SlideShare une entreprise Scribd logo
1  sur  4
Télécharger pour lire hors ligne
Passive housing and
the concept of the
passive solar house
have been around
for many years. In
Ireland we have many
examples of what
was known as the
passive solar house.
It was quite differ-
ent to the Passivhaus concept developed
and made successful by Wolfgang Feist
and the Passivhaus Institut in Germany.
The passive solar house in Ireland
The passive solar house, particularly in
Ireland, did not feature the attention to
U-value, air-tightness and cold bridging
that is now prevalent in low energy housing.
There were several reasons for this. We
had not developed the methods of build-
ing which were readily and economically
available to achieve very low U-values in
practice. Some wall constructions were
designed to give low U-values but in real-
ity did not do so in practice due to site
construction problems. Similarly, triple-
glazed windows were not economically
available through Irish suppliers. It was
found difficult to build houses to levels
Passivhaus
or passive solar house?
A PASSIVE SOLAR HOUSE CONCEPT DESIGNED
FOR IRELAND
Few concepts in sustainable design have caught on like the passive house. Since the con-
struction of the first passive house in Germany in 1990, an estimated 15 to 20,000 houses
have been built to what is arguably the world’s leading low energy building standard. Draw-
ing from his experience in sustainable building since the early 1980s, Bill Quigley of NuTech
Renewables posits an alternative approach.
CI 71
of air-tightness that were deemed neces-
sary for low energy housing, and elimi-
nating thermal bridging was difficult given
the methods of construction and the methods
of analysis available at the time. It’s fair
to say that the Irish construction indus-
try simply was not ready to be forced
into the highly specialised techniques to
achieve the U-values and air-tightness re-
quired and also, and probably most im-
portantly, there simply was not the will
to deliver a near ‘zero-energy’ house.
This gave rise to an extraordinary situa-
tion, where the ‘low energy house’ in practice
could cost considerably more to run than
the actual design amount as is illustrated
in figure 1. If the actual heat losses are
doubled – which could well be the case
because of poorly installed insulation,
lack of air-tightness and serious thermal
bridging – then the running costs tripled
over the design value as the amount of
solar gain remained approximately the same.
With this knowledge and with the growing
number of architects and engineers interested
in this area of low energy house technol-
ogy, a number of examples were built.
Probably the first serious example of a passive
solar house in Ireland was the Garristown
house in County Dublin, built between
1979 and 1980. The concept design was
by the well known engineer and special-
ist in thermodynamics John Cash, for whom
the house was actually being built. Dun-
can Stewart was the architect and other
colleagues of John and Duncan in DIT were
also involved in various aspects of the
house design. Huge efforts were made to
ensure that this house achieved its de-
sign values and indeed it was such a suc-
cess that it sparked considerable interest
in this area. As can be seen from the photo
this reasonably well insulated house fea-
tured a massive solar wall of some 110 m2
.
Another example of a passive solar house
built a little later than the Garristown house
was the Knocklyon solar house, which
was built and monitored between 1983
and 1989. This house featured an early
version of a solar heating and ventilation
system which eventually evolved into
NuTech’s Sunwarm system. This early
system had 40m2
(gross) of air solar col-
lectors. In reality this was a passive solar
house with an active solar feature. The
collector array fed energy into the heat-
ing and ventilating system and into the
domestic hot water system. The wall in-
sulation in this house – an early version
of bonded bead – proved troublesome
and had to be replaced by blown fibre-
glass. Difficulties were also experienced
in attaining a high degree of air-tightness.
Many different systems were tried and
tested in this house including air solar
collectors, phase change material heat storage
and solar assisted heat pump technology,
to name a few. A huge amount of infor-
mation was gathered by way of the data
monitoring system, the results of which
were reported to the energy directorate
of the European Commission.
The Knocklyon project in particular led the
way to a simplified passive solar house
concept developed by Mark Forkin and I
at NuTech Renewables. This concept can
achieve the same results as a more ex-
pensive-to-build passive house. Details
of this system together with a compari-
son will be given later in this article. 
Figure 1: effects on energy usage with increased heat loss characteristic
(above) Ireland’s first example of a passive solar house in Garristown, County Dublin, fea-
tured a solar wall of some 110m2
; (below) the Knocklyon solar house featured a solar heat-
ing and ventilation system; (opposite, top) a clay / straw passive house in Tattendorf,
Austria; (opposite, bottom) a NuTech designed passive solar house built with KTF’s inno-
vative timber frame system
CI 73
The passive house concept
The passive house concept as put forward
by the Passivhaus Institut is a very excit-
ing development and is of its time, as the
fabric elements and the systems involved
are now fully developed and widely available.
The basic requirements are:
• The house will use not more than
15 kWh/m2
per year of delivered
energy for space heating.
• The house will have a specific
annual heating load of less than
10 W/m2
. This does take into account
the heat gains by way of solar
gains through the windows and
the internal heat gains due to
occupancy. Hence, it should be
noted that this is a different figure
