SlideShare une entreprise Scribd logo
OM-217                      168 808F
                                         October 1998

                                         Processes

                                                Air Plasma Cutting
                                                and Gouging


                                         Description



                                         Air Plasma Cutter




                           Spectrum 1000 And 1250
                                   R




    Visit our website at
www.MillerWelds.com
From Miller to You
Thank you and congratulations on choosing Miller. Now
you can get the job done and get it done right. We know
you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc
welders in 1929, he made sure his products offered
long-lasting value and superior quality. Like you, his
customers couldn’t afford anything less. Miller products
had to be more than the best they could be. They had to
be the best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
                                                                              Working as hard as you
This Owner’s Manual is designed to help you get the most out of your          do – every power source
                                                                              from Miller is backed by
Miller products. Please take time to read the Safety precautions. They will   the most hassle-free war-
help you protect yourself against potential hazards on the worksite. We’ve    ranty in the business.
                            made installation and operation quick and easy.
                            With Miller you can count on years of reliable
                            service with proper maintenance. And if for
                            some reason the unit needs repair, there’s a
                            Troubleshooting section that will help you
Miller is the first welding figure out what the problem is. The parts list
equipment manufacturer in will then help you to decide which exact part
the U.S.A. to be registered
to the ISO 9001 Quality
                            you may need to fix the problem. Warranty and
System Standard.            service information for your particular model
                            are also provided.                                Miller offers a Technical
                                                                              Manual which provides
                                                                              more detailed service and
                                                                              parts information for your
                                                                              unit. To obtain a Technical
                                                                              Manual, contact your local
                                                                              distributor. Your distributor
                                                                              can also supply you with
                                                                              Welding Process Manuals
                                                                              such as SMAW, GTAW,
                                                                              GMAW, and GMAW-P.
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor
to receive the latest full line catalog or
individual catalog sheets. To locate your nearest
distributor call 1-800-4-A-Miller.
TABLE OF CONTENTS
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . .                                                     1
  1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .          1
  1-2. Plasma Arc Cutting Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                    1
  1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .                                             3
  1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  4
  1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .           4
SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .                                                         5
  1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  5
  1-2. Dangers liés au coupage à l’arc au plasma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                             5
  1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
        et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .           7
  1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                     7
  1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                  8
SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .               9
  2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  9
  2-2. Manufacturer’s Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                 11
  2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                 12
SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .               12
  3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .        12
  3-2. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                    13
  3-3. Cutting Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .         13
  3-4. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .            14
  3-5. Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                 15
  3-6. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   15
  3-7. Connecting Work Clamp And Gas/Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                  16
  3-8. Remote Control Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                      17
  3-9. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .              18
  3-10. Placing Jumper Links And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                    19
SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .              20
  4-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    20
SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                            21
  5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .               21
  5-2. Overload Protection: Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  22
  5-3. Overload Protection: Trouble Lights & Checking Shield Cup Shutdown System . . . . . . . . . .                                                         23
  5-4. Adjusting Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .               24
  5-5. Torch And Work Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                          25
  5-6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .           26
SECTION 6 – ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                            28
SECTION 7 – HF IN PLASMA CUTTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                         30
  7-1. High Frequency In Plasma Arc Cutting (PAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                30
  7-2. Sources Of High-Frequency Radiation From Incorrect Installation . . . . . . . . . . . . . . . . . . . . .                                             30
  7-3. Correct Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .          31
SECTION 8 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .           32
WARRANTY
Declaration of Conformity For
    European Community (CE) Products
   NOTE                           This information is provided for units with CE certification (see rating label on unit.)



Manufacturer’s Name:                Miller Electric Mfg. Co.
Manufacturer’s Address:             1635 W. Spencer Street
                                    Appleton, WI 54914 USA




Declares that the product:          Spectrum 1000 &1250
conforms to the following Directives and Standards:

                                                           Directives

                                              Low Voltage Directive: 73/23/EEC

                        Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC

                              Electromagnetic Compatibility Directives: 89/336/EEC, 92/31/EEC

                                                           Standards

                          Arc Welding Equipment, Plasma Cutting Systems: prEN 50192: 1995

                        Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1990

                              Arc Welding Equipment Part 1: Welding Power Sources: IEC 974-1
                                                (April 1995 – Draft revision)

                         Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989

                              Insulation coordination for equipment within low-voltage systems:
                                 Part 1: Principles, requirements and tests: IEC 664-1: 1992

                     Electromagnetic compatibility (EMC) Product standard for arc welding equipment:
                                                  EN50199: August 1995

      European Contact:             Mr. Luigi Vacchini, Managing Director
                                    MILLER Europe S.P.A.
                                    Via Privata Iseo
                                    20098 San Giuliano
                                    Milanese, Italy

                 Telephone:         39(02)98290-1
                       Fax:         39(02)98281-552

dec_con1 10/95
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE
                        USING
                                                                                                                                         pom _nd_5/97




1-1. Symbol Usage
             Means Warning! Watch Out! There are possible hazards
             with this procedure! The possible hazards are shown in
             the adjoining symbols.

Y Marks a special safety message.                                             This group of symbols means Warning! Watch Out! possible
                                                                              ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
. Means “Note”; not safety related.                                           Consult symbols and related instructions below for necessary actions
                                                                              to avoid the hazards.


1-2. Plasma Arc Cutting Hazards
Y The symbols shown below are used throughout this manual to
  call attention to and identify possible hazards. When you see                                 ELECTRIC SHOCK can kill.
  the symbol, watch out, and follow the related instructions to
                                                                                                Touching live electrical parts can cause fatal shocks
  avoid the hazard. The safety information given below is only                                  or severe burns. The torch and work circuit are
  a summary of the more complete safety information found in                                    electrically live whenever the output is on. The input
  the Safety Standards listed in Section 1-4. Read and follow all                               power circuit and machine internal circuits are also
  Safety Standards.                                                                             live when power is on. Plasma arc cutting requires
                                                                              higher voltages than welding to start and maintain the arc (200 to 400
Y Only qualified persons should install, operate, maintain, and               volts dc are common), but also uses torches designed with safety
  repair this unit.                                                           interlock systems which turn off the machine when the shield cup is
Y During operation, keep everybody, especially children, away.                loosened or if tip touches electrode inside the nozzle. Incorrectly
                                                                              installed or improperly grounded equipment is a hazard.
                                                                              D   Do not touch live electrical parts.
                  CUTTING can cause fire or explosion.
                                                                              D   Wear dry, hole-free insulating gloves and body protection.
                  Hot metal and sparks blow out from the cutting arc.         D   Insulate yourself from work and ground using dry insulating mats or
                  The flying sparks and hot metal, hot workpiece, and             covers big enough to prevent any physical contact with the work or
                  hot equipment can cause fires and burns. Check                  ground.
                  and be sure the area is safe before doing any cutting.
                                                                              D   Do not touch torch parts if in contact with the work or ground.
D   Protect yourself and others from flying sparks and hot metal.             D   Turn off power before checking, cleaning, or changing torch parts.
D   Do not cut where flying sparks can strike flammable material.             D   Disconnect input power before installing or servicing this equip-
D   Remove all flammables within 35 ft (10.7 m) of the cutting arc. If this       ment. Lockout/tagout input power according to OSHA CFR
    is not possible, tightly cover them with approved covers.                     1910.147 (see Safety Standards).
D   Be alert that sparks and hot materials from cutting can easily go         D   Properly install and ground this equipment according to its Owner’s
    through small cracks and openings to adjacent areas.                          Manual and national, state, and local codes.
D   Watch for fire, and keep a fire extinguisher nearby.                      D   Check and be sure that input power cord ground wire is properly
                                                                                  connected to ground terminal in disconnect box or that cord plug is
D   Be aware that cutting on a ceiling, floor, bulkhead, or partition can
                                                                                  connected to a properly grounded receptacle outlet – always verify
    cause fire on the hidden side.
                                                                                  the supply ground.
D   Do not cut on closed containers such as tanks or drums.                   D   When making input connections, attach proper grounding conduc-
D   Connect work cable to the work as close to the cutting area as prac-          tor first.
    tical to prevent cutting current from traveling long, possibly            D   Frequently inspect input power cord for damage or bare wiring – re-
    unknown paths and causing electric shock and fire hazards.
                                                                                  place cord immediately if damaged – bare wiring can kill.
D   Never cut containers with potentially flammable materials inside –
                                                                              D   Turn off all equipment when not in use.
    they must be emptied and properly cleaned first.
                                                                              D   Inspect and replace any worn or damaged torch cable leads.
D   Do not cut in atmospheres containing explosive dust or vapors.
                                                                              D   Do not wrap torch cable around your body.
D   Do not cut pressurized cylinders, pipes, or vessels.
                                                                              D   Ground the workpiece to a good electrical (earth) ground if required
D   Do not cut containers that have held combustibles.
                                                                                  by codes.
D   Wear oil-free protective garments such as leather gloves, heavy
                                                                              D   Use only well-maintained equipment. Repair or replace damaged
    shirt, cuffless trousers, high shoes, and a cap.
                                                                                  parts at once.
D   Do not locate unit on or over combustible surfaces.                       D   Wear a safety harness if working above floor level.
D   Remove any combustibles, such as a butane lighter or matches,             D   Keep all panels and covers securely in place.
    from your person before doing any cutting.




