1. Hall
1960
3695 4680
UTILITY
SITTING ROOM
Mat Well
ENTRANCE HALL
BATHROOM
BEDROOM BEDROOM
BOOT ROOM
DINING AREA
LIVING AREA
KITCHEN
Proposed 2- storey extension
Remove existing door, build up wall,
insert new full height toughened glazed
window to detail. Make good all works
Remove existing window, build up wall,
insert new corner window with steel beams
over and steel column for support. Make good
all works
4723
2805
2030
3120
1025
2515
3120
Demolish existing sub-standard extension
Break out existing wall and
form new window ope
Block up existing window
Remove part of existing 700mm
solid wall and doorway, Steel
Beam over to specification.
Remove existing wall and window and
install new bi-folding doors with steel
above to form new opening to evening
patio
Install new Velux rooflights to new roof
Open Ceiling to roof of extension
Break open existing wall, remove
patio door and install new bifolding
door system
Large Velux rooflight tunnels,
either side of ridge
Evening Patio
+Open Ceiling to underside of eaves
+2.45m high flat ceiling
HOT-PRESS
WC Area of ground floor extension = 34.66m2
Area of first floor extension = 22.08m2
Total floor area of extension = 56.74m2
15714 3300
3680 1060
800 2080
7600
4826
4330
280
3199
3550
9588
8170
500
2 No. Velux rooflight, either side of ridge
Remove existing door and
replace with Toughened
glass window
Remove existing window, block up
and make good all works
NOTE: All existing windows to be removed and replace
with double/triple glazed 'Low E' Argon filled windows
New full height toughened glazed
window to detail. Make good all works
+2.45m Ceiling Height
+2.45m Ceiling Height
+2.45m Ceiling Height
+2.45m Ceiling Height
+2.45m Ceiling Height
+2.45m Ceiling Height
Break out part of existing
wall, window to form new
entrance hall and stairway
Break open existing wall, insert new door
to access proposed extension
2 No. window opes to be reduced to accomodate
kitchen worktops, new windows 1100mm high
3800
Triple Glazed Argon Filled
Low-E, U-PVC Windows
as per Spec.
Min U-Value 1.4 W/m2K
320mm Cavity Wall
filled with 80mm HD
Insulation (Kooltherm K5
EWB or equal & approved),
to achieve a min U-Value of
0.15 W/m2K.
Sand & Cement Plaster to
act as airtight layer internally.
Concrete Path around New
Extension, to provide level
access to Front Door .
ACO drain to be installed
in front of Door.
Fully Accessible Front
Door with glazed screen.
Velux Window.
Min U0-Value 1.4 W/m2K.
Light Tunnel to kitchen.
Boxed Out in Plasterboard.
Insulation Layer and AirTight
Membrane to continue
around light tunnel to ensure
continuity of both between
ceiling level and window.
New ESB Meter located in
original position
Accessible Guest Bathroom.
Toilet CL located min
400mm from wall.
1200x750mm Clear Space
Stairs to Architect/Client's
Detail. Hardwood Handrail.
15 Steps of Equal Rise
from GF FFL to FF FFL
(Approx 190mm Rise,
220mm Going)
SCALE 1:50 @ A1, 1:100 @ A3
Proposed floor area extension = 34.66m2
5
GROUND FLOOR PLAN
NOTES:
Foundations
Width of foundations to be at
least 3 times width of external
walls, min 1 layer of A393
Mesh.
Ground Floor
75mm Screed on Min.
on 125mm Thick 25N20 Slab
on 100mm Kingspan
Kooltherm Floorboard (or
similar)
on Radon Barrier.
on 50mm sand blinding.
on Min 250mm Hardcore
filling (Clean permeable
granular fill) compacted in
layers of 225mm.
Existing floors to be leveled
and made good. Existing
floor in the proposed kitchen
area to be insulated 100mm
insulation, to be
approved,with 75mm screed
over and made good.
Explore further, as this will
reduce ceiling heights in
dining and living areas or
create steps. Client's
preference is final.
First Floor
225mm x 44mm Timber Floor
Joists at 350mm Centres.
Bridging at 1200mm centres.
12.5mm plasterboard fixed to
the underside of joists and
surface skimmed.
Wall Construction
320mm Cavity Wall, 100mm
block inner leaf, 80mm HD
Insulation (Kooltherm K5
EWB or equal & approved)
fixed securely to inner leaf
over full height of wall, and
100mm coloured render
blockwork outer leaf, to
achieve a min U-Value of
0.15 W/m2K.
Windows:
Aluclad Frames.
