Warsaw, September 1-4, 2008
TECHNICAL   PARAMETERS *  (for stent diameter   4.5  and  5.0 mm  use guiding catheter  6F ) Warsaw, September 1-4, 2008 Anti-proliferative agent paclitaxel (ca. 1 µ g/mm 2 ) Polymer Biodegradable Stent diameter 2.25 – 5.00 mm Stent length  (mm) 8, 10, 12, 1 5 , 18, 2 2 , 2 5, 29, 34 Stent platform stainless steel 316L Strut thickness 0.12mm Design closed cell -  for uniform drug distribution and coverage of the vessel wall  Ferromagnetism none MRI safe Use with guide wire max  .014” Use with guiding catheter 5F * Length reduction after deployment < 0 .5 % Recoil  <2% Stent crimped profile .0 40 ” (for stent diameter 3mm) Distal shaft diameter 2.7F/0.90 mm Proximal shaft diameter  2F/0.65 mm Nominal pressure  / RBP 10  atm / 16 atm
The surface of the stent  after 1 week The surface after 8 weeks ,[object Object],[object Object],Warsaw, September 1-4, 2008 DEGRADATION OF TESTED POLYMER
EXCELLENT C OATING  I NTEGRITY   OF LUC-CHOPIN 2  STENT Warsaw, September 1-4, 2008
COMPETITOR   SIROLIMUS   ELUTING   STENT Warsaw, September 1-4, 2008
Warsaw, September 1-4, 2008
LIST OF ABSTRACTS PRESTENTED AT INTERNATIONAL CONGRESSES - WCC Barcelona 2006,  - TCT 2005, 2006, 2008 Washington - ESC Vienna, 2007 - International LDDR meeting, Geneva 2006, 2008 - Interventional cardiology meeting, Snowmass 2008 1 st  prize for Balton! Warsaw, September 1-4, 2008
Warsaw, September 1-4, 2008
Chopin 2  TM  - STENT FOR CORONARY ARTERIES WITH DELIVERY SYSTEM *  (for stent diameter   4.5  and  5.0 mm  use guiding catheter  6F ) Warsaw, September 1-4, 2008 Technical parameters of stent Material steel 316 L Design closed cell Strut thickness 0.12 mm Stent diameter 2.25 – 5.00 mm Stent length 8, 10, 12, 1 5 , 18, 2 2 , 2 5, 29, 34  mm MRI safe Use with guide wire .014” Use with guiding catheter 5F * Length reduction after deployment < 0 .5 % Recoil  <2% Stent crimped profile .038”/0.97 mm  (for stent diameter 3mm) Distal shaft diameter 2.7F/0.90 mm Proximal shaft diameter  2F/0.65 mm Nominal pressure /RBP 10  atm/16atm
Chopin 2  STENT REGISTRY  - CLINICAL OUTCOMES AFTER 6 MONTHS * clinically driven Warsaw, September 1-4, 2008 Events n=97 Death 0 (0%) ,[object Object],[object Object],[object Object],0 (0%) 0 (0%) Emergent CABG 2 (1.9%) TLR* 22 (22.6%) Revascularization per patient 0.24 Cumulative MACE 24 (24.7%) Late thrombosis 0 (0%)
Warsaw, September 1-4, 2008
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],CATHETERS FOR ANGIOGRAPHY Warsaw, September 1-4, 2008
CARDIOLOGICAL   INTRODUCER Radiological introducer Radial artery cardiological introducer Warsaw, September 1-4, 2008
GUIDEWIRES For  i nterventional cardiology  &  radiology   The tip of the guidewire is appropriately shaped and atraumatic   for   optimal patient's security  D esigned for complex vascular interventions   including &quot;cross-over&quot; techniques. Warsaw, September 1-4, 2008 Guidewires Size Steel guidewires .022”, .035”, .038” Hydrophilic guidewires .032”, .035”, .038” Micro guidewires .007”, .009”, .014” Lunderquist  guidewires .035” PTFE  coated guidewires .018”, .022”, .025”, .035”, .038” PTCA guidewire „Rider” .014”
PTCA G UIDE   WIRES  „RIDER” – WITH HYDROPHILIC COATING ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],Warsaw, September 1-4, 2008 Guidewire Size Length Type PTCA  guidewires .014” 175 – 300 cm „ J” Straight