to the energy required to meet
the specific heat loss characteristic
of a house for a given temperature
difference.
• The air-tightness of the house will
be such that the air infiltration
rate will be less than 0.6 air changes
per hour at 50 Pa.
• Thermal bridging will be reduced
to a minimum.
• A heat recovery ventilation system
is used to supply the necessary
air for ventilation. It must have
an efficiency of more than 75
per cent. The system will supply
at least 0.3 ACH of fresh air.
• A solar water heating system should
be used. Typically, a 3m2
Evacuated
Tube Array with a 300 litre domestic
hot water cylinder will suffice.
By these means the necessity for a full
primary central heating system are negated.
It is generally sufficient to add any extra
energy by way of energy delivered from
an internal wood pellet stove normally
placed in the fireplace of the house, or by
way of a small heat pump which is extracting
energy out of the extracted air which has
already gone across the HRV unit. The design
of this unit is catered for in the Passive
House Planning Package (PHPP) software.
PHPP is a most useful and comprehensive
tool to aid the designer in arriving at a
satisfactory solution based on all of the above
points. To use this package will require
most designers to undertake a certain amount
of training. To date courses are being of-
fered by SEI/REIO and by Nicer Training.
Typically, to satisfy the above criteria the
fabric U-values must be less than or equal
to the following1
:
The following points should be given
careful consideration:
• An air infiltration level of less than
0.6 ACH at 50 Pa is very low indeed.
It represents an actual infiltration
rate at normal pressure of less
than 0.03 ACH. It would be our
view that with only 0.3 ACH of
fresh air being delivered by way
of the HRV system, consideration
would have to given to the humidity
level in the house in winter as it
could drop to very low levels
indeed – a figure of 35 per cent
relative humidity at 20o
C.
• ThedraftPartFofbuildingregulations
call for a fresh air requirement
of 0.3 litres of fresh air per second
per m2
of floor area. This must be
taken into account and supersedes
any other requirements as set
out in the PHPP.
• At this level of air-tightness, great
care would be required in the fitting
and use of an internal wood pellet
stove to ensure that there was
no depressurisation in the room
it is sited. Also, the stove would
have to be room sealed – in other
words its combustion air would
have to come from outside – as
it should in all low energy houses.
• The difficulty in achieving this
level of air-tightness should not
be underestimated.
• If the temperature of the house
should drop due to non-occupancy
in winter, then the power required
in the heating system would have
to be greater than 1200 W in order
that the house would heat-up in
a short time as power will be
required to overcome the thermal
response/thermal mass of the
house. Alternatively, homeowners
should be told to leave the
heating on even when they are
away as it will use so little energy
in the first place.
• To save costs some passive house
designers use a direct acting
electric heater in the air duct to
provide back-up heating. It should
be remembered that when this
is taken into account in SEI’s DEAP
calculation a severe penalty is
incurred as the use of electrical
energy is multiplied by a factor
of 2.7. Very often it can move
the rating of the house on the BER
scale from being an A2 house to
a B2 rating.
• Large areas of south-facing and
indeed east- and west-facing glazing
shouldbegivencarefulconsideration.
The possibility of overheating
due to solar gains through these
windows must be considered
and appropriate steps taken.
• It is vitally important that the
fabric thermal performance levels
are achieved in practice. If
there is only a 1200 W heater to
cater for deficiencies and if the
actual heat losses were somewhat
higher than the design, then it
would be disastrous for the comfort
levels experienced by the home
owner and the running costs would
escalate accordingly.
There is no doubt that if all of the criteria
are adhered to rigidly then a low energy
house will result. Comfort levels will be
satisfactory and running costs will be very
low. However, it is important that all of
the above points are taken into consider-
ation by the designer and the builder.
The NuTech passive solar house concept
The NuTech passive solar house concept
is a little different. It was devised originally
by Mark Forkin and this author out of the
design and systems used in the original
passive solar house in Knocklyon. All of
the technologies developed have been
rigorously tested over the past 20 years.
In essence, the U-values arrived at are a
little less strict in certain circumstances
over the PHI values to ensure cost breaks
are achieved and then this is compensated
for by way of a larger solar array of evac-
uated tubes delivering energy into the HRV
system even in cloudy weather (hence the
reason for using evacuated tubes over flat
plate collectors). The thinking is that as
insulation levels get higher and higher it
is a clear case of diminishing returns which
are, as mentioned, offset by the amount
of energy delivered to heating by way of
the solar array. NuTech are in full agree-
ment that high levels of air-tightness are
essential. The reduction in thermal bridging
is also vitally important as this has an
enormous effect on the overall heat loss
characteristic (W/K) of the house.
Typically, the NuTech requirements for
the fabric U-values must be less than or
equal to the following:1
As can be seen there are some essential
differences to the typical PHI requirements.
The external wall U-value is raised to
0.16 W/m2
K as it can be achieved in tim-
ber frame with a reasonably sized stud
which then has internal insulation fixed
to reduce the effect of thermal bridging.