Low E Argon Filled.
Win Min U-Value 1.4 W/m2K
Door Min U-Value 1.6 W/mwK
All windows to comply with
Current Building Regulations
TGD Part B re Escape ope - Min
850mm high x 550 wide, Min
800 above floor level.
Max 1100 above floor level.
All rooms to have background
ventilation to the outside.
Pitched Roof Construction:
Tiles to be laid to
Manufacturers's Instructions.
on 55 x 33mm Battens
on Breather Membrane,
On Proprietary Roof Trusses to
spec & manufacturer's design.
Roof Insulated at ceiling Level
with 300 mm Fibre Insulation
between and over joists, to
achieve a
min U-value of U=0.13 W/m2K.
Eaves > Ridge Ventilation.
Solar Panels
To be positioned on the back or
side elevations as required for a
SE/SW orientation.
Thermal - 2.5m long x 2.0m
high - 30 Evacuated Tubes.
PV - 1.6m long x 1 m high.
Granite cills to windows
on front elevation only,
Widows W1,W2,W3,W4,W5,
W6,W7.
Existing chimney stack,
hearth, fireplace and all
associated to be
decommissioned,
demolished and removed.
Make good all works.
Walls, on both side of
existing fireplace, to be set
back in line with each other,
and new wall in place of
chimney breast, to create
one new flushed wall. Make
good all works.
Refer to Detail A, boxing
in of existing random rubble
wall, conc. ring beam, to
create a flushed finished wall
from floor to open ceiling.
Existing alcove to be filled in,
plasterboard, painted etc. to
match exising/proposed wall
Refer to Detail A, boxing
in of existing random rubble
wall, conc. ring beam, to
create a flushed finished wall
from floor to open ceiling. Retain exsiting alvove, open
to floor level, create shelving
throughout. Make good all
works. Doors or open
shelving as per client's spec.
Existing double breasted chimney,
stack, hearth, fireplace and all
associated to be decommissioned,
demolished and removed. Make good
all works.
Investigate ceiling heights on site with
B.Surv.
Remove superficial non-structural
ceiling beams
Remove superficial/decorative,
non-structural, timber ceiling beams
Retain all existing structural beams,
box in with plasterboard. Create flush
finish.
1000mm concrete footpath around
existing dwelling and proposed extension,
as shown.
Ground levels to reduced/built up around existing
dwelling and extension, as required, to create equal
levels throughout. Levels to allow for 150mm high
footpath riser and 150mm single step riser to external doors.
1000mm concrete footpath around
existing dwelling and proposed extension,
as shown.
Ground levels to reduced/built up around existing
dwelling and extension, as required, to create equal
levels throughout. Levels to allow for 150mm high
footpath riser and 150mm single step riser to external doors.
Finished Floor Level
+0.300
Path Level
+0.150
Ground Level
+0.000
Tile finish to Client's Spec.
2no203x133x30kgsteelbeamovertoengineer'sdetail
2no 203x133x30kg steel beam over to engineer's detail
2no 203x133x30kg steel beam over to engineer's detail
Tile finish to Client's Spec.
Tile finish to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Tile finish to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
1no203x133x30kgsteelbeamovertoengineer'sdetail
SVP
AJ
GG
GGGGGG
GG
GG GG GG
AJ
To Soakpit
AJ
To Soakpit
SVP
SVP
MH MH
MH
MH
To New
Wastewater
Treatment System
PublicWatermain
Proposed Boiler House
Extract vents (8 No 9" x 3"
(8000mm2)
Wall vent to match colour of
External render / wall finish.
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
20/05/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS2
TITLE:
TENDER
T-001
1/100
GROUND FLOOR PLAN
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
2. MASTER BEDROOM
Landing
4205
VOID TO ENTRANCE
HALL BELOW
Walk-in
Wardrobe
(linen storage)
En-Suite
Lower existing window ope &
cill level and install new
window
BEDROOM 2
LINEN-PRESS
1488
2no. Velux rooflights
above entrance hall
4911
3280
2191
1850
4899 1350
900
Install new Velux rooflights to existing roof
Install new Velux rooflight to existing roof
Install new Velux rooflight to existing roof
SHOWER ROOM
OFFICE
Existing ceilings on first floor level to be
raised to min. 2.4m high
3449
4558
1909
3114
Elec. Shower
80mm Acoustic Insulation to
existing timber partitions
forming dormer roof
100mm Timber Stud Wall,
with Acoustic Insulation.
