Mechanical Measurement And
Metrology(2141901)
Active Learning Assignment
Topics: Temperature Measurement
Guided By: Prof. Jigar Paghadal
Branch : Mechanical Engineering
Div: 4C2
Submitted by: Saahil R Kshatriya
Enrollment Number: 150120119164
 The means of accurately measuring temperatures has long
fascinated people.
 One of the differences between temperature and other
physical concepts, such as mass or length, is that it is
subjective.
 Different people will have different perceptions of what is hot
and what is cold.
 To make objective measurements, we must use thermometer
in which some physical property of a substance changes with
temperature in a reliable and reproducible way.
Scale
 Temperature is a measure of the thermal energy in the
body. Normally measured in degrees [°]using one of the
following scales.
1. Fahrenheit.[°F]
2. Celsius or centigrade. [°C]
3. Kelvin .[°K]
Temperature measurement

The following characteristics can be used to
measure the temperature

A change in dimentions - expansion or
contraction of material w.r.t. Temp change

A change in electrical resistance of metals
and semi-conductors w.r.t. Temp change

A thermo-electric emf produced due to temp
difference at two junctions of two metal alloy
joined together

A change in intensity and colour of radiation
emitted by the hot body w.r.t to change in
temp
Expansion thermometers

(1)Bimetalic thermometer -solid expansion

(2)Liquid in glass thermometers
Methods of Temperature
Measurement
• Expansion Thermometer
 Bimetallic Thermometer
(Expansion of Solid)
 Liquid in Glass Thermometer (Expansion
of Liquid)
 Liquid in Metal Thermometer (Expansion
of Liquid)
 Gas Thermometer
• Filled System Thermometer
 Liquid filled Thermometer
 Mercury filled Thermometer
 Vapour pressure Thermometer
 Electrical Temperature Instrument
 Resistance Thermometer
 Thermocouple
 Thermistor
 Thermopile
 Electrical Temperature Instrument
 Resistance Thermometer
 Thermocouple
 Thermistor
 Thermopile
 Other Methods of Temperature Measurement
 Quartz Thermometer
 Solid State Temperature Measurement
 Optical Fibre Temperature Measurement
 Ultrasonic Thermometer
1.Bulb: The reservoir for containing most of the
thermometric liquid (mercury).
2.Stem: The glass tube having a capillary bore
along which the liquid moves with changes
in temperature.
3. Scale: A narrow-temperature-range scale for
reading a reference temperature .
Construction
1.Liquid – in – Glass Thermometer
• The volume of mercury changes slightly with
temperature; the small change in volume drives the
narrow mercury column a relatively long way up the
tube.
• The space above the mercury may be filled
with nitrogen or it may be at less than atmospheric
pressure, a partial vacuum.
 Advantages
1) Simplicity in use & low cost.
2) Portable device.
3) Checking physical damage is easy.
4) Power source not require.
Disadvantages
1) Can not used for automatic recording.
2) Time lag in measurement.
3) Range is limited to about 300 °C .
2.Bimetallic Thermometer
In an industry, there is always a need to measure and
monitor temperature of a particular spot, field or
locality.
The industrial names given to such temperature
sensors are Temperature Indicators (TI) or
Temperature Gauges (TG).
All these temperature gauges belong to the class of
instruments that are known as bimetallic sensors.
Bimetallic Thermometer
Two basic principles of operation is to be followed in
the case of a bimetallic sensor.
1) A metal tends to undergo a volumetric dimensional
change (expansion/contraction), according to the
change in temperature.
2) Different metals have different co-efficient of
temperatures. The rate of volumetric change
depends on this co-efficient of temperature.
Construction
• The device consists of a bimetallic strip of two different
metals .
• They are bonded together to form a spiral or a twisted
helix.
• Both these metals are joined together at one end by either
welding or riveting.
• It is bonded so strong that there will not be any relative
motion between the two.
• The image of a bimetallic strip is shown below.
 A change in temperature causes the free end of the
strip to expand or contract due to the different
coefficients of expansion of the two metals.
 This movement is linear to the change in
temperature and the deflection of the free end can be
read out by attaching a pointer to it.
 This reading will indicate the value of temperature.
Bimetallic strips are available in different forms like
helix type, cantilever, spiral, and also flat type.
Construction
 Advantages
1) Power source not required
2) Robust, easy to use and cheap.
3) Can be used to 500 °C.
Disadvantages
1) Not very accurate.
2) Limited to applications where manual reading is
acceptable.
3) Not suitable for very low temperatures because
the expansion of metals tend to be too similar, so
the device becomes a rather insensitive
thermometer
Filled System Thermometer
 Filled system thermometers consist of Bourdon tube, a
capillary tube and a thermometer bulb all interconnected.
 The entire point is sealed after appropriate liquid filling at NTP
and commonly used
liquids are mercury, ethyl alcohol, xylene and toluene.
 Liquid expands or contracts with gain or loss of heat till
measured temperature is
attained leading to the expansion or contraction of the
Bourdon tube which subsequently moves a pointer for indication.
 Types are:
 Gas filled (Gas Filled Thermometers)
 Liquid filled
 Mercury filled
 Vapour filled
2
8
Filled System Thermometer
 Liquid Filled Thermometer: They work on the principle of liquid expansion with
temperature rise. The filling liquid is usually an inert hydrocarbon viz. xylene which
has six times more expansion co-efficient than mercury decreasing the bulb position.
One criterion to be maintained is that the pressure inside must be greater than the
vapour pressure of liquid to prevent formation of bubbles inside. Solidification of
liquid is also not permitted.
 Mercury Filled Thermometer: Similar to that of liquid filled thermometers but
provides rapid response, accuracy and plenty of power. Pressure is as high as 1200
psig to as low as 400 psig. The high pressure reduces the head effect. They are
normally contained in stainless steel bulb increasing the corrosion resistance.
 Vapour Filled Thermometer: Here the bulb is partially filled with liquid and partially
with vapour. Some of the liquid vaporises during operation. The liquid inside boils
and vaporises creating gas inside the system. The liquid continues to boil until
pressure balance is obtained between systems and vapour pressure. Here liquid stops
boiling unless temperature rises. Similarly, when temperature drops, liquid and
vapour inside also cool causing some vapour to condense, bringing down the pressure
inside. When pressure inside equals vapour pressure, this action stops. Due to
changes in pressure, bourdon tube uncoils or tightens with increase or decrease of
pressure indicating temperature on a pointer scale.
2
9
Resistance Thermometer
 Also called resistance temperature detectors (RTDs).
 They are used to measure temperature by correlating the resistance of the
RTD element with temperature.
 The RTD element is made from a pure material, typically platinum, nickel or
copper.
 The material has a predictable change in resistance as the temperature changes
and it is this predictable change that is used to determine temperature.
