efficiency Isolated Bidirectional DC-DC Converter," IEEE Access, vol. 7, pp. 116107-116122, 2019.
[4] Y. Sun, et al., "Artificial Neural Network for Control and Grid Integration of Residential Solar Photovoltaic
Systems," IEEE Transactions on Sustainable Energy, vol. 8, no. 4, pp. 1484-1495, 2017.
[5] M. Khan, et al., "Autoinspection and Permitting With a PV Utility Interface (PUI) for Residential Plug-and-Play
Solar Photovoltaic Unit," IEEE Transactions on Industry Applications, vol. 53, no. 2, pp. 1337-1346, 2017.
[6] S. Martin, et al., "Model to evaluate the system-wide impact of residential and commercial photovoltaic and storage
units intended for self-consumption," IET Renewable Power Generation, vol. 13, no. 12, pp. 2111-2122, 2019.
[7] N. Kandsamy, K. Kandasamy, and K. Tseng, "Loss-of-life investigation of EV batteries used as smart energy
storage for commercial building-based solar photovoltaic systems," IET Electrical Systems in Transportation,
vol. 7, no. 3, pp. 223-229, 2017.
[8] X. Li, et al., "An Unmanned Inspection System for Multiple Defects Detection in Photovoltaic Plants," IEEE
Journal of Photovoltaics, vol. 10, no. 2, pp. 568-576, 2020.
[9] A. Sizkouhi, et al., "Automatic Boundary Extraction of Large-Scale Photovoltaic Plants Using a Fully
Convolutional Network on Aerial Imagery," IEEE Journal of Photovoltaics, vol. 10, no. 4, pp. 1061-1067, 2020.
[10] T. Kohno, et al., "Fault-Diagnosis Architecture for Large-Scale Photovoltaic Power Plants That Does Not Require
Additional Sensors," IEEE Journal of Photovoltaics, vol. 9, no. 3, pp. 780-789, 2019.
[11] D. W. H. Cai, et al., "Impact of residential PV adoption on Retail Electricity Rates," Energy Policy, vol. 62,
pp. 830-843, 2013.
[12] Y. Li, W. Gao, and Y. Ruan, "Performance investigation of grid-connected residential PV-battery system focusing
on enhancing self-consumption and peak shaving in Kyushu, Japan," Renewable Energy, vol. 127, pp. 514-523, 2018.
[13] D. Chung, et al., “U.S. Photovoltaic prices and cost breakdowns: Q1 2015 benchmarks for residential, commercial,
and utility-scale systems,” NREL Technical Report, pp. 1-51, 2015.
[14] M. Boztepe, et al, "Global MPPT Scheme for Photovoltaic String Inverters Based on Restricted Voltage Window
Search Algorithm," IEEE Transactions on Industrial Electronics, vol. 61, no. 7, pp. 3302-3312, Jul. 2014.
[15] C. Yu, et al., "Modeling and Analysis of Common-Mode Resonance in Multi-Parallel PV String Inverters," IEEE
Transactions on Energy Conversion, vol. 34, no. 1, pp. 446-454, 2019.
[16] A. Rana, M. Nasir, and H. Khan, "String level optimisation on grid-tied solar PV systems to reduce partial shading
loss," IET Renewable Power Generation, vol. 12, no. 2, pp. 143-148, 2018.
[17] M. Mohamed, A. Diab, and H. Rezk, "Partial shading mitigation of PV systems via different meta-heuristic
techniques," Renewable Energy, vol. 130, pp. 1159-1175, 2019.
[18] H. Sah, S. Nayyak, and S. Mishra, "Maximizing the Power Generation of a Partially Shaded PV Array," IEEE
Journal of Eemerging and Selected Topic in Power Electronics, vol. 4, no. 2, pp. 626-637, 2016.
[19] O. Bingol and B. Ozkaya, "Analysis and comparison of different PV array configurations under partial shading
conditions," Solar Energy, vol. 160, pp. 336-343, Jan. 2018.
[20] K. Kim and P. Krein, "Reexamination of Photovoltaic Hot Spotting to Show Inadequacy of the Bypass Diode,"
IEEE Journal of Photovoltaics, vol. 5, no. 5, pp. 1435-1441, 2015.
[21] M. Dhuimish, "70% Decrease of Hot-Spotted Photovoltaic Modules Output Power Loss Using Novel MPPT
Algorithm," IEEE Transactions on Circuits and Systems II: Express Briefs, vol. 66, no. 12, pp. 2027-2031, 2019.
[22] D. Winston, "Efficient Output Power Enhancement and Protection Technique for Hot Spotted Solar Photovoltaic
Modules," IEEE Transactions on Device and Materials Reliability, vol. 19, no. 4, pp. 664-670, 2019.
[23] J. Ma, et al., "Detection and Assessment of Partial Shading Scenarios on Photovoltaic Strings," IEEE Transactions
on Industry Applications, vol. 54, no. 6, pp. 6279-6289, 2018.
[24] S. Mishra, H. Ziar, O. Isabella, and M. Zeman, "Selection Map for PV Module Installation Based on Shading
Tolerability and Temperature Coefficient," IEEE Journal of Photovoltaics, vol. 9, no. 3, pp. 872-880, 2019.
[25] J. Ahmed and Z. Salam, "An Improved Method to Predict the Position of Maximum Power Point During Partial
Shading for PV Arrays," IEEE Transactions on Industrial Informatics, vol. 11, no. 6, pp. 1378-1387, 2015.
Int J Elec & Comp Eng ISSN: 2088-8708 
Power dissipation analysis of PV module under partial shading (Byunggyu Yu)
1035
BIOGRAPHIES OF AUTHORS
Byunggyu Yu was born in Korea, in 1976. He received the BS and MS degrees in electrical
engineering from Pusan University, Korea, in 2000 and from KAIST in 2002, respectively. Since
2002, he had been with the Korea Institute of Energy Research as a Research Fellow. In 2007, he
started his RONPAKU doctoral degree program supported by a scholarship from the government
of Japan at the Tokyo Polytechnic University, and he received the PhD degree in electrical
engineering in 2010. Since 2012, he has been with Kongju National University as an assistant
professor. His research interests include photovoltaic system including the module-integrated
converter system and its control algorithm.
Seok-Cheol Ko received his B. S., M. S., and Ph.D. degrees from Chonbuk National Univ.,
Korea in 1996, 2002, and 2005, respectively. Currently, he is a professor in the Industry-
University Cooperation Foundation at Kongju National Univ., Korea.

