Soumettre la recherche
Mettre en ligne
Phoenix controls
•
1 j'aime
•
4,522 vues
VICTOR SALAZAR
Suivre
Phoenix controls config
Lire moins
Lire la suite
Ingénierie
Signaler
Partager
Signaler
Partager
1 sur 16
Télécharger maintenant
Télécharger pour lire hors ligne
Recommandé
Distributed Control System Basics
Distributed Control System Basics
Pratap Chandra
Practical Use & Understanding of Foundation FieldBus for Engineers & Technicians
Practical Use & Understanding of Foundation FieldBus for Engineers & Technicians
Living Online
YOKOGAWA CENTUM CS 3000 R3
YOKOGAWA CENTUM CS 3000 R3
Rehan Fazal
Plant Operation System
Plant Operation System
penso-logo-existo
DCS PRESENTATION
DCS PRESENTATION
bvent2005
Utilizing DeltaV Advanced Control Innovations to Improve Control Performance
Utilizing DeltaV Advanced Control Innovations to Improve Control Performance
Emerson Exchange
Travaux pratiques corrigé logiciel ARENA
Travaux pratiques corrigé logiciel ARENA
SandraKobe
Different kinds of signals used in the DCS
Different kinds of signals used in the DCS
Ajit Kumar
Recommandé
Distributed Control System Basics
Distributed Control System Basics
Pratap Chandra
Practical Use & Understanding of Foundation FieldBus for Engineers & Technicians
Practical Use & Understanding of Foundation FieldBus for Engineers & Technicians
Living Online
YOKOGAWA CENTUM CS 3000 R3
YOKOGAWA CENTUM CS 3000 R3
Rehan Fazal
Plant Operation System
Plant Operation System
penso-logo-existo
DCS PRESENTATION
DCS PRESENTATION
bvent2005
Utilizing DeltaV Advanced Control Innovations to Improve Control Performance
Utilizing DeltaV Advanced Control Innovations to Improve Control Performance
Emerson Exchange
Travaux pratiques corrigé logiciel ARENA
Travaux pratiques corrigé logiciel ARENA
SandraKobe
Different kinds of signals used in the DCS
Different kinds of signals used in the DCS
Ajit Kumar
Cours_pneumatique.ppt
Cours_pneumatique.ppt
AbderrazakMiassar2
RA TechED 2019 - CL01 - Integrated Architecture System Hardware - what's new
RA TechED 2019 - CL01 - Integrated Architecture System Hardware - what's new
Rockwell Automation
CENTUM CS300 R3
CENTUM CS300 R3
AhmedAmri23
Distributed Control System (Presentation)
Distributed Control System (Presentation)
Thunder Bolt
CENTUM VP - 2014 version
CENTUM VP - 2014 version
Yokogawa
PlantPAx Process
PlantPAx Process
Avanceon-Lahore
When is a SIL Rating of a Valve Required?
When is a SIL Rating of a Valve Required?
ISA Interchange
Dcs
Dcs
AKANSHA GURELE
Honeywell Experion HS
Honeywell Experion HS
Shivam Singh
NFS-320
NFS-320
aescotom
Intro to IO-Link
Intro to IO-Link
Neil Farrow, P.E.
Client oriented approach for physical examination of animals
Client oriented approach for physical examination of animals
Himanshu Pandey
Plc 101
Plc 101
Wendell Agasen
Mammary tumors
Mammary tumors
Dr Alok Bharti
PLC Introduction Details
PLC Introduction Details
suhaskhadake
Foundation fieldbus technology
Foundation fieldbus technology
Mohamed A Hakim
Fieldbus Tutorial Part 1 - Fieldbus Overview
Fieldbus Tutorial Part 1 - Fieldbus Overview
Emerson Exchange
Presentaton on Plc & Scada
Presentaton on Plc & Scada
Nokia Technology
Foundation fieldbus
Foundation fieldbus
sharadonlinemails
Internal and external parasites prof.dr Hamed Attia
Internal and external parasites prof.dr Hamed Attia
hamed attia
4603-0001 - LCD Annunciator - 4603-9101.PDF
4603-0001 - LCD Annunciator - 4603-9101.PDF
SourovSamadder
Machine monitoring system
Machine monitoring system
Prem Baboo
Contenu connexe
Tendances
Cours_pneumatique.ppt
Cours_pneumatique.ppt
AbderrazakMiassar2
RA TechED 2019 - CL01 - Integrated Architecture System Hardware - what's new
RA TechED 2019 - CL01 - Integrated Architecture System Hardware - what's new
Rockwell Automation
CENTUM CS300 R3
CENTUM CS300 R3
AhmedAmri23
Distributed Control System (Presentation)
Distributed Control System (Presentation)
Thunder Bolt
CENTUM VP - 2014 version
CENTUM VP - 2014 version
Yokogawa
PlantPAx Process
PlantPAx Process
Avanceon-Lahore
When is a SIL Rating of a Valve Required?
When is a SIL Rating of a Valve Required?
ISA Interchange
Dcs
Dcs
AKANSHA GURELE
Honeywell Experion HS
Honeywell Experion HS
Shivam Singh
NFS-320
NFS-320
aescotom
Intro to IO-Link
Intro to IO-Link
Neil Farrow, P.E.
Client oriented approach for physical examination of animals
Client oriented approach for physical examination of animals
Himanshu Pandey
Plc 101
Plc 101
Wendell Agasen
Mammary tumors
Mammary tumors
Dr Alok Bharti
PLC Introduction Details
PLC Introduction Details
suhaskhadake
Foundation fieldbus technology
Foundation fieldbus technology
Mohamed A Hakim
Fieldbus Tutorial Part 1 - Fieldbus Overview
Fieldbus Tutorial Part 1 - Fieldbus Overview
Emerson Exchange
Presentaton on Plc & Scada
Presentaton on Plc & Scada
Nokia Technology
Foundation fieldbus
Foundation fieldbus
sharadonlinemails
Internal and external parasites prof.dr Hamed Attia
Internal and external parasites prof.dr Hamed Attia
hamed attia
Tendances
(20)
Cours_pneumatique.ppt
Cours_pneumatique.ppt
RA TechED 2019 - CL01 - Integrated Architecture System Hardware - what's new
RA TechED 2019 - CL01 - Integrated Architecture System Hardware - what's new
CENTUM CS300 R3
CENTUM CS300 R3
Distributed Control System (Presentation)
Distributed Control System (Presentation)
CENTUM VP - 2014 version
CENTUM VP - 2014 version
PlantPAx Process
PlantPAx Process
When is a SIL Rating of a Valve Required?