The window U-value is raised to 1.2 W/m2
K
as it then allows the use of well designed
double glazing rather than the more ex-
pensive triple glazing unit. The level of
air infiltration has been raised to 1.0 ACH 
U-Value (W/m2K)
Ground floor 0.12
External wall 0.13
Roof 0.14
Windows and doors 0.80
U-Value (W/m2K)
Ground floor 0.12
External wall 0.16
Roof 0.14
Windows and doors 1.20
Infiltration level 1.0 ACH at 50Pa
Figure 2: a schematic of the NuTech integrated solar heating and HRV unit in a
passive solar house
CI 75
at 50 Pa – a difficult but more achievable
target which also helps reduce construc-
tion costs. Finally the energy from at least
a 6m2
evacuated tube solar array is inte-
grated into the HRV system, thus solar
heated air is being circulated to all rooms
within the house even in dull weather. The
heat generator, whether it is an internal
wood pellet boiler or an air to water heat
pump is also integrated into this system.
This fully integrated system is controlled
by way of the NuTech intelligent renew-
able energy system (IRES) controller.
As regards thermal bridging, systems have
been developed with the timber frame
company KTF Ltd., such that the amount
of thermal bridging is hugely reduced by
way of the insulation systems and partic-
ularly by way of details around the win-
dows and doors. As mentioned above, this
is vitally important. It is worth remembering
that if the thermal bridging factor in the
DEAP analysis is 0.08 W/m2
K then the U-
value for all of the elements is increased
by this amount. A wall U-value of 0.16
W/m2
K therefore becomes 0.24 W/m2
K in
the overall calculation. It is that serious.
Thispassivesolarhousesystemhasmanystrong
features. It has reasonably low U-values for
all of the fabric items, and is tested to achieve
less than 1.0 ACH at 50 Pa. It integrates the
energy from the solar array into the HRV
system, and similarly integrates energy from
the back-up boiler (internal wood pellet
or heat pump) into the HRV system.
There is also a facility to have filtered re-
circulated air within the system thereby
allowing 5 kW to 10 kW of heat to be dis-
tributed around the house, based on the
size of house. This greatly improves the
thermal response of the back-up heating
system should it be required. The venti-
lation system is designed to meet the re-
quirements of the draft Part F of the Irish
building regulations.
A unique feature is that during periods
of higher levels of solar radiation, more
fresh air is brought in by way of the HRV
system to ventilate the house to a higher
level than required by the building regu-
lations to maintain freshness within the
house. This can be done as it is using the
solar array to its optimum level and the
house is being either heated or ventilated
at a zero energy penalty.
A higher percentage of the domestic hot
water will be achieved by this system than
with the smaller array on the normal passive
house because there is twice the area of
solar collector. The NuTech passive solar
house is designed to achieve an A2 rating
on SEI’s BER scale.
A significant point with the NuTech passive
solar house is that SEI’s DEAP calculation
method allows the designer to take into account
the energy from the solar array that is being
transferred to reduce the energy demand
for space heating. This improves the BER
rating of the NuTech passive solar house
and aids the achievement of an A2 rating.
A comparison of the two concepts
In carrying out a comparison of a typical
200m2
house the various parameters were
inputted into the DEAP calculation method
such that both systems should give a
house design with an equal BER rating.
The parameters were as follows:
Both houses are designed to have the same
BER of 46 kWh/m2
/yr and are therefore
achieving an A2 rating. However, the NuTech
passive solar house offers a number of
cost and performance benefits. The ex-
ternal wall will be considerably cheaper
to build and the windows being double
as opposed to triple-glazed may be far
cheaper. The back-up heating can deliver
far more energy by way of the integrated
heating system and can therefore cope
with a far faster thermal response. More
fresh air is delivered when there is more
solar radiation available thereby giving
increased fresh air at no energy penalty.
It is suggested also that rather than having
very large areas of south-facing glazing
which may cause problems of over-heat-
ing in summer, that a larger area of solar
collector can achieve the same result without
the over-heating problem.
Conclusions
The Passivhaus Institut design and the NuTech
passive solar house both offer systems that
will perform very well in Ireland. Both
systems will deliver high levels of com-
fort at exceptionally low running costs. It
is proposed that the NuTech passive solar
house will achieve the same BER rating at
a lower capital cost.
1SEI’s Renewable Energy Information Office has
published Passive homes: Guidelines for the design
and construction of passive house dwellings in
Ireland, including specific U-value requirements
for building Irish passive housing. Visit
http://tinyurl.com/passivhausireland to access
a PDF of the document.
NuTech passive solar house passive house standard
DEAP calculation 46 kWh/m2/yr 46 kWh/m2/yr
Indicative BER A2 A2
Floor area 200 m2 200m2
Wall (U-value) 0.16 W/m2K 0.13 W/m2K
Windows & doors 1.20 W/m2K 0.80 W/m2K
Ground floor 0.12 W/m2K 0.12 W/m2K
Roof 0.14 W/m2K 0.14 W/m2K
Thermal bridging Equal Equal
Solar array 6m2 Thermomax delivering 3m2 Thermomax to domestic
energy to domestic hot water hot water only
and to the integrated HRV and
heating system
(below) In the NuTech system, the energy from the solar panels is integrated into the HRV
system (top) circulating warm air to all rooms within the house even in dull weather (mid-
dle) a NuTech/KTF passive solar house under construction at a Fingal County Council so-
cial housing scheme at Oldtown