 The elements are pretty fragile and therefore they are kept inside a sheathed
probe.
 RTD sensing elements constructed of platinum, copper or nickel have a
repeatable
resistance versus temperature relationship (R vs T) and operating temperature
range.
 R vs T relationship is defined as the amount of resistance change of the sensor
per degree of temperature change.
3
Resistance Thermometer
 Platinum is a noble metal having the most stable resistance – temperature
relationship over the largest temperature range making it the best element for
RTD with a very high repeatability over the range of -272.5 °C to 961.78 °C.
Platinum is also chemically inert.
 Nickel has limited temperature range as over 572 °F (300 °C), the relationship
tends to become non – linear. Cooper, though has very linear relationship
towards R vs T but it oxidizes at moderate temperature and cannot be used over
302 °F (150 °C).
 RTDs use electrical resistance as function of temperature change and require a
power source to operate. The resiatance value varies nearly linearly with
temperature following Callendar- Van Dusen equation.
 � 𝑇 = �0 1 + 𝐴𝑇 + 𝐵𝑇2
+ 𝐶𝑇3
𝑇 − 100
(−200 °𝐶 < 𝑇 <
0°𝐶)
 � 𝑇 = �0 1 + 𝐴𝑇
+ 𝐵𝑇2
(0 °𝐶 < 𝑇 <
850°𝐶)
 𝐴 = 3.9083 ∗ 10−3
°𝐶−1
; 𝐵 = −5.775 ∗ 10−7
°𝐶−2
, 𝐶 =
−4.183 ∗ 10−12
°𝐶−4
Resistance Thermometer
 The significant characteristic of metals used as resistive elements
is the linear approximation of the resistance versus temperature
relationship between 0 and 100 °C. This temperature
coefficient of resistance is called alpha, α. The equation below
defines α; its units are ohm/ohm/°C.
𝛼
=
�100−�
0100
�0
�100 = resistance of element at 100 ° C
�0= resistance of element at 0 ° C
 Pure platinum has an alpha of 0.003925 ohm/ohm/°C in the 0 to
100 °C range and is used in the construction of laboratory grade
RTDs. Alpha of platinum can be altered by doping. Copper has an
alpha value 0.0043 ohm/ohm/°C and nickel has 0.0068
ohm/ohm/°C.
Resistance Thermometer - Construction
 These elements nearly always require insulated leads attached.
 At temperatures below about 250 °C PVC, silicone rubber or
PTFE insulators are used.
Above this, glass fibre or ceramic are used.
 The measuring points, and usually most of the leads, require a
housing or protective sleeve, often made of a metal alloy which is
chemically inert to the process being monitored.
Resistance Thermometer – Wiring Configuration
 Two-wire configuration: The simplest resistance thermometer
configuration uses two wires. It is only used when high
accuracy is not required, as the resistance of the connecting
wires is added to that of the sensor, leading to errors of
measurement. This configuration allows use of 100 meters of
cable. This applies equally to balanced bridge and fixed bridge
system.
7
Resistance Thermometer – Wiring Configuration
 Three-wire configuration: In order to minimize the effects of
the lead resistances, a three-wire configuration can be used.
Using this method the two leads to the sensor are on adjoining
arms. There is a lead resistance in each arm of the bridge so that
the resistance is cancelled out, so long as the two lead
resistances are accurately the same. This configuration allows
up to 600 meters of cable.
 In the circuit shown below, if wires A and B are perfectly
matched in length, their impedance effects will cancel because
each is in an opposite leg of the bridge. The third wire, C, acts
as a sense lead and carries a very small current.
8
Resistance Thermometer – Wiring Configuration
 Four-wire configuration: The four-wire resistance
configuration increases the accuracy of measurement of
resistance. Four-terminal sensing eliminates voltage drop in the
measuring leads as a contribution to error. To increase accuracy
further, any residual thermoelectric voltages generated by
different wire types or screwed connections are eliminated by
reversal of the direction of the 1 mA current and the leads to
the DVM (Digital Voltmeter). The thermoelectric voltages will
be produced in one direction only. By averaging the reversed
measurements, the thermoelectric error voltages are cancelled
out.
9
1
3
Wire-wound
elements
Coiled
elements
Resistance Thermometer – Element Types
 Three main categories of RTD sensors are thin film, wire-
wound, and coiled elements.
Carbon resistors are used at ultra-low temperatures (-173 °C to
-273 °C).
 Carbon resistor elements are widely available and are very
inexpensive. They are most reliable at extreme low temperature
and do not suffer hysteresis and strain gauge effects.
 Strain free elements use a wire coil minimally supported within a
sealed housing filled with an inert gas. These sensors are used up
to 961.78 °C and they consist of platinum wire loosely coiled over
a support structure to provide free expansion and contraction with
temperature. They are highly sensitive to vibration and shock.
1
1
Resistance Thermometer - Features
 Advantages of Resistance Thermometers:
 High accuracy
 Wide temperature range, normally between – 200 ° and 650 °C
 Smaller in size, faster in response
 Good repeatability stable and accurate performance over many years
 Temperature compensation is not required
 Disadvantages of Resistance Thermometers:
 Higher cost
 Bridge circuit and power supply are needed
 Heating of resistance elements and current through bridge circuits lead to
inaccuracy
 Mechanical abuse induced because of vibration
 Larger bulb size than thermocouples
 Slower response time than thermistors.
1
4
RTDs vs Thermocouples
 Temperature: If process temperatures are between −200 to 500 °C (−328.0
to 932.0
°F), an industrial RTD is the preferred option. Thermocouples have a range of
−180 to 2,320 °C (−292.0 to 4,208.0 °F), so for temperatures above 500 °C
(932 °F) they are the only contact temperature measurement device.
 Response time: If the process requires a very fast response to temperature
changes— fractions of a second as opposed to seconds (e.g. 2.5 to 10 s)—then
a thermocouple is the best choice. Time response is measured by immersing
the sensor in water moving at 1 m/s (3 ft/s) with a 63.2% step change.
 Size: A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in
diameter;
sheath diameters for thermocouples can be less than 1.6 mm (0.063 in).
 Accuracy and stability requirements: If a tolerance of 2 °C is acceptable and
the highest level of repeatability is not required, a thermocouple will serve.
RTDs are capable of higher accuracy and can maintain stability for many
years, while thermocouples can drift within the first few hours of use.
1
6
Thermocouple
 Thermocouples consist of two wire legs made from different metals.
 The wire’s legs are welded together at one end, creating a junction.
 This junction is where the temperature is measured.
 When the junction experiences a change in temperature, a voltage is created.
 The voltage can then be interpreted using thermocouple reference tables to
calculate the temperature.
 There are many types of thermocouples, each with its own unique
characteristics in terms of temperature range, durability, vibration resistance,
chemical resistance, and application compatibility.
 Type J, K, T, & E are “Base
Metal” thermocouples, the most common types of
thermocouples.
 Type R, S, and B thermocouples are “Noble Metal” thermocouples, which are
used in high temperature applications.
 Thermocouples are self-powered and require no external form of excitation.