                                                                                                                                    OM-217 Page 1
D     Do not bypass or try to defeat the safety interlock systems.              D   Keep your head out of the fumes. Do not breathe the fumes.
D     Use only torch(es) specified in Owner’s Manual.                           D   If inside, ventilate the area and/or use exhaust at the arc to remove
D     Keep away from torch tip and pilot arc when trigger is pressed.               cutting fumes and gases.
D     Clamp work cable with good metal-to-metal contact to workpiece            D   If ventilation is poor, use an approved air-supplied respirator.
      (not piece that will fall away) or worktable as near the cut as           D   Read the Material Safety Data Sheets (MSDSs) and the manufac-
      practical.                                                                    turer’s instruction for metals to be cut, coatings, and cleaners.
D     Insulate work clamp when not connected to workpiece to prevent            D   Work in a confined space only if it is well ventilated, or while wearing
      contact with any metal object.                                                an air-supplied respirator. Fumes from cutting and oxygen deple-
                                                                                    tion can alter air quality causing injury or death. Be sure the
SIGNIFICANT DC VOLTAGE exists after removal                                         breathing air is safe.
of input power on inverters.                                                    D   Do not cut in locations near degreasing, cleaning, or spraying oper-
                                                                                    ations. The heat and rays of the arc can react with vapors to form
D Turn OFF inverter, disconnect input power, and discharge input                    highly toxic and irritating gases.
  capacitors according to instructions in Maintenance Section
  before touching any parts.                                                    D   Do not cut on coated metals, such as galvanized, lead, or cadmium
                                                                                    plated steel, unless the coating is removed from the cutting area,
                                                                                    the area is well ventilated, and if necessary, while wearing an air-
                    FLYING SPARKS can cause injury.                                 supplied respirator. The coatings and any metals containing these
                                                                                    elements can give off toxic fumes when cut.
                    Sparks and hot metal blow out from the cutting arc.         D   Do not cut containers with toxic or reactive materials inside or
                    Chipping and grinding cause flying metal.                       containers that have held toxic or reactive materials – they must be
                                                                                    emptied and properly cleaned first.
D     Wear approved face shield or safety goggles with side shields.
D     Wear proper body protection to protect skin.
                                                                                                  PLASMA ARC can cause injury.
D     Wear flame-resistant ear plugs or ear muffs to prevent sparks from
      entering ears.                                                                               The heat from the plasma arc can cause serious
                                                                                                   burns. The force of the arc adds greatly to the burn
                                                                                                   hazard. The intensely hot and powerful arc can
                    ARC RAYS can burn eyes and skin.                                               quickly cut through gloves and tissue.
                                                                                D   Keep away from the torch tip.
                    Arc rays from the cutting process produce intense
                    visible and invisible (ultraviolet and infrared) rays       D   Do not grip material near the cutting path.
                    that can burn eyes and skin.                                D   The pilot arc can cause burns – keep away from torch tip when trig-
D     Wear face protection (helmet or shield) with correct shade of filter to       ger is pressed.
      protect your face and eyes when cutting or watching. ANSI Z49.1           D   Wear proper flame-retardant clothing covering all exposed body ar-
      (see Safety Standards) suggests a No. 9 shade (with No. 8 as mini-            eas.
      mum) for all cutting currents less than 300 amperes. Z49.1 adds           D   Point torch away from your body and toward work when pressing
      that lighter filter shades may be used when the arc is hidden by the          the torch trigger – pilot arc comes on immediately.
      workpiece. As this is normally the case with low current cutting, the     D   Turn off power source and disconnect input power before disas-
      shades suggested in Table 1 are provided for the operator’s conve-            sembling torch or changing torch parts.
      nience.
                                                                                D   Use only torch(es) specified in the Owner’s Manual.
D     Wear approved safety glasses with side shields under your helmet
      or shield.
D     Use protective screens or barriers to protect others from flash and                         CYLINDERS can explode if damaged.
      glare; warn others not to watch the arc.
                                                                                                  Gas cylinders contain gas under high pressure. If
D     Wear protective clothing made from durable, flame-resistant                                 damaged, a cylinder can explode. Since gas cylin-
      material (leather and wool) and foot protection.                                            ders are normally part of metalworking processes,
                                                                                                  be sure to treat them carefully.
                                                                                D   Protect compressed gas cylinders from excessive heat, mechani-
           Table 1. Eye Protection For Plasma Arc Cutting                           cal shocks, slag, open flame, sparks, and arcs.
    Current Level In Amperes                   Minimum Shade Number             D   Install and secure cylinders in an upright position by chaining them
                                                                                    to a stationary support or equipment cylinder rack to prevent falling
            Below 20                                    #4
                                                                                    or tipping.
             20 – 40                                    #5
             40 – 60                                    #6                      D   Keep cylinders away from any cutting or other electrical circuits.
             60 – 80                                    #8                      D   Never allow electrical contact between a plasma arc torch and a
                                                                                    cylinder.
                                                                                D   Never cut on a pressurized cylinder – explosion will result.
                                                                                D   Use only correct gas cylinders, regulators, hoses, and fittings de-
                    NOISE can damage hearing.                                       signed for the specific application; maintain them and associated
                                                                                    parts in good condition.
                    Prolonged noise from some cutting applications can
                    damage hearing if levels exceed limits specified by         D   Turn face away from valve outlet when opening cylinder valve.
                    OSHA (see Safety Standards).                                D   Keep protective cap in place over valve except when cylinder is in
                                                                                    use or connected for use.
D     Use approved ear plugs or ear muffs if noise level is high.
                                                                                D   Read and follow instructions on compressed gas cylinders, asso-
D     Warn others nearby about noise hazard.
                                                                                    ciated equipment, and CGA publication P-1 listed in Safety
                                                                                    Standards.
                    FUMES AND GASES can be hazardous.

                    Cutting produces fumes and gases. Breathing
                    these fumes and gases can be hazardous to
                    your health.




OM-217 Page 2
1-3. Additional Symbols for Installation, Operation, and Maintenance

                 HOT PARTS can cause severe burns.                                          FIRE OR EXPLOSION hazard.
                  D Do not touch hot parts bare handed.                                      D Do not locate unit on, over, or near combustible
                  D Allow cooling period before working on torch.                              surfaces.
                                                                                             D Do not install unit near flammables.
                                                                           D Do not overload building wiring – be sure power supply system is
                 MOVING PARTS can cause injury.                              properly sized, rated, and protected to handle this unit.