Contenu connexe

Tendances

Residential Case Studies of Passive Strategies
Residential Case Studies of Passive StrategiesResidential Case Studies of Passive Strategies
Residential Case Studies of Passive Strategies
aiahouston
 

Tendances (20)

Net Zero Energy in Very Cold Climates by Peter Amerongen
Net Zero Energy in Very Cold Climates by Peter AmerongenNet Zero Energy in Very Cold Climates by Peter Amerongen
Net Zero Energy in Very Cold Climates by Peter Amerongen
 
PASSIVE HOUSE POSTER
PASSIVE HOUSE POSTERPASSIVE HOUSE POSTER
PASSIVE HOUSE POSTER
 
Minneapolis Passive House and Zero Energy Ready Home Report Presentation
Minneapolis Passive House and Zero Energy Ready Home Report PresentationMinneapolis Passive House and Zero Energy Ready Home Report Presentation
Minneapolis Passive House and Zero Energy Ready Home Report Presentation
 
Swedish Passivhaus Conference Laholm 2019
Swedish Passivhaus Conference Laholm 2019Swedish Passivhaus Conference Laholm 2019
Swedish Passivhaus Conference Laholm 2019
 
Is Passivhaus a step too far? South Pacific Passive House Conference Auckland...
Is Passivhaus a step too far? South Pacific Passive House Conference Auckland...Is Passivhaus a step too far? South Pacific Passive House Conference Auckland...
Is Passivhaus a step too far? South Pacific Passive House Conference Auckland...
 
CEE Passive House Lecture (April 23, 2020)
CEE Passive House Lecture (April 23, 2020)CEE Passive House Lecture (April 23, 2020)
CEE Passive House Lecture (April 23, 2020)
 
Passive House In Depth for Professionals
Passive House In Depth for ProfessionalsPassive House In Depth for Professionals
Passive House In Depth for Professionals
 
Passivhaus Designing for heating load 25th Passivhaus Conference
Passivhaus Designing for heating load 25th Passivhaus ConferencePassivhaus Designing for heating load 25th Passivhaus Conference
Passivhaus Designing for heating load 25th Passivhaus Conference
 
2013 University of Minnesota Passive House Lecture
2013 University of Minnesota Passive House Lecture2013 University of Minnesota Passive House Lecture
2013 University of Minnesota Passive House Lecture
 
Building an even better Passivhaus School
Building an even better Passivhaus SchoolBuilding an even better Passivhaus School
Building an even better Passivhaus School
 
MinnePHit House Case Study
MinnePHit House Case StudyMinnePHit House Case Study
MinnePHit House Case Study
 
Experience of air to water heat pumps
Experience of air to water heat pumpsExperience of air to water heat pumps
Experience of air to water heat pumps
 
Gas Networks Ireland Technical Presentations- Part L
Gas Networks Ireland Technical Presentations- Part LGas Networks Ireland Technical Presentations- Part L
Gas Networks Ireland Technical Presentations- Part L
 
Green by Design Session
Green by Design SessionGreen by Design Session
Green by Design Session
 
Residential Case Studies of Passive Strategies
Residential Case Studies of Passive StrategiesResidential Case Studies of Passive Strategies
Residential Case Studies of Passive Strategies
 
Passive House: concept, applications, market
Passive House: concept, applications, marketPassive House: concept, applications, market
Passive House: concept, applications, market
 
24th Street Passive House Projects
24th Street Passive House Projects24th Street Passive House Projects
24th Street Passive House Projects
 
George beeler zero energy homes
George beeler zero energy homesGeorge beeler zero energy homes
George beeler zero energy homes
 
St Thomas The Apostle, Elson Faculty Application
St Thomas The Apostle, Elson Faculty ApplicationSt Thomas The Apostle, Elson Faculty Application
St Thomas The Apostle, Elson Faculty Application
 
First Passive House Retrofit in a Cold Climate: The MinnePHit House
First Passive House Retrofit in a Cold Climate: The MinnePHit HouseFirst Passive House Retrofit in a Cold Climate: The MinnePHit House
First Passive House Retrofit in a Cold Climate: The MinnePHit House
 

En vedette

Isover - Multicomfort House - FR
Isover - Multicomfort House - FRIsover - Multicomfort House - FR
Isover - Multicomfort House - FR
Architectura
 

En vedette (7)

Isover - Multicomfort House - FR
Isover - Multicomfort House - FRIsover - Multicomfort House - FR
Isover - Multicomfort House - FR
 
Présentation Cost House MEA
Présentation Cost House MEAPrésentation Cost House MEA
Présentation Cost House MEA
 
Icd2014 ecoconstruction pays nordiques
Icd2014 ecoconstruction   pays nordiquesIcd2014 ecoconstruction   pays nordiques
Icd2014 ecoconstruction pays nordiques
 
Icd2014 solutions transport & logistique
Icd2014 solutions transport & logistiqueIcd2014 solutions transport & logistique
Icd2014 solutions transport & logistique
 
Multi-agent Control of Thermal Systems in Buildings
Multi-agent Control of Thermal Systems in BuildingsMulti-agent Control of Thermal Systems in Buildings
Multi-agent Control of Thermal Systems in Buildings
 
Pasquill - Multi Comfort
Pasquill - Multi ComfortPasquill - Multi Comfort
Pasquill - Multi Comfort
 
SEO pour les développeurs - eléments essentiels et bonnes pratiques
SEO pour les développeurs - eléments essentiels et bonnes pratiquesSEO pour les développeurs - eléments essentiels et bonnes pratiques
SEO pour les développeurs - eléments essentiels et bonnes pratiques
 