Contenu connexe

Tendances

A study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellsA study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellseSAT Journals
 
IJSRED-V2I3P24
IJSRED-V2I3P24IJSRED-V2I3P24
IJSRED-V2I3P24IJSRED
 
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...IRJET Journal
 
Iaetsd design, engineerning and analysis
Iaetsd design, engineerning and analysisIaetsd design, engineerning and analysis
Iaetsd design, engineerning and analysisIaetsd Iaetsd
 
Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...
Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...
Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...IDES Editor
 
Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...
Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...
Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...journalBEEI
 
Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...
Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...
Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...INFOGAIN PUBLICATION
 
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...IRJET Journal
 
A High Static Gain Modified SEPIC Converter With PV Module and MPPT
A High Static Gain Modified SEPIC Converter With PV Module and MPPTA High Static Gain Modified SEPIC Converter With PV Module and MPPT
A High Static Gain Modified SEPIC Converter With PV Module and MPPTIRJET Journal
 
IRJET - Impact of Solar and Wind Integration on Frequency Control System
IRJET -  	  Impact of Solar and Wind Integration on Frequency Control SystemIRJET -  	  Impact of Solar and Wind Integration on Frequency Control System
IRJET - Impact of Solar and Wind Integration on Frequency Control SystemIRJET Journal
 
Design and validation of piezoelectric energy harvesting systems
Design and validation of piezoelectric energy harvesting systemsDesign and validation of piezoelectric energy harvesting systems
Design and validation of piezoelectric energy harvesting systemsIlyas Caluwé
 
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemHigh Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemIJRES Journal
 

Tendances (20)

A study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellsA study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cells
 
IJSRED-V2I3P24
IJSRED-V2I3P24IJSRED-V2I3P24
IJSRED-V2I3P24
 
K0105292100
K0105292100K0105292100
K0105292100
 
Grid tied PV System using modular multilevel inverter
Grid tied PV System using modular multilevel inverterGrid tied PV System using modular multilevel inverter
Grid tied PV System using modular multilevel inverter
 
F1103024661
F1103024661F1103024661
F1103024661
 
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
IRJET- Simulation and Analysis of Photovoltaic Solar System for Different Wea...
 
A010230105
A010230105A010230105
A010230105
 
Iaetsd design, engineerning and analysis
Iaetsd design, engineerning and analysisIaetsd design, engineerning and analysis
Iaetsd design, engineerning and analysis
 
LED-Lamp Design for Renewable Energy-Based DC House Application
LED-Lamp Design for Renewable Energy-Based DC House ApplicationLED-Lamp Design for Renewable Energy-Based DC House Application
LED-Lamp Design for Renewable Energy-Based DC House Application
 
Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...
Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...
Design of Soft Switching Converter with Digital Signal Processor Based MPPT f...
 
Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...
Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...
Estimation of Photovoltaic Module Parameters based on Total Error Minimizatio...
 
Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...
Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...
Ijaems apr-2016-3 A Study of nature of the Photovoltaic modules under the inf...
 
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
A New Simulation Approach of 3-Φ Transformer-less Grid Connected PV Inverter ...
 
Modeling of 185W of mono-crystalline solar panel using MATLAB/Simulink
Modeling of 185W of mono-crystalline solar panel using MATLAB/SimulinkModeling of 185W of mono-crystalline solar panel using MATLAB/Simulink
Modeling of 185W of mono-crystalline solar panel using MATLAB/Simulink
 
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
Modeling and Simulation of Grid Connected PV Generation System Using Matlab/S...
 
A High Static Gain Modified SEPIC Converter With PV Module and MPPT
A High Static Gain Modified SEPIC Converter With PV Module and MPPTA High Static Gain Modified SEPIC Converter With PV Module and MPPT
A High Static Gain Modified SEPIC Converter With PV Module and MPPT
 
PV_module_model
PV_module_modelPV_module_model
PV_module_model
 
IRJET - Impact of Solar and Wind Integration on Frequency Control System
IRJET -  	  Impact of Solar and Wind Integration on Frequency Control SystemIRJET -  	  Impact of Solar and Wind Integration on Frequency Control System
IRJET - Impact of Solar and Wind Integration on Frequency Control System
 
Design and validation of piezoelectric energy harvesting systems
Design and validation of piezoelectric energy harvesting systemsDesign and validation of piezoelectric energy harvesting systems
Design and validation of piezoelectric energy harvesting systems
 
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation SystemHigh Proficiency Grid ConnectedPhotovoltaic Power Generation System
High Proficiency Grid ConnectedPhotovoltaic Power Generation System
 

Similaire à PV Module Power Dissipation Under Partial Shading

International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
 
New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...
New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...
New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...IAES-IJPEDS
 
IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530Vijay Kannan
 
Performance analysis of active clamped interleaved fly-back inverter for phot...
Performance analysis of active clamped interleaved fly-back inverter for phot...Performance analysis of active clamped interleaved fly-back inverter for phot...
Performance analysis of active clamped interleaved fly-back inverter for phot...eSAT Journals
 
SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...
SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...
SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...ecij
 
IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...
IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...
IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...IRJET Journal
 
A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...
A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...
A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...IJMER
 
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...IRJET Journal
 
Performance analysis of active clamped interleaved
Performance analysis of active clamped interleavedPerformance analysis of active clamped interleaved
Performance analysis of active clamped interleavedeSAT Publishing House
 
2005_A Review of Single-Phase Grid-Connected Inverters.pdf
2005_A Review of Single-Phase Grid-Connected Inverters.pdf2005_A Review of Single-Phase Grid-Connected Inverters.pdf
2005_A Review of Single-Phase Grid-Connected Inverters.pdfPKSahu6
 
Simulation Model for PV Array & Its Characteristics
Simulation Model for PV Array & Its CharacteristicsSimulation Model for PV Array & Its Characteristics
Simulation Model for PV Array & Its CharacteristicsIJEEE
 
Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...
Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...
Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...IJLT EMAS
 
IRJET- High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...
IRJET-  	  High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...IRJET-  	  High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...
IRJET- High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...IRJET Journal
 
A fuzzy based pv fed brushless dc motor
A fuzzy based pv fed brushless dc motorA fuzzy based pv fed brushless dc motor
A fuzzy based pv fed brushless dc motoreSAT Publishing House
 
A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...
A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...
A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...ijiert bestjournal
 
Simulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemSimulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemIJECEIAES
 
A study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellsA study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellseSAT Publishing House
 
A study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellsA study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellseSAT Publishing House
 
IRJET- Power Quality Improvement in Solar by using Fuzzy Logic Controller
IRJET-  	  Power Quality Improvement in Solar by using Fuzzy Logic ControllerIRJET-  	  Power Quality Improvement in Solar by using Fuzzy Logic Controller
IRJET- Power Quality Improvement in Solar by using Fuzzy Logic ControllerIRJET Journal
 

Similaire à PV Module Power Dissipation Under Partial Shading (20)

International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 
New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...
New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...
New Structure for Photovoltaic SystemApplications with Maximum Power Point Tr...
 
IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530IJSETR-VOL-2-ISSUE-7-1526-1530
IJSETR-VOL-2-ISSUE-7-1526-1530
 
Performance analysis of active clamped interleaved fly-back inverter for phot...
Performance analysis of active clamped interleaved fly-back inverter for phot...Performance analysis of active clamped interleaved fly-back inverter for phot...
Performance analysis of active clamped interleaved fly-back inverter for phot...
 
SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...
SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...
SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACT...
 
IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...
IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...
IRJET- FPGA Controlled Three Level Diode Clamped Multilevel Inverter for Sola...
 
A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...
A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...
A Single Phase Eleven Level Cascaded H-Bridge Multilevel Inverter for Photovo...
 
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
Simulation of MPPT Controller for photovoltaic system Grid-connected using Mo...
 
Performance analysis of active clamped interleaved
Performance analysis of active clamped interleavedPerformance analysis of active clamped interleaved
Performance analysis of active clamped interleaved
 
2005_A Review of Single-Phase Grid-Connected Inverters.pdf
2005_A Review of Single-Phase Grid-Connected Inverters.pdf2005_A Review of Single-Phase Grid-Connected Inverters.pdf
2005_A Review of Single-Phase Grid-Connected Inverters.pdf
 
Simulation Model for PV Array & Its Characteristics
Simulation Model for PV Array & Its CharacteristicsSimulation Model for PV Array & Its Characteristics
Simulation Model for PV Array & Its Characteristics
 
Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...
Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...
Modeling Combined Effect of Temperature, Irradiance, Series Resistance (Rs) a...
 
IRJET- High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...
IRJET-  	  High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...IRJET-  	  High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...
IRJET- High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tie...
 
A fuzzy based pv fed brushless dc motor
A fuzzy based pv fed brushless dc motorA fuzzy based pv fed brushless dc motor
A fuzzy based pv fed brushless dc motor
 
Photovoltaic Emulator for Grid-connected Quasi-Z-Sorce Inverter
Photovoltaic Emulator for Grid-connected Quasi-Z-Sorce InverterPhotovoltaic Emulator for Grid-connected Quasi-Z-Sorce Inverter
Photovoltaic Emulator for Grid-connected Quasi-Z-Sorce Inverter
 
A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...
A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...
A REVIEW ON EVALUATION OF PV MODELS BASED ON AN INTEGRATION USING A NEW CONFI...
 
Simulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic systemSimulation of various DC-DC converters for photovoltaic system
Simulation of various DC-DC converters for photovoltaic system
 
A study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellsA study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cells
 
A study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cellsA study on modelling and simulation of photovoltaic cells
A study on modelling and simulation of photovoltaic cells
 
IRJET- Power Quality Improvement in Solar by using Fuzzy Logic Controller
IRJET-  	  Power Quality Improvement in Solar by using Fuzzy Logic ControllerIRJET-  	  Power Quality Improvement in Solar by using Fuzzy Logic Controller
IRJET- Power Quality Improvement in Solar by using Fuzzy Logic Controller
 

Plus de IJECEIAES

Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...IJECEIAES
 
Prediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regressionPrediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regressionIJECEIAES
 
Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...IJECEIAES
 
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...IJECEIAES
 
Improving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learningImproving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learningIJECEIAES
 
Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...IJECEIAES
 
Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...IJECEIAES
 
Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...IJECEIAES
 
Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...IJECEIAES
 
A systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancyA systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancyIJECEIAES
 
Agriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimizationAgriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimizationIJECEIAES
 
Three layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performanceThree layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performanceIJECEIAES
 
Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...IJECEIAES
 
Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...IJECEIAES
 
Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...IJECEIAES
 
Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...IJECEIAES
 
On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...IJECEIAES
 
Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...IJECEIAES
 
A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...IJECEIAES
 
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...IJECEIAES
 

Plus de IJECEIAES (20)

Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...
 
Prediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regressionPrediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regression
 
Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...
 
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...
 
Improving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learningImproving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learning
 
Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...
 
Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...
 
Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...
 
Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...
 
A systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancyA systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancy
 
Agriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimizationAgriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimization
 
Three layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performanceThree layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performance
 
Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...
 
Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...
 
Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...
 
Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...
 
On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...
 
Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...
 
A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...
 