Landing
100mm Timber Stud Wall,
with Acoustic Insulation to
form new linen store in
dormer roof.
A
Lower existing window ope &
cill level and install new
window
320mm Cavity Wall
filled with 80mm HD
Insulation (Kooltherm K5
EWB or equal & approved),
to achieve a min U-Value of
0.15 W/m2K.
Sand & Cement Plaster to
act as airtight layer internally.
A
FIRST FLOOR PLAN
B B
6 SCALE 1:50 @ A1, 1:100 @ A3
Proposed floor area extension = 22.08m2
1735
1047
2630
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Wooden Floor finish
to Client's Spec.
Tile finish to Client's Spec.
Tile finish to Client's Spec.
SVP
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
19/05/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS2
TITLE:
TENDER
T-002
1/100
FIRST FLOOR PLAN
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
3. 5920
2423
Large Velux rooflight tunnels,
either side of ridge
Install new Velux rooflights to new roof
Widen ope, lower existing
window cill level and install
new window
Remove existing door, build up wall,
insert new full height toughened glazed
window to detail. Make good all works
Remove existing window, build up wall,
insert new corner window as shown. Make good
all works
Proposed 2- storey extension
1100
Moulded Plinth to
Match Window
Surround.
Coloured Nap
Render as per
Spec
Paving Rising at Max 1:20
slope to provide level
access to front door.
ACO drain to be installed
in front of Door.
Fully Accessible Front
Door with glazed screen.
Refer to Door Schedule.
SCALE 1:50 @ A1, 1:100 @ A3
FRONT ELEVATION
1
W1 W2
W4
W6 W7
W9
W15 W16
W17 W18 W19
D1
5996
2498
2653
4032
Install new Velux rooflights to new roof
2 No. Velux rooflight, either side of ridge
New corner window as shown. Make good
all works
Proposed 2- storey extension
2800
SCALE 1:50 @ A1, 1:100 @ A3
4
SIDE ELEVATION
W9
W10 W11
W21 W22
W23
W20
W1W5
W8
6150
2653
4032
5528
Large Velux rooflight tunnels,
either side of ridge
Remove existing door and
replace with Toughened
glass window
Break open existing wall, remove
patio door and install new bifolding
door system
W12
W13
W25
W24
W27
W11
W26
D3
Remove existing wall and window and
install new bi-folding doors with steel
beam above to form new opening to
evening patioRemove existing window, block up
and make good all works
2 No. Velux rooflight, either side of ridge
Solar Panels to be
positioned on the back or
side elevations as required
for a SE/SW orientation.
Thermal - 2.5m long x 2.0m
high - 30 Evacuated Tubes.
PV - 1.6m long x 1 m high.
See M&E Spec for Exact
Quantities. and Specification
SCALE 1:50 @ A1, 1:100 @ A3
SIDE ELEVATION
3
W14
D2
W3
W28
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
14/05/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS1
TITLE:
TENDER
T-003
1/100
ELEVATIONS
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
4. Trial Hole
T2
T3
T1
p3
P2
P1
7017
2300mm
9000
1000
1000
5231
157097
143871
11398
71627
13792
8434
2814
40720
132360
15216
7959
Location of Public Site Notice
Existing Recessed Entrance to
Dwelling
Existing Dwelling
Existing Garden
Proposed Aswaflow Treatment
System and Percolation Area
supplied and installed as per
Molloy Precast Specifications
Existing mature boundary
Existing mature boundary
Proposed extension
A
A
+98.55
Existing Dwelling
FFL +98.35
FRH +104.27
FFL +98.30
FRH +104.22
+98.15
+98.15
+98.30
+98.20
+98.90
+98.95
+98.90
+99.00
+99.10
+99.00
+99.10
+99.00
Existing Dwelling
Proposed saokaway
Existing saokaway
Existing septic tank to
be decomissioned & removed
from site
7714
Existing mains waterline
Existing septic tan
area
Existing septic tank & percolation
area
Flow of water
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
20/05/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, BROWNSTOWN, CO. KILDARE.