Similaire à Bill Quigley Passive solar house CI

The passive house_2009_Arny Arnadottir_1
The passive house_2009_Arny Arnadottir_1The passive house_2009_Arny Arnadottir_1
The passive house_2009_Arny Arnadottir_1
Arny Arnadottir
 
Energy Assignments
Energy AssignmentsEnergy Assignments
Energy Assignments
Eamon Healy
 
Passive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and PlannersPassive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and Planners
Leonardo ENERGY
 
111127 Penwith Ha Heat Pod Project V3
111127 Penwith Ha Heat Pod Project V3111127 Penwith Ha Heat Pod Project V3
111127 Penwith Ha Heat Pod Project V3
DenysStephens
 
Guide to Building an Energy Efficient Home
Guide to Building an Energy Efficient Home Guide to Building an Energy Efficient Home
Guide to Building an Energy Efficient Home
mrconroy
 
Passive construction presentation dc
Passive construction presentation dcPassive construction presentation dc
Passive construction presentation dc
CKMCforstudents
 
Residential Energy Audit Report
Residential Energy Audit ReportResidential Energy Audit Report
Residential Energy Audit Report
Michael Clarke
 
Salford Energy House project brochure
Salford Energy House project brochureSalford Energy House project brochure
Salford Energy House project brochure
Mark Weaver
 
[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A
[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A
[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A
GBC Finland
 

Similaire à Bill Quigley Passive solar house CI (20)

Presentation Itfma Seminar 21 May08
Presentation Itfma Seminar 21 May08Presentation Itfma Seminar 21 May08
Presentation Itfma Seminar 21 May08
 
Defining the Nearly Zero Energy Building – Best practice brochure for municip...
Defining the Nearly Zero Energy Building – Best practice brochure for municip...Defining the Nearly Zero Energy Building – Best practice brochure for municip...
Defining the Nearly Zero Energy Building – Best practice brochure for municip...
 
The passive house_2009_Arny Arnadottir_1
The passive house_2009_Arny Arnadottir_1The passive house_2009_Arny Arnadottir_1
The passive house_2009_Arny Arnadottir_1
 
Energy Assignments
Energy AssignmentsEnergy Assignments
Energy Assignments
 
New Kid on the Block: Passive House Comes into Pittsburgh's Neighborhood
New Kid on the Block: Passive House Comes into Pittsburgh's NeighborhoodNew Kid on the Block: Passive House Comes into Pittsburgh's Neighborhood
New Kid on the Block: Passive House Comes into Pittsburgh's Neighborhood
 
Cool Roofing and Building enveloping
Cool Roofing and Building envelopingCool Roofing and Building enveloping
Cool Roofing and Building enveloping
 
Infill Construction Guide
Infill Construction GuideInfill Construction Guide
Infill Construction Guide
 
Passive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and PlannersPassive Home Training Module for Architects and Planners
Passive Home Training Module for Architects and Planners
 
Free cooling guide 02 2013_46512
Free cooling guide 02 2013_46512Free cooling guide 02 2013_46512
Free cooling guide 02 2013_46512
 
111127 Penwith Ha Heat Pod Project V3
111127 Penwith Ha Heat Pod Project V3111127 Penwith Ha Heat Pod Project V3
111127 Penwith Ha Heat Pod Project V3
 
Guide to Building an Energy Efficient Home
Guide to Building an Energy Efficient Home Guide to Building an Energy Efficient Home
Guide to Building an Energy Efficient Home
 
Passive construction presentation dc
Passive construction presentation dcPassive construction presentation dc
Passive construction presentation dc
 
Residential Energy Audit Report
Residential Energy Audit ReportResidential Energy Audit Report
Residential Energy Audit Report
 
N1 presentation1
N1 presentation1N1 presentation1
N1 presentation1
 
Launch slides part 1
Launch slides part 1Launch slides part 1
Launch slides part 1
 
Salford Energy House project brochure
Salford Energy House project brochureSalford Energy House project brochure
Salford Energy House project brochure
 
Conference paper: Passive House for Medium Density Housing in NZ (2018)
Conference paper: Passive House for Medium Density Housing in NZ (2018)Conference paper: Passive House for Medium Density Housing in NZ (2018)
Conference paper: Passive House for Medium Density Housing in NZ (2018)
 
2016 - Building Simulation Best of.pptx
2016 - Building Simulation Best of.pptx2016 - Building Simulation Best of.pptx
2016 - Building Simulation Best of.pptx
 
SUSTAINABLE HOUSE DESIGN
SUSTAINABLE HOUSE DESIGNSUSTAINABLE HOUSE DESIGN
SUSTAINABLE HOUSE DESIGN
 
[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A
[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A
[Metropolia Student Project Seminar 24.5.] Zero Energy Buildings, Group A
 

Plus de NuTech Renewables Ltd

Plus de NuTech Renewables Ltd (10)

Gni case study solar enhanced units2 (1) final - sep15
Gni case study solar enhanced units2 (1)   final - sep15Gni case study solar enhanced units2 (1)   final - sep15
Gni case study solar enhanced units2 (1) final - sep15
 