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
 

Dernier

(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )Tsuyoshi Horigome
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 

Dernier (20)

(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 

PV Module Power Dissipation Under Partial Shading

  • 1. International Journal of Electrical and Computer Engineering (IJECE) Vol. 11, No. 2, April 2021, pp. 1029~1035 ISSN: 2088-8708, DOI: 10.11591/ijece.v11i2.pp1029-1035  1029 Journal homepage: http://ijece.iaescore.com Power dissipation analysis of PV module under partial shading Byunggyu Yu1 , Seok-Cheol Ko2 1 Division of Electrical, Electronic and Control Engineering and Regional-Industrial Application Research Institute and Institute of IT Convergence Technology, Kongju National University, Republic of Korea 2 Industry-University Cooperation Foundation and Regional-Industrial Application Research Institute, Kongju National University, Republic of Korea Article Info ABSTRACT Article history: Received Aug 19, 2020 Revised Sep 4, 2020 Accepted Oct 7, 2020 Photovoltaic (PV) generation has been growing dramatically over the last years and it ranges from small, rooftop-mounted or building integrated systems, to large utility scale power stations. Especially for rooftop-mounted PV system, PV modules are serially connected to match with PV inverter input voltage specification. For serially connected PV system, shading is a problem since the shaded PV module reduces the output whole string of PV modules. The excess power from the unshaded PV module is dissipated in the shaded PV module. In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis for series connected PV modules. The specific current and voltage operating point of the shaded PV module are analyzed under shading. PSIM simulation tool is used to verify the power dissipation analysis. When there is no bypass diode and three solar modules are connected in series, upto 39.1% of the total maximum PV power is dissipated in the shaded PV module. On the other hand, when the bypass is attached, 0.3% of the total maximum power is generated as a loss in the shaded PV module. The proposed analysis technique of shaded PV module could be used in PV system performance analysis, especially for maximum power point tracking (MPPT) performance. Keywords: Hotspot Partial shading Power dissipation PV generation PV module configuration PV modules This is an open access article under the CC BY-SA license. Corresponding Author: Byunggyu Yu Division of Electrical, Electronic and Control Engineering and Institute of IT Convergence Technology Kongju National University, 1223-24 Cheonan Daero Seobuk-gu, Cheonan-Si, Chungnam, 330-717, Republic of Korea Email: bgyuyu@kongju.ac.kr 1. INTRODUCTION Photovoltaic (PV) generation is to convert sunglight directly into electricity by using PV module, which is called as the photovoltaic effect. As PV is one of the increasing important renewalbe energy resources, and it has been widely spread around the world [1, 2]. Recently, PV generation has become cost competitive in many regions and it consits of three market segments: residential rooftop [3-5], commercial rooftop [6-7], and ground mount utility scale systems [8-10]. Especially, the number of residential PV system has grown rapidly over the past years [11, 12] and sized to provide power that would offset as much of the household load as possible. An averaging around 5kW was specified based on the predicted load for a peak day [13]. PV modules are serially connected for residential application by matchng with PV string inverter input voltage specification [14-16]. For serially connected PV system, shading, such a s birds, tree shadows, is a problem since the shaded PV module reduces the output whole string of PV modules [17-19]. The excess power from the unshaded PV module is dissipated in the shaded PV module and it is shown that temperature of the shaded PV module or cell rises as hot spot [20-22]. Until now, research on the shaded PV modules or
  • 2.  ISSN: 2088-8708 Int J Elec & Comp Eng, Vol. 11, No. 2, April 2021 : 1029 - 1035 1030 cells has been mainly on the performance of the whole PV system, and there has been little analysis on the circuit and power dissipation of each PV module [23-25]. In this paper, power dissipation of PV module under partial shading is analyzed with circuit analysis for series connected PV modules. Firstly, analysis of PV module power dissipation is presented accroding to the amount of the electric load and circuit operation of each PV module is also introduced. Then, in order to verify the analysis technique, the simulation results are presented. 