 Thermocouples do not actually measure an absolute temperature; they only
measure the temperature difference between two points, commonly known as
the hot and cold junctions.
1
7
Thermocouple – Working Principle
 Thomas Johann Seebeck discovered that when any conductor is
subject to a thermal gradient, it generates a voltage. This is now
known as the thermoelectric effect or Seebeck effect.
 Any attempt to measure this voltage necessarily involves
connecting another conductor to the "hot" end.
 The additional conductor experiences the same temperature
gradient and also develops
a voltage, which normally opposes the original.
1
8
Thermocouple – Working Principle
 Seebeck Effect: Energetic electrons at the hot end diffuse toward the cold end,
pushing less energetic electrons along with them, resulting in a higher static
potential at the hot end relative to the cold end. The larger the temperature
gradient, the larger is the potential difference.
� 𝒆𝒎𝒇 = −𝑺𝛁�
 Classical Configuration: To make the thermal effects measurable, two different
metal conductors are used.
 They must be chemically, electrically, and physically compatible. They produce
different
electric potentials when subject to the same thermal gradient.
 In the classical configuration, the dissimilar thermocouple wires are welded
together at the measurement end (hot junction), and again at the reference end
(cold junction), forming a loop.
 The hot junction assures that the potential at that point matches in the two metals.
Immersing the reference-end junction in an ice-water slurry assures that the
temperature gradients are the same across both materials.
 The ice-water slurry establishes a reference temperature at 0 ° C.
1
9
Thermocouple - Features
 Advantages of Thermocouple:
 Capable of being used to directly measure temperatures up to 2600°C
 Maybe brought into direct contact with the material being measured
 High resolution
 Rugged and reliable
 Disadvantages of Thermocouple:
Non-linear Complex operation
Two measurements required
Calibration required when in use
2
1
Thermocouple - Types
 There are several types of thermocouple based on the combination of
metals/alloys for the two junctions which are chosen on the merit of
temperature range, sensitivity, inertness and magnetic effects.
 Few types are J, K, T, N, E, B, R, S, M, C, D, G, P and W.
 Type J, K, T, & E are “Base Metal” thermocouples, the most common types of
thermocouples.
 Type R, S, and B thermocouples are “Noble Metal” thermocouples, which
are used in
high temperature applications.
2
2
Thermocouple - Types
Type Material Temperature Range Accuracy % Remark
J Iron –
Constantan
−40 °C to +750 °C +/- .75% Reliable, shorter lifespan,
narrow
range
K Nickel-Chromel/
Nickel-Alumel
−200 °C to +1350 °C +/- 0.75 Inexpensive, accurate,
reliable and
wide range
T Copper-
Constantan
−250 °C to 350 °C +/- 0.75 Stable, cryogenic
measurement
E Nickel-Chromel/
Constantan
−270 °C to 870 °C +/- 0.50 Stronger signal and higher
accuracy
than k & J type
R Platinum-
Rhodium
(87:13)
−50 °C to 1600 °C +/- 0.25 High accuracy and
stability. High
resistance to oxidation and
corrosion
B Platinum-
Rhodium
(70:30)
0 °C to 1700 °C +/- 0.5% Extreme high temperature
S Platinum-
Rhodium
(90:10)
−50 °C to 1600 °C +/- .25% Extreme high
temperature. High
resistance to oxidation and
corrosion
M Nickel- Upper limit: 1400 °C +/- 0.75% Rare in use
2
3
RTD – Thermocouple - Thermister
Criteria Thermocouple RTD Thermistor
Temp Range -267°C to
2316°C
-240°C to 649°C -100°C to 500°C
Accuracy Good Best Good
Linearity Better Best Good
Sensitivity Good Better Best
Cost Best Good Better
2
4
Thermister
 Thermistors are thermally sensitive resistors whose prime function is to
exhibit a large, predictable and precise change in electrical resistance
when subject to a corresponding change in body temperature.
 These are semiconductors made from a specific mixture of pure oxides of
nickel,
manganese, copper, cobalt, iron, magnesium, titanium and other metals
sintered at 982
°C.
 Negative Temperature Coefficient (NTC) thermistors exhibit a decrease in
electrical resistance when subject to an increase in body temperature and
Positive Temperature Coefficient (PTC) thermistors exhibit an increase
in electrical resistance when subject to an increase in body temperature.
2
5
Thermister
 Thermistors differ from resistance temperature detectors
(RTDs) in that the material
used in a thermistor is generally a ceramic or polymer, while RTDs
use pure metals.
 Range of Operation: −90 °C to 130 °C. Accuracy: ±0.1°C or
±0.2°C.
2
6
Thermister - Principle
 The Steinhart-Hart equation gives the reciprocal of absolute
temperature as a function of the resistance of a thermistor.
Using the Steinhart-Hart equation, we calculate the temperature
of the thermistor from the measured resistance.
 The Steinhardt-Hart
equation is
�
𝟏
= 𝑨 + 𝑩 ∗
𝐥𝐧 �
+
𝑪(𝐥𝐧(�))
�
 Where A, B and C are Steinhart–Hart parameters. R is
theresistance and T is
temperature; A = 0.001284; B = 2.364x 10-4; C = 9.304x 10-8
 The resistance value of a thermistor is given by the following
equation
 R= the resistance at temperature T in Kelvin (= °C +273)
 R Ref = the resistance at a reference temperature T0 in Kelvin
 β = B-value specified for this thermistor
 T = Temperature under measurement, T Ref = Reference temperature
2
7
Thermister - Principle
 To measure temperature with a thermistor, it is placed in the measuring environment
and as temperature increases, the resistance decreases (assuming NTC), and vice
versa.
 The thermistor is placed in one leg of a Wheatstone bridge circuit and at balanced
condition with
no change of temperature, the meter indicates zero.
 With changes in temperature, the Wheatstone bridge becomes unbalanced and an
electric current flows in the circuit.
 In this bridge circuit, three resistors are constant, R a, R b, and R c, while the resistive
sensor, RS, varies depending upon some physical variable - like temperature, light
level, etc. That's where the thermistor can be used.
 The thermistor can be placed anywhere in the bridge with three constant resistors, but
different placements can produce different behaviour in the bridge. For example,
different placements might cause the output voltage to go in different directions as
the temperature changes.
2
8
Thermister - Configuration
 Thermistors come in two-, three-, or four-wire configurations
 When there are more than two wires, the
additional wires are solely used for
connecting to the excitation source.
 A three- or four-wire connection method places leads on a high-impedance
path through the measurement device, effectively attenuating error caused by
lead-wire resistance (RL).
2
9
Thermister - Features
 Advantages of Thermistors:
 Thermistors offer better accuracy in comparison to RTDs and thermocouples.
 Unlike RTDs and thermocouples, they are highly sensitive.
 They are smaller in size as compared to thermocouples.
 Thermistors provide faster response than RTDs.
 They offer high stability and brilliant repeatability.
 They are very reliable and convenient to use.
 Unlike thermocouples which provide millivolt outputs, use of thermistors result in
reasonable output voltages.
 Thermistors are particularly low cost and easily adaptable temperature sensors.
 Disadvantages of Thermistors:
 Highly non-linear
 Limited temperature range
3
0
Pyrometer