Social-Climber-Construct-Ireland[1]
Social-Climber-Construct-Ireland[1]Social-Climber-Construct-Ireland[1]
Social-Climber-Construct-Ireland[1]
 
HollowVictory_ci I5v4
HollowVictory_ci I5v4HollowVictory_ci I5v4
HollowVictory_ci I5v4
 
CI Article - Knockananna (High & Mighty)
CI Article - Knockananna (High & Mighty)CI Article - Knockananna (High & Mighty)
CI Article - Knockananna (High & Mighty)
 
Nibe F2300 and F2026 Air/ Water Heat Pump Range
Nibe F2300 and F2026 Air/ Water Heat Pump RangeNibe F2300 and F2026 Air/ Water Heat Pump Range
Nibe F2300 and F2026 Air/ Water Heat Pump Range
 
Bvp en (2)
Bvp en (2)Bvp en (2)
Bvp en (2)
 
Sego presentation
Sego presentationSego presentation
Sego presentation
 
Heat recovery Ventilation on Low Carbon Housing
Heat recovery Ventilation on Low Carbon HousingHeat recovery Ventilation on Low Carbon Housing
Heat recovery Ventilation on Low Carbon Housing
 
Energy Efficiency In Irish Office Buildings
Energy Efficiency In Irish Office BuildingsEnergy Efficiency In Irish Office Buildings
Energy Efficiency In Irish Office Buildings
 
Actionrenewablespresentation
ActionrenewablespresentationActionrenewablespresentation
Actionrenewablespresentation
 