                  D Keep away from moving parts such as fans.                               STATIC (ESD) can damage PC boards.
                  D Keep all doors, panels, covers, and guards
                    closed and securely in place.                                            D Put on grounded wrist strap BEFORE handling
                                                                                               boards or parts.
                                                                                             D Use proper static-proof bags and boxes to
                 FLYING METAL can injure eyes.                                                 store, move, or ship PC boards.

                  D Wear safety glasses with side shields or face
                    shield.                                                                 H.F. RADIATION can cause interference.
                                                                                             D High frequency (H.F.) can interfere with radio
                 MAGNETIC FIELDS can affect pacemakers.                                        navigation, safety services, computers, and
                                                                                               communications equipment.
                  D Pacemaker wearers keep away.                                             D Have only qualified persons familiar with elec-
                                                                                               tronic equipment perform this installation.
                  D Wearers should consult their doctor before go-
                    ing near plasma arc cutting operations.                D The user is responsible for having a qualified electrician promptly
                                                                             correct any interference problem resulting from the installation.
                                                                           D If notified by the FCC about interference, stop using the equipment
                 OVERUSE can cause OVERHEATING.                              at once.
                                                                           D Have the installation regularly checked and maintained.
                  D Allow cooling period; follow rated duty cycle.
                                                                           D Keep high-frequency source doors and panels tightly shut, keep
                  D Reduce amperage (thickness) or reduce duty               spark gaps at correct setting, and use grounding and shielding to
                    cycle before starting to cut again.                      minimize the possibility of interference.

                                                                                            ARC CUTTING can cause interference.
                 EXPLODING HYDROGEN hazard.
                                                                                             D Electromagnetic energy can interfere with
                  D When cutting aluminum underwater or with the                               sensitive electronic equipment such as
                    water touching the underside of the aluminum,                              computers and computer-driven equipment
                    free hydrogen gas may collect under the work-                              such as robots.
                    piece.
                                                                           D To reduce possible interference, keep cables as short as possible,
D See your cutting engineer and water table instructions for help.           close together, and down low, such as on the floor.
                                                                           D Locate cutting operation 100 meters from any sensitive electronic
                 FALLING UNIT can cause injury.                              equipment.
                                                                           D Be sure this cutting power source is installed and grounded
                  D Use lifting eye to lift unit only, NOT running           according to this manual.
                    gear, gas cylinders, or any other accessories.         D If interference still occurs, the user must take extra measures such
                  D Use equipment of adequate capacity to lift unit.         as moving the machine, using shielded cables, using line filters, or
                                                                             shielding the work area.
D If using lift forks to move unit, be sure forks are long enough to ex-
  tend beyond opposite side of unit.




                                                                                                                               OM-217 Page 3
1-4. Principal Safety Standards

Safety in Welding and Cutting, ANSI Standard Z49.1, from American           Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126                        from Compressed Gas Association, 1235 Jefferson Davis Highway,
                                                                            Suite 501, Arlington, VA 22202.
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.        Code for Safety in Welding and Cutting, CSA Standard W117.2, from
20402.                                                                      Canadian Standards Association, Standards Sales, 178 Rexdale Bou-
                                                                            levard, Rexdale, Ontario, Canada M9W 1R3.
Recommended Practices for Plasma Arc Cutting, American Welding
Society Standard AWS C5.2, from American Welding Society, 550 N.W.          Safe Practices For Occupation And Educational Eye And Face Protec-
LeJeune Rd, Miami, FL 33126                                                 tion, ANSI Standard Z87.1, from American National Standards Institute,
                                                                            1430 Broadway, New York, NY 10018.
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, American            Cutting And Welding Processes, NFPA Standard 51B, from National
Welding Society Standard AWS F4.1, from American Welding Society,           Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
550 N.W. LeJeune Rd, Miami, FL 33126

National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.


1-5. EMF Information
Considerations About Welding Or Cutting And The Effects Of Low              1. Keep cables close together by twisting or taping them.
Frequency Electric And Magnetic Fields
Welding or cutting current, as it flows through the welding or cutting      2. Arrange cables to one side and away from the operator.
cables, will cause electromagnetic fields. There has been and still is
                                                                            3. Do not coil or drape cables around your body.
some concern about such fields. However, after examining more than
500 studies spanning 17 years of research, a special blue ribbon            4. Keep cutting power source and cables as far away from operator
committee of the National Research Council concluded that: “The body
                                                                               as practical.
of evidence, in the committee’s judgment, has not demonstrated that
exposure to power-frequency electric and magnetic fields is a human-        5. Connect work clamp to workpiece as close to the cut as possi-
health hazard.” However, studies are still going forth and evidence            ble.
continues to be examined. Until the final conclusions of the research are
reached, you may wish to minimize your exposure to electromagnetic          About Pacemakers:
fields when welding or cutting.                                             Pacemaker wearers consult your doctor first. If cleared by your doctor,
To reduce magnetic fields in the workplace, use the following proce-        then following the above procedures is recommended.
dures:




OM-217 Page 4
SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT
                      UTILISATION
                                                                                                                                                       pom_fre _nd_4/97


1-1. Signification des symboles
           Signifie Mise en garde ! Soyez vigilant ! Cette procédure
           présente des risques de danger ! Ceux-ci sont identifiés
           par des symboles adjacents aux directives.
Y Identifie un message de sécurité particulier.
                                                                                       Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des ris-
                                                                                       ques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVE-
. Signifie NOTA ; n’est pas relatif à la sécurité.                                     MENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directi-
                                                                                       ves ci-dessous afin de connaître les mesures à prendre pour éviter tout dan-
                                                                                       ger.