It measures the amount of heat that is radiated from an
object.

The device compares the brightness produced by the radiation
of the object whose temp is to be measured

An eye piece at the left side
and an optical lens on the right

A reference lamp

A rheostat to change the
current and brightness

An absorption screen is fitted
between the optical lens and
the reference bulb, so as to
increase the temp range
Working
1.The radiation from the source is emitted and the
optical objective lens captures it.
2.The lens helps in focusing the thermal radiation on to the
reference bulb.
3.The observer watches the process through the eye piece
and corrects it in such a manner that the reference lamp
filament has a sharp focus and the filament is super-imposed
on the temperature source image.
4.The observer starts changing the rheostat values and the
current in the reference lamp changes.
5.This in turn, changes its intensity.
This change in current can be observed in three different ways.
The filament is dark. That is, cooler than the
temperature source.
Filament is bright. That is, hotter than the
temperature source.
Filament disappears. Thus, there is equal
brightness between the filament and
temperature source
•
Advantages
1. Provides a very high accuracy with +/-5º Celsius.
2. The biggest advantage of this device is that, there is no direct
contact between the pyrometer and the object whose
temperature is to be found out.
•
Disadvantages
1. As the measurement is based on the light intensity, the device
can be used only in applications with a minimum temperature
of 700º Celsius.
2. The device is not useful for obtaining continuous values of
temperatures at small intervals.
Temperature Measurements

Contenu connexe

Tendances

Thermal Conductivity.pptx
Thermal Conductivity.pptxThermal Conductivity.pptx
Thermal Conductivity.pptxAhsanMuhammad22
 
Pressure measurement
Pressure measurementPressure measurement
Pressure measurementBRIJ10PATEL
 
Pressure measuring devices
Pressure measuring devicesPressure measuring devices
Pressure measuring devicesAkash Patel
 
Temperature measurment devices
Temperature measurment devicesTemperature measurment devices
Temperature measurment devicesdarshit34
 
Liquid level measurement
Liquid level measurementLiquid level measurement
Liquid level measurementKarnav Rana
 
Temperature measurments
Temperature measurmentsTemperature measurments
Temperature measurmentsPrem Baboo
 
Chapter temperature measurement
Chapter  temperature measurementChapter  temperature measurement
Chapter temperature measurementNaman Dave
 
Unit 5 temperature measurement
Unit 5 temperature measurementUnit 5 temperature measurement
Unit 5 temperature measurementParneet Chowdhary
 
Temparature measurement presentation
Temparature measurement presentationTemparature measurement presentation
Temparature measurement presentationAVISHEK KUMAR
 
Electrical temperature measurement
Electrical temperature measurementElectrical temperature measurement
Electrical temperature measurementRonak Parmar
 
Resistance thermometer circuit
Resistance thermometer circuitResistance thermometer circuit
Resistance thermometer circuitsujeethvarada15
 
Bimetallic thermometer
Bimetallic thermometerBimetallic thermometer
Bimetallic thermometerVaibhavBajaj17
 
Bimetallic thermometer
Bimetallic thermometerBimetallic thermometer
Bimetallic thermometerdhruvkd786
 
RTD-RESISTANCE TEMPERATURE DETECTOR
RTD-RESISTANCE TEMPERATURE DETECTORRTD-RESISTANCE TEMPERATURE DETECTOR
RTD-RESISTANCE TEMPERATURE DETECTORkaroline Enoch
 
Temperature Measurement
Temperature MeasurementTemperature Measurement
Temperature MeasurementKalpu_IS
 

Tendances (20)

Thermal Conductivity.pptx
Thermal Conductivity.pptxThermal Conductivity.pptx
Thermal Conductivity.pptx
 
Pressure measurement
Pressure measurementPressure measurement
Pressure measurement
 
Pressure measuring devices
Pressure measuring devicesPressure measuring devices
Pressure measuring devices
 
Temperature measurment devices
Temperature measurment devicesTemperature measurment devices
Temperature measurment devices
 
Liquid level measurement
Liquid level measurementLiquid level measurement
Liquid level measurement
 
Temperature measurments
Temperature measurmentsTemperature measurments
Temperature measurments
 
Chapter temperature measurement
Chapter  temperature measurementChapter  temperature measurement
Chapter temperature measurement
 
OPTICAL PYROMETER
OPTICAL PYROMETEROPTICAL PYROMETER
OPTICAL PYROMETER
 
Unit 5 temperature measurement
Unit 5 temperature measurementUnit 5 temperature measurement
Unit 5 temperature measurement
 
bimetallic strip
bimetallic stripbimetallic strip
bimetallic strip
 
Temparature measurement presentation
Temparature measurement presentationTemparature measurement presentation
Temparature measurement presentation
 
Electrical temperature measurement
Electrical temperature measurementElectrical temperature measurement
Electrical temperature measurement
 
Thermistor
ThermistorThermistor
Thermistor
 
Resistance thermometer circuit
Resistance thermometer circuitResistance thermometer circuit
Resistance thermometer circuit
 
Bimetallic thermometer
Bimetallic thermometerBimetallic thermometer
Bimetallic thermometer
 
Bimetallic thermometer
Bimetallic thermometerBimetallic thermometer
Bimetallic thermometer
 
RTD-RESISTANCE TEMPERATURE DETECTOR
RTD-RESISTANCE TEMPERATURE DETECTORRTD-RESISTANCE TEMPERATURE DETECTOR
RTD-RESISTANCE TEMPERATURE DETECTOR
 
Heat conduction
Heat conduction Heat conduction
Heat conduction
 
Temperature Measurement
Temperature MeasurementTemperature Measurement
Temperature Measurement
 
Thermocouple
ThermocoupleThermocouple
Thermocouple
 

Similaire à Temperature Measurements

Temperaturemsmt 130906055901-
Temperaturemsmt 130906055901-Temperaturemsmt 130906055901-
Temperaturemsmt 130906055901-darshit34
 
Temperature measurement
Temperature measurementTemperature measurement
Temperature measurementbkdevaraj
 
TEMPERATURE MEASUREMENTS.pptx .
TEMPERATURE MEASUREMENTS.pptx              .TEMPERATURE MEASUREMENTS.pptx              .
TEMPERATURE MEASUREMENTS.pptx .happycocoman
 
Temperature measure 28.feb.2014
Temperature measure 28.feb.2014Temperature measure 28.feb.2014
Temperature measure 28.feb.2014Feroz Ahmed
 
L 04(ss)(ia&amp;c) ((ee)nptel)
L 04(ss)(ia&amp;c) ((ee)nptel)L 04(ss)(ia&amp;c) ((ee)nptel)
L 04(ss)(ia&amp;c) ((ee)nptel)Bharat Sharma
 
Thermocouple and RTD.pptx
Thermocouple and RTD.pptxThermocouple and RTD.pptx
Thermocouple and RTD.pptxYashGarale1
 
Introduction to transducers
Introduction to transducersIntroduction to transducers
Introduction to transducersYogesh Kirange
 
temperature measurement theories of operation rev1
temperature measurement theories of operation  rev1temperature measurement theories of operation  rev1
temperature measurement theories of operation rev1Mostafa Ragab
 
Temperature measurement part II
Temperature measurement   part IITemperature measurement   part II
Temperature measurement part IIBurdwan University
 
presentation slide
 presentation slide presentation slide
presentation slideSmit Javiya
 
Seminar report on Temperature Measuring Devices
Seminar report on Temperature Measuring DevicesSeminar report on Temperature Measuring Devices
Seminar report on Temperature Measuring DevicesAmbrish Rai
 
presentation_instrumentation_lab_1462353698_205162.pptx
presentation_instrumentation_lab_1462353698_205162.pptxpresentation_instrumentation_lab_1462353698_205162.pptx
presentation_instrumentation_lab_1462353698_205162.pptxDHANAPALR7
 

