ConnectM Offers “Energy Management Solution”
ConnectM offers its Energy Management solution (EMS) which optimizes any organizations’
energy consumption up-to 30%. ConnectM EMS provides justification of the sustainable
positive business impact. This significant business impact is powered by state of the art
Analytics based EMS technology.
• Optimized Energy consumption for lights
• Analytics & Self learning algorithms based decision making
• Switch OFF Delay, Seasonality of organizations & functions, time based
analytics, behavior based (Organization, Groups, projects, etc.,)
Page2
• Powered by Energy Management Software, Enterprise Solution Engine, Enterprise
Command Center, Energy Gateway, Energy Saver
• Wireless networked, Unique Network ID for all elements of network
• Value Added Features: Security Analytics, Fire Analytics, Productivity Analytics,
Real Estate Analytics, “As Is Condition”
2. E-BMS System Architecture
ZigBee
ZigBee
AHUs CTLR CTLR Chillers
ZigBee
ZigBee
Precision
CTLR
AC CTLR Plant room
equipments
ZigBee
ZigBee
TFAs CTLR DGs
CTLR
ZigBee
ZigBee
UPS CTLR CTLR
Energy &
Water Meters
ZigBee Co-ordinator
Application Server
Note:
1. Each Controller (CTLR) has its own in-built I/Os and necessary communication ports
3. What is a Energy-BMS (E-BMS) System
“Energy BMS is a Intelligent system designed to address all the energy
consuming assets in buildings or any other infrastructure for the purpose
of measuring, monitoring, controlling and conserving Energy
Save
Control
Measure Monitor
BUILDING
4. 1. HVAC Plant Optimization System
Plant Room equipments are designed to meet the cooling requirement of the building in a
worst case scenario of climate and occupancy. The load in the building is a function of
internal and external load factors and is hence dynamic
Plant Room Optimization System is an external system that helps map operation of Plant
Room equipment to exactly meet building load and hence ensure that equipments are
operation in their best possible efficiency zones.
Chiller COP
Chiller 1 6.00
5.00
4.00
Chiller 2
3.00
2.00
Chiller 3 1.00
CHW pump
0.00
100% 90% 80% 70% 60% 50% 40% 30% 20%
Typical Plant Room
Benefit to User :
1. Plant Room Equipments operate to closely map building load. Chillers operate in their
best possible efficiency zone for operation.
2. Energy Savings of 6% - 10% on Plant Room Energy Consumption
5. 2.Chiller Performance and Health Monitoring
Chillers are the single most energy consuming equipment in the plant room and in the
entire building.
Chillers have a dynamic efficiency which is highly dependent on condition, quality of
maintenance, water quality and other operating parameters
Monitoring of Efficiency and Capacity of this equipment gives a real time information
about the condition of the equipment and alerts incase of abnormal energy consumption
Benefit to user :
1. Real time monitoring of chiller capacity, energy consumption and Efficiency
2. AMCs of the equipment can be performance based that just being a functional AMC
3. On availability of third party integration card other parameters can also be remotely
integrated
Chiller 1
Chiller 2
Chiller 3
CHW pump
Chillers are the most energy consuming Asset in a Building. Their
energy consumption is dynamic in nature
6. 3. Intelligent Indoor Lighting Control based on Occupancy
Lighting contributes a significant amount of energy consumption in any building.
Occupants in buildings generally use their workstations / cabins with about 65 – 70%
occupancy levels. This offers a high potential to save on lighting in the occupied area
The Occupancy cum Day Light sensors offered with the E-BMS help take advantage of
this variability and availability of Day Light to save lighting energy.
Benefit to User :
1. Net energy savings on lighting energy. The solution takes advantage of workspace
variability in buildings
2. Day light harvesting in areas where natural light is available
7. 3. How Indoor Lighting Control works
Occupancy cum Day light sensors
provide the information for Lighting on/off
Actual Installation
8. 4. HVAC Low-side Operations optimization
Occupancy information as a strategy is used to control the Start & Stop operation for
Small HVAC equipment such as Split units and Cassette units.
Scheduling is used as a strategy to control other low side equipments like
AHU, Package Units.
Any saving on the running hours for low-side equipment offer direct savings on low-side
energy consumption on low-side equipment and indirect saving on High side.
Benefit to User :
1. Energy saving on low side as well as high side equipment on account of optimal
start, stop operation.
9. 6. DG Set Health and Performance Monitoring
DG sets operate on expensive fuel, the cost of power generated out of DG set is more
than double the cost of EB power. Hence DG set efficiency has a significant impact on
monthly energy bills even if they are operating for a very small period of time.
DG Set Energy Management Modules monitors,
DG Set energy generation monitoring
DG set fuel consumption
Specific fuel consumption of DG Sets to know Power generated per lit of fuel used. DG
Set efficiency monitoring
DG Set fuel tank level indicator
Benefit to User :
1. Monitoring of DG set efficiency on real time.
Minimize minimize monetary impact of
inefficiency of DG Sets
2. AMCs of the equipment can be performance
based that just being a functional AMC
3. On availability of third party integration card
other parameters can also be remotely
integrated
10. 7. Data Center Precision AC Health & Performance
Monitoring (Temperature, Humidity, Energy)
Data Center PAC’s on account of the 24x7
operation significantly contribute to the energy
bills and are critical to operations team.
Monitoring of energy consumption and
operation of individual PAC units is of utmost
importance to identify energy consumption in
the data centre and identify abnormal patterns.
The Data Center PAC energy management
module includes,
PAC Energy Consumption of each unit
Average Energy consumption for PAC
Data Center Temperature monitoring & Alarm
using Temperature sensors.
A third party integration card is required for
this purpose
Benefit to User :
1. Monitoring of energy consumption and operation of each PAC on real time.
Minimize minimize monetary impact of inefficiency of any unit
2. Monitoring of critical temperature parameters in the Data Center
11. 8. UPS Performance and Health Monitoring
Uninterrupted power supply system play a very important role to provide uninterrupted
back-up power for critical areas in buildings.
Their monitoring for operation and performance parameters is important to ensure
maximum availability and low O&M costs.
The UPS monitoring module includes monitoring of operating parameters like,
Voltage and frequency
% Loading
Temperature in the area
Health monitoring & Predictive Diagnostics
A third party integration card is required for this purpose
Benefit to User :
1. Monitoring operating parameters and
alarms for UPS using Modbus or SNMP
communication hardware.
2. Predictive Diagnostics on UPS helps
avoid major break-downs
12. 9. Energy Sub-metering in the Facility
It is of high benefit to a facility owner / operator if E-BMS
he has information about the energy consumption
in this facility, plant or factory at sub zonal levels.
Floor Level
Energy
These levels could be at equipment Consumption
level, building level, area level, floor level, zone Smart Meters
(Wireless)
level like lighting on each floor or AC on each floor
and so on.
Equipment Level
Understanding of the distribution of energy Energy
Consumption
consumption helps user identify areas of high and Smart Meters
low priority with regards to his energy costs (Wireless)
Benefit to User : Plant Room
Energy
Smart Meters
Consumption
1. Energy Sub-metering to understand (Wireless)
energy consumption distribution in the
facility.
Data Center
2. Analytics based on this information Energy
Consumption
Smart Meters
(Wireless)
13. Thank you for your time
Thank You
ConnectM Technology Solutions Pvt. Ltd.
ConnectM Technology Solutions Pvt. Ltd.
4th Floor, KMJ Arcadia,
5th Block, Koramangala
Bangalore – 560095.
U www.connectm.com