1-2. Dangers liés au coupage à l’arc au plasma
Y Les symboles présentés ci-après sont utilisés tout au long du
  présent manuel pour attirer votre attention et identifier les ris-                                       UNE DÉCHARGE ÉLECTRIQUE peut
  ques de danger. Lorsque vous voyez un symbole, soyez                                                     entraîner la mort.
  vigilant et suivez les directives mentionnées afin d’éviter tout
                                                                                                          Le fait de toucher à une pièce électrique sous tension peut
  danger. Les consignes de sécurité présentées ci-après ne font                                           donner une décharge fatale ou entraîner des brûlures
  que résumer l’information contenue dans les normes de sécu-                                             graves. Le chalumeau et le circuit de masse sont
  rité énumérées à la section 1-5. Veuillez lire et respecter toutes                                      automatiquement actifs lorsque le poste est sous tension.
  ces normes de sécurité.                                                              L’alimentation d’entrée et les circuits internes de l’appareil le sont également.
                                                                                       Le coupage au plasma d’arc exige des tensions plus élevées que le soudage
Y L’installation, l’utilisation, l’entretien et les réparations ne                     pour amorcer et maintenir l’arc (souvent de 200 à 400 V CC), c’est pourquoi on
  doivent être confiés qu’à des personnes qualifiées.                                  fait appel à des chalumeaux conçus avec un système de verrouillage
                                                                                       sécuritaire qui met l’appareil hors tension lorsque la capsule anti–feu est
Y Au cours de l’utilisation, tenir toute personne à l’écart et plus                    desserrée ou si le tube touche l’électrode à l’intérieur de la buse. Un poste
                                                                                       incorrectement installé ou inadéquatement mis à la terre constitue un danger.
  particulièrement les enfants.
                                                                                       D   Ne touchez pas aux pièces électriques sous tension.
                                                                                       D   Portez des gants isolants et des vêtements de protection secs et sans
                    LE COUPAGE présente un risque de                                       trous.
                    feu ou d’explosion.                                                D   Isolez–vous de la pièce à couper et du sol en utilisant des housses ou des
                                                                                           tapis assez grands afin d’éviter tout contact physique avec la pièce à cou-
                Des particules de métal chaud et des étincelles peuvent                    per ou le sol.
                jaillir de la pièce au moment du coupage. Les étincelles et le         D   Ne touchez pas aux pièces du chalumeau si vous êtes en contact avec la
                métal chaud, la pièce à couper chauffée et l’équipement                    pièce à couper ou le sol.
                chaud peuvcnt causer un feu ou des brûlures. Avant de
commencer à travailler, assurez–vous que l’endroit est sécuritaire.                    D   Mettez l’appareil hors tension avant d’effectuer la vérification, le nettoyage
                                                                                           ou le changement d’une pièce du chalumeau.
D   Protégez–vous, ainsi que toute autre personne travaillant sur les lieux,           D   Coupez l’alimentation d’entrée avant d’installer l’appareil ou d’effectuer
    contre les étincelles et le métal chaud.                                               l’entretien. Verrouillez ou étiquetez la sortie d’alimentation selon la norme
D   Ne coupez pas dans un endroit où des étincelles pourraient atteindre des               OSHA 29 CFR 1910.147 (reportez–vous aux Principales normes de sécu-
    matières inflammables.                                                                 rité).
D   Déplacez toute matière inflammable se trouvant à l’intérieur d’un périmètre        D   Installez le poste correctement et mettez–le à la terre convenablement se-
    de 10,7 m (35 pi) de la pièce à couper. Si cela est impossible, vous devez             lon les consignes du manuel de l’opérateur et les normes nationales,
    les couvrir avec des housses approuvées et bien ajustées.                              provinciales et locales.
D   Assurez–vous qu’aucune étincelle ni particule de métal ne peut se glisser          D   Assurez–vous que le fil de terre du cordon d’alimentation est correctement
    dans de petites fissures ou tomber dans d’autres pièces.                               relié à la borne de terre dans la boîte de coupure ou que la fiche du cordon
D   Afin d’éliminer tout risque de feu, soyez vigilant et gardez toujours un extinc-       est branchée à une prise correctement mise à la terre – vous devez tou-
    teur à la portée de la main.                                                           jours vérifier la mise à la terre.
D   Si vous coupez sur un plafond, un plancher ou une cloison, soyez conscient         D   Avant d’effectuer les connexions d’alimentation, vous devez relier le bon fil
    que cela peut entraîner un feu de l’autre côté.                                        de terre.
D   Ne coupez pas sur un contenant fermé tel qu’un réservoir ou un bidon.              D   Vérifiez fréquemment le cordon d’alimentation afin de vous assurer qu’il
D   Fixez le câble de masse sur la pièce à couper, le plus près possible de la             n’est pas altéré ou à nu, remplacez–le immédiatement s’il l’est. Un fil à nu
    zone à couper afin de prévenir que le courant de coupage ne prenne une                 peut entraîner la mort.
    trajectoire inconnue ou longue et ne cause ainsi une décharge électrique ou        D   L’équipement doit être hors tension lorsqu’il n’est pas utilisé.
    un feu.                                                                            D   Vérifiez et remplacez les cosses du câble du chalumeau si elles sont usées
D   Ne coupez jamais des contenants qui peuvent contenir des matières inflam-              ou altérées.
    mables. Vous devez en premier lieu les vider et les nettoyer                       D   Le câble du chalumeau ne doit pas s’enrouler autour de votre corps.
    convenablement.                                                                    D   Si les normes le stipulent, la pièce à couper doit être mise à la terre.
D   Ne coupez pas dans un endroit où l’atmosphère risque de contenir de la             D   Utilisez uniquement de l’équipement en bonne condition. Réparez ou rem-
    poussière ou des vapeurs explosives.                                                   placez immédiatement toute pièce altérée.
D   Ne coupez pas de bouteilles, de tuyaux ou de contenants pressurisés.               D   Portez un harnais de sécurité si vous devez travailler au–dessus du sol.
D   Ne coupez pas de contenants qui ont déjà reçu des combustibles.                    D   Assurez–vous que tous les panneaux et couvercles sont correctement en
D   Portez des vêtements de protection exempts d’huile tels que des gants en               place.
    cuir, une veste résistante, des pantalons sans revers, des bottes et un cas-       D   N’essayez pas d’aller à l’encontre des systèmes de verrrouillage de sécuri-
    que.                                                                                   té ou de les contourner.
D   Ne placez pas le poste sur une surface combustible ou au–dessus de celle–          D   Utilisez uniquement le ou les chalumeaux recommandés dans le manuel
    ci.                                                                                    de l’opérateur.
D   Avant le coupage, retirez tout combustible de vos poches, par exemple un
    briquet au butane ou des allumettes.