Similaire à Temperature Measurements (20)

thermometry
thermometrythermometry
thermometry
 
Temperaturemsmt 130906055901-
Temperaturemsmt 130906055901-Temperaturemsmt 130906055901-
Temperaturemsmt 130906055901-
 
Temperature measurement
Temperature measurementTemperature measurement
Temperature measurement
 
Tempreture measurement
Tempreture measurementTempreture measurement
Tempreture measurement
 
TEMPERATURE MEASUREMENTS.pptx .
TEMPERATURE MEASUREMENTS.pptx              .TEMPERATURE MEASUREMENTS.pptx              .
TEMPERATURE MEASUREMENTS.pptx .
 
module 5.pdf
module 5.pdfmodule 5.pdf
module 5.pdf
 
Temperature measure 28.feb.2014
Temperature measure 28.feb.2014Temperature measure 28.feb.2014
Temperature measure 28.feb.2014
 
TEMPRATURE MEASUREMENT INSTRUMENTS
TEMPRATURE MEASUREMENT INSTRUMENTSTEMPRATURE MEASUREMENT INSTRUMENTS
TEMPRATURE MEASUREMENT INSTRUMENTS
 
L 04(ss)(ia&amp;c) ((ee)nptel)
L 04(ss)(ia&amp;c) ((ee)nptel)L 04(ss)(ia&amp;c) ((ee)nptel)
L 04(ss)(ia&amp;c) ((ee)nptel)
 
Temperature Sensors
Temperature SensorsTemperature Sensors
Temperature Sensors
 
heat
heat heat
heat
 
Thermomters
ThermomtersThermomters
Thermomters
 
Thermocouple and RTD.pptx
Thermocouple and RTD.pptxThermocouple and RTD.pptx
Thermocouple and RTD.pptx
 
Presentation (Temperature )
Presentation (Temperature   )Presentation (Temperature   )
Presentation (Temperature )
 
Introduction to transducers
Introduction to transducersIntroduction to transducers
Introduction to transducers
 
temperature measurement theories of operation rev1
temperature measurement theories of operation  rev1temperature measurement theories of operation  rev1
temperature measurement theories of operation rev1
 
Temperature measurement part II
Temperature measurement   part IITemperature measurement   part II
Temperature measurement part II
 
presentation slide
 presentation slide presentation slide
presentation slide
 
Seminar report on Temperature Measuring Devices
Seminar report on Temperature Measuring DevicesSeminar report on Temperature Measuring Devices
Seminar report on Temperature Measuring Devices
 
presentation_instrumentation_lab_1462353698_205162.pptx
presentation_instrumentation_lab_1462353698_205162.pptxpresentation_instrumentation_lab_1462353698_205162.pptx
presentation_instrumentation_lab_1462353698_205162.pptx
 

Plus de saahil kshatriya

Valve Timing Diagram (2161902) ICE
Valve Timing Diagram (2161902) ICEValve Timing Diagram (2161902) ICE
Valve Timing Diagram (2161902) ICEsaahil kshatriya
 
Effectiveness Of Parallel Flow Heat Exchanger (2151909)
Effectiveness Of Parallel Flow Heat Exchanger (2151909)Effectiveness Of Parallel Flow Heat Exchanger (2151909)
Effectiveness Of Parallel Flow Heat Exchanger (2151909)saahil kshatriya
 
DYNAMICS OF MACHINES (2161901)
DYNAMICS OF MACHINES (2161901)DYNAMICS OF MACHINES (2161901)
DYNAMICS OF MACHINES (2161901)saahil kshatriya
 
Gas Metal Arc Welding (GMAW)
Gas Metal Arc Welding (GMAW)Gas Metal Arc Welding (GMAW)
Gas Metal Arc Welding (GMAW)saahil kshatriya
 
self inductance , mutual inductance and coeffecient of coupling
self inductance , mutual inductance and coeffecient of couplingself inductance , mutual inductance and coeffecient of coupling
self inductance , mutual inductance and coeffecient of couplingsaahil kshatriya
 
System Of Linear Equations
System Of Linear EquationsSystem Of Linear Equations
System Of Linear Equationssaahil kshatriya
 
the Road Not Taken- Robert Frost
the Road Not Taken- Robert Frostthe Road Not Taken- Robert Frost
the Road Not Taken- Robert Frostsaahil kshatriya
 
FOUR BAR CHAIN AND INVERSIONS
FOUR BAR CHAIN AND INVERSIONSFOUR BAR CHAIN AND INVERSIONS
FOUR BAR CHAIN AND INVERSIONSsaahil kshatriya
 
Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...
Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...
Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...saahil kshatriya
 
Thermodynamic sysytem and control volume and properties
Thermodynamic sysytem and control volume and propertiesThermodynamic sysytem and control volume and properties
Thermodynamic sysytem and control volume and propertiessaahil kshatriya
 

Plus de saahil kshatriya (14)

Valve Timing Diagram (2161902) ICE
Valve Timing Diagram (2161902) ICEValve Timing Diagram (2161902) ICE
Valve Timing Diagram (2161902) ICE
 
Effectiveness Of Parallel Flow Heat Exchanger (2151909)
Effectiveness Of Parallel Flow Heat Exchanger (2151909)Effectiveness Of Parallel Flow Heat Exchanger (2151909)
Effectiveness Of Parallel Flow Heat Exchanger (2151909)
 
DYNAMICS OF MACHINES (2161901)
DYNAMICS OF MACHINES (2161901)DYNAMICS OF MACHINES (2161901)
DYNAMICS OF MACHINES (2161901)
 
Shuttle valve
Shuttle valveShuttle valve
Shuttle valve
 
Double acting cylinder
Double acting cylinderDouble acting cylinder
Double acting cylinder
 
money, functions
money, functionsmoney, functions
money, functions
 
Gas Metal Arc Welding (GMAW)
Gas Metal Arc Welding (GMAW)Gas Metal Arc Welding (GMAW)
Gas Metal Arc Welding (GMAW)
 
self inductance , mutual inductance and coeffecient of coupling
self inductance , mutual inductance and coeffecient of couplingself inductance , mutual inductance and coeffecient of coupling
self inductance , mutual inductance and coeffecient of coupling
 
System Of Linear Equations
System Of Linear EquationsSystem Of Linear Equations
System Of Linear Equations
 
the Road Not Taken- Robert Frost
the Road Not Taken- Robert Frostthe Road Not Taken- Robert Frost
the Road Not Taken- Robert Frost
 
FOUR BAR CHAIN AND INVERSIONS
FOUR BAR CHAIN AND INVERSIONSFOUR BAR CHAIN AND INVERSIONS
FOUR BAR CHAIN AND INVERSIONS
 
Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...
Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...
Laplace transform: UNIT STEP FUNCTION, SECOND SHIFTING THEOREM, DIRAC DELTA F...
 