Bill Quigley Passive solar house CI

  • 1. Passive housing and the concept of the passive solar house have been around for many years. In Ireland we have many examples of what was known as the passive solar house. It was quite differ- ent to the Passivhaus concept developed and made successful by Wolfgang Feist and the Passivhaus Institut in Germany. The passive solar house in Ireland The passive solar house, particularly in Ireland, did not feature the attention to U-value, air-tightness and cold bridging that is now prevalent in low energy housing. There were several reasons for this. We had not developed the methods of build- ing which were readily and economically available to achieve very low U-values in practice. Some wall constructions were designed to give low U-values but in real- ity did not do so in practice due to site construction problems. Similarly, triple- glazed windows were not economically available through Irish suppliers. It was found difficult to build houses to levels Passivhaus or passive solar house? A PASSIVE SOLAR HOUSE CONCEPT DESIGNED FOR IRELAND Few concepts in sustainable design have caught on like the passive house. Since the con- struction of the first passive house in Germany in 1990, an estimated 15 to 20,000 houses have been built to what is arguably the world’s leading low energy building standard. Draw- ing from his experience in sustainable building since the early 1980s, Bill Quigley of NuTech Renewables posits an alternative approach.
  • 2. CI 71 of air-tightness that were deemed neces- sary for low energy housing, and elimi- nating thermal bridging was difficult given the methods of construction and the methods of analysis available at the time. It’s fair to say that the Irish construction indus- try simply was not ready to be forced into the highly specialised techniques to achieve the U-values and air-tightness re- quired and also, and probably most im- portantly, there simply was not the will to deliver a near ‘zero-energy’ house. This gave rise to an extraordinary situa- tion, where the ‘low energy house’ in practice could cost considerably more to run than the actual design amount as is illustrated in figure 1. If the actual heat losses are doubled – which could well be the case because of poorly installed insulation, lack of air-tightness and serious thermal bridging – then the running costs tripled over the design value as the amount of solar gain remained approximately the same. With this knowledge and with the growing number of architects and engineers interested in this area of low energy house technol- ogy, a number of examples were built. Probably the first serious example of a passive solar house in Ireland was the Garristown house in County Dublin, built between 1979 and 1980. The concept design was by the well known engineer and special- ist in thermodynamics John Cash, for whom the house was actually being built. Dun- can Stewart was the architect and other colleagues of John and Duncan in DIT were also involved in various aspects of the house design. Huge efforts were made to ensure that this house achieved its de- sign values and indeed it was such a suc- cess that it sparked considerable interest in this area. As can be seen from the photo this reasonably well insulated house fea- tured a massive solar wall of some 110 m2 . Another example of a passive solar house built a little later than the Garristown house was the Knocklyon solar house, which was built and monitored between 1983 and 1989. This house featured an early version of a solar heating and ventilation system which eventually evolved into NuTech’s Sunwarm system. This early system had 40m2 (gross) of air solar col- lectors. In reality this was a passive solar house with an active solar feature. The collector array fed energy into the heat- ing and ventilating system and into the domestic hot water system. The wall in- sulation in this house – an early version of bonded bead – proved troublesome and had to be replaced by blown fibre- glass. Difficulties were also experienced in attaining a high degree of air-tightness. Many different systems were tried and tested in this house including air solar collectors, phase change material heat storage and solar assisted heat pump technology, to name a few. A huge amount of infor- mation was gathered by way of the data monitoring system, the results of which were reported to the energy directorate of the European Commission. The Knocklyon project in particular led the way to a simplified passive solar house concept developed by Mark Forkin and I at NuTech Renewables. This concept can achieve the same results as a more ex- pensive-to-build passive house. Details of this system together with a compari- son will be given later in this article.  Figure 1: effects on energy usage with increased heat loss characteristic (above) Ireland’s first example of a passive solar house in Garristown, County Dublin, fea- tured a solar wall of some 110m2 ; (below) the Knocklyon solar house featured a solar heat- ing and ventilation system; (opposite, top) a clay / straw passive house in Tattendorf, Austria; (opposite, bottom) a NuTech designed passive solar house built with KTF’s inno- vative timber frame system
  • 3. CI 73 The passive house concept The passive house concept as put forward by the Passivhaus Institut is a very excit- ing development and is of its time, as the fabric elements and the systems involved are now fully developed and widely available. The basic requirements are: • The house will use not more than 15 kWh/m2 per year of delivered energy for space heating. • The house will have a specific annual heating load of less than 10 W/m2 . This does take into account the heat gains by way of solar gains through the windows and the internal heat gains due to occupancy. Hence, it should be noted that this is a different figure to the energy required to meet the specific heat loss characteristic of a house for a given temperature difference. • The air-tightness of the house will be such that the air infiltration rate will be less than 0.6 air changes per hour at 50 Pa. • Thermal bridging will be reduced to a minimum. • A heat recovery ventilation system is used to supply the necessary air for ventilation. It must have an efficiency of more than 75 per cent. The system will supply at least 0.3 ACH of fresh air. • A solar water heating system should be used. Typically, a 3m2 Evacuated Tube Array with a 300 litre domestic hot water cylinder will suffice. By these means the necessity for a full primary central heating system are negated. It is generally sufficient to add any extra energy by way of energy delivered from an internal wood pellet stove normally placed in the fireplace of the house, or by way of a small heat pump which is extracting energy out of the extracted air which has already gone across the HRV unit. The design of this unit is catered for in the Passive House Planning Package (PHPP) software. PHPP is a most useful and comprehensive tool to aid the designer in arriving at a satisfactory solution based on all of the above points. To use this package will require most designers to undertake a certain amount of training. To date courses are being of- fered by SEI/REIO and by Nicer Training. Typically, to satisfy the above criteria the fabric U-values must be less than or equal to the following1 : The following points should be given careful consideration: • An air infiltration level of less than 0.6 ACH at 50 Pa is very low indeed. It represents an actual infiltration rate at normal pressure of less than 0.03 ACH. It would be our view that with only 0.3 ACH of fresh air being delivered by way of the HRV system, consideration would have to given to the humidity level in the house in winter as it could drop to very low levels indeed – a figure of 35 per cent relative humidity at 20o C. • ThedraftPartFofbuildingregulations call for a fresh air requirement of 0.3 litres of fresh air per second per m2 of floor area. This must be taken into account and supersedes any other requirements as set out in the PHPP. • At this level of air-tightness, great care would be required in the fitting and use of an internal wood pellet stove to ensure that there was no depressurisation in the room it is sited. Also, the stove would have to be room sealed – in other words its combustion air would have to come from outside – as it should in all low energy houses. • The difficulty in achieving this level of air-tightness should not be underestimated. • If the temperature of the house should drop due to non-occupancy in winter, then the power required in the heating system would have to be greater than 1200 W in order that the house would heat-up in a short time as power will be required to overcome the thermal response/thermal mass of the