When is a SIL Rating of a Valve Required?
Dcs
Dcs
Honeywell Experion HS
Honeywell Experion HS
NFS-320
NFS-320
Intro to IO-Link
Intro to IO-Link
Client oriented approach for physical examination of animals
Client oriented approach for physical examination of animals
Plc 101
Plc 101
Mammary tumors
Mammary tumors
PLC Introduction Details
PLC Introduction Details
Foundation fieldbus technology
Foundation fieldbus technology
Fieldbus Tutorial Part 1 - Fieldbus Overview
Fieldbus Tutorial Part 1 - Fieldbus Overview
Presentaton on Plc & Scada
Presentaton on Plc & Scada
Foundation fieldbus
Foundation fieldbus
Internal and external parasites prof.dr Hamed Attia
Internal and external parasites prof.dr Hamed Attia
Similaire à Phoenix controls
4603-0001 - LCD Annunciator - 4603-9101.PDF
4603-0001 - LCD Annunciator - 4603-9101.PDF
SourovSamadder
Machine monitoring system
Machine monitoring system
Prem Baboo
Datasheet foxboro eckardt srd991 18463765
Datasheet foxboro eckardt srd991 18463765
IkhuoshoAbode
4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf
SourovSamadder
13.Safety & navigation
13.Safety & navigation
Marine Hardware
Siemens Terminal Box Controller (APOGEE Automation System )
Siemens Terminal Box Controller (APOGEE Automation System )
CONTROLS & SYSTEMS
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.com
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.com
Beeteco
K85000-0391 -- Releasing Module Flyer.pdf
K85000-0391 -- Releasing Module Flyer.pdf
SecorpSAS
Elc Inverter Introduction
Elc Inverter Introduction
scottburge
Dn 60779 pdf
Dn 60779 pdf
VanHalenNteksystems
Innovations - Ability 11.02.14
Innovations - Ability 11.02.14
Overbury
EL-FLOW Prestige Mass Flow Controller and Flow Meter
EL-FLOW Prestige Mass Flow Controller and Flow Meter
Hile Controls of Alabama, Inc.
Fadal Diagnostics Maintenance Manual
Fadal Diagnostics Maintenance Manual
Independent Technology Service Inc
CATV Optical Transmitter
CATV Optical Transmitter
QuestTel Broadcast Systems
Horn with Strobe 49AV-WRF.pdf
Horn with Strobe 49AV-WRF.pdf
SourovSamadder
LCD Annunciators
LCD Annunciators
aescotom
Controlador ORP Milton Roy
Controlador ORP Milton Roy
Vibropac
Functional Safety Frequency to DC Transmitter
Functional Safety Frequency to DC Transmitter
Arjay Automation
HEATFAST HF9101-v1 Ambient Sensing Heat Tracing Thermostat - Spec Sheet
HEATFAST HF9101-v1 Ambient Sensing Heat Tracing Thermostat - Spec Sheet
Thorne & Derrick UK
Bien tan-mini
Bien tan-mini
CTY TNHH HẠO PHƯƠNG
Similaire à Phoenix controls
(20)
4603-0001 - LCD Annunciator - 4603-9101.PDF
4603-0001 - LCD Annunciator - 4603-9101.PDF
Machine monitoring system
Machine monitoring system
Datasheet foxboro eckardt srd991 18463765
Datasheet foxboro eckardt srd991 18463765
4903-0010 - Conventional Strobe with Horn.pdf
4903-0010 - Conventional Strobe with Horn.pdf
13.Safety & navigation
13.Safety & navigation
Siemens Terminal Box Controller (APOGEE Automation System )
Siemens Terminal Box Controller (APOGEE Automation System )
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.com
Catalog Biến tần Frenic ACE Mini (Fuji Electric) - Beeteco.com
K85000-0391 -- Releasing Module Flyer.pdf
K85000-0391 -- Releasing Module Flyer.pdf
Elc Inverter Introduction
Elc Inverter Introduction
Dn 60779 pdf
Dn 60779 pdf
Innovations - Ability 11.02.14
Innovations - Ability 11.02.14
EL-FLOW Prestige Mass Flow Controller and Flow Meter
EL-FLOW Prestige Mass Flow Controller and Flow Meter
Fadal Diagnostics Maintenance Manual
Fadal Diagnostics Maintenance Manual
CATV Optical Transmitter
CATV Optical Transmitter
Horn with Strobe 49AV-WRF.pdf
Horn with Strobe 49AV-WRF.pdf
LCD Annunciators
LCD Annunciators
Controlador ORP Milton Roy
Controlador ORP Milton Roy
Functional Safety Frequency to DC Transmitter
Functional Safety Frequency to DC Transmitter
HEATFAST HF9101-v1 Ambient Sensing Heat Tracing Thermostat - Spec Sheet
HEATFAST HF9101-v1 Ambient Sensing Heat Tracing Thermostat - Spec Sheet
Bien tan-mini
Bien tan-mini
Dernier
Air Compressor reciprocating single stage
Air Compressor reciprocating single stage
Abc194748
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
meghakumariji156
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
HenryBriggs2
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
KOUSTAV SARKAR
Hostel management system project report..pdf
Hostel management system project report..pdf
Kamal Acharya
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
soginsider
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
Quintin Balsdon
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
RishantSharmaFr
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
JiananWang21
Online food ordering system project report.pdf
Online food ordering system project report.pdf
Kamal Acharya
School management system project Report.pdf
School management system project Report.pdf
Kamal Acharya
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
Arindam Chakraborty, Ph.D., P.E. (CA, TX)
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
MairaAshraf6
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
Neometrix_Engineering_Pvt_Ltd
Online electricity billing project report..pdf
Online electricity billing project report..pdf
Kamal Acharya
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
DineshKumar4165
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086
anil_gaur
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
hamedmustafa094
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
jaanualu31
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Arindam Chakraborty, Ph.D., P.E. (CA, TX)
Dernier
(20)
Air Compressor reciprocating single stage
Air Compressor reciprocating single stage
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
scipt v1.pptxcxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx...
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
Hostel management system project report..pdf
Hostel management system project report..pdf
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Hazard Identification (HAZID) vs. Hazard and Operability (HAZOP): A Comparati...
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
Online food ordering system project report.pdf
Online food ordering system project report.pdf
School management system project Report.pdf
School management system project Report.pdf
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
Online electricity billing project report..pdf
Online electricity billing project report..pdf
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Phoenix controls
1.
