1. The aim of the project is to monitor energy
meter reading, the cost of the electricity usage,
intimate power cut before shutdown and also to
indicate current theft by sending SMS to users by
using GSM modem and Zigbee system.
2.
The energy meter monitoring and taking of
the readings need man power.
No communication between Electricity board
and users
Chances of power theft.
3.
Automatically calculates the energy
consumed without using man power.
It intimates shutdown time in advance.
Avoids power theft by other users.
provides communication between user and
EB
4.
5.
6.
In this system the PIC microcontroller is used
for efficient energy meter monitoring system.
This system is connected to energy meter
with load.
The IR receiver is used to count the reading
of the energy meter.
The value of the IR receiver will be given to
the microcontroller.
This value is transmitted to the EB section
through ZIGBEE.
7. The EB section uses GSM modem to send
details of energy consumed with charge to be
paid.
If not paid before due date, EB section sends
DISCONNECT command to home section via
zigbee. Thus relay gets disconnected.
The power shut down details are transmitted
to the home from the EB section using the
ZIGBEE.
10.
The developed system reduces interaction
between the user and EB personnel.
The system can be modified by using latest
SPI metering ICs which will provide more
parameters.
Power factor improvement options can be
added in future.
11.
[1] Yujun Bao and Xiaoyan Jiang, “Design of electric Energy Meter for long-distance data
information transfers which based upon GPRS”, ISA 2009. International Workshop on
Intelligent Systems and Applications 2009.
[2] Bharath P, Ananth N, Vijetha S, Jyothi Prakash K. V. ,“Wireless automated digital
Energy Meter”, ICSET 2008
P.K. Lee and L.L. Lai, Fieee, “A practical approach to wireless GPRS on-line power quality
monitoring system”, Power Engineering Society General Meeting, 2007
Li Kaicheng, Liu Jianfeng, Yue Congyuan, Zhang Ming. “Remote power management and
meter-reading system based on ARM microprocessor”, Precision Electromagnetic
Measurements Digest,2008. CPEM 2008. Conference on Digital Object identifier.
M.P Praveen, “KSEB to introduce SMS-based fault maintenance system”, The Hindu News
on 26/06/2011, http://www.hindu.com.
H.G.Rodney Tan, C.H. Lee,V.H.Mok, “Automatic power meter reading system using GSM
network”, The 8 Conference (IPEC 2007).International Power Engineering