PROJECT
TITLE:
TENDER
T-004
1/500
SITE LAYOUT PLAN
JAMES & CARMEL O'BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
Extension to side of dwelling, minor
alterations to elevations, installation of a new
wastewater treatment system
5. Trial Hole
T2
T3
T1
p3
P2
P1
7017
2300mm
9000
1000
1000
5231
157097
63102
143871
11398
71627
13792
8434
2814
40720
132360
15216
7959
Location of Public Site Notice
Existing Recessed Entrance to
Dwelling
Existing Dwelling
Existing Garden
Aswaflow Treatment System and Percolation
Area supplied and installed as per Molloy
Precast Specifications
Existing mature
boundary
Existing mature
boundary
Existing mature
boundary
Existing mature boundary
Site under
application
outlined in red
Proposed
extension
A
A
+98.55
Proposed Extension
FFL +98.35
FRH +104.27
FFL +98.30
FRH +104.22
+98.15
+98.15
+98.30
+98.20
+98.90
+98.95
+98.90
+99.00 +99.10
+99.00
+99.10
+99.00
+99.10
+99.30
+99.40
+99.40
+99.60
+99.90
+99.60
+100.10
+99.70
+100.00
Existing
Neighbouring
Dwellings
Proposed saokaway Existing saokaway
Existing septic tank
to be decommissioned
and removed
7714
Existing mains waterline
Existing septic tank & percolation area
Existing septic tank & percolation area
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
20/05/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, BROWNSTOWN, CO. KILDARE.
PROJECT
TITLE:
TENDER
T-005
1/1000
SITE LAYOUT PLAN
JAMES & CARMEL O'BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
Extension to side of dwelling, minor
alterations to elevations, installation of a new
wastewater treatment system
6. ROAD
gl98.100
gl98.900
Proposed Extension
F.R.H. = 81.901
1/200 fall
Inlet pipe:
I.L. 97.685
Site Boundary
Aswaflow Treatment System Proposed percolation area
gl97.900
gl98.150
gl98.200
gl98.450
Outlet Pipe:
I.L. 74.875
Percolation pipe: I.L. 97.784
300mm topsoil on Geotextile membrane,
on 150mm subsoil on,
100mm dia. percolation pipe, on
300mm subsoil
Longitudinal Site Section
Scale 1:250
Proposed Extension
F.F.L.=75.75
Existing Ground Level 75.60
2450
2300
1800
1725
1/100 fall 1/100 fall
550
300
2188
Base of percolation trench
Base of trial hole, no watertable encountered
3676
2339
3073
950
Discharge hose
Aerator
Siphon hose
Input
Outlet
2300mm
AJ's to be
installed by others.
Grade pipes only at 1:200
Protected flushing valve &
inspection cambers
AJ's to be
installed by others.
Treatment System & Percolation Area - Plan
Scale 1:100
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
20/05/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, BROWNSTOWN, CO. KILDARE.
PROJECT
TITLE:
TENDER
T-006
1/500
LONGITUDINAL SITE SECTION A-A
PERCOLATION DETAILS
JAMES & CARMEL O'BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
Extension to side of dwelling, minor
alterations to elevations, installation of a new
wastewater treatment system
Typical Section through Percolation Area
Scale nts
Section through Treatment System
Scale nts
7. SCALE 1:50 @ A1, 1:100 @ A3
Proposed floor area extension = 34.66m2
5
FOUNDATION PLAN
Radon:
Max distance to radon sump
of 15m. Max area 250m2.
Cross Vent Gaps to be left in
rising walls to allow Radon
Gas to reach the Radon
Sump. Gap to be 12,500
mm2 per metre run of wall
(eg a quarter of a block in
each 4 block length.
75mm Screed on Min.
on 125mm Thick 25N20 Slab
on 100mm Kingspan Kooltherm
Floorboard (or similar)
on Radon Barrier.
on 50mm sand blinding.
on Min 250mm Hardcore filling
(Clean permeable granular fill)
compacted in layers of 225mm.
Radon Sump Proprietary
Collection Box for max 250sqm
floor area (max distance 15m).
terminates outside and is
capped.
320mm Cavity Wall on 960 x
300mm Reinforced Concrete
Foundations with min 1 layer of
A393 Mesh.
See Foundation Detail 1.
Cross Vent Gaps to be left in
rising walls to allow Radon Gas
to reach the Radon Sump as
per Building Regulation
Requirements. Gap to be
12,500 mm2 per metre run of
wall (eg a quarter of a block in
each 4 block length.
100mm Blockwork Wall on
700mm x 300mm Reinforced
Concrete Foundations with min
1 layer of A393 Mesh. See
Foundation Detail 2.
215mm Blockwork Wall on
815mm x 300mm Reinforced
Concrete Foundations with min
1 layer of A393 Mesh. See
Foundation Detail 3.
.