X30 SERIES FUME
HOOD MONITORS 75 Discovery Way • Acton, Massachusetts 01720 • Telephone (978) 795-1285 • Fax (978) 795-1111 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—1 OF 16 Phoenix Controls X30 Series Fume Hood Monitors (FHMs) are used on fume hoods with Phoenix Controls valves for airflow control. Airflow control on these fume hoods is achieved with the use of constant volume valves (CVV), two-position valves (PEV or BEV) or variable air volume valves (VAV). Each FHM provides two primary functions: indication of hood exhaust operating condition and alarming. In VAV systems, each FHM also provides face velocity control and optional energy-saving features. SPECIFICATIONS Enclosure • Dimensions: 2.5" W x 6" H x 1.5" D (64 mm x 152 mm x 38 mm) • Color: White • IP44 compliant Operating Range 32-122 °F (0-50 °C) ambient 10-90% RH, non-condensing 8202’ (2500 m) altitude Power Requirements for Each Unit 24 Vac, ±10%, 50-60 Hz, 10 VA ±15 Vdc, ±5%, 220 mA Inputs and Outputs See table in "Features" section on page 2 for model-specific inputs and outputs. Input to Optional Use LED • Yellow LED indicates unique customer conditions • Wired directly from customer’s device to two dedicated conductors within the eight-wire signal cable • Limited to ≤ 12 Vdc with maximum current draw of 0.012 amps. Customer must install a 1 K Ω resistor in series with input signal. • Visual indication only, no audible Monitoring Points • Airflow exhaust device command • Actual exhaust airflow • 0-10 Vdc alarm: • 0 Vdc indicates normal operation • 5 Vdc indicates incorrect airflow • 10 Vdc indicates low differential static pressure • Sash position: 0-10 Vdc • User status • 10 K Ω minimum input impedence for monitoring system Backward Compatibility X30 Series Fume Hood Monitors are backward compatible with earlier standard models of Phoenix fume hood monitors. Readout (FHM631 only) The display shows one of the following measurements: • Cubic feet per minute (CFM) • Meters cubed per hour (m3 /h) • Liters per second (l/s) • Feet per minute (fpm) • Meters per second (m/s) FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. Power Loss Alarm Option (±15 Vdc powered monitor only) Indicates loss of power to the fume hood system. • During power failure, a red LED flashes once every 4 sec • Accompanied by short audible alarm “chirp” • Alarm continues for at least 64 hours or until power is restored Dimensions 4.75" W x 4" H x 4.75" D (121 mm x 102 mm x 121 mm) Color • Black enclosure • Yellow switch Operating Range 32-122 °F (0-50 °C) ambient Power Requirements ±15 Vdc @ 0.015 amp More details on this option are in the "Features" section on page 2. If the X30 Series Fume Hood Monitor is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. ! See wiring diagrams ORDERING GUIDE X30 Fume Hood Monitor (631 model shown). Standard Operation Flow Alarm Emergency Exhaust Mute Standby Operation BASE NUMBER TYPE OF FUME HOOD MONITOR 430 = Base monitor, EXV applications 530 = CVV, PEV or BEV applications 631 = Face velocity monitor, EXV applications FACEPLATE LANGUAGE DAN = Danish GER = German ENG = English JPN = Japanese FRC = French Canadian NOR = Norwegian FRN = French SWE = Swedish OPTIONS DFT = Drive failure text (FHM430 only) DIV = Diversity LED to be driven by external contact closure from a Celeris system or the BMS. PLA = Power Loss Alarm (±15 volt only; see note below) PRI = Primary (Available only on FHM430. Must be ordered with at least one secondary.) RET = Retrofit kit RMT= Recess mount kit SEC = Secondary (Available only on FHM430. Must be ordered with primary.) NOTE: By ordering the add-on option “PLA,” you will receive a separate Power Loss Alarm board and box that also mounts on top of the hood. This board interfaces to an X30 Series Fume Hood Monitor that includes an additional red LED with "Power Failure Alarm" text. This unit can be installed on DC-powered monitors only. FHM – – TABLE OF CONTENTS Specifications and Ordering Guide.............................1 Features......................................................................2 Applications: Hood Control.......................................4 Applications: Energy-saving........................................5 Installation .................................................................6 Points and Wiring ......................................................9 Maintenance and Troubleshooting ...........................14
2.
2 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 FEATURES Standard Operation Flow Alarm Emergency Exhaust Mute Standby Operation Power Failure Alarm Diversity Alarm Face Velocity or Flow Display—Indicates the face velocity or flow of the hood. (Available only on the FHM631.) Standard Operation LED—When this LED is on, it indicates the hood is operating at the standard face velocity or flow. Standby Operation LED—When this LED is on, it indicates the hood is operating at a lower face velocity or flow (active only with a ZPS). Flow Alarm/Drive Failure LED—Indicates unsafe airflow condition when it is on. Mute button—Push the button to silence an alarm. The Flow Alarm LED will remain on. Mute mode is reset when the alarm conditions clear. Emergency Exhaust button with LED—Push this button to activate the emergency exhaust mode. The alarm will sound and the LED at the left of the Emergency Exhaust button will blink. In this mode, exhaust air is at its maximum flow. (NOTE: On constant volume hoods, this button is used only to test the alarm circuit, not modulate the exhaust valve.) Push the button again to turn off the emergency exhaust/test mode. Light sensor—Detects the light level in the room. Triggers the energy waste alert, if configured. (Available only on the FHM631.) OPTIONAL FEATURES Diversity Alarm LED—Alerts lab users to reduce the total flow by closing their sashes. This visual alarm is triggered when the flow demand exceeds the flow limit and a diversity alarm is generated by the Celeris system or the BMS. Power Failure Alarm LED—Activates when there is a loss of power. Used in conjunction with the Power Loss Alarm (PLA). With this option, a separate PLA module is provided with the monitor. The optional PLA circuit: • Has a sealed lead acid battery that uses +15 Vdc to recharge the battery while the system is powered. The battery recharges enough in 8 hours to power the alarm circuit for 24 hours. The battery’s expected service life is five years. • Detects the loss of ±15 Vdc system power. Not available for 24 Vac powered monitors. • Trips a solid-state relay that causes the battery to provide power to the monitor’s alarm circuit. • Drives the audible alarm and LED on the monitor to indicate loss of power. The DIN standard requires PLAs on fume hood monitors, as well as periodic functional testing. Therefore, we provide a test button on all PLA option enclosures. Units can be tested by pushing and holding the test button for at least four seconds. This cuts the system’s power, trips the relay and tests the battery and alarm circuitry. No other maintenance is required. NOTE: The PLA must be powered by the same ±15 Vdc that powers the monitor.