PERIPHERAL ANGIOPLASTY CATHETER  PBA Warsaw, September 1-4, 2008 Balloon diameter 4 - 1 2  mm Balloon length 20  - 100 mm Use with introducer For balloon diameter 4 –  7  mm 6F Use with introducer For balloon diameter  8  –  10  mm 7F Use with introducer For balloon diameter 1 2  mm 8F Nominal pressure 6  atm Rated Burst Pressure RBP 10  atm Catheter length 80 or 110 cm Typ e of delivery system OTW
CORONARY   ANGIOPLASTY   CATHETER NEW   VERSION Warsaw, September 1-4, 2008 Balloon diameter 1.5  –  5.0  mm Balloon length 10  -  4 0 mm Use with  guiding catheter For balloon diameter  1.5  –  4.0 mm 5 F Use with  guiding catheter For balloon diameter  4.5   – 5.0 mm 6 F Nominal pressure 10   atm Rated Burst Pressure RBP 1 6   atm Catheter length 140  cm Typ e of delivery system RX
Nefro TM  - STENT FOR RENAL ARTERIES WITH DELIVERY SYSTEM - Rapid Exchange  (RX) Warsaw, September 1-4, 2008 Material 316 stainless steel Guide wire  Max .014” Guiding catheter 6F Nominal pressure 8 atm Rated burst pressure 12 atm Available diameters 5.0 – 7.0mm Lengths 8.0 – 22.0mm
Neptun TM  - STENT FOR PERIPHERAL VESSELS WITH DELIVERY SYSTEM Warsaw, September 1-4, 2008 Stent diameter 4 - 10 mm Stent length 16 - 100 mm Use with guide wire .035” Use with  introducer for stent diameter 4 –  6  mm 6F Use with  introducer for stent diameter  7  – 9 mm 7F Use with  introducer for stent diameter 10 mm 8F Nominal Pressure 6  atm Rated Burst Pressure 10  atm Catheter length 80 or 110 cm Delivery system type OTW
Jaguar TM  -SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEM The Jaguar SM  self-expanding stent with a delivery system is recommended for percutaneous intravascular deployment in patients with atherosclerotic, radiation and trauma-induced stenoses. The soft and rounded tip of delivery system is atraumatic towards the arterial wall. S pecial construction of delivery system enable to correction of stent position inside a vessel even after the partial stent release Warsaw, September 1-4, 2008 Material Nitinol wire with platinum markers Available diameters 4.0 – 10.0 mm Lengths 15.0 – 120.0 mm
T rachea l  and esophag eal stent - TOR Tracheal and esophageal T or  stent is made of nitinol, which is material  of high biocompatibility. Tor  stent with the delivery system provides high efficiency and comfort of   application during an attempt to restore patency of highly stenotic trachea, bronchi or esophagus. Thanks to its perfect elasticity the stent perfectly matches the shape of the  trachea and esophagus. A special construction of the stent protects against migration. The delivery system is characterised by high elasticity. Atraumatic endings of the system minimise the risk of damage during the   procedure. ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],TOR Warsaw, September 1-4, 2008
Large vessel catheterization set  with: - Single lumen catheter - Double lumen catheter - Triple lumen catheter - Four lumen catheter Anaesthesia sets   Warsaw, September 1-4, 2008
Thermodilution set   “ B ALKAT” Spinal anaesthesia needles Warsaw, September 1-4, 2008
Dialysis sets Hemodialysis needles Warsaw, September 1-4, 2008
Embolectomy catheters Aortic catheters Catheter for bile duct’s  Drains Warsaw, September 1-4, 2008
-  Nephrostomy sets Nephrostomy & cystostomy set -  Cystostomy s e ts -  Ureteral catheters -  Sets for stent introduction Warsaw, September 1-4, 2008
[object Object],[object Object],[object Object],Warsaw, September 1-4, 2008