215mm Blockwork Wall on
815mm x 300mm Reinforced
Concrete Foundations with min
1 layer of A393 Mesh. See
Foundation Detail 3.
.
Radon:
Max distance to radon sump
of 15m. Max area 250m2.
Cross Vent Gaps to be left in
rising walls to allow Radon
Gas to reach the Radon
Sump. Gap to be 12,500
mm2 per metre run of wall
(eg a quarter of a block in
each 4 block length.
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
06/06/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS1
TITLE:
TENDER
T-007
1/100
FOUNDATION PLAN
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
8. 1065
300
980180
75mm Screed on Min. on
125mm Thick 25N20 Subfloor Slab
All Services Laid Prior To Pouring & Power
Floated To Smooth Level Finish
S&C Screed is Airtight Layer - to be fully sealed
and taped to wall prior to S&C plastering.
165mmCavity Wall filled with 120mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K.
300x 1050mm Reinforced Concrete Foundation
below 350mm Cavity Wall
25N20 Concrete, with min 1 Layer of A393
Mesh.
25mm High Density Vertical Insulation
separating the warm concrete slab from the
structural wall. Lightweight Concrete Blocks to
be used where the insulation layer meets the
wall.
Min. 120mm HD Floor Insulation - K3
Kooltherm Floorboard or equal and approved.
1200 Gauge D.P.M Laid to Manufacturers
Instructions.
Proprietary Radon Barrier, Continuous with all
joints lapped and sealed, and with the
appropriate number of sumps and outlets.
Foundation Detail 1
SCALE 1:10 @ A1, 1:20 @ A3
1
Min 50mm Sand Blinding.
Min 250mm Hardcore Filling (Clean graded
crushed stone) Compacted in Layers of 225mm.
Radon Pipe 100mm pipe to sump
Pipe Terminates outside and is capped.
All penetrations of radon layer sealed with
resisting sealing tape.
Fountation Depth and Hardcore
Depth vary due to sloping site.
Refer to Long Section, T03
Drawing 2 for more info.
Formation Level -1200mm
300
75mm Screed on Min. on
125mm Thick 25N20 Subfloor Slab
All Services Laid Prior To Pouring & Power
Floated To Smooth Level Finish
300x 700mm Reinforced Concrete Foundation
below Single Leaf Blockwork Wall.
25N20 Concrete, with min 1 Layer of A393
Mesh.
25mm High Density Vertical Insulation
separating the warm concrete slab from the
structural wall.
Min. 120mm HD Floor Insulation - K3
Kooltherm Floorboard or equal and approved.
1200 Gauge D.P.M Laid to Manufacturers
Instructions.
Proprietary Radon Barrier, Continuous with all
joints lapped and sealed, and with the
appropriate number of sumps and outlets.
Min 35mm Sand Blinding.
Min 250mm Hardcore Filling (Clean graded
crushed stone) Compacted in Layers of
225mm.
700
25012012575
Foundation Detail 2
SCALE 1:10 @ A1, 1:20 @ A3
2
495
Formation Level -1200mm
Lightweight Concrete Blocks to be used where
the insulation layer meets the wall.
300
75mm Screed on Min. on
125mm Thick 25N20 Subfloor Slab
All Services Laid Prior To Pouring & Power
Floated To Smooth Level Finish
300x 815mm Reinforced Concrete Foundation
below 215mm Blockwork Wall.
25N20 Concrete, with min 1 Layer of A393
Mesh.
25mm High Density Vertical Insulation
separating the warm concrete slab from the
structural wall. Lightweight Concrete Blocks to
be used where the insulation layer meets the
wall.
Min. 120mm HD Floor Insulation - K3
Kooltherm Floorboard or equal and approved.
1200 Gauge D.P.M Laid to Manufacturers
Instructions.
Proprietary Radon Barrier, Continuous with all
joints lapped and sealed, and with the
appropriate number of sumps and outlets.
Min 35mm Sand Blinding.
Min 250mm Hardcore Filling (Clean graded
crushed stone) Compacted in Layers of
225mm.
815
25012012575
Foundation Detail 3
SCALE 1:10 @ A1, 1:20 @ A3
3
495
240
Formation Level -1200mm
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
04/06/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS2
TITLE:
TENDER
T-D-001
As Shown
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
FOUNDATION AND FLOOR DETAILS
ACCEPTABLE CONSTRUCTION DETAILS
Sign off required to ensure Thermal Bridging Value
9. 165mmCavity Wall filled with 120mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K. Insulation to be secured firmly
against the innter leaf of the cavity.