3.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—3 OF 16 FEATURES (CONTINUED) FEATURE/OPTION DESCRIPTION CV Two- position VAV FHM530 (CVV) FHM530 (PEV or BEV) FHM430 (EXV) FHM631 (EXV) FACEPLATE* Face velocity display Displays the current face velocity setting in either English or metric units. Operating mode LED Specifies use of hood. Emergency exhaust LED Indicates that the emergency exhaust has been activated. ** Caution flow alarm Alarm due to either pressure alarm, valve jam alarm failure. Spare or Diversity LED Customer specified LED (spare) or diversity alarm condition has been initiated. †‡ †‡ †‡ †‡ Emergency exhaust button LED Emergency exhaust button has been pushed. Setback LED Setback mode has been activated. Power loss LED Power loss mode has been activated. † † † † Emergency exhaust override button Provides a means of activating the emergency exhaust. Mute button Provides a means of muting the audible alarms. Light sensor Activates energy waste alert. CONTROL N.O. microswitch input Activates the two-state command to the valves. Sash position input Activates the two-state or variable air volume (VAV) command to the valves. Sash opening alarm setting Sets the sash height alarm set point. Two-position switch point setting Sets the trip point for the two-state command operation. Standby mode input (e.g., ZPS) Activates standby mode. Switch input Activates decommission mode. Emergency exhaust (locally or remotely) Ability to activate emergency exhaust with digital input. *** VAV hood exhaust command output Command output to the exhaust source (valve). VAV drive command output Command output to a fan drive. 24 Vdc relay output two-position mode 24 Vdc relay output to command 24 Vdc solenoids for two- position application. Primary-secondary option (e.g., teaching hood) Configures monitor for either primary or secondary control of a teaching hood. † Standby velocity setting Sets the standby mode velocity. Auto alarm mute Audible alarms will mute automatically after 20 seconds when this function is enabled. Mute duration setting Allows for resounding audible alarms after the Mute function has been activated. Adjustable from 1-10, 15, or 20 minutes. Sound volume setting Adjust the sound volume. Two settings are available: high and low. Power loss alarm Allows for power loss module that will display power loss alarm when the monitor has lost main power (±15 Vdc only). † † † † Spare LED control User-defined LED that can be engaged externally by means of a digital input. † † † † Broken sash alarm Alarm is generated when the sash sensor’s signal cable has been broken or when a vertical sash sensor (VSS110) retracting cable has detatched. ±15 Vdc or 24 Vac power May be powered by either AC or DC voltage. MONITORING Hood exhaust command/emergency exhaust 0-10 Vdc signal represent command or > 10 Vdc represents activation of emergency override. Hood exhaust feedback 0-10 Vdc scaled feedback signal. Alarm signal 0, 5, or 10 Vdc alarm signal generated at the valve can be monitored at the fume hood monitor. Normally open (NO) alarm relay NO contact output that de-energizes during alarm condition. Sash position 0-10 Vdc signal proportionally represents sash position from fully closed to fully open. Hood decommissioned Monitors hood decommission command. User status Monitors Zone Presence Sensor’s (ZPS’) activity. * Faceplates are available in English, Danish, French Canadian, French, German, Japanese, Norwegian and Swedish. ** Does not modulate exhaust CV valve, but allows the operator to test the alarm circuit. *** Cannot use this external input with decommission mode via the external switch or BMS command. † Options ‡ Contact your representative to communicate details.
4.
4 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 APPLICATIONS: HOOD CONTROL Variable Air Volume (VAV) Fume Hoods (FHM430 and 631) Fume hood containment is accomplished by maintaining proper face velocity through the variable sash opening. Phoenix Controls fume hood monitors can be used on manifolded exhaust systems (with Phoenix Controls valves) and on individual exhaust systems (with a variable speed drive by others). Functions • Constant face velocity control—The goal is to maintain a constant face velocity (FV) as the sash opening varies. Since the FV set point is known, a change in sash area causes a linear change in exhaust flow (FV x Area = Flow command). Example: 5 ft2 x 100 ft/min = 500 ft3 /min (or 0.5 m2 x 0.5 m/s x 3600 s/hr = 900 m3/hr) • Setback of face velocity—Under many conditions, the face velocity can be set back to provide safe containment when the hood area is vacated. Setback face velocity is adjustable to field conditions—typically between 60-100 fpm (or 0.3-0.5 m/s). (See the Zone Presence Sensor Product Data Sheet for more details.) • Alarms—The FHM430 and 631 monitors provide indication of a fume hood’s operation. Alarms include: • Insufficient differential static pressure as detected by the valve’s pressure switch • Incorrect airflow alarm (sash command ≠ closed-loop feedback) Hood exhaust valve 200-1000 CFM Sash sensor To manifold Variable speed drive 200-1000 CFM Sash sensor Individual exhaust Fume hood containment—valve system. Standard Operation Flow Alarm Emergency Exhaust Mute Standby Operation Variable Air Volume (VAV) Standard Operation Flow Alarm Emergency Exhaust Mute Standby Operation Fume hood containment—individual exhaust systems. Variable Speed Drive FV set point Hi select Exhaust flow command Sash Sensor (position) Area Zone Presence Sensor (operator status) Reset FV Flow command FV x Area = Flow command Emergency exhaust override Alarm circuit Alarm status from valve or drive Fume Hood Monitor VAV fume hood monitor signal flow diagram.