house. Alternatively, homeowners should be told to leave the heating on even when they are away as it will use so little energy in the first place. • To save costs some passive house designers use a direct acting electric heater in the air duct to provide back-up heating. It should be remembered that when this is taken into account in SEI’s DEAP calculation a severe penalty is incurred as the use of electrical energy is multiplied by a factor of 2.7. Very often it can move the rating of the house on the BER scale from being an A2 house to a B2 rating. • Large areas of south-facing and indeed east- and west-facing glazing shouldbegivencarefulconsideration. The possibility of overheating due to solar gains through these windows must be considered and appropriate steps taken. • It is vitally important that the fabric thermal performance levels are achieved in practice. If there is only a 1200 W heater to cater for deficiencies and if the actual heat losses were somewhat higher than the design, then it would be disastrous for the comfort levels experienced by the home owner and the running costs would escalate accordingly. There is no doubt that if all of the criteria are adhered to rigidly then a low energy house will result. Comfort levels will be satisfactory and running costs will be very low. However, it is important that all of the above points are taken into consider- ation by the designer and the builder. The NuTech passive solar house concept The NuTech passive solar house concept is a little different. It was devised originally by Mark Forkin and this author out of the design and systems used in the original passive solar house in Knocklyon. All of the technologies developed have been rigorously tested over the past 20 years. In essence, the U-values arrived at are a little less strict in certain circumstances over the PHI values to ensure cost breaks are achieved and then this is compensated for by way of a larger solar array of evac- uated tubes delivering energy into the HRV system even in cloudy weather (hence the reason for using evacuated tubes over flat plate collectors). The thinking is that as insulation levels get higher and higher it is a clear case of diminishing returns which are, as mentioned, offset by the amount of energy delivered to heating by way of the solar array. NuTech are in full agree- ment that high levels of air-tightness are essential. The reduction in thermal bridging is also vitally important as this has an enormous effect on the overall heat loss characteristic (W/K) of the house. Typically, the NuTech requirements for the fabric U-values must be less than or equal to the following:1 As can be seen there are some essential differences to the typical PHI requirements. The external wall U-value is raised to 0.16 W/m2 K as it can be achieved in tim- ber frame with a reasonably sized stud which then has internal insulation fixed to reduce the effect of thermal bridging. The window U-value is raised to 1.2 W/m2 K as it then allows the use of well designed double glazing rather than the more ex- pensive triple glazing unit. The level of air infiltration has been raised to 1.0 ACH  U-Value (W/m2K) Ground floor 0.12 External wall 0.13 Roof 0.14 Windows and doors 0.80 U-Value (W/m2K) Ground floor 0.12 External wall 0.16 Roof 0.14 Windows and doors 1.20 Infiltration level 1.0 ACH at 50Pa Figure 2: a schematic of the NuTech integrated solar heating and HRV unit in a passive solar house
  • 4. CI 75 at 50 Pa – a difficult but more achievable target which also helps reduce construc- tion costs. Finally the energy from at least a 6m2 evacuated tube solar array is inte- grated into the HRV system, thus solar heated air is being circulated to all rooms within the house even in dull weather. The heat generator, whether it is an internal wood pellet boiler or an air to water heat pump is also integrated into this system. This fully integrated system is controlled by way of the NuTech intelligent renew- able energy system (IRES) controller. As regards thermal bridging, systems have been developed with the timber frame company KTF Ltd., such that the amount of thermal bridging is hugely reduced by way of the insulation systems and partic- ularly by way of details around the win- dows and doors. As mentioned above, this is vitally important. It is worth remembering that if the thermal bridging factor in the DEAP analysis is 0.08 W/m2 K then the U- value for all of the elements is increased by this amount. A wall U-value of 0.16 W/m2 K therefore becomes 0.24 W/m2 K in the overall calculation. It is that serious. Thispassivesolarhousesystemhasmanystrong features. It has reasonably low U-values for all of the fabric items, and is tested to achieve less than 1.0 ACH at 50 Pa. It integrates the energy from the solar array into the HRV system, and similarly integrates energy from the back-up boiler (internal wood pellet or heat pump) into the HRV system. There is also a facility to have filtered re- circulated air within the system thereby allowing 5 kW to 10 kW of heat to be dis- tributed around the house, based on the size of house. This greatly improves the thermal response of the back-up heating system should it be required. The venti- lation system is designed to meet the re- quirements of the draft Part F of the Irish building regulations. A unique feature is that during periods of higher levels of solar radiation, more fresh air is brought in by way of the HRV system to ventilate the house to a higher level than required by the building regu- lations to maintain freshness within the house. This can be done as it is using the solar array to its optimum level and the house is being either heated or ventilated at a zero energy penalty. A higher percentage of the domestic hot water will be achieved by this system than with the smaller array on the normal passive house because there is twice the area of solar collector. The NuTech passive solar house is designed to achieve an A2 rating on SEI’s BER scale. A significant point with the NuTech passive solar house is that SEI’s DEAP calculation method allows the designer to take into account the energy from the solar array that is being transferred to reduce the energy demand for space heating. This improves the BER rating of the NuTech passive solar house and aids the achievement of an A2 rating. A comparison of the two concepts In carrying out a comparison of a typical 200m2 house the various parameters were inputted into the DEAP calculation method such that both systems should give a house design with an equal BER rating. The parameters were as follows: Both houses are designed to have the same BER of 46 kWh/m2 /yr and are therefore achieving an A2 rating. However, the NuTech passive solar house offers a number of cost and performance benefits. The ex- ternal wall will be considerably cheaper to build and the windows being double as opposed to triple-glazed may be far cheaper. The back-up heating can deliver far more energy by way of the integrated heating system and can therefore cope with a far faster thermal response. More fresh air is delivered when there is more solar radiation available thereby giving increased fresh air at no energy penalty. It is suggested also that rather than having very large areas of south-facing glazing which may cause problems of over-heat- ing in summer, that a larger area of solar collector can achieve the same result without the over-heating problem. Conclusions The Passivhaus Institut design and the NuTech passive solar house both offer systems that will perform very well in Ireland. Both systems will deliver high levels of com- fort at exceptionally low running costs. It is proposed that the NuTech passive solar house will achieve the same BER rating at a lower capital cost. 1SEI’s Renewable Energy Information Office has published Passive homes: Guidelines for the design and construction of passive house dwellings in Ireland, including specific U-value requirements for building Irish passive housing. Visit http://tinyurl.com/passivhausireland to access a PDF of the document. NuTech passive solar house passive house standard DEAP calculation 46 kWh/m2/yr 46 kWh/m2/yr Indicative BER A2 A2 Floor area 200 m2 200m2 Wall (U-value) 0.16 W/m2K 0.13 W/m2K Windows & doors 1.20 W/m2K 0.80 W/m2K Ground floor 0.12 W/m2K 0.12 W/m2K Roof 0.14 W/m2K 0.14 W/m2K Thermal bridging Equal Equal Solar array 6m2 Thermomax delivering 3m2 Thermomax to domestic energy to domestic hot water hot water only and to the integrated HRV and heating system (below) In the NuTech system, the energy from the solar panels is integrated into the HRV system (top) circulating warm air to all rooms within the house even in dull weather (mid- dle) a NuTech/KTF passive solar house under construction at a Fingal County Council so- cial housing scheme at Oldtown