Contenu connexe

Tendances (12)

Rapid fire Tipps and Tricks – 5 min: What do do if …microcatheter cannot pass...
Rapid fire Tipps and Tricks – 5 min: What do do if …microcatheter cannot pass...Rapid fire Tipps and Tricks – 5 min: What do do if …microcatheter cannot pass...
Rapid fire Tipps and Tricks – 5 min: What do do if …microcatheter cannot pass...
 
Mat hbs
Mat hbsMat hbs
Mat hbs
 
Tortuous vessel pci navin
Tortuous vessel pci navin Tortuous vessel pci navin
Tortuous vessel pci navin
 
Dispositivos de proteção distal
Dispositivos de proteção distalDispositivos de proteção distal
Dispositivos de proteção distal
 
Maxilo Facial dos
Maxilo Facial dosMaxilo Facial dos
Maxilo Facial dos
 
Distal protection device
Distal protection deviceDistal protection device
Distal protection device
 
Ultraverse035
Ultraverse035Ultraverse035
Ultraverse035
 
Coronary guidewires
Coronary guidewiresCoronary guidewires
Coronary guidewires
 
CTO
CTO CTO
CTO
 
Fraser D
Fraser DFraser D
Fraser D
 
Yankaur Suction Set
Yankaur Suction SetYankaur Suction Set
Yankaur Suction Set
 
Retrograde cto interv.
Retrograde cto interv.Retrograde cto interv.
Retrograde cto interv.
 

Similaire à Balton From Poland

10:05 Gershlick - The kit
10:05 Gershlick -  The kit10:05 Gershlick -  The kit
10:05 Gershlick - The kitEuro CTO Club
 
ASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-CatalogASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-Catalognishadvellur
 
coronary stents- dr vivek kumaresan.pptx
coronary stents- dr vivek kumaresan.pptxcoronary stents- dr vivek kumaresan.pptx
coronary stents- dr vivek kumaresan.pptxAadhi55
 
wires and stents.pptx
wires and stents.pptxwires and stents.pptx
wires and stents.pptxahmedmedohoda
 
New wires, what we have, what is essential, what is on the horizon
New wires, what we have, what is essential, what is on the horizonNew wires, what we have, what is essential, what is on the horizon
New wires, what we have, what is essential, what is on the horizonEuro CTO Club
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalogKevin Yang
 
Cat_08a_en_Festoon_systems_S_profile.pdf
Cat_08a_en_Festoon_systems_S_profile.pdfCat_08a_en_Festoon_systems_S_profile.pdf
Cat_08a_en_Festoon_systems_S_profile.pdfKyriakos Michalaki
 
Hellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable Ties
Hellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable TiesHellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable Ties
Hellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable TiesThorne & Derrick International
 
Braun differential hall effect based sensor
Braun differential hall effect based sensorBraun differential hall effect based sensor
Braun differential hall effect based sensortobalin
 
Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...
Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...
Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...ENVIMART
 
ANGIOGRAPHY 5418.pptx
ANGIOGRAPHY 5418.pptxANGIOGRAPHY 5418.pptx
ANGIOGRAPHY 5418.pptxshibina15
 

Similaire à Balton From Poland (20)

10:05 Gershlick - The kit
10:05 Gershlick -  The kit10:05 Gershlick -  The kit
10:05 Gershlick - The kit
 
Cardiac catheters
Cardiac cathetersCardiac catheters
Cardiac catheters
 
ASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-CatalogASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-Catalog
 
coronary stents- dr vivek kumaresan.pptx
coronary stents- dr vivek kumaresan.pptxcoronary stents- dr vivek kumaresan.pptx
coronary stents- dr vivek kumaresan.pptx
 
wires and stents.pptx
wires and stents.pptxwires and stents.pptx
wires and stents.pptx
 
Krohne Vibrating Fork Level Switches
Krohne Vibrating Fork Level SwitchesKrohne Vibrating Fork Level Switches
Krohne Vibrating Fork Level Switches
 
New wires, what we have, what is essential, what is on the horizon
New wires, what we have, what is essential, what is on the horizonNew wires, what we have, what is essential, what is on the horizon
New wires, what we have, what is essential, what is on the horizon
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalog
 
