Immersion Disposable Thermocouples are used to measure the temperature directly, precisely and instantly through immersion method, in the production & refining of iron, steel & other ferrous and non-ferrous in Electric Arc Furnaces, other melting furnaces, LD converters, Ladles, etc and for the chemical analysis of the metal during its manufacturing stage. It is a simple and cost effective instrument and provides the quickest way to get the most accurate readings. To measure the temperature, the thermocouple is connected to the coupling lance. Which contains the polarized contact block.
4. EXPENDABLE THERMOCOUPLE
Immersion Disposable Thermocouples are used to measure the
temperature directly, precisely and instantly through immersion
method, in the production & refining of iron, steel & other ferrous
and non-ferrous in Electric Arc Furnaces, other melting furnaces,
LD converters, Ladles, etc and for the chemical analysis of the
metal during its manufacturing stage. It is a simple and cost
effective instrument and provides the quickest way to get the most
accurate readings. To measure the temperature, the thermocouple is
connected to the coupling lance. Which contains the polarized
contact block.
Thermocouple Parts:
1) Protection cap : The thermocouple cap is part of the “Disposable Immersion
Thermocouple”. It is made of Steel or Aluminum
2) Insulating Body : This part is made of Ceramic, ABS or Plastic body.
3) Tips : The Thermocouple Tips are manufactured using high accuracy
Platinum and Platinum-Rhodium wires under strict quality
controls.
Technical Data and Specification
Calibration of the thermocouples wires : According to IEC (CEI) 585, equivalent with ASTM E 230/72, DIN
IEC 585 Part 1:1995, BS 5937; 1973, ANSIC 96-1-1992, NFC 52-321-1978, JIS 1602/1982, based on the
temperature scale ITS 90
Thermocouple accuracy at : (0…+5)°C
Melting point Pd (1555°C) : By request, accuracy of thermocouple cap can be 5…0°C
Max. Immersion time at 1650°C : 7 seconds
Measuring time : 3 to 6 seconds
4
5. Specifications & technical features of the thermocouple
Type Alloy of +ve wire Alloy of -ve wire Temperature range Max. Tolerance Return circuit
Temp. resistance
S Platinum 10% Rhodium Platinum 0 to 1550 Deg C 1650° C ≤+5° C <3Ω
(90% Pt - 10% Rh) (100% Pt) 32 to 2650 Deg F
R Platinum 13% Rhodium Platinum 0 to 1550 Deg C 1650° C ≤+5° C <3Ω
(87% Pt - 13% Rh) (100% Pt) 32 to 2650 Deg F
B Platinum 30% Rhodium Platinum 6% 0 to 1700 Deg C 1800° C ≤+5° C <3Ω
(70% Pt - 30% Rh) Rhodium(95% 32 to 3100 Deg F
Pt - 6% Rh)
The Expendable Thermocouple tip is introduced inside the cardboard tube available in length from
300mm, 600mm, 900mm and 1200mm and as per customer requirement.
Advantage
Capable of being used to directly measure temperatures up to 2600oC.
The thermocouple junction may be grounded and brought into direct contact with the material being
measured.
Designed & manufactured to obtain optimum accuracy, convenience, cost
effectiveness & safety
Application
Temperature measurement in Blast Furnace, Convertors, Electrical Furnace, Ladle Oven, Iron Foundry, Copper
Melts and other alloys.
Packing:- 25 or 50 Pcs. per Cardboard box.
5
6. CORE VALUES
Customer Loyalty & Customer Satisfaction.
Commitment to Quality.
Continuous Communication
Aim and achieve efficiency improvements and loss reduction.
Be open to change and adopt best practices in operations and
project management to improve systems availability, quality and
security.
Create an environment that motivates employee performance and
values their contribution.
Develop and train employees, enhance their skills by job rotation
and job enrichment and encourage them to take greater
responsibilities.
Ensure that system reliability, safety and security are not
compromised.
Please contact for more details:
REMSO CONTROL TECHNOLOGIES PVT. LTD.
D-157, GREATER NOIDA EXPORT PROMOTION INDUSTRIAL PARK, KASNA,
GREATER NOIDA, DIST:- GAUTAM BUDH NAGAR,201308,INDIA
Phone: +91-120-4290183 , Fax: +91-120-4295183, Mobile :+91-9810339183
Email ID : info@remso.com , remso2002@gmail.com www.remso.com
6