5.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—5 OF 16 APPLICATIONS: HOOD CONTROL (CONTINUED) Constant Volume (CV) and Two-state Fume Hoods (FHM530) A Phoenix Controls (constant volume) CVV series airflow control valve provides the fume hood with a steady constant exhaust flow, independent of duct pressure changes. The two-state airflow control valve (PEV or BEV series) provides two-position exhaust control based on an operator’s presence at the fume hood. Functions • Alarm—The FHM530, together with a differential pressure switch mounted on a Phoenix Controls airflow valve, indicates a fume hood’s operation. An optional sash opening alarm may be used with a sash sensor or sash switch. • Two-position control—The FHM530, together with a Zone Presence Sensor and a Phoenix Controls PEV or BEV series airflow control valve with an on- board solenoid, provides two- position exhaust control based on an operator’s presence at the fume hood. Other switching mechanisms, such as a sash sensor or sash switch, may be applied. APPLICATIONS: ENERGY-SAVING Face Velocity Setback (FHM430, 530, and 631) Under many conditions, the face velocity can be set back to provide safe containment when the hood area is vacated. Setback face velocity is adjustable to field conditions—typically between 60-100 fpm (or 0.3-0.5 m/s). (See the Zone Presence Sensor Product Data Sheet for more details.) Energy Waste Alert (FHM631) The FHM631 is equipped with an energy waste alert, indicating the sash is open and the room is dark (adjustable light intensity level). The display shows "ENRG," and an audible alarm sounds until the sash is closed or the lights are illuminated. Fume Hood Decommissioning Mode (FHM631)* The fume hood decommissioning mode on the FHM631 allows a fume hood to be decommissioned when it is not in use and the sash is fully closed. The exhaust flow is reduced below the fume hood’s minimum to the valve’s minimum flow (e.g., 90 CFM for a 12-inch valve), and the display shows "OFF." This mode can be initiated in one of three ways: 1. Through pushbuttons on the monitor’s faceplate. Press and hold the Emergency Exhaust and Mute buttons for three seconds. The display will flash "OFF?" Confirm by pressing the Mute button. 2. Through the external momentary switch (by others) 3. Through the BMS network command The mode is exited automatically when the sash is opened. * NOTES: • Decommission mode cannot be used in drive applications. • Proper standard operating procedures (SOPs) must be in place to remove all chemicals from the fume hood before it is decommissioned. Fume hood exhaust valve 600/1000 CFM Zone Presence Sensor Fume hood exhaust valve 1000 CFM FHM530 (typical) To manifold To manifold Pressure switch Fume hood alarming and control—constant volume and two-state. Standard Operation Flow Alarm Emergency Exhaust Mute Standby Operation Constant Volume (CV) Two-state
6.
6 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 INSTALLATION The X30 Fume Hood Monitor Series is available with two mounting options: surface and flush. Surface Mount Option Required materials: • Fume hood monitor, X30 series • Phoenix Controls room wiring diagrams • Two zinc-plated hex washer head slotted sheet metal screws, Type A Installation steps: 4. Use the mounting template to mark the points for attaching the fume hood monitor to the fume hood (see Figure 1). 5. Unsnap the front cover from the monitor: • Loosen the bottom of the monitor housing and rotate it slightly upward. • Gently slide the enclosure up to release the two tabs inside the top of the monitor housing from the two grooves on the monitor base. 6. Set the monitor housing aside. 7. Using the enclosure base as a template, mark the mounting holes at both ends. Be certain the fume hood monitor assembly is oriented as indicated in the figure on the right. Set the enclosure base aside. 8. Drill pilot holes at the marked mounting holes. 9. Mount the monitor base to the fume hood using two sheet metal screws (see Figure 2). 10. Run the cable through the mounting plate and strip back the conductors. 11. Remove the connectors from the monitor housing. 12. Complete the terminations to the connectors (refer to the wiring diagrams provided). 13. Reinstall the connectors in the monitor housing. 14. Reattach the monitor housing to the monitor base (see Figure 3): • Insert the two tabs at the top of the monitor housing in the grooves at the top of the monitor base. • Rotate the monitor housing downward and snap the bottom of the cover onto the tabs in the monitor base to secure it. Figure 1. Fume Hood Monitor mounting template (surface mount). 5" (12.7 cm) 1.2" (3.05 cm) Completed enclosure base with labels applied Pilot hole (typical of 2) (.2" dia. each/.5 cm) .75" dia. (1.9 cm) Extents of monitor 6" x 2.5" (15.24 x 6.35 cm) 5" (12.7 cm) Date Init'l Face Vel Sash Hght Min Flow Max Flow Standby Flow Flow S-F 601-000-030 LBLLabel/SerialW/CE-USA .625" (1.59 cm) Figure 2. Attaching the Fume Hood Monitor to the fume hood (surface mount). Slide enclosure cover onto top of enclosure base.Then rotate cover onto lower tabs for a secure fit.Date In it'l Fac eVel Sas hHght M in Flo w M ax Flo w StandbyFlow Flo w S-F 601-000-030 LB L Label/Seria lW /C E-U SA Sta ndard Operation FlowAla rm Em erg enc yExhau st Mute Figure 3. Reattaching the Fume Hood Monitor monitor housing to the base.
7.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—7 OF 16 INSTALLATION (CONTINUED) Recess Mount Option Required materials: • Fume hood monitor, X30-RMT series (includes recess mounting bracket and screws) • Phoenix Controls room wiring diagrams • Cable, based on wiring diagram (not provided by Phoenix Controls) Installation steps: 1. Use the recess mounting template to mark the area for cutout and mounting holes for attaching the fume hood monitor to the fume hood (see Figure 4). 2. Cut a square hole, as necessary, for the recess mounting kit. 3. Mark the holes for mounting the bracket: • Using the recess mounting bracket as a template, place the bracket in the cutout section of the fume hood and mark locations of holes required for attaching the bracket to the fume hood. • Set the bracket aside. 4. Drill .125" (.32 cm) pilot holes for mounting screws. 5. Unsnap the front cover from the monitor base: • Loosen the bottom of the monitor housing and rotate it slightly upward. • Gently slide the enclosure cover up to release the two tabs inside the top of the monitor housing from the two grooves on the monitor base. 6. Set the enclosure cover aside. 7. Run the cable through the back of the monitor base. 8. Remove the connectors from the monitor housing. 9. Complete the terminations to the connectors (refer to provided wiring diagrams). 10. Reinstall the connectors in the monitor housing. 11. Attach the enclosure cover to the monitor base: • Insert the two tabs at the top of the enclosure cover in the grooves at the top of the monitor base. • Rotate the enclosure cover downward and snap the bottom of the cover onto the tabs in the monitor base to secure it. 12. Attach the monitor to the recess mounting bracket (see Figure 6 on the next page): • Slide the monitor assembly into the mounting bracket from the back. • Insert the L-strap into the top slot on the recess mounting bracket as shown. • Rotate the L-strap and slide it downward through the bottom slot in the recess mounting bracket. 2.6" (6.6 cm) 6.25" (15.88 cm) 6.8" (17.27 cm) Pilot hole (typical of 2) (.125" dia. each/.32 cm) 3.25" (8.26 cm) 7.5" (19.05 cm) 1.9" (4.83 cm) Figure 4. Fume Hood Monitor mounting template (recess mount). Figure 5. Attaching the Fume Hood Monitor to the fume hood (recess mount).