Urology
UrologyUrology
Urology
 
2 mat cordless-drill
2 mat cordless-drill2 mat cordless-drill
2 mat cordless-drill
 
Cat_08a_en_Festoon_systems_S_profile.pdf
Cat_08a_en_Festoon_systems_S_profile.pdfCat_08a_en_Festoon_systems_S_profile.pdf
Cat_08a_en_Festoon_systems_S_profile.pdf
 
Hellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable Ties
Hellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable TiesHellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable Ties
Hellermann Tyton - Cable Ties, Fixings & Stainless Steel Cable Ties
 
Braun differential hall effect based sensor
Braun differential hall effect based sensorBraun differential hall effect based sensor
Braun differential hall effect based sensor
 
Urology catalogue new
Urology catalogue new Urology catalogue new
Urology catalogue new
 
The story of coronary stent
The story of coronary stentThe story of coronary stent
The story of coronary stent
 
Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...
Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...
Dynasonics tfx 500w datasheet badger meter-clamp-on transit time ultrasonic f...
 
ANGIOGRAPHY 5418.pptx
ANGIOGRAPHY 5418.pptxANGIOGRAPHY 5418.pptx
ANGIOGRAPHY 5418.pptx
 
Staniloae C - Transradial peripheral vascular interventions
Staniloae C - Transradial peripheral vascular interventionsStaniloae C - Transradial peripheral vascular interventions
Staniloae C - Transradial peripheral vascular interventions
 