2. ANALYSIS OF PV MODULE POWER DISSPATION Figure 1 shows the voltage-current characteric curve of PV module by the operating point, which can be classified into three regions. Region 1 is in the power generation mode, which is a desirable condtion to achieve the electric power from the sunlight. However, PV modules are conducted as a power load in Region 2 and 3. The power dissipation in Region 2 and 3 happen under abnormal environmental conditions like partial shading. More specifically, reverse voltage of Region 2 appears in the series-connected PV cells or modules, reverse current of Region 3 appears in the parallel-connected PV cells or modules under partial shading. Figure 1. Voltage-current characteristic curve of PV module by the operation point In this paper, the scope of power dissipation analysis is limited to a series-connected PV modules to focus on bypass diode performance of PV module. In other words, Region 2 of PV module characteristic curve is analyzed under shading condition. In order to analyze the performance of PV module power generation under shading, the following condition is assumed as follows: Figure 2 shows the PV modules configuration in series to analyze the effect of shading and performance of bypass diodes. Without any shading, n PV modules in series shows voltage-current curve in Figure 3. In the case of n PV modules without bypass didoe under partial shading, the available power to be generated is reduced becasue there is no path for the other current from no shaded (n-1) PV modules. This current makes the reverse voltage of the shaded PV module. Thus, the power is dissipated in the area of Figure 4. The amount of power dissipation can be quantitized as (1). 𝑃𝑑𝑖𝑠𝑠 = 𝑉𝑝𝑣,𝑛𝑡ℎ × 𝐼𝑠ℎ𝑎𝑑𝑖𝑛𝑔 (1) while shading on nth PV module, the nth PV voltage ranges from -Vop to zero for power dissipation and the nth PV current ranges from Ishadning,nth to Isc,nth. The amount of power dissipation is dominated from the other (n-1) PV modules’ voltage. Specifically, the power dissipation is maximized at the short circuit condition, R2,min. In the same way, when n PV modules with bypass diode under partial shading, the generated power can be maximized compared with the previous case, because the bypass diode provides the path for the other current from no shaded (n-1) PV modules. The reverse voltage of the shaed PV module is dominated by the bypass diode threshold voltage, which is normaly 0.7V. Thus, as shown in Figure 5, the power dissipation is
  • 3. Int J Elec & Comp Eng ISSN: 2088-8708  Power dissipation analysis of PV module under partial shading (Byunggyu Yu) 1031 reduced dramatically by the low reverse voltage 0.7 V of the shaded nth PV module, compared with the case of no bypass diode. In short, the amount of power dissipation can be quantitized as (2). 𝑃𝑑𝑖𝑠𝑠 = 0.7 × 𝐼𝑠ℎ𝑎𝑑𝑖𝑛𝑔 (2) (a) (b) (c) Figure 2. PV modules configuration in series, (a) case 1: PV connection under no shading, (b) case 2: PV connection without bypass didoes under partial shading, (c) case 3: PV connection with bypass diodes under partial shading Figure 3. Voltage-current characteristic curve of n PV modules in series under no shading (a) (b) Figure 4. Voltage-current characteristic curve of n PV modules in series without by pass diodes under partial shading, (a) overall curve of n PV modules, (b) Separate curves of both a PV module under shading and the others under no shading
  • 4.  ISSN: 2088-8708 Int J Elec & Comp Eng, Vol. 11, No. 2, April 2021 : 1029 - 1035 1032 (a) (b) Figure 5. Voltage-current characteristic curve of n PV modules in series with bypass diodes under partial shading, (a) overall curve of n PV modules, (b) separate curves of both a PV module under shading and the others under no shading 3. SIMULATION RESULTS In order to verify the analysis of power dissipation, three PV modules in series are tested in PSIM simulation software. A commercial PV module datasheet is used for the specification of a PV module to simulate three PV modules in series under partial shading, where maximum power Pmax is 360W, voltage at maximum power Vmp is 38 V, current at maximum power is 9.47 A, open circuit voltage Voc is is 47 V, and short circuit current Isc is 9.72 A. Three different scenarios as shown in Figure 2 are considered for three PV modules (n=3) in series, in order to verify the analysis of power dissipation. Figure 6 shows characteristic curves of three PV modules in series with regards to shading and bypass diode. For Case 1, there is no distortion of the characteristic curves on PV current and PV power with the nominal values under no shading, and there is only one global maximum power point (MPP). Compared with Case 1, the results of Case 2 and Case 3 under shading are shown in Figure 6. Without bypass diode, the short circuit current for Case 2 is reduced from 9.72 A to 4.861A becasue there is no path for the other current from no shaded two PV modules. Accordingly, the