8.
8 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 INSTALLATION (CONTINUED) Recess Mount Option (continued) 13. Mount the monitor and bracket assembly to the fume hood (see Figure 5 on the previous page): • Slide the assembly into the cutout area. • Using the mounting screws provided, attach the bracket to the fume hood. Retrofit Jobs Required materials: • Fume hood monitor, X30 series (includes recess mounting bracket assembly and screws) • Phoenix Controls room wiring diagrams • Cable, based on wiring diagram (not provided by Phoenix Controls) Installation steps: 1. Use the existing monitor to cut out hole and screw pilot holes from the previous FHM X10 Series monitor installation. Ensure that the dimensions of the cutout and mounting holes match those given here (see Figure 7). 2. Follow steps 5-12 from the standard Recess Mount installation procedure above. 3. Mount the monitor and bracket assembly to the fume hood (see Figure 8): • Slide the U-nut (included) over the existing mounting holes with the spring side inward. • Slide the assembly into the cutout area. • Using the mounting screws provided, attach the bracket to the fume hood. Phoenix Controls Wiring Recommendations • The fume hood monitor and exhaust valve should be powered from the same source. • If control over the fume hoods is important during a power failure or if airflow conservation is required, fume hood monitors should be placed on backup power; otherwise, the fume hood valve defaults to its fail-safe state. • Use cables recommended by Phoenix Controls. • Stranded wire is strongly recommended for ease of installation. • Follow good wiring practices: • Do not run the signal cable in the same conduit or wireway as the power cables. • If the signal cable must cross power cables, it is best to do so at a 90-degree angle. • Shield or drain wires, if required, should be wrapped with insulating tape to prevent contact with exposed conductors or contacts. • Maintain a consistent color code or polarity all the way through the wiring system. • All connections to the Celeris valve controller (LVC) must meet the requirements of an NEC Class 2 circuit. • Local and national electrical codes take precedence. L-strap Figure 6. Attaching the Fume Hood Monitor to the recess mounting bracke 8.13" (20.65 cm) 9.38" (23.83 cm) 2.5" (6.35 cm) 3.25" (8.26 cm) 10.5" (26.67 cm) 9.38" (23.83 cm) Figure 7. Fume Hood Monitor mounting template (retrofit jobs). U-nut Figure 8. Attaching the Fume Hood Monitor to the fume hood (retrofit jobs).
9.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—9 OF 16 POINTS AND WIRING (see submittal wiring diagram for project-specific details) J2 TB1 TB2 TB4 1 1 1 TB3 1 FHM430/631 To fume hood exhaust valve (See note 1) VSS110 Zone Presence Sensor (ZPS) 200 Series 1 2 3 4 5 6 7 8 TB1 TB2 1 2 3 4 5 6 7 7 6 5 4 3 2 1 TB1 To TB1-2 To TB1-7 Reel Sensor Red Black ISO Ground Not Used User Status Secondary In Not Used Ground +15 Vdc/24 Vac 3 2 1 TB4 From AC Power Supply 24VacH 24VacN 8c (See note 2) Notes: 1. Eight-conductor wire is Belden 9421 (22 AWG) or equivalent. (Tape back unused conductors.) 2. Sash sensor is provided with two-conductor cable. See combination sash sensors for exception. FHM430 and 631 Typical Wiring Diagram Monitor Termination Points Variable Air Volume (VAV) Application TERMINAL BLOCK POINTS 1 2 3 4 5 6 7 8 TB1 +12 Vdc Analog Ground External Emergency/ Decommission Input Command Feedback Tri-level Alarm User Status Sash Signal TB2 Sash Sensor Analog Ground — Decommission Output Power Loss Input Spare LED (+) Spare LED (-) — TB4 24 Vac H/ +15 Vdc Functional Ground 24 Vac N/ -15 Vdc — — — — — ! See pages 12-13 for DC wiring details, as well as the wiring of options and ancillary equipment.
10.
10 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 POINTS AND WIRING (CONTINUED) (see submittal wiring diagram for project-specific details) J2 TB1 TB2 TB3 TB4 J1 1 1 1 1 Note: Requirements for transformers: • Secondary power shall be fused externally to current limit of 4 amps, in accordance with NEC CL2 power requirements. Thermal interrupts are not recommended. • Do not earth ground secondary transformers. • Maximum cable length for 96 VA load is 110’. • Each pressurization zone shall have a dedicated single-phase primary circuit or a secondary circuit disconnect. FHM530 Monitor Termination Points Constant Volume Application COMPONENTS TERMINAL BLOCK POINTS Device Function J1 IN for DC solenoid OUT for AC solenoid 1 2 3 4 5 6 7 8 TB1 +12 Vdc Analog Ground External Emergency NOV Command NCV Command Pressure Switch User Status Sash Signal TB2 Sash Sensor Analog Ground — — Power Loss Input Spare LED (+) Spare LED (-) — TB3 Solenoid Command Common Alarm NO Alarm Common — — — — — TB4 24 Vac H/ +15 Vdc NOV/NCV Common Functional Ground 24 Vac N /-15 Vdc — — — — — Phoenix Constant Volume Venturi Valve FHM530 From AC Power Supply 24VacH 24VacN TB1 1 2 3 4 5 6 7 8 3 2 1 TB4 Pressure Switch NO COM P ! See page 12 for DC wiring details, as well as the wiring of options and ancillary equipment.
11.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—11 OF 16 POINTS AND WIRING (CONTINUED) (see submittal wiring diagram for project-specific details) AC Solenoid Valve Pressure Switch Phoenix Two-state Venturi Valve To TB1-4 (-) To TB4-1 (+) 1 2 3 To TB1-2 (NO) To TB1-6 (COM) P I 3 2 1 TB3 FHM530 From AC Power Supply (See note 2) 24VacH 24VacN TB1 1 2 3 4 5 6 7 8 3 2 1 TB4 Zone Presence Sensor (ZPS) 200 Series 7 6 5 4 3 2 1 TB1 To TB1-2 To TB1-7 ISO Ground Not Used User Status Secondary In Not Used Ground +15 Vdc/24 Vac J1 OUT See note 1 DC Solenoid Valve Pressure Switch Phoenix Two-state Venturi Valve To TB1-4 (-) To TB1-1 (+) 1 2 3 To TB1-2 (NO) To TB1-6 (COM) P H 3 2 1 TB3 FHM530 From DC Power Supply (See note 2) +15Vdc GROUND TB1 1 2 3 4 5 6 7 8 3 2 1 TB4 Zone Presence Sensor (ZPS) 200 Series 7 6 5 4 3 2 1 TB1 To TB1-2 To TB1-7 ISO Ground Not Used User Status Secondary In Not Used Ground +15 Vdc/24 Vac J1 IN -15Vdc Notes: 1. For AC-powered solenoid, two-position applications, you must install a field jumper between TB3-1 and TB4-3 (not required for DC- powered solenoids). 2. AC solenoids require the fume hood monitor to have AC power. DC solenoids require the fume hood monitor to have DC power. FHM530 (continued) Two-state Application: AC Solenoid Two-state Application: DC Solenoid ! See page 12 for the wiring of options and ancillary equipment. See page 12 for the wiring of options and ancillary equipment.