Thermodynamic sysytem and control volume and properties
Thermodynamic sysytem and control volume and propertiesThermodynamic sysytem and control volume and properties
Thermodynamic sysytem and control volume and properties
 
Extinction
ExtinctionExtinction
Extinction
 

Dernier

Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxfenichawla
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGSIVASHANKAR N
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...roncy bisnoi
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingrknatarajan
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 

Dernier (20)

Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and workingUNIT-V FMM.HYDRAULIC TURBINE - Construction and working
UNIT-V FMM.HYDRAULIC TURBINE - Construction and working
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 

Temperature Measurements

  • 1. Mechanical Measurement And Metrology(2141901) Active Learning Assignment Topics: Temperature Measurement Guided By: Prof. Jigar Paghadal Branch : Mechanical Engineering Div: 4C2 Submitted by: Saahil R Kshatriya Enrollment Number: 150120119164
  • 2.  The means of accurately measuring temperatures has long fascinated people.  One of the differences between temperature and other physical concepts, such as mass or length, is that it is subjective.  Different people will have different perceptions of what is hot and what is cold.  To make objective measurements, we must use thermometer in which some physical property of a substance changes with temperature in a reliable and reproducible way.
  • 3. Scale  Temperature is a measure of the thermal energy in the body. Normally measured in degrees [°]using one of the following scales. 1. Fahrenheit.[°F] 2. Celsius or centigrade. [°C] 3. Kelvin .[°K]
  • 4.
  • 5. Temperature measurement  The following characteristics can be used to measure the temperature  A change in dimentions - expansion or contraction of material w.r.t. Temp change  A change in electrical resistance of metals and semi-conductors w.r.t. Temp change  A thermo-electric emf produced due to temp difference at two junctions of two metal alloy joined together  A change in intensity and colour of radiation emitted by the hot body w.r.t to change in temp
  • 6. Expansion thermometers  (1)Bimetalic thermometer -solid expansion  (2)Liquid in glass thermometers
  • 7. Methods of Temperature Measurement • Expansion Thermometer  Bimetallic Thermometer (Expansion of Solid)  Liquid in Glass Thermometer (Expansion of Liquid)  Liquid in Metal Thermometer (Expansion of Liquid)  Gas Thermometer • Filled System Thermometer  Liquid filled Thermometer  Mercury filled Thermometer  Vapour pressure Thermometer  Electrical Temperature Instrument  Resistance Thermometer  Thermocouple  Thermistor  Thermopile  Electrical Temperature Instrument  Resistance Thermometer  Thermocouple  Thermistor  Thermopile  Other Methods of Temperature Measurement  Quartz Thermometer  Solid State Temperature Measurement  Optical Fibre Temperature Measurement  Ultrasonic Thermometer
  • 8. 1.Bulb: The reservoir for containing most of the thermometric liquid (mercury). 2.Stem: The glass tube having a capillary bore along which the liquid moves with changes in temperature. 3. Scale: A narrow-temperature-range scale for reading a reference temperature . Construction 1.Liquid – in – Glass Thermometer
  • 9. • The volume of mercury changes slightly with temperature; the small change in volume drives the narrow mercury column a relatively long way up the tube. • The space above the mercury may be filled with nitrogen or it may be at less than atmospheric pressure, a partial vacuum.
  • 10.  Advantages 1) Simplicity in use & low cost. 2) Portable device. 3) Checking physical damage is easy. 4) Power source not require. Disadvantages 1) Can not used for automatic recording. 2) Time lag in measurement. 3) Range is limited to about 300 °C .
  • 11. 2.Bimetallic Thermometer In an industry, there is always a need to measure and monitor temperature of a particular spot, field or locality. The industrial names given to such temperature sensors are Temperature Indicators (TI) or Temperature Gauges (TG). All these temperature gauges belong to the class of instruments that are known as bimetallic sensors.
  • 12. Bimetallic Thermometer Two basic principles of operation is to be followed in the case of a bimetallic sensor. 1) A metal tends to undergo a volumetric dimensional change (expansion/contraction), according to the change in temperature. 2) Different metals have different co-efficient of temperatures. The rate of volumetric change depends on this co-efficient of temperature.
  • 14. • The device consists of a bimetallic strip of two different metals . • They are bonded together to form a spiral or a twisted helix. • Both these metals are joined together at one end by either welding or riveting. • It is bonded so strong that there will not be any relative motion between the two. • The image of a bimetallic strip is shown below.
  • 15.
  • 16.  A change in temperature causes the free end of the strip to expand or contract due to the different coefficients of expansion of the two metals.  This movement is linear to the change in temperature and the deflection of the free end can be read out by attaching a pointer to it.  This reading will indicate the value of temperature. Bimetallic strips are available in different forms like helix type, cantilever, spiral, and also flat type. Construction
  • 17.  Advantages 1) Power source not required 2) Robust, easy to use and cheap. 3) Can be used to 500 °C. Disadvantages 1) Not very accurate. 2) Limited to applications where manual reading is acceptable. 3) Not suitable for very low temperatures because the expansion of metals tend to be too similar, so the device becomes a rather insensitive thermometer
  • 18. Filled System Thermometer  Filled system thermometers consist of Bourdon tube, a capillary tube and a thermometer bulb all interconnected.  The entire point is sealed after appropriate liquid filling at NTP and commonly used liquids are mercury, ethyl alcohol, xylene and toluene.  Liquid expands or contracts with gain or loss of heat till measured temperature is attained leading to the expansion or contraction of the Bourdon tube which subsequently moves a pointer for indication.  Types are:  Gas filled (Gas Filled Thermometers)  Liquid filled  Mercury filled  Vapour filled 2 8
  • 19. Filled System Thermometer  Liquid Filled Thermometer: They work on the principle of liquid expansion with temperature rise. The filling liquid is usually an inert hydrocarbon viz. xylene which has six times more expansion co-efficient than mercury decreasing the bulb position. One criterion to be maintained is that the pressure inside must be greater than the vapour pressure of liquid to prevent formation of bubbles inside. Solidification of liquid is also not permitted.  Mercury Filled Thermometer: Similar to that of liquid filled thermometers but provides rapid response, accuracy and plenty of power. Pressure is as high as 1200 psig to as low as 400 psig. The high pressure reduces the head effect. They are normally contained in stainless steel bulb increasing the corrosion resistance.  Vapour Filled Thermometer: Here the bulb is partially filled with liquid and partially with vapour. Some of the liquid vaporises during operation. The liquid inside boils and vaporises creating gas inside the system. The liquid continues to boil until pressure balance is obtained between systems and vapour pressure. Here liquid stops boiling unless temperature rises. Similarly, when temperature drops, liquid and vapour inside also cool causing some vapour to condense, bringing down the pressure inside. When pressure inside equals vapour pressure, this action stops. Due to changes in pressure, bourdon tube uncoils or tightens with increase or decrease of pressure indicating temperature on a pointer scale. 2 9
  • 20.