225mm x 44mm Timber Joists (C16) at
350mm Centres, supported on wall hangers.
To take floor loadings as noted in
Specification.
Allow for min 12mm Carpet
on 18mm Plywood.
Thicknesses as noted in Specification.
12.5mm Proprietary Fire Grade Plasterboard
with joints taped and filled and backed by
timber with Skim Finish to Ceilings, as noted in
Specification.
Airtight layer must continue past intermediate
floor, either through continuous S&C render
layer or through installation of airtight
membrane taped to primed blockwork prior to
fitting joist hangers.
Acoustic Insulation to be fitted between Joists
to reduce sound transfer between rooms..
165mmCavity Wall filled with 120mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K. Insulation to be secured firmly
against the innter leaf of the cavity.
75mm Screed to first floor.
All services to be laid in screed.
Carpet on Substrate.
Thicknesses as noted in Specification.
50mm Timber Lats to be fixed to underside of
concrete floor to provide zone for services.
12.5mm Plasterboard with Skim Finish to
Ceilings, as noted in Specification.
Airtight layer must continue past intermediate
floor, either through continuous S&C render
layer or through installation of airtight
membrane taped to primed blockwork prior to
installing the concrete slab.
85mm Wide Reinforced Concrete Slab with
A142 Mesh, on Floor Hangers.
To take floor loadings as noted in
Specification.
First Floor Detail 1
SCALE 1:10 @ A1, 1:20 @ A3
1
First Floor Detail 2
SCALE 1:10 @ A1, 1:20 @ A3
2
INTERMEDIATE FLOOR DETAILS
ACCEPTABLE CONSTRUCTION DETAILS
Sign off required to ensure Thermal Bridging Value
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
04/06/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS
TITLE:
TENDER
T-D-002
As Shown
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
10. 165mmCavity Wall filled with 120mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K. Insulation to be secured firmly
against the innter leaf of the cavity.
Timber Stud Partition. 100mm x 44mm
Timber Joists (C14) at 400mm Centres.
12.5mm Proprietary Fire Grade Plasterboard
with joints taped and filled and backed by
timber with Skim Finish to Ceilings, as noted in
Specification.
Acoustic Insulation to be fitted between Studs
to reduce sound transfer between rooms..
165mmCavity Wall filled with 120mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K. Insulation to be secured firmly
against the innter leaf of the cavity.
100mm Blockwork Wall, with Sand and
Cement Render on Both Sides to form airtight
layer.
12.5mm Plasterboard to both sides.
Moisture Resistant Plasterboard to be used in
wet rooms, eg bathrooms, ensuites etc.
165mmCavity Wall filled with 120mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K. Insulation to be secured firmly
against the innter leaf of the cavity.
215mm Blockwork Separating Wall to Semi-D,
with Sand and Cement Render on Both Sides
to form airtight layer.
15mm Firmacell Boards at Party Wall for
Additional Sound Insulation.
Ensure Insulation is firmly secured against the
inner leaf of cavity wall, as per manufacturers
instructions.
Proprietary Cavity Closer between houses, to
suit width of the cavity (165mm), to be fitted to
manufacturers instructions.
Ensure Insulation continues across the
abutment zone, and is firmly secured against
the inner leaf of cavity wall, as per
manufacturers instructions.
All penetrations through the air tight layer to
be full sealed.
All penetrations through the air tight layer to
be full sealed.
External Wall to be Sand and Cement
Rendered before fixing Stud Partitions to
ensure continuity of air tight layer. All
penetrations through the air tight layer to be
full sealed.
Wall Junction Detail 1
SCALE 1:10 @ A1, 1:20 @ A3
1
Wall Junction Detail 2
SCALE 1:10 @ A1, 1:20 @ A3
2
Wall Junction Detail 3
SCALE 1:10 @ A1, 1:20 @ A3
3
Where fire-rating is required for
compartmentation in Semi-D (See Drawings),
Standard Blockwork should suffice.
Ensure all penetrations are fully sealed.
Where fire-rating is required to partitions for
compartmentation in Semi-D, (see drawings)
Ensure 12.5mm Plasterboard with all joints
taped and filled, on either side of Timber
Stud Partition (44mm Timber Studs at
400mm Centres.)
WALL TYPES AND JUNCTIONS
INTERMEDIATE FLOOR DETAILS
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
04/06/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS
TITLE:
TENDER
T-D-003
As Shown
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
11. 2 Coats Sand & Cement Plaster
With Napped Finish.
