1% of reading value effectively ensures the accuracy of test results
2 independent test modes are available, including tensile strength and peeling force to meet the distinct requirements of users
3 kinds of testing data provided for each test i.e. Maximum Value, Minimum Value and Average Value. Group data analysis is also available.
1. PARAM® XLW (B) Auto Tensile Tester
Yarina Gao trade5@labthink.cn
Professional Technology
1% of reading value effectively ensures the accuracy of test results
2 independent test modes are available, including tensile strength and
peeling force to meet the distinct requirements of users
3 kinds of testing data provided for each test i.e. Maximum Value,
Minimum Value and Average Value. Group data analysis is also
available.
Deformation rate could be easily obtained by the elongation and elongation rate ruler
Different test range of load cells and 7 distinct test speeds to meet different test requirements
The instrument is controlled by micro-computer with menu interface, PVC operation panel and large LCD
display
Intelligent designs of over-travel protection, overload protection, automatic position reset and error alert for
safe test operation
Equipped with RS232 port and micro printer port which is convenient to the data transmission and PC
connection
Professional operating software supports statistical analysis of group specimens, superposition analysis of
test curves and historical data comparison functions as well as multi-functions of parameter set, printing,
inquiry, clear and calibration, etc
Support Lystem™ Lab Data Sharing System for uniform and systematic data management
Applications
This instrument is equipped with more than 100 grips for tests of more than 1000 materials. And customization is
also available for special material tests. Examples of instrument applications:
Basic
Applications Extended Applications
Puncture Test of Puncture/Pullout
Puncture Test of Puncture Test of
Shearing Test Hypodermic Needles Test of Flexible
Films Infusion Bags
in Artificial Skin Rubber Closures
Test of Tensile Opening Resistance Puncture/Pullout
Tear Test of ZD -Type Opening Force Test
Strength and Test of Combined Test of Oral Liquid
Caps of Oral Liquid Caps
Elongation Rate Covers Caps
90 Degree Pullout Puncture/Pullout
Test of Tensile Pullout Test of 23 Degree Pullout
Test of Infusion Bag Test of Bottle Caps
Strength at Break Infusion Bag Caps Test of Bottle Caps
Caps or Rubber Closures
Tear Resistance Test 90 Degree Peel Test
Tear Resistance 90 Degree Peel Test Tear Resistance Test
of Adhesive Binding of Water-soluble
Test of Adhesive Tapes of Adhesives
Books Plasters
Heatseal Strength Adhesive Strength Adhesive Strength Peel Test of Flexible Removal Force of
Test Test (soft) Test (hard) Tube Caps Pipes and Pipe Joints
90 Degree Peel Pullout Test of Pullout Test of Tooth Tensile Strength of Opening Force Test
Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140
w w w.labthinkinter n atio n al.co m.cn
2. Test Cosmetic Brush Hair Brush Hair Ropes at Break of Jelly Cups and
Yogurt Cups
45 Degree Peel Test
180 Degree Peel Peel Test of Cup Pullout Test of Tensile Strength of
of Bottle
Test Films Rubber Stoppers Sealing Bags
Membranes
Peel Test of Magnetic 90 Degree Peel Test Tear Resistance of Separating Force of
Cores of Magnetic Cards Heat Sealing Films Protect Films
Compressive
Peel Test of Release Tear Test Using Unwrapping Force
Resistance of Plastic
Paper Trouser Method of Adhesive Tapes
Bottles
135 Degree Peel Peeling Grips of
20 Degree Peel Test Eccentric Grips
Test of Plugs Floating Rollers
Japanese Sample British Sample
Wide Sample Grips
Grips Grips
Test Principle
The pre-conditioned specimen is mounted between two grips, which move in relative direction during the test.
The signals of force and displacement changes are separately recorded by the load cell fixed on the driven grip
and embedded displacement transducer. The tensile strength, tear strength and elongation rate can be obtained by
further calculation.
This instrument conforms to various standards as follows:
GB/T 4850-2002, GB8808, GB/T 1040.3-2006, GB/T17200, GB/T2790, GB/T2791, GB/T2792, QB/T2358
Technical Specifications
Items Specifications
TestRange 200N(30N, 50N or 100N is optional)
Accuracy 1% of reading value
Test Speed 50, 100, 150, 200, 250, 300, 500 mm/min
Number of Specimens 1
30 mm (Standard Grip)
Specimen Width
50mm (Optional Grip)
Sample Clamp manual
Stroke 600 mm
Instrument Size 450 mm(L) x 580 mm(W) x 1100 mm(H)
Power Supply AC 220V50 Hz
Net Weight 61 kg
Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140
w w w.labthinkinter n atio n al.co m.cn
3. Configurations
Standard Mainbody, Universal Grips, Professional Software, and Communication Cable
Configurations
Sensor, Micro printer, Communication Cable, Standard Pressure Roller, Test Plate, Sample
Optional Parts
Cutter, Low Speed Unwrapping Device, Customized Grips
Labthink Instruments Co., Ltd.144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86 -531-85068566 FAX: +86-531-85812140
w w w.labthinkinter n atio n al.co m.cn