  • 21. Resistance Thermometer  Also called resistance temperature detectors (RTDs).  They are used to measure temperature by correlating the resistance of the RTD element with temperature.  The RTD element is made from a pure material, typically platinum, nickel or copper.  The material has a predictable change in resistance as the temperature changes and it is this predictable change that is used to determine temperature.  The elements are pretty fragile and therefore they are kept inside a sheathed probe.  RTD sensing elements constructed of platinum, copper or nickel have a repeatable resistance versus temperature relationship (R vs T) and operating temperature range.  R vs T relationship is defined as the amount of resistance change of the sensor per degree of temperature change. 3
  • 22. Resistance Thermometer  Platinum is a noble metal having the most stable resistance – temperature relationship over the largest temperature range making it the best element for RTD with a very high repeatability over the range of -272.5 °C to 961.78 °C. Platinum is also chemically inert.  Nickel has limited temperature range as over 572 °F (300 °C), the relationship tends to become non – linear. Cooper, though has very linear relationship towards R vs T but it oxidizes at moderate temperature and cannot be used over 302 °F (150 °C).  RTDs use electrical resistance as function of temperature change and require a power source to operate. The resiatance value varies nearly linearly with temperature following Callendar- Van Dusen equation.  � 𝑇 = �0 1 + 𝐴𝑇 + 𝐵𝑇2 + 𝐶𝑇3 𝑇 − 100 (−200 °𝐶 < 𝑇 < 0°𝐶)  � 𝑇 = �0 1 + 𝐴𝑇 + 𝐵𝑇2 (0 °𝐶 < 𝑇 < 850°𝐶)  𝐴 = 3.9083 ∗ 10−3 °𝐶−1 ; 𝐵 = −5.775 ∗ 10−7 °𝐶−2 , 𝐶 = −4.183 ∗ 10−12 °𝐶−4
  • 23. Resistance Thermometer  The significant characteristic of metals used as resistive elements is the linear approximation of the resistance versus temperature relationship between 0 and 100 °C. This temperature coefficient of resistance is called alpha, α. The equation below defines α; its units are ohm/ohm/°C. 𝛼 = �100−� 0100 �0 �100 = resistance of element at 100 ° C �0= resistance of element at 0 ° C  Pure platinum has an alpha of 0.003925 ohm/ohm/°C in the 0 to 100 °C range and is used in the construction of laboratory grade RTDs. Alpha of platinum can be altered by doping. Copper has an alpha value 0.0043 ohm/ohm/°C and nickel has 0.0068 ohm/ohm/°C.
  • 24. Resistance Thermometer - Construction  These elements nearly always require insulated leads attached.  At temperatures below about 250 °C PVC, silicone rubber or PTFE insulators are used. Above this, glass fibre or ceramic are used.  The measuring points, and usually most of the leads, require a housing or protective sleeve, often made of a metal alloy which is chemically inert to the process being monitored.
  • 25. Resistance Thermometer – Wiring Configuration  Two-wire configuration: The simplest resistance thermometer configuration uses two wires. It is only used when high accuracy is not required, as the resistance of the connecting wires is added to that of the sensor, leading to errors of measurement. This configuration allows use of 100 meters of cable. This applies equally to balanced bridge and fixed bridge system. 7
  • 26. Resistance Thermometer – Wiring Configuration  Three-wire configuration: In order to minimize the effects of the lead resistances, a three-wire configuration can be used. Using this method the two leads to the sensor are on adjoining arms. There is a lead resistance in each arm of the bridge so that the resistance is cancelled out, so long as the two lead resistances are accurately the same. This configuration allows up to 600 meters of cable.  In the circuit shown below, if wires A and B are perfectly matched in length, their impedance effects will cancel because each is in an opposite leg of the bridge. The third wire, C, acts as a sense lead and carries a very small current. 8
  • 27. Resistance Thermometer – Wiring Configuration  Four-wire configuration: The four-wire resistance configuration increases the accuracy of measurement of resistance. Four-terminal sensing eliminates voltage drop in the measuring leads as a contribution to error. To increase accuracy further, any residual thermoelectric voltages generated by different wire types or screwed connections are eliminated by reversal of the direction of the 1 mA current and the leads to the DVM (Digital Voltmeter). The thermoelectric voltages will be produced in one direction only. By averaging the reversed measurements, the thermoelectric error voltages are cancelled out. 9
  • 29. Resistance Thermometer – Element Types  Three main categories of RTD sensors are thin film, wire- wound, and coiled elements. Carbon resistors are used at ultra-low temperatures (-173 °C to -273 °C).  Carbon resistor elements are widely available and are very inexpensive. They are most reliable at extreme low temperature and do not suffer hysteresis and strain gauge effects.  Strain free elements use a wire coil minimally supported within a sealed housing filled with an inert gas. These sensors are used up to 961.78 °C and they consist of platinum wire loosely coiled over a support structure to provide free expansion and contraction with temperature. They are highly sensitive to vibration and shock. 1 1
  • 30. Resistance Thermometer - Features  Advantages of Resistance Thermometers:  High accuracy  Wide temperature range, normally between – 200 ° and 650 °C  Smaller in size, faster in response  Good repeatability stable and accurate performance over many years  Temperature compensation is not required  Disadvantages of Resistance Thermometers:  Higher cost  Bridge circuit and power supply are needed  Heating of resistance elements and current through bridge circuits lead to inaccuracy  Mechanical abuse induced because of vibration  Larger bulb size than thermocouples  Slower response time than thermistors. 1 4
  • 31. RTDs vs Thermocouples  Temperature: If process temperatures are between −200 to 500 °C (−328.0 to 932.0 °F), an industrial RTD is the preferred option. Thermocouples have a range of −180 to 2,320 °C (−292.0 to 4,208.0 °F), so for temperatures above 500 °C (932 °F) they are the only contact temperature measurement device.  Response time: If the process requires a very fast response to temperature changes— fractions of a second as opposed to seconds (e.g. 2.5 to 10 s)—then a thermocouple is the best choice. Time response is measured by immersing the sensor in water moving at 1 m/s (3 ft/s) with a 63.2% step change.  Size: A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in).  Accuracy and stability requirements: If a tolerance of 2 °C is acceptable and the highest level of repeatability is not required, a thermocouple will serve. RTDs are capable of higher accuracy and can maintain stability for many years, while thermocouples can drift within the first few hours of use. 1 6
  • 32. Thermocouple  Thermocouples consist of two wire legs made from different metals.  The wire’s legs are welded together at one end, creating a junction.  This junction is where the temperature is measured.  When the junction experiences a change in temperature, a voltage is created.  The voltage can then be interpreted using thermocouple reference tables to calculate the temperature.  There are many types of thermocouples, each with its own unique characteristics in terms of temperature range, durability, vibration resistance, chemical resistance, and application compatibility.  Type J, K, T, & E are “Base Metal” thermocouples, the most common types of thermocouples.  Type R, S, and B thermocouples are “Noble Metal” thermocouples, which are used in high temperature applications.  Thermocouples are self-powered and require no external form of excitation.  Thermocouples do not actually measure an absolute temperature; they only measure the temperature difference between two points, commonly known as the hot and cold junctions. 1 7
  • 33. Thermocouple – Working Principle  Thomas Johann Seebeck discovered that when any conductor is subject to a thermal gradient, it generates a voltage. This is now known as the thermoelectric effect or Seebeck effect.  Any attempt to measure this voltage necessarily involves connecting another conductor to the "hot" end.  The additional conductor experiences the same temperature gradient and also develops a voltage, which normally opposes the original. 1 8