Wall Ties - min 4.9 per sq m.
as noted in Specification
100mm Block Inner Leaf
Steelite Lintel to fully close cavity
320mm Cavity to include 80mm Kooltherm
K5 EWB (or equal and approved)
100mm Block Outer Leaf
Triple Glazed Low-e, Argon Filled Window.
Min U-Value 1.4W/m2K.
Fitted in the Line of the Insulation.
Stepped DPC
Weathered and Throated Cill
on DPC.
Hardwood Window Board
Carefully Fitted HD Insulation to
minimize thermal bridges. Thermal
resistance through the cavity
closer of not less than 0.45
m2K/W.
Wall Ties - min 4 per sq m.
As noted in Specification
100mm Block Inner Leaf
100mm Brick Outer Leaf (where
noted on elevations)
Triple Glazed Low-e, Argon Filled Window.
Min U-Value 1.4W/m2K.
Fitted in the Line of the Insulation.
Stepped DPC
Weathered and Throated Cill
on DPC.
Hardwood Window Board
Carefully Fitted HD Insulation to
minimize thermal bridges.
Moulded Window Surround / Lintel
Reinforced Precast Concrete Lintel
120mm Cavity to include 80mm Kooltherm
K5 EWB (or equal and approved)
Window Detail 1
SCALE 1:10 @ A1, 1:20 @ A3
1
Window Detail 3
SCALE 1:10 @ A1, 1:20 @ A3
3
Proprietary Cavity Closer to
ensure compliance with fire
regulations.
Insulation tightly fitted to close cavity
To eusure the cavity is fully closed,
Plasterboartd to be tightly fitted to the
underside of the lintel and tight against the
window frame, with skim coat plaster finish.
Triple Glazed Low-e, Argon Filled Window.
Min U-Value 1.4W/m2K.
Fitted in the Line of the Insulation.
Airtight Membrane to extend from blockwork
wall (where not S&C rendered), to be sealed
to Window Frame with Air Tight Tape.
Proprietary Cavity Closer or Block of Insulation
to insure the insulation layer remains
continuous between the wall insulation and the
window and ensure fully sealed for fire regs.
Min 150mm Wide Vertical DPC to be installed
against outer leaf and firmly fixed in position.
Triple Glazed Low-e, Argon Filled Window.
Min U-Value 1.4W/m2K.
Fitted in the Line of the Insulation.
Airtight Membrane to extend from blockwork
wall (where not S&C rendered), to be sealed
to Window Frame with Air Tight Tape.
Proprietary Cavity Closer or Block of Insulation
to insure the insulation layer remains
continuous between the wall insulation and the
window and to ensure fully sealed for fire regs.
Min 150mm Wide Vertical DPC to be installed
against outer leaf and firmly fixed in position.
Moulded Window Surround to be provided
where indicated on elevations.
Window Detail 2
SCALE 1:10 @ A1, 1:20 @ A3
2
Window Detail 4
SCALE 1:10 @ A1, 1:20 @ A3
4
100mm Block Inner Leaf
100mm Brick Outer Leaf (where
noted on elevations)
New Triple Glazed Door
Min U-Value 1.3W/m2K.
Fitted in the Line of the Insulation.
Stepped DPC
Moulded Window Surround / Lintel
Reinforced Precast Concrete Lintel
120mm Cavity to include 80mm Kooltherm
K5 EWB (or equal and approved)
Wall Ties - min 4 per sq m.
As noted in Specification
75mm Screed on Min. on
125mm Thick 25N20 Subfloor Slab
All Services Laid Prior To Pouring & Power
Floated To Smooth Level Finish
S&C Screed is Airtight Layer - to be fully sealed
and taped to wall prior to S&C plastering.
25mm High Density Vertical Insulation
separating the warm concrete slab from the
structural wall. Lightweight Concrete Blocks to
be used where the insulation layer meets the
wall.
Min. 120mm HD Floor Insulation - K3
Kooltherm Floorboard or equal and approved.
1200 Gauge D.P.M Laid to Manufacturers
Instructions.
Proprietary Radon Barrier, Continuous with all
joints lapped and sealed, and with the
appropriate number of sumps and outlets.
Finished Level of Flooring
Concrete Cill with max slope of 15 degrees.
Max threshold height of 15mm where level
access is required.
Aco Drainage Channel or Equal and Approved
where Level Access Threshold Provided.