maximum power with only one global MPP is decrease from 1080W to 607 W. The power degradation cause the PV module problem as hot spot problem. Hot spot heating occurs in a PV module under Case 2 while its operating current exceeds the reduced short circuit current. (a) (b) Figure 6. Characteristic curves of three PV modules in series with regards to shading and bypass diode, (a) voltage-current curve, (b) voltage-power curve For Case 3, there are two local MPP which are 713 W and 607 W because the bypass diode provides the path for the other current from no shaded two PV modules. Since the short circuit current isn’t reduced with bypass diode, the hotspot problem of Case 2 doesn’t occurs. Specific analysis of power dissipation for the shaded PV module and the other has been conducted. Figure 7 shows the voltage-current characteristic curve of three PV modules in series under partial shading. For Case 2, the voltage across the shaded 3rd PV module ranges from a negative value, -86.968V to a positive value, 46.263 V, as shown in Figure 7(a). While
  • 5. Int J Elec & Comp Eng ISSN: 2088-8708  Power dissipation analysis of PV module under partial shading (Byunggyu Yu) 1033 PV voltage is operated at a negative value, the shaded PV module dissipates its power upto 422.751 W as shown in Figure 8, which can be analyzed by (1). In other words, when there is no bypass diode and three solar modules are connected in series, upto 39% of the total power generated by the shaded PV module is dissipated, which cause a hotspot. For Case 3, the negative voltage across the shaded 3rd PV module is limited to 0.7 V as shown in Figure 7(b), which is the threshold voltage of the bypass diode. The power dissipation of the shaded PV module is limited 3.402W as shown in Figure 8. Which means that just 0.3% power loss of the total power available occurs when the bypass diodes are attached to the PV modules. Therefore, it is concluded that power dissipation can be dramatically reduced by the bypass diode. This result can be applied into a PV module, which is consisted with PV cells and bypass diodes. (a) (b) Figure 7. Voltage-current characteristic curve of three PV modules in series under partial shading, (a) without bypass diode in case 2, (b) with bypass didoe in case 3 Figure 8. Power loss comparison of shaded PV modules under partial shading with respect to bypass diode 4. CONCLUSION This paper presents the study on the power dissipation of PV module under partial shading with circuit analysis for series connected PV modules. For verify the analysis method, three commercial PV modules in series are considered by PSIM simulation under partial shading. When there is no bypass diode and three solar modules are connected in series, upto 39% of the total maximum PV power is dissipated in the shaded PV module. On the other hand, when the bypass was attached, 0.3% of the total maximum power was generated as a loss in the shaded PV module. As a result, the circuit operation of the shaded PV modules was verified as the analysis method to casue so called hot spot. The proposed analysis method on power dissipation of the shaded PV module can be used in the application of PV system performance improvement to prevent hotspot and acheive higher power generation from the shaded PV string.
  • 6.  ISSN: 2088-8708 Int J Elec & Comp Eng, Vol. 11, No. 2, April 2021 : 1029 - 1035 1034 ACKNOWLEDGEMENTS This work was supported by the 2020 sabbatical year research grant of Kongju National University. REFERENCES [1] S. Eftekharnejad, G. Heydt, and V. Vittal, "Optimal Generation Dispatch With High Penetration of Photovoltaic Generation," IEEE Transactions on Sustainable Energy, vol. 6, no. 3, pp. 1013-1020, 2015. [2] P. Vithayasrichareon, G. Mills, and I. Macgill, "Impact of Electric Vehicles and Solar PV on Future Generation Portfolio Investment," IEEE Transactions on Sustainable Energy, vol. 6, no. 3, pp. 899-908, 2015. [3] R. Li and F. Shi, "Control and Optimization of Residential Photovoltaic Power Generation System with High Efficiency Isolated Bidirectional DC-DC Converter," IEEE Access, vol. 7, pp. 116107-116122, 2019. [4] Y. Sun, et al., "Artificial Neural Network for Control and Grid Integration of Residential Solar Photovoltaic Systems," IEEE Transactions on Sustainable Energy, vol. 8, no. 4, pp. 1484-1495, 2017. [5] M. Khan, et al., "Autoinspection and Permitting With a PV Utility Interface (PUI) for Residential Plug-and-Play Solar Photovoltaic Unit," IEEE Transactions on Industry Applications, vol. 53, no. 2, pp. 1337-1346, 2017. [6] S. Martin, et al., "Model to evaluate the system-wide impact of residential and commercial photovoltaic and storage units intended for self-consumption," IET Renewable Power Generation, vol. 13, no. 12, pp. 2111-2122, 2019. [7] N. Kandsamy, K. Kandasamy, and