12.
12 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 POINTS AND WIRING (CONTINUED) (see submittal wiring diagram for project-specific details) Wiring of Options and Ancillary Equipment for X30 Fume Hood Monitor Series FHM430 Primary/Secondary Wiring (for AC-powered units) FHM430 Primary/Secondary Wiring (for DC-powered units) FHM430/631/530 External Emergency Override, Method 1 FHM430/631/530 External Emergency Override, Method 2 FHM430/631/530 Power Loss Alarm FHM430/631/530 Optional/Diversity LED FHM530 Alarm Relay Zone Presence Sensor (ZPS100 Series) X30 Series: DC Wiring Details Primary Unit 3 2 1 TB4 From Power Supply 24VacH 24VacN TB3 1 2 3 3 2 1 TB4 24VacH 24VacN TB3 Secondary Unit 2c 1 2 3 Primary Unit From Power Supply Secondary Unit TB2 1 2 3 4 5 6 7 3 2 1 TB4 +15 GROUND -15 TB3 1 2 3 TB3 2c 1 2 3 TB2 1 2 3 4 5 6 7 3 2 1 TB4 +15 GROUND -15 FHMX30 Contact Closure (provided by others) 1 2 3 4 5 6 7 8 TB1 2c FHMX30 1 2 3 4 5 6 TB1 10-volt command from BMS to initiate emergency override 2c Power Loss Alarm Unit 1 2 3 4 TB1 To FHMX30 Monitor To TB4-1 To TB2-2 To TB4-3 To TB2-5 4c +15 Ground -15 Output NOTE: The Power Loss Alarm unit will work only if powered by the same DC power source serving the monitor. AC-powered monitors cannot have a Power Loss Alarm. FHMX30 1 2 3 4 5 6 7 8 TB1 TB2 1 2 3 4 5 6 7 2c Contact Closure (provided by others) 1 K Ohm Resistor (provided by others) FHM530 1 2 3 TB3 To BMS for monitoring purposes NO COM ZPS110 7 6 5 4 3 2 1 TB1 To FHM X30 Monitor To TB4-3 To TB1-2 To TB4-1 4c Sync Out Sync In User Status Secondary -15 Ground +15 To TB1-7 NOTE: ZPS100 series units can be powered by only DC voltage. If the FHM X30 is powered by AC, then separate power must be brought to the ZPS100 unit. TB2 1 2 3 4 5 6 7 3 2 1 TB4 From DC Power Supply +15 GROUND -15
13.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—13 OF 16 POINTS AND WIRING (CONTINUED) (see submittal wiring diagram for project-specific details) Decommission Mode Wiring for FHM631 (in addition to the wiring shown on page 9) Decommission Mode through the Fume Hood Monitor’s Pushbutton Decommission Mode through a Momentary External Switch Decommission Mode through a BMS Command* TB2 1 2 3 4 5 6 7 GROUND Celeris Valve Controller (LVC) 1 2 3 4 5 6 7 8 TB1 FHM631 DIGITAL OUT1 DIGITAL IN+ DIGITAL IN- 8c GROUND Celeris Valve Controller (LVC) 1 2 3 4 5 6 7 8 TB1 FHM631 DIGITAL OUT1 DIGITAL IN+ DIGITAL IN- EXTERNAL SWITCH 8c 2c 1 2 3 4 5 6 7 8 TB1 TB2 1 2 3 4 5 6 7 +12 V +12 V Celeris Valve Controller (LVC) 1 2 3 4 5 6 7 8 TB1 FHM631 DIGITAL OUT1 DIGITAL IN+ DIGITAL IN- TB2 1 2 3 4 5 6 7 NO COM 2c 1 2 3 4 5 6 7 8 TB1 TB2 1 2 3 4 5 6 7 GROUND 8c *Note: Do not use this configuration if the LVC and fume hood monitor are using separate power sources.
14.