Door unit to have proprietary lower threshold
system as required where level access
requirement is noted on drawings.
Door Threshold Detail
SCALE 1:10 @ A1, 1:20 @ A3
5
Min. 120mm HD Floor Insulation - K3
Kooltherm Floorboard or equal and approved.
1200 Gauge D.P.M Laid to Manufacturers
Instructions.
Proprietary Radon Barrier, Continuous with all
joints lapped and sealed, and with the
appropriate number of sumps and outlets.
Concrete Cill with max slope of 15 degrees.
Max threshold height of 15mm where level
access is required.
Aco Drainage Channel or Equal and Approved
where Level Access Threshold Provided.
75mm Screed on Min. on
125mm Thick 25N20 Subfloor Slab
All Services Laid Prior To Pouring & Power
Floated To Smooth Level Finish
S&C Screed is Airtight Layer - to be fully sealed
and taped to wall prior to S&C plastering.
25mm High Density Vertical Insulation
separating the warm concrete slab from the
structural wall.
Lightweight Concrete Blocks to be used where
the insulation layer meets the wall.
Triple Glazed Low-e, Argon Filled Window.
Min U-Value 1.4W/m2K.
Fitted in the Line of the Insulation.
Full Height Glazing Detail
SCALE 1:10 @ A1, 1:20 @ A3
6
Steelite Lintel to fully close cavity
100mm Block Outer Leaf
Triple Glazed Low-e, Argon Filled Window.
Min U-Value 1.4W/m2K.
Fitted in the Line of the Insulation.
Stepped DPC
Lightweight Concrete Blocks to be used where
the insulation layer meets the wall.
Airtight Membrane taped to Window Frame,
and taped back to primed blockwork wall at
first floor level.
WINDOWS AND DOORS DETAILS - HEAD, CILL AND JAMB.
ACCEPTABLE CONSTRUCTION DETAILS
Sign off required to ensure Thermal Bridging Value
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
04/06/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS
TITLE:
TENDER
T-D-004
As Shown
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com
12. Slates to be laid to Manufacturers's Instructions.
50mm Clear Ventilation Gap Using
Proprietary Spacers Under Sarking
Felt Where Necessary Along Eaves
Black PVC Soffit and Fascia, with Vent to provide
continuous air ventilation gap to cold roof space.
120mmCavity Wall filled with 80mm HD
Insulation (Kooltherm K5 EWB or equal and
approved to achieve a minimum U-Value of
0.15 W/m2K.
55 x 33mm Battens on Breather Membrane
2 Coats Sand & Cement Plaster
With Napped Finish
on 100mm Block Outer Leaf
Slate Cavity Closer.
Black PVC Gutters and Downpipes,
Laid and Fixed to Manufacturer's Instructions
Sarking Felt to lap into Gutter.
Min 300mm Insulation between and
above Ceiling Joists to Continue down
to insulation in wall, providing a
continuous insulation layer.
225mm Rafters to be Strapped to wall
with 30x5mm Galvanised Straps.
100 x 75mm Wall Plate with 12mm
Rawl bolts @ 1m Centres.
12.5mm Sand & Cement Plaster Layer to
100mm Inner Blockwork Wall.
S&C Plaster acts as airtight layer, all
penetrations to be sealed and plastered over.
Airtight Membrane at Ceiling Level (on Warm
Side of Insulation), above Plasterboard Ceiling. -
All penetrations to be taped and sealed. AIrtight
Layer membrane to be taped down to blockwork
wall before plastering and plastered over to seal.
Continuous Insulation between Wall
and Roof.
Roof Detail 1
SCALE 1:10 @ A1, 1:20 @ A3
1
Additional Wall Ties at top of Wall to firmly tie
two leaves of cavity wall together
ROOF DETAILS
ACCEPTABLE CONSTRUCTION DETAILS
Sign off required to ensure Thermal Bridging Value
ISSUE:
PROJECT NO:
1515
DRAWN / CHECKED
JD/MD
DRAWING NO:
SCALE:
REV NO:
DATE
04/06/2015
CLIENT:
LOCATION:
FARRELL'S CROSS, KILDARE, CO. KILDARE.
PROJECT
RENOVATIONS & REFURBISHMENTS
TITLE:
TENDER
T-D-006
As Shown
JAMES & CARMEL O BRIEN
Ph: (087) 2658843 and (087) 6344679 Tel: (045) 531446
E-mail: mark@dalyhudson.com E-mail: jolene@dalyhudson.comwww.dalyhudson.com