                                                                                                                                                      OM-217 Page 5
D   N’approchez pas le tube du chalumeau et l’arc pilote lorsque la gâchette est     D   Ne mettez pas votre tête au–dessus des vapeurs. Ne respirez pas ces va-
    enfoncée.                                                                            peurs.
D   Le câble de masse doit être pincé correctement sur la pièce à couper, métal      D   Si vous êtes à l’intérieur au moment du coupage, ventilez la pièce ou ayez
    contre métal (et non de telle sorte qu’il puisse se détacher), ou sur la table       recours à une ventilation aspirante installée près de l’arc pour évacuer les
    de travail le plus près possible de la ligne de coupage.                             vapeurs et les gaz.
D   Isoler la pince de masse quand pas mis à la pièce pour éviter le contact         D   Si la ventilation est médiocre, utilisez un respirateur anti–vapeurs
    avec tout objet métallique.                                                          approuvé.
                                                                                     D   Veuillez lire le Material Safety Data Sheets (MSDS) et les instructions du
Il y a DU COURANT CONTINU IMPORTANT dans                                                 fabricant pour obtenir plus de renseignements sur les métaux à couper, les
les convertisseurs après la suppression de l’ali-                                        enrobages et les nettoyants.
                                                                                     D   Travaillez dans un espace restreint uniquement s’il est bien ventilé ou si
mentation électrique.                                                                    vous portez un respirateur anti–vapeurs. Les vapeurs causées par le cou-
D   Arrêter les convertisseurs, débrancher le courant électrique, et décharger           page et l’épuisement de l’oxygène peuvent altérer la qualité de l’air et
    les condensateurs d’alimentation selon les instructions indiquées dans la            entraîner des blessures ou la mort. Assurez–vous que l’air ambiant est sain
    partie entretien avant de toucher les pièces.                                        pour la santé.
                                                                                     D   Ne coupez pas dans un endroit près d’opérations de décapage, de net-
                    LES ÉTINCELLES VOLANTES ris-                                         toyage ou de vaporisation. La chaleur et les rayons d’arc peuvent réagir
                                                                                         avec les vapeurs et former des gaz hautement toxiques et irritants.
                    quent de provoquer des blessures.                                D   Ne coupez pas des métaux enrobés tels que des métaux galvanisés,
                    Le coupage plasma produit des étincelles et projections de           contenant du plomb ou de l’acier plaqué au cadmium, à moins que l’enroba-
                    métal à très haute température. Lorsque la pièce refroidit,          ge ne soit ôté de la surface du métal à couper, que l’endroit où vous
                    du laitier peut se former.                                           travaillez ne soit bien ventilé, ou, si nécessaire, que vous ne portiez un res-
                                                                                         pirateur anti–vapeurs. Les enrobages ou tous métaux qui contiennent ces
D   Portez une visière ou des lunettes de sécurité avec des écrans latéraux ap-          éléments peuvent créer des vapeurs toxiques s’ils sont coupés.
    prouvées.
                                                                                     D   Ne coupez pas de contenants qui renferment ou ont renfermés des matiè-
D   Portez des vêtements de protection adéquats afin de protéger votre peau.             res toxiques ou réactives – vous devez en premier lieu les vider et les
D   Ayez recours à des protège–tympans ou à un serre–tête ignifuges afin                 nettoyer convenablement.
    d’éviter que les étincelles n’entrent dans vos oreilles.
                                                                                                         LE PLASMA D’ARC peut entraîner
                    LES RAYONS D’ARC peuvent en-                                                         des blessures.
                    traîner des brûlures aux yeux et à la
                    peau.                                                                                La chaleur dégagée par le plasma d’arc peut entraîner de
                                                                                                         sérieuses brûlures. La force de l’arc est un facteur qui
                      Les rayons d’arc provenant du procédé de coupage                                   s’ajoute au danger de brûlures. La chaleur intense et la
                      produisent des rayons visibles et invisibles intenses                              puissance de l’arc peuvent rapidement passer au travers
(ultraviolets et infrarouges) qui peuvent entraîner des brûlures aux yeux et à la                        de gants et de tissus.
peau.                                                                                D   N’approchez pas le tube du chalumeau.
D   Lorsque vous coupez ou regardez quelqu’un couper, portez un masque ou            D   Ne saisissez pas la pièce à couper près de la ligne de coupage.
    un écran facial avec le filtre approprié. La norme ANSI Z49.1 (reportez–         D   L’arc pilote peut causer des brûlures – n’approchez pas le tube du chalu-
    vous aux Principales normes de sécurité) suggère d’utiliser un filtre de             meau lorsque vous avez appuyé sur le gâchette.
    teinte nd 9 (nd 8 étant le minimum) pour tout travail de coupage faisant ap-     D   Portez des vêtements de protection adéquats qui recouvrent tout votre
    pel à un courant de moins de 300 A. On mentionne également dans la                   corps.
    norme Z49.1 qu’un filtre plus faible peut être utilisé lorsque l’arc est caché
    par la pièce à couper. Comme cela est habituellement le cas pour les tra-        D   Ne pointez pas le chalumeau en direction de votre corps ni de la pièce à
    vaux de coupage à faible courant, les teintes énumérées au tableau 1 sont            couper lorsque vous appuyez sur la gâchette – l’arc pilote s’allume automa-
    fournies à titre d’information pour l’opérateur.                                     tiquement.
D   Porter des lunettes de sécurité à coques latérales sous votre casque ou          D   Mettez l’alimentation hors tension et débranchez le cordon d’alimentation
    écran facial.                                                                        avant de démonter le chalumeau ou de changer une pièce du chalumeau.
D   Ayez recours à des écrans protecteurs ou à des rideaux pour protéger les         D   Utilisez uniquement le ou les chalumeaux recommandés dans le manuel
    autres contre les rayonnements et les éblouissements; prévenez toute                 de l’opérateur.
    personne sur les lieux de ne pas regarder l’arc.
D   Portez des vêtements confectionnés avec des matières résistantes et igni-                            LES BOUTEILLES peuvent exploser
    fuges (cuir et laine) et des bottes de protection.
                                                                                                         si elles sont endommagées.
    Tableau 1. Protection des yeux pour le coupage au plasma d’arc                                       Les bouteilles de gaz contiennent du gaz sous haute
                                                                                                         pression. Si une bouteille est endommagée, elle peut
     Intensité de courant en ampères                 Filtre de teinte (minimum)                          exploser. Puisque les bouteilles de gaz font habituellement
                                                                                                         partie d’un processus de travail des métaux, assurez–vous
               Moins de 20                                     no. 4                                     de les manipuler correctement.
                20 – 40                                        no. 5
                                                                                     D   Protégez les bouteilles de gaz comprimé contre la chaleur excessive, les
                40 – 60                                        no. 6
                                                                                         chocs mécaniques, le laitier, la flamme, les étincelles et l’arc.
                60 – 80                                        no. 8
                                                                                     D   Installez et attachez les bouteilles dans la position verticale à l’aide d’une
                                                                                         chaîne, sur un support stationnaire ou un châssis porte–bouteille afin de
                                                                                         prévenir qu’elles ne tombent ou ne basculent.
                    LE BRUIT peut endommager l’ouïe.                                 D   Les bouteilles ne doivent pas être près de la zone de coupage ni de tout
                                                                                         autre circuit électrique.
                    Certaines applications de coupage produisent un bruit            D   Un contact électrique ne doit jamais se produire entre un chalumeau de
                    constant, ce qui peut endommager l’ouïe si le niveau                 plasma d’arc et une bouteille.
                    sonore dépasse les limites permises par l’OSHA (repor-           D   Ne coupez jamais sur une bouteille pressurisée – une explosion en
                    tez–vous aux Principales normes de sécurité).                        résulterait.
D   Utilisez des protège–tympans ou un serre–tête antibruit si le niveau sonore      D   Utilisez uniquement des bouteilles de gaz, des détendeurs, des boyaux et
    est élevé.                                                                           des raccords conçus pour l’application déterminée. Gardez–les, ainsi que
D   Prévenez toute personne sur les lieux du danger relié au bruit.                      toute autre pièce associée, en bonne condition.
                                                                                     D   Détournez votre visage du détendeur–régulateur lorsque vous ouvrez la
                    LES FUMÉES ET LES GAZ peuvent                                        soupape de la bouteille.
                                                                                     D   Le couvercle du détendeur doit toujours être en place, sauf lorsque vous
                    être dangereux.                                                      utilisez la bouteille ou qu’elle est reliée pour usage ultérieur.
                    Le coupage produit des vapeurs et des gaz. Respirer              D   Lisez et suivez les instructions sur les bouteilles de gaz comprimé, l’équi-
                    ces vapeurs et ces gaz peut être dangereux pour la                   pement connexe et le dépliant P–1 de la CGA mentionné dans les
                    santé.                                                               Principales normes de sécurité.




OM-217 Page 6
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
     et la maintenance
                   DES PIECES CHAUDES peuvent pro-                                                    Risque D’INCENDIE OU
                   voquer des brûlures graves.                                                        D’EXPLOSION.
                    D   Ne pas toucher des parties chaudes à mains nues.                               D   Ne pas placer l’appareil sur, au-dessus ou à proximité
                    D   Laisser refroidir avant d’intervenir sur la torche.                                de surfaces infllammables.
                                                                                                       D   Ne pas installer l’appareil à proximité de produits in-
                                                                                                           flammables
                   DES ORGANES MOBILES peuvent                                    D   Ne pas surcharger l’installation électrique – s’assurer que l’alimentation est
                   provoquer des blessures.                                           correctement dimensionné et protégé avant de mettre l’appareil en service.