K. Tseng, "Loss-of-life investigation of EV batteries used as smart energy storage for commercial building-based solar photovoltaic systems," IET Electrical Systems in Transportation, vol. 7, no. 3, pp. 223-229, 2017. [8] X. Li, et al., "An Unmanned Inspection System for Multiple Defects Detection in Photovoltaic Plants," IEEE Journal of Photovoltaics, vol. 10, no. 2, pp. 568-576, 2020. [9] A. Sizkouhi, et al., "Automatic Boundary Extraction of Large-Scale Photovoltaic Plants Using a Fully Convolutional Network on Aerial Imagery," IEEE Journal of Photovoltaics, vol. 10, no. 4, pp. 1061-1067, 2020. [10] T. Kohno, et al., "Fault-Diagnosis Architecture for Large-Scale Photovoltaic Power Plants That Does Not Require Additional Sensors," IEEE Journal of Photovoltaics, vol. 9, no. 3, pp. 780-789, 2019. [11] D. W. H. Cai, et al., "Impact of residential PV adoption on Retail Electricity Rates," Energy Policy, vol. 62, pp. 830-843, 2013. [12] Y. Li, W. Gao, and Y. Ruan, "Performance investigation of grid-connected residential PV-battery system focusing on enhancing self-consumption and peak shaving in Kyushu, Japan," Renewable Energy, vol. 127, pp. 514-523, 2018. [13] D. Chung, et al., “U.S. Photovoltaic prices and cost breakdowns: Q1 2015 benchmarks for residential, commercial, and utility-scale systems,” NREL Technical Report, pp. 1-51, 2015. [14] M. Boztepe, et al, "Global MPPT Scheme for Photovoltaic String Inverters Based on Restricted Voltage Window Search Algorithm," IEEE Transactions on Industrial Electronics, vol. 61, no. 7, pp. 3302-3312, Jul. 2014. [15] C. Yu, et al., "Modeling and Analysis of Common-Mode Resonance in Multi-Parallel PV String Inverters," IEEE Transactions on Energy Conversion, vol. 34, no. 1, pp. 446-454, 2019. [16] A. Rana, M. Nasir, and H. Khan, "String level optimisation on grid-tied solar PV systems to reduce partial shading loss," IET Renewable Power Generation, vol. 12, no. 2, pp. 143-148, 2018. [17] M. Mohamed, A. Diab, and H. Rezk, "Partial shading mitigation of PV systems via different meta-heuristic techniques," Renewable Energy, vol. 130, pp. 1159-1175, 2019. [18] H. Sah, S. Nayyak, and S. Mishra, "Maximizing the Power Generation of a Partially Shaded PV Array," IEEE Journal of Eemerging and Selected Topic in Power Electronics, vol. 4, no. 2, pp. 626-637, 2016. [19] O. Bingol and B. Ozkaya, "Analysis and comparison of different PV array configurations under partial shading conditions," Solar Energy, vol. 160, pp. 336-343, Jan. 2018. [20] K. Kim and P. Krein, "Reexamination of Photovoltaic Hot Spotting to Show Inadequacy of the Bypass Diode," IEEE Journal of Photovoltaics, vol. 5, no. 5, pp. 1435-1441, 2015. [21] M. Dhuimish, "70% Decrease of Hot-Spotted Photovoltaic Modules Output Power Loss Using Novel MPPT Algorithm," IEEE Transactions on Circuits and Systems II: Express Briefs, vol. 66, no. 12, pp. 2027-2031, 2019. [22] D. Winston, "Efficient Output Power Enhancement and Protection Technique for Hot Spotted Solar Photovoltaic Modules," IEEE Transactions on Device and Materials Reliability, vol. 19, no. 4, pp. 664-670, 2019. [23] J. Ma, et al., "Detection and Assessment of Partial Shading Scenarios on Photovoltaic Strings," IEEE Transactions on Industry Applications, vol. 54, no. 6, pp. 6279-6289, 2018. [24] S. Mishra, H. Ziar, O. Isabella, and M. Zeman, "Selection Map for PV Module Installation Based on Shading Tolerability and Temperature Coefficient," IEEE Journal of Photovoltaics, vol. 9, no. 3, pp. 872-880, 2019. [25] J. Ahmed and Z. Salam, "An Improved Method to Predict the Position of Maximum Power Point During Partial Shading for PV Arrays," IEEE Transactions on Industrial Informatics, vol. 11, no. 6, pp. 1378-1387, 2015.
  • 7. Int J Elec & Comp Eng ISSN: 2088-8708  Power dissipation analysis of PV module under partial shading (Byunggyu Yu) 1035 BIOGRAPHIES OF AUTHORS Byunggyu Yu was born in Korea, in 1976. He received the BS and MS degrees in electrical engineering from Pusan University, Korea, in 2000 and from KAIST in 2002, respectively. Since 2002, he had been with the Korea Institute of Energy Research as a Research Fellow. In 2007, he started his RONPAKU doctoral degree program supported by a scholarship from the government of Japan at the Tokyo Polytechnic University, and he received the PhD degree in electrical engineering in 2010. Since 2012, he has been with Kongju National University as an assistant professor. His research interests include photovoltaic system including the module-integrated converter system and its control algorithm. Seok-Cheol Ko received his B. S., M. S., and Ph.D. degrees from Chonbuk National Univ., Korea in 1996, 2002, and 2005, respectively. Currently, he is a professor in the Industry- University Cooperation Foundation at Kongju National Univ., Korea.