14 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 MAINTENANCE Phoenix Controls fume hood monitors require no ongoing preventative maintenance. Once the field engineer has completed the field setup, the monitors will provide years of continuous operation. TROUBLESHOOTING Phoenix Controls fume hood monitors alert the operator of alarm conditions. Generally, this alarm is caused by a problem condition in the exhaust duct (e.g., fan failure). A trained facilities person may troubleshoot the system from the monitor with a digital voltmeter and perhaps a magnehelic gauge. Alarms The types of alarms for the X30 Series Fume Hood Monitor, the audible and visual cues for each alarm, and the purpose for each alarm are listed in the table below. Replacement Part Part Number FHM631 board 860-200-108 FHM630 board 860-200-102 FHM530 board 860-200-109 FHM430 board 860-200-111 FHM430 primary board 860-200-110 FHM430 secondary board 860-200-112 X30 recess mount retrofit kit (replaces X10 models with X30) 260-270-004 X30 recess mount kit 260-270-005 Type of Alarm Alarm Indicators Reason for AlarmVisual Alarm (LED blink rate*) Audible Alarm (beep rate**) Signals (as seen in analog valve systems) Not commissioned Standard Operation—Fast Flow Alarm—Fast 631 Display—Er-c None N/A The unit requires commissioning. Low differential static pressure Flow Alarm—Slow FHM631 display—Blank Fast TB1, 6 = 10 Vdc The hood’s pressure switch is open (FHM631 and 430 only). Flow Alarm—Slow Fast N/A The hood’s pressure switch is open (FHM530 only). Incorrect airflow (i.e., valve jam) Flow Alarm—Fast Slow TB1, 6 = 5 Vdc The valve’s position is jammed (FHM631 and 430 only). Sash opening alarm Flow Alarm—Slow Slow TB1, 6 = 0 Vdc*** The sash opening exceeds the calibrated alarm set point. Broken sash sensor alarm Flow Alarm—Fast Fast TB1, 6 = 0 Vdc*** TB1, 8 > 10.4 Vdc The sash input is greater than the maximum resistive input for the application, or the sash sensor signal cable is broken or loose. Emergency exhaust override alarm (local) Emerg Exh—Slow Slow TB1, 6 = 0 Vdc TB1, 4 > 10.4 Vdc The emergency exhaust button was pushed. Emergency exhaust override alarm (BMS external) Emerg Exh—Fast Slow TB1, 6 = 0 Vdc*** TB1, 4 > 10.4 Vdc The externally controlled emergency input is in emergency state. Energy waste alert FHM631 display—ENRG Slow N/A The sash is open and room lights are off (FHM631 only). Power fail alarm Power loss LED on every 4 seconds 3 beeps every 10 seconds N/A The fume hood monitor lost ±15 Vdc power. Optional alarm Optional alarm LED driven by customer None TB1, 6 = 0 Vdc Customer specific alarm or diversity alarm Loss of alarm line Flow Alarm—Slow 631 Display—Blank Fast TB1, 6 = 12 Vdc The alarm signal cable is broken. Loss of feedback signal Standard Operation—Solid Flow Alarm—Slow 631 Display—Low value Slow TB1, 6 = 0 Vdc Feedback signal cable is broken. Notes: * A fast blink rate resembles a flashing light, while a slow rate resembles a fluttering light. ** A fast beep rate is 10 beeps per second, while a slow rate is 2 beeps per second. *** 5 Vdc will be detected when these alarms are generated by a Celeris system. If the fume hood monitor generates this condition first, the Celeris signal will supercede after it is generated.
15.
©2005 Phoenix Controls
Corporation. Specifications subject to change without notice. Rev. 9/07 MKT-0044 MPC-1093 X30 SERIES FUME HOOD MONITORS—15 OF 16 TROUBLESHOOTING (CONTINUED) Troubleshooting Guide Use the information in the tables below to troubleshoot the X30 Series Fume Hood Monitor. Variable Air Volume (VAV) Valve Systems (FHM430 and 631 only) Constant Volume (CV) and Two-state Valve Systems (FHM530) Problem at Fume Hood Monitor Voltage at TB1-6 in Monitor Possible Cause/Solution 1. The monitor is in flow alarm. > 10 V 5 V Voltages may vary. A. Low static pressure across valve • Loss of airflow—Check fan operation and duct blockage. • Too many sashes open at one time—Close sashes. • Valve failed open—Check pneumatic and mechanical connections. B. Incorrect valve position • Valve failed open. • Sash open beyond the maximum allowable position—Lower sash. • A broken sash cable—Check all sash sensor connections. C. Equipment/connection problems • Blocked or kinked pressure switch tubing—Correct tubing. • Wiring terminations between monitor and control device—Correct terminations. • Malfunctioning alarm circuits—Verify proper static.* • Monitor miscalibration—Recalibrate.* 2. The monitor indicates normal operation, but the actual face velocity has been measured high or low. 0 V A. Low static pressure • Differential pressure between the pressure switch set point and the low end of the static pressure operating range [i.e., 0.3" and 0.6" wc (75-150 Pa) for medium pressure valves] will not trip the alarm circuit. • Measure differential pressure. If it is low, see Possible Cause/Solution 1A above. B. Monitor miscalibration—Recalibrate.* 3. The monitor has malfunctioned. • No display. • Cannot mute alarm. Voltages may vary. A. Loss of power • Check power at monitor TB4-1 (24 Vac H/+15 Vdc) and TB4-3 (24 Vac N/-15 Vdc). • Check wiring connections at monitor, valve, and power supply. • Verify power supply has input voltage (120 Vac or 240 Vac). B. Defective monitor—Replace board on monitor.* 4. The flow remains constant through sash travel. A. Broken sash sensor cable—Replace sensor. B. Monitor miscalibration—Recalibrate.* * Contact Phoenix Controls Product Support Center for assistance. Problem Possible Cause/Solution 1. The monitor is in flow alarm. Low static pressure across valve. • Loss of airflow. Check fan operation and duct blockage. • Blocked or kinked pressure switch tubing. Correct the tubing. 2. The airflow was measured improperly in a: A. Constant volume system. B. Two-position system. A. Incorrect valve position. Realign the pivot arm. B. Incorrect valve position. Check pneumatic tubing and pressure. Also check solenoid valve operation.
16.
16 OF 16—X30
SERIES FUME HOOD MONITORS MKT-0044 MPC-1093 ©2005 Phoenix Controls Corporation. Specifications subject to change without notice. Rev. 9/07 TROUBLESHOOTING (CONTINUED) Variable Air Volume (VAV) Drive Systems (FHM430 and 631 only) Energy-saving Options (FHM631 only) Problem Possible Cause/Solution 1. The monitor is in flow alarm. A. Loss of airflow • Check fan operation and duct blockage. • Check the drive for proper operation. B. Monitor/connection problems • The wiring terminations between monitor and control device are incorrect. Correct the terminations. • The monitor was miscalibrated. Recalibrate the monitor as needed.* • The monitor is defective. Replace the board on the monitor.* 2. The monitor indicates normal operation, but actual face velocity has been measured high or low. The monitor was miscalibrated. Recalibrate the monitor as needed.* 3. The monitor is malfunctioning. • No display • Cannot mute alarm A. Loss of power • Check the wiring connections at the monitor, drive and power supply. • Verify that the power supply has input voltage. • Check power at the monitor. B. The monitor is defective. Replace the board on the monitor. Recalibrate the monitor as needed.* * Contact Phoenix Controls Product Support Center for assistance. Problem Possible Cause/Solution 1. The monitor will not enter energy waste alert. A. The low-light level setting is too high. Recalibrate the monitor. B. The energy waste alert is not enabled. Recalibrate the monitor. 2. The monitor will not exit energy waste alert. The high-light level setting is too high. Recalibrate the monitor. 3. The monitor will not enter decommission mode. A. The sash is not fully closed. Close the sash. B. Decommission mode is not enabled. Recalibrate the monitor. C. Check the wiring to the valve. 4. The monitor will not exit decommission mode. A. The digital input (DI) on the valve is not configured properly. Reconfigure this input. B. The monitor is defective. Replace and recalibrate the monitor.
Télécharger maintenant