                    D   S’abstenir de toucher des organes mobiles tels que                            LES CHARGES ÉLECTROSTATI-
                        des ventilateurs.                                                             QUES peuvent endommager les cir-
                    D   Maintenir fermés et verrouillés les portes, panneaux,
                        recouvrements et dispositifs de protection.                                   cuits imprimés.
                                                                                                       D   Etablir la connexion avec la barrette de terre avant de
                   DES PARTICULES VOLANTES                                                                 manipuler des cartes ou des pièces.
                   peuvent blesser les yeux.                                                           D   Utiliser des pochettes et des boîtes antistatiques
                                                                                                           pour stocker, déplacer ou expédier des cartes PC.
                    D   Porter des lunettes de sécurité avec protections laté-
                        rales ou frontales.                                                           LE RAYONNEMENT HAUTE FRÉ-
                                                                                                      QUENCE (H.F.) risque de provoquer
                   LES CHAMPS MAGNÉTIQUES peuv-                                                       des interférences.
                   ent affecter les stimulateurs cardia-
                   ques.                                                                               D   Le Rayonnement haute frequence (H.F.) peut provo-
                                                                                                           quer des interférences avec les équipements de ra-
                    D   Porteurs de stimulateur cardiaque, restez à distance.                              dio–navigation et de communication, les services de
                                                                                                           sécurité et les ordinateurs.
                    D   Les porteurs sont priés de consulter leur médecin
                        avant d’approcher les opérations de coupage               D   Demander seulement à des personnes qualifiées familiarisées avec des
                        plasma.                                                       équipements électroniques de faire fonctionner l’installation.
                                                                                  D   L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié
                                                                                      les interférences résultant de l’installation.
                   L’EMPLOI EXCESSIF peut
                                                                                  D   Si le FCC signale des interférences, arrêter immédiatement l’appareil.
                   SURCHAUFFER L’ÉQUIPEMENT.                                      D   Effectuer régulièrement le contrôle et l’entretien de l’installation.
                                                                                  D   Maintenir soigneusement fermés les portes et les panneaux des sources
                    D   Prévoir une période de refroidissement; respecter le          de haute fréquence, maintenir les éclateurs à une distance correcte et utili-
                        cycle opératoire nominal.                                     ser une terre et et un blindage pour réduire les interférences éventuelles.
                    D   Réduire l’ampérage (épaisseur) avant de continuer à
                        couper ou réduire le facteur de marche.                                       LE COUPAGE Ã L’ARC peut causer
                                                                                                      des interférence.
                   Danger   D’EXPLOSION                                D’HY-
                   DROGÈNE.                                                                            D    L’énergie électromagnétique peut gêner le fonction-
                                                                                                            nement d’appareils électroniques comme des ordi-
                                                                                                            nateurs et des robots.
                    D   Lors du coupage d’aluminium partiellement ou totale-
                        ment immergé dans l’eau, de l’hydrogène libre peut        D   Pour réduire la possibilité d’interférence, maintenir les câbles aussi courts
                        s’accumuler sous la pièce.                                    que possible, les grouper, et les poser aussi bas que possible (ex. par
                    D   Consultez votre ingénieur de coupage et les instruc-          terre).
                        tions de la table de coupage.                             D   Veiller à couper à une distance de 100 mètres de tout équipement électroni-
                                                                                      que sensible.
                                                                                  D   S’assurer que la source de coupage est correctement branchée et mise à
                   LA CHUTE DE L’APPAREIL peut                                        la terre.
                   blesser.                                                       D   Si l’interférence persiste, l’utilisateur doit prendre des mesures supplémen-
                                                                                      taires comme écarter la machine, utiliser des câbles blindés de des filtres,
                    D    Utiliser l’anneau de levage uniquement pour soulever         ou boucler la zone de travail.
                         l’appareil, NON PAS les chariot, les bouteilles de gaz
                         ou tout autre accessoire.
                     D Utiliser un engin d’une capacité appropriée pour sou-
                         lever l’appareil.
 D   En utilisant des fourches de levage pour déplacer l’unité, s’assurer que
     les fourches sont suffisamment longues pour dépasser du côté opposé
     de l’appareil.


1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-               Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126                                 de la Compressed Gas Association, 1235 Jefferson Davis Highway,
                                                                                  Suite 501, Arlington, VA 22202.
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.                   Règles de sécurité en soudage, coupage et procédés connexes, norme
20402.                                                                            CSA W117.2, de l’Association canadienne de normalisation, vente de
                                                                                  normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS                 Safe Practices For Occupation And Educational Eye And Face Protec-
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL                tion, norme ANSI Z87.1, de l’American National Standards Institute,
33126                                                                             1430 Broadway, New York, NY 10018.
National Electrical Code, NFPA Standard 70, de la National Fire Protec-           Cutting and Welding Processes, norme NFPA 51B, de la National Fire
tion Association, Batterymarch Park, Quincy, MA 02269.                            Protection Association, Batterymarch Park, Quincy, MA 02269.



                                                                                                                                                 OM-217 Page 7
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,      Afin de réduire les champs électromagnétiques dans l’environnement
des champs magnétiques basse fréquence                                      de travail, respecter les consignes suivantes :
L’extrait suivant est tiré des conclusions générales du document intitulé   1   Garder les câbles ensembles en les torsadant ou en les
Biological Effects of Power Frequency Electric & Magnetic Fields –              attachant avec du ruban adhésif.
Background Paper, OTA–BP–E–53 (Washington DC : U.S. Govern-                 2   Mettre tous les câbles du côté opposé de l’opérateur.
ment Printing Office, mai 1989), publié par le Office of Technology
Assessment du Congrès américain : «... il existe maintenant d’abon-         3   Ne pas courber pas et ne pas entourer pas les câbles autour de
dantes données scientifiques compilées à la suite d’expériences sur la          vous.
cellule ou d’études sur des animaux et des humains, qui montrent clai-      4   Garder le poste de soudage et les câbles le plus loin possible de
rement que les champs électromagnétiques basse fréquence peuvent                vous.
avoir des effets sur l’organisme et même y produire des transforma-         5   Relier la pince de masse le plus près possible de la zone de
tions. Même s’il s’agit de travaux de très grande qualité, les résultats        soudure.
sont complexes. Cette démarche scientifique ne nous permet pas
d’établir un tableau d’ensemble cohérent. Pire encore, elle ne nous per-    Consignes relatives aux stimulateurs cardiaques :
met pas de tirer des conclusions finales concernant les risques             Les consignes mentionnées précédemment font partie de celles desti-
éventuels, ni d’offrir des conseils sur les mesures à prendre pour rédui-   nées aux personnes ayant recours à un stimulateur cardiaque. Veuillez
re sinon éliminer les risques éventuels». (Traduction libre)                consulter votre médecin pour obtenir plus de détails.




OM-217 Page 8
SECTION 2 – DEFINITIONS
2-1. Warning Label Definitions

                                                                              Warning! Watch Out! There are
                                                                              possible hazards as shown by the
                                                                              symbols.
                                                                              1     Cutting sparks can cause
                                                                                    explosion or fire.
                                                                              1.1   Keep flammables away from
                                                                                    cutting. Do not cut near
                                                                                    flammables.
                                                                              1.2   Cutting sparks can cause
                                                                                    fires. Have a fire extinguisher
  1           1.1                   1.2                     1.3                     nearby, and have a
                                                                                    watchperson ready to use it.
                                                                              1.3   Do not cut on drums or any
                                                                                    closed containers.
                                                                              2     The plasma arc can cause
                                                                                    injury and burns.
                                                                              2.1   Turn off power before
  2                                                                                 disassembling torch.
               2.1           2.2                    2.3
                                                                              2.2   Do not grip material near
                                                                                    cutting path.
                                                                              2.3   Wear complete body
                                                                                    protection.
                                                                              3     Electric shock from torch or
                                                                                    wiring can kill.
                                                                              3.1   Wear dry insulating gloves.
  3            3.1                 3.2                    3.3
                                                                                    Do not wear wet or damaged
                                                                                    gloves.
                                                                              3.2   Protect yourself from electric
                                                                                    shock by insulating yourself
                                                                                    from work and ground.
                                                                              3.3   Disconnect input plug or
                                                                                    power before working on
  4            4.1         4.2                4.3                                   machine.
                                                                              4     Breathing cutting fumes can
                                                                                    be hazardous to your health.
                                                                              4.1   Keep your head out of the
                                                                                    fumes.
                                                                              4.2   Use forced ventilation or local
                                                                                    exhaust to remove the fumes.
  5            5.1                                                            4.3   Use ventilating fan to remove
                                                                                    fumes.
                                                                              5     Arc rays can burn eyes and
                       +                  +         +                         5.1
                                                                                    injure skin.
                                                                                    Wear hat and safety glasses.
                                                                                    Use ear protection and button
                                                                                    shirt collar. Use welding
                                                                                    helmet with correct shade of
  6                                                        7                        filter. Wear complete body
                                                                                    protection.

             +                                                                6     Become trained and read the
                                                                                    instructions before working on
                                                                                    the machine or cutting.
                                                                              7     Do not remove or paint over
                                                                                    (cover) the label.
                                                                  S-179 219




                                                                                                                 1/96



                                                                                                     OM-217 Page 9
Warning! Watch Out! There are
                                                                                    possible hazards as shown by the
                                                                                    symbols.

                                                                                    Electric shock from wiring can kill.

                                                                                    Disconnect input plug or power
                                                                                    before working on machine.
                                                                                    Read the Owner’s Manual before
                                                                                    working on this machine.
                                                                                    1   Consult rating label for input
                                                                                        power requirements, and
                                                                                        check power available at the
                                                                                        job site – they must match.
                                                                                    2   Read Owner’s Manual and
                                                                                        inside labels for connection
                                                                                        points and procedures.
                                                                                    3   Move jumper links as shown
                                                                                        on inside label to match
                                                ?   V                                   voltage at job site.
    1                        2             3
                                                                                    4   Having a loop of extra length,
                                                                                        connect grounding conductor
                                                                                        first.
                 ?   V                                                              5   Connect line input conductors
                                                                                        as shown on inside label –
                 ?   A                                              5
                                                                                        double-check all connections,
                                                                                        jumper link positions, and
                                       ÍÍÍ                                              input voltage before applying
                             ÍÍÍ
                             ÍÍÍ       ÍÍÍ
                                       ÍÍÍ
                                                        3                               power.