PRESENTATION REPORT.pptx
PRESENTATION REPORT.pptxPRESENTATION REPORT.pptx
PRESENTATION REPORT.pptx
 
Centrix
CentrixCentrix
Centrix
 

Balton From Poland

  • 2. TECHNICAL PARAMETERS * (for stent diameter 4.5 and 5.0 mm use guiding catheter 6F ) Warsaw, September 1-4, 2008 Anti-proliferative agent paclitaxel (ca. 1 µ g/mm 2 ) Polymer Biodegradable Stent diameter 2.25 – 5.00 mm Stent length (mm) 8, 10, 12, 1 5 , 18, 2 2 , 2 5, 29, 34 Stent platform stainless steel 316L Strut thickness 0.12mm Design closed cell - for uniform drug distribution and coverage of the vessel wall Ferromagnetism none MRI safe Use with guide wire max .014” Use with guiding catheter 5F * Length reduction after deployment < 0 .5 % Recoil <2% Stent crimped profile .0 40 ” (for stent diameter 3mm) Distal shaft diameter 2.7F/0.90 mm Proximal shaft diameter 2F/0.65 mm Nominal pressure / RBP 10 atm / 16 atm
  • 3.
  • 4. EXCELLENT C OATING I NTEGRITY OF LUC-CHOPIN 2 STENT Warsaw, September 1-4, 2008
  • 5. COMPETITOR SIROLIMUS ELUTING STENT Warsaw, September 1-4, 2008
  • 7. LIST OF ABSTRACTS PRESTENTED AT INTERNATIONAL CONGRESSES - WCC Barcelona 2006, - TCT 2005, 2006, 2008 Washington - ESC Vienna, 2007 - International LDDR meeting, Geneva 2006, 2008 - Interventional cardiology meeting, Snowmass 2008 1 st prize for Balton! Warsaw, September 1-4, 2008
  • 9. Chopin 2 TM - STENT FOR CORONARY ARTERIES WITH DELIVERY SYSTEM * (for stent diameter 4.5 and 5.0 mm use guiding catheter 6F ) Warsaw, September 1-4, 2008 Technical parameters of stent Material steel 316 L Design closed cell Strut thickness 0.12 mm Stent diameter 2.25 – 5.00 mm Stent length 8, 10, 12, 1 5 , 18, 2 2 , 2 5, 29, 34 mm MRI safe Use with guide wire .014” Use with guiding catheter 5F * Length reduction after deployment < 0 .5 % Recoil <2% Stent crimped profile .038”/0.97 mm (for stent diameter 3mm) Distal shaft diameter 2.7F/0.90 mm Proximal shaft diameter 2F/0.65 mm Nominal pressure /RBP 10 atm/16atm
  • 10.
  • 12.
  • 13. CARDIOLOGICAL INTRODUCER Radiological introducer Radial artery cardiological introducer Warsaw, September 1-4, 2008
  • 14. GUIDEWIRES For i nterventional cardiology & radiology The tip of the guidewire is appropriately shaped and atraumatic for optimal patient's security D esigned for complex vascular interventions including &quot;cross-over&quot; techniques. Warsaw, September 1-4, 2008 Guidewires Size Steel guidewires .022”, .035”, .038” Hydrophilic guidewires .032”, .035”, .038” Micro guidewires .007”, .009”, .014” Lunderquist guidewires .035” PTFE coated guidewires .018”, .022”, .025”, .035”, .038” PTCA guidewire „Rider” .014”
  • 15.
  • 16. PERIPHERAL ANGIOPLASTY CATHETER PBA Warsaw, September 1-4, 2008 Balloon diameter 4 - 1 2 mm Balloon length 20 - 100 mm Use with introducer For balloon diameter 4 – 7 mm 6F Use with introducer For balloon diameter 8 – 10 mm 7F Use with introducer For balloon diameter 1 2 mm 8F Nominal pressure 6 atm Rated Burst Pressure RBP 10 atm Catheter length 80 or 110 cm Typ e of delivery system OTW
  • 17. CORONARY ANGIOPLASTY CATHETER NEW VERSION Warsaw, September 1-4, 2008 Balloon diameter 1.5 – 5.0 mm Balloon length 10 - 4 0 mm Use with guiding catheter For balloon diameter 1.5 – 4.0 mm 5 F Use with guiding catheter For balloon diameter 4.5 – 5.0 mm 6 F Nominal pressure 10 atm Rated Burst Pressure RBP 1 6 atm Catheter length 140 cm Typ e of delivery system RX
  • 18. Nefro TM - STENT FOR RENAL ARTERIES WITH DELIVERY SYSTEM - Rapid Exchange (RX) Warsaw, September 1-4, 2008 Material 316 stainless steel Guide wire Max .014” Guiding catheter 6F Nominal pressure 8 atm Rated burst pressure 12 atm Available diameters 5.0 – 7.0mm Lengths 8.0 – 22.0mm
  • 19. Neptun TM - STENT FOR PERIPHERAL VESSELS WITH DELIVERY SYSTEM Warsaw, September 1-4, 2008 Stent diameter 4 - 10 mm Stent length 16 - 100 mm Use with guide wire .035” Use with introducer for stent diameter 4 – 6 mm 6F Use with introducer for stent diameter 7 – 9 mm 7F Use with introducer for stent diameter 10 mm 8F Nominal Pressure 6 atm Rated Burst Pressure 10 atm Catheter length 80 or 110 cm Delivery system type OTW
  • 20. Jaguar TM -SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEM The Jaguar SM self-expanding stent with a delivery system is recommended for percutaneous intravascular deployment in patients with atherosclerotic, radiation and trauma-induced stenoses. The soft and rounded tip of delivery system is atraumatic towards the arterial wall. S pecial construction of delivery system enable to correction of stent position inside a vessel even after the partial stent release Warsaw, September 1-4, 2008 Material Nitinol wire with platinum markers Available diameters 4.0 – 10.0 mm Lengths 15.0 – 120.0 mm
  • 21.
  • 22. Large vessel catheterization set with: - Single lumen catheter - Double lumen catheter - Triple lumen catheter - Four lumen catheter Anaesthesia sets Warsaw, September 1-4, 2008
  • 23. Thermodilution set “ B ALKAT” Spinal anaesthesia needles Warsaw, September 1-4, 2008
  • 24. Dialysis sets Hemodialysis needles Warsaw, September 1-4, 2008
  • 25. Embolectomy catheters Aortic catheters Catheter for bile duct’s Drains Warsaw, September 1-4, 2008
  • 26. - Nephrostomy sets Nephrostomy & cystostomy set - Cystostomy s e ts - Ureteral catheters - Sets for stent introduction Warsaw, September 1-4, 2008
  • 27.