  • 34. Thermocouple – Working Principle  Seebeck Effect: Energetic electrons at the hot end diffuse toward the cold end, pushing less energetic electrons along with them, resulting in a higher static potential at the hot end relative to the cold end. The larger the temperature gradient, the larger is the potential difference. � 𝒆𝒎𝒇 = −𝑺𝛁�  Classical Configuration: To make the thermal effects measurable, two different metal conductors are used.  They must be chemically, electrically, and physically compatible. They produce different electric potentials when subject to the same thermal gradient.  In the classical configuration, the dissimilar thermocouple wires are welded together at the measurement end (hot junction), and again at the reference end (cold junction), forming a loop.  The hot junction assures that the potential at that point matches in the two metals. Immersing the reference-end junction in an ice-water slurry assures that the temperature gradients are the same across both materials.  The ice-water slurry establishes a reference temperature at 0 ° C. 1 9
  • 35. Thermocouple - Features  Advantages of Thermocouple:  Capable of being used to directly measure temperatures up to 2600°C  Maybe brought into direct contact with the material being measured  High resolution  Rugged and reliable  Disadvantages of Thermocouple: Non-linear Complex operation Two measurements required Calibration required when in use 2 1
  • 36. Thermocouple - Types  There are several types of thermocouple based on the combination of metals/alloys for the two junctions which are chosen on the merit of temperature range, sensitivity, inertness and magnetic effects.  Few types are J, K, T, N, E, B, R, S, M, C, D, G, P and W.  Type J, K, T, & E are “Base Metal” thermocouples, the most common types of thermocouples.  Type R, S, and B thermocouples are “Noble Metal” thermocouples, which are used in high temperature applications. 2 2
  • 37. Thermocouple - Types Type Material Temperature Range Accuracy % Remark J Iron – Constantan −40 °C to +750 °C +/- .75% Reliable, shorter lifespan, narrow range K Nickel-Chromel/ Nickel-Alumel −200 °C to +1350 °C +/- 0.75 Inexpensive, accurate, reliable and wide range T Copper- Constantan −250 °C to 350 °C +/- 0.75 Stable, cryogenic measurement E Nickel-Chromel/ Constantan −270 °C to 870 °C +/- 0.50 Stronger signal and higher accuracy than k & J type R Platinum- Rhodium (87:13) −50 °C to 1600 °C +/- 0.25 High accuracy and stability. High resistance to oxidation and corrosion B Platinum- Rhodium (70:30) 0 °C to 1700 °C +/- 0.5% Extreme high temperature S Platinum- Rhodium (90:10) −50 °C to 1600 °C +/- .25% Extreme high temperature. High resistance to oxidation and corrosion M Nickel- Upper limit: 1400 °C +/- 0.75% Rare in use 2 3
  • 38. RTD – Thermocouple - Thermister Criteria Thermocouple RTD Thermistor Temp Range -267°C to 2316°C -240°C to 649°C -100°C to 500°C Accuracy Good Best Good Linearity Better Best Good Sensitivity Good Better Best Cost Best Good Better 2 4
  • 39. Thermister  Thermistors are thermally sensitive resistors whose prime function is to exhibit a large, predictable and precise change in electrical resistance when subject to a corresponding change in body temperature.  These are semiconductors made from a specific mixture of pure oxides of nickel, manganese, copper, cobalt, iron, magnesium, titanium and other metals sintered at 982 °C.  Negative Temperature Coefficient (NTC) thermistors exhibit a decrease in electrical resistance when subject to an increase in body temperature and Positive Temperature Coefficient (PTC) thermistors exhibit an increase in electrical resistance when subject to an increase in body temperature. 2 5
  • 40. Thermister  Thermistors differ from resistance temperature detectors (RTDs) in that the material used in a thermistor is generally a ceramic or polymer, while RTDs use pure metals.  Range of Operation: −90 °C to 130 °C. Accuracy: ±0.1°C or ±0.2°C. 2 6
  • 41. Thermister - Principle  The Steinhart-Hart equation gives the reciprocal of absolute temperature as a function of the resistance of a thermistor. Using the Steinhart-Hart equation, we calculate the temperature of the thermistor from the measured resistance.  The Steinhardt-Hart equation is � 𝟏 = 𝑨 + 𝑩 ∗ 𝐥𝐧 � + 𝑪(𝐥𝐧(�)) �  Where A, B and C are Steinhart–Hart parameters. R is theresistance and T is temperature; A = 0.001284; B = 2.364x 10-4; C = 9.304x 10-8  The resistance value of a thermistor is given by the following equation  R= the resistance at temperature T in Kelvin (= °C +273)  R Ref = the resistance at a reference temperature T0 in Kelvin  β = B-value specified for this thermistor  T = Temperature under measurement, T Ref = Reference temperature 2 7
  • 42. Thermister - Principle  To measure temperature with a thermistor, it is placed in the measuring environment and as temperature increases, the resistance decreases (assuming NTC), and vice versa.  The thermistor is placed in one leg of a Wheatstone bridge circuit and at balanced condition with no change of temperature, the meter indicates zero.  With changes in temperature, the Wheatstone bridge becomes unbalanced and an electric current flows in the circuit.  In this bridge circuit, three resistors are constant, R a, R b, and R c, while the resistive sensor, RS, varies depending upon some physical variable - like temperature, light level, etc. That's where the thermistor can be used.  The thermistor can be placed anywhere in the bridge with three constant resistors, but different placements can produce different behaviour in the bridge. For example, different placements might cause the output voltage to go in different directions as the temperature changes. 2 8
  • 43. Thermister - Configuration  Thermistors come in two-, three-, or four-wire configurations  When there are more than two wires, the additional wires are solely used for connecting to the excitation source.  A three- or four-wire connection method places leads on a high-impedance path through the measurement device, effectively attenuating error caused by lead-wire resistance (RL). 2 9
  • 44. Thermister - Features  Advantages of Thermistors:  Thermistors offer better accuracy in comparison to RTDs and thermocouples.  Unlike RTDs and thermocouples, they are highly sensitive.  They are smaller in size as compared to thermocouples.  Thermistors provide faster response than RTDs.  They offer high stability and brilliant repeatability.  They are very reliable and convenient to use.  Unlike thermocouples which provide millivolt outputs, use of thermistors result in reasonable output voltages.  Thermistors are particularly low cost and easily adaptable temperature sensors.  Disadvantages of Thermistors:  Highly non-linear  Limited temperature range 3 0
  • 45. Pyrometer  It measures the amount of heat that is radiated from an object.  The device compares the brightness produced by the radiation of the object whose temp is to be measured  An eye piece at the left side and an optical lens on the right  A reference lamp  A rheostat to change the current and brightness  An absorption screen is fitted between the optical lens and the reference bulb, so as to increase the temp range
  • 46. Working 1.The radiation from the source is emitted and the optical objective lens captures it. 2.The lens helps in focusing the thermal radiation on to the reference bulb. 3.The observer watches the process through the eye piece and corrects it in such a manner that the reference lamp filament has a sharp focus and the filament is super-imposed on the temperature source image. 4.The observer starts changing the rheostat values and the current in the reference lamp changes. 5.This in turn, changes its intensity. This change in current can be observed in three different ways.
  • 47. The filament is dark. That is, cooler than the temperature source. Filament is bright. That is, hotter than the temperature source. Filament disappears. Thus, there is equal brightness between the filament and temperature source
  • 48. • Advantages 1. Provides a very high accuracy with +/-5º Celsius. 2. The biggest advantage of this device is that, there is no direct contact between the pyrometer and the object whose temperature is to be found out. • Disadvantages 1. As the measurement is based on the light intensity, the device can be used only in applications with a minimum temperature of 700º Celsius. 2. The device is not useful for obtaining continuous values of temperatures at small intervals.