                                       4
                                                                        S-179 290




                                                                                                                     1/96




                                                                                    1   Input connection point for
                                                                                        nitrogen gas.
                         2                                      3                   2   Input connection point for
                                                                                        compressed air.
                                                                                    3   Air/gas pressure adjustment
                                                                                        control with recommended
                                                                                        setting.




                                           –                +
                                   N            70 psi

                                           (    4.8 bar
                                               483 kPa      )
                                                            S-175 971




                             1
                                                                                                                     1/96


OM-217 Page 10
2-2. Manufacturer’s Rating Label For CE Products


             Match label to one on
             unit. See Section 3-4.


                       100 Ampere Model                                        70 Ampere Model




     3                                                         3
                                      EN 60974-1                                             EN 60974-1



                            30A/120V          100A/120V                            30A/120V       70A/120V

                            X          80%         100%                            X                   100%

                            I2         100A         80A                            I2                   70A
               U0 = 270V                                               U0 = 270V
                            U2         120V        120V                            U2                  120V




               U1       V        I1                                    U1      V        I1
         3     220V                   78A           64A            3   220V                             57A
               380V                   45A           37A                380V                             33A
               415V                   41A           34A                415V                             30A
               50 Hz                                                   50 Hz

                            IP 21S                                                 IP 21S             Drawing #




                                                 S-174 462-A                                         S-174 463-A




                                                                                                     OM-217 Page 11
2-3. Symbols And Definitions


   NOTE                                Some symbols are found only on CE products.



   A                Amperes
                                                    Plasma Arc Cutting
                                                         (PAC)
                                                                                                 Trigger Hold On                         Trigger Hold Off



   V                    Volts                           Pilot/Pulse Starting
                                                                                                 Continuous Pilot
                                                                                                       Arc
                                                                                                                                              Pulse


                                                                                                 No – Do Not Do
                     Output                                  Increase                                                                      Temperature
                                                                                                      This


                 Protective Earth
                                                           Three Phase                           High Frequency                               Input
                    (Ground)



                        On                                      Off                                  Percent                              Direct Current




    U0           Rated No Load
                Voltage (Average)        U1              Primary Voltage
                                                                                U2           Conventional Load
                                                                                                 Voltage
                                                                                                                                         Line Connection


                                                                                                                                          Three Phase
    I1           Primary Current
                                          I2              Rated Welding
                                                             Current              X                 Duty Cycle                            Transformer
                                                                                                                                            Rectifier



   IP              Degree Of
                   Protection
                                                        Loose Shield Cup
                                                                                                   Torch-Tip-To
                                                                                                  Electrode Short         Hz                  Hertz



                Air/Gas Pressure                                                              Low Air Pressure                          Nitrogen Gas Input
                                                               Work
                   Adjustment                                                                      Light                                    Connection


                 Adjust Air/Gas
                   Pressure




                                      SECTION 3 – INSTALLATION
3-1. Specifications


                                Amperes Input at Rated Output,                                                       Plasma
   Model/                         50 or 60 Hz, Three-Phase                                                             Gas
   Rated                                                                                                     Plasma   Flow/               Max       IP
   Output        200 V 220 V 230 V 380 V 415 V 460 V 575 V                              KVA          KW       Gas   Pressure              OCV     Rating
   1000 / 70
  Amperes At
                               57       54       33          30         27       22       21          10
 108 Volts DC      ––
                             (4.0*)   (2.6*)   (2.5*)      (1.5*)     (1.3*)   (1.0*)   (1.04*)     (0.6*)
   At 100%                                                                                                                   7 CFM
  Duty Cycle                                                                                                    Air Or                    270
                                                                                                                          (198 L/min)
                                                                                                               Nitrogen                   Volts       21S
   1250 / 100                                                                                                              At 70 PSI
                                                                                                                Only                       DC
  Amperes At                                                                                                               (482 kPa)
                    85         77       74       45          41         37       30       30          16
 120 Volts DC
                  (3.4*)     (4.0*)   (2.9*)   (2.5*)      (1.5*)     (1.5*)   (1.0*)   (1.2*)      (0.5*)
 At 80% Duty
     Cycle
*While idling

OM-217 Page 12
3-2. Duty Cycle And Overheating
                                                                               Duty Cycle is percentage of 10 min-
                 70 Ampere Models: 100% Duty Cycle At 70 Amperes               utes that unit can cut at rated load
                                                                               without overheating.
                                                                               If unit overheats, thermostat(s)
                                                                               opens, output stops, Temperature
                                                                               trouble light goes On, and cooling
                                                                               fan runs. Wait fifteen minutes for
                                                                               unit to cool or temperature light to
                                                                               go off. Reduce amperage or duty
                                   Continuous Welding                          cycle before cutting or gouging.
                                                                               Y Exceeding duty cycle can
                     100 Ampere Models: 80% Duty Cycle At 100 Amperes            damage unit and void
                                                                                 warranty.




                      8 Minutes Welding                 2 Minutes Resting


  Overheating


                                                                                     A


                                      0


                                             15
                                                                                   OR
                                   Minutes                                   Reduce Duty Cycle

                                                                                          duty1 4/95 – Ref. ST-159 463-B



3-3. Cutting Speed
                                                                               The cutting speed curves show the
                                                                               recommended maximum cutting
                                                                               speed capabilities of the power
                                                                               source and torch for mild steel of
                                                                               various thickness.
                                                                               Cut at speeds below the lines
                                                                               shown to avoid poor cuts and torch
                                                                               wear.




                70 Ampere Model                                             100 Ampere Model




                                                                                                ST-171 819 / ST-171 820


                                                                                                     OM-217 Page 13
3-4. Selecting A Location
                                                                          1    Lift Hook
                                                                          Install lift hooks using supplied
                                                                          bolts. Tighten to 25 ft/lb (34 N·m).
        Movement                                                          2    Spreader Bar (Not Supplied)
                                                                          3    Lifting Cable (Not Supplied)
                                                                          If lifting unit, use spreader and
                           3                                              cable.
            2                                                             4    Lifting Eye
                                                                          5    Lifting Forks
                                                                          If using lifting forks, extend forks
            1                                                             beyond opposite side of unit.
                                            4
                                                                          6    Rating Label (Non CE Models
                                                                               Only)
                                                                          7    Rating Label (CE Models
                                                                               Only, See Section 2-2)
                                                                          Use rating label to determine input
                                                OR
                                                                          power needs.
                                                                      5
                                                                          8    Plate Label (CE Models Only)
                                                                          9    Line Disconnect Device
                                                                          Locate unit near correct input pow-
                                                                          er supply.

    Location And Airflow                                                  Y Special installation may be
                                                                            required where gasoline or
       6                                                    9               volatile liquids are present –
                                                                            see NEC Article 511 or CEC
                                                                            Section 20.




        8                                            7
                                                         18 in (460
                                                           mm)




                               18 in (460
                                 mm)                                          S-0439 / Ref. ST-800 402-B / ST-159 463-B




OM-217 Page 14
3-5. Dimensions And Weight
                                                                                Dimensions

                                                                    Height           37-1/4 in (946 mm)

                      A                                             Width            22-3/4 in (578 mm)
                      B
                                                                    Length             20 in (508 mm)
                                         C
                                                                      A             22-1/16 in (560 mm)

                                                                      B             21-1/32 in (210 mm)
                                                 D
                                                                      C              1-1/32 in (26 mm)

                                             E                        D             18-13/16 in (478 mm)

                                                                      E              17-11/16 (449 mm)

                                                                      F               5-5/8 (143 mm)
                                         F
                                                                      G                1-1/8 (29 mm)
                  Bottom Front
                                 H                                    H             7/16 in (11 mm) Dia
                                     G               ST-159 464-B

                                                                                   Weight

                                                                               405 lbs (184 kg)


3-6. Tipping
                                                                             Y Be careful when placing or
                                                                               moving unit over uneven
                                                                               surfaces.




                                                                                                  OM-217 Page 15
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L
Manual L

Contenu connexe

Similaire à Manual L

hipath_3000_man.pdf
hipath_3000_man.pdfhipath_3000_man.pdf
hipath_3000_man.pdf
fellahi1
 
Twido guide materiel base extreme
Twido guide materiel   base extremeTwido guide materiel   base extreme
Twido guide materiel base extremeJohanna Mesa Torres
 
ATV630_650_Installation_manual_FR_EAV64302_10.pdf
ATV630_650_Installation_manual_FR_EAV64302_10.pdfATV630_650_Installation_manual_FR_EAV64302_10.pdf
ATV630_650_Installation_manual_FR_EAV64302_10.pdf
kaoutarelchhab
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
fjjskekdmmse
 
Altair 4x manual en fr es
Altair 4x manual   en fr esAltair 4x manual   en fr es
Altair 4x manual en fr es
Carlos Alberto Flores
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
idkkddmmd1
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
fhsjejkdmem
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
fjjsekdmme
 
Twido guide materiel bases compactes & modulaires
Twido guide materiel   bases compactes & modulairesTwido guide materiel   bases compactes & modulaires
Twido guide materiel bases compactes & modulairesJohanna Mesa Torres
 
19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf
19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf
19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf
Drm/Bss Gueda
 
JLG TOUCAN 10E (Manuel d'utilisation )
JLG TOUCAN 10E (Manuel d'utilisation   )JLG TOUCAN 10E (Manuel d'utilisation   )
JLG TOUCAN 10E (Manuel d'utilisation )
MrDIAGAUTO
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
fjsekkxszdmmem
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
fjsekdhjenmdn
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
fjsekdhjenmdn
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
kmdddmm
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
kmdddmm
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
fjsekkxszdmmem
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
fjsekksmemm
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
fjsekksmemm
 
Crown gpc2000 sl series lift truck parts catalogue manual
Crown gpc2000 sl series lift truck parts catalogue manualCrown gpc2000 sl series lift truck parts catalogue manual
Crown gpc2000 sl series lift truck parts catalogue manual
fjjskekmdmme
 

Similaire à Manual L (20)

hipath_3000_man.pdf
hipath_3000_man.pdfhipath_3000_man.pdf
hipath_3000_man.pdf
 
Twido guide materiel base extreme
Twido guide materiel   base extremeTwido guide materiel   base extreme
Twido guide materiel base extreme
 
ATV630_650_Installation_manual_FR_EAV64302_10.pdf
ATV630_650_Installation_manual_FR_EAV64302_10.pdfATV630_650_Installation_manual_FR_EAV64302_10.pdf
ATV630_650_Installation_manual_FR_EAV64302_10.pdf
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
 
Altair 4x manual en fr es
Altair 4x manual   en fr esAltair 4x manual   en fr es
Altair 4x manual en fr es
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
 
Crown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manualCrown tc3000 tow truck parts catalogue manual
Crown tc3000 tow truck parts catalogue manual
 
Twido guide materiel bases compactes & modulaires
Twido guide materiel   bases compactes & modulairesTwido guide materiel   bases compactes & modulaires
Twido guide materiel bases compactes & modulaires
 
19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf
19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf
19134742-Hi-Path-3000-V1-2-3-0-Manuel-de-Service-1.pdf
 
JLG TOUCAN 10E (Manuel d'utilisation )
JLG TOUCAN 10E (Manuel d'utilisation   )JLG TOUCAN 10E (Manuel d'utilisation   )
JLG TOUCAN 10E (Manuel d'utilisation )
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
 
Fiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manualFiat kobelco sl40 b skid steer loader service repair manual
Fiat kobelco sl40 b skid steer loader service repair manual
 
Fiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manualFiat kobelco sl35 b skid steer loader service repair manual
Fiat kobelco sl35 b skid steer loader service repair manual
 
Crown gpc2000 sl series lift truck parts catalogue manual
Crown gpc2000 sl series lift truck parts catalogue manualCrown gpc2000 sl series lift truck parts catalogue manual
Crown gpc2000 sl series lift truck parts catalogue manual
 

Manual L

  • 1. OM-217 168 808F October 1998 Processes Air Plasma Cutting and Gouging Description Air Plasma Cutter Spectrum 1000 And 1250 R Visit our website at www.MillerWelds.com
  • 2. From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929. Working as hard as you This Owner’s Manual is designed to help you get the most out of your do – every power source from Miller is backed by Miller products. Please take time to read the Safety precautions. They will the most hassle-free war- help you protect yourself against potential hazards on the worksite. We’ve ranty in the business. made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you Miller is the first welding figure out what the problem is. The parts list equipment manufacturer in will then help you to decide which exact part the U.S.A. to be registered to the ISO 9001 Quality you may need to fix the problem. Warranty and System Standard. service information for your particular model are also provided. Miller offers a Technical Manual which provides more detailed service and parts information for your unit. To obtain a Technical Manual, contact your local distributor. Your distributor can also supply you with Welding Process Manuals such as SMAW, GTAW, GMAW, and GMAW-P. Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. To locate your nearest distributor call 1-800-4-A-Miller.
  • 3. TABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2. Plasma Arc Cutting Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . 3 1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . 5 1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1-2. Dangers liés au coupage à l’arc au plasma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2-2. Manufacturer’s Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3-2. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3-3. Cutting Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3-4. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3-5. Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3-6. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3-7. Connecting Work Clamp And Gas/Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3-8. Remote Control Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3-9. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3-10. Placing Jumper Links And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 5-2. Overload Protection: Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 5-3. Overload Protection: Trouble Lights & Checking Shield Cup Shutdown System . . . . . . . . . . 23 5-4. Adjusting Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 5-5. Torch And Work Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5-6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 SECTION 6 – ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 SECTION 7 – HF IN PLASMA CUTTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 7-1. High Frequency In Plasma Arc Cutting (PAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 7-2. Sources Of High-Frequency Radiation From Incorrect Installation . . . . . . . . . . . . . . . . . . . . . 30 7-3. Correct Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 SECTION 8 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 WARRANTY
  • 4. Declaration of Conformity For European Community (CE) Products NOTE This information is provided for units with CE certification (see rating label on unit.) Manufacturer’s Name: Miller Electric Mfg. Co. Manufacturer’s Address: 1635 W. Spencer Street Appleton, WI 54914 USA Declares that the product: Spectrum 1000 &1250 conforms to the following Directives and Standards: Directives Low Voltage Directive: 73/23/EEC Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC Electromagnetic Compatibility Directives: 89/336/EEC, 92/31/EEC Standards Arc Welding Equipment, Plasma Cutting Systems: prEN 50192: 1995 Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1990 Arc Welding Equipment Part 1: Welding Power Sources: IEC 974-1 (April 1995 – Draft revision) Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989 Insulation coordination for equipment within low-voltage systems: Part 1: Principles, requirements and tests: IEC 664-1: 1992 Electromagnetic compatibility (EMC) Product standard for arc welding equipment: EN50199: August 1995 European Contact: Mr. Luigi Vacchini, Managing Director MILLER Europe S.P.A. Via Privata Iseo 20098 San Giuliano Milanese, Italy Telephone: 39(02)98290-1 Fax: 39(02)98281-552 dec_con1 10/95
  • 5. SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING pom _nd_5/97 1-1. Symbol Usage Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. . Means “Note”; not safety related. Consult symbols and related instructions below for necessary actions to avoid the hazards. 1-2. Plasma Arc Cutting Hazards Y The symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see ELECTRIC SHOCK can kill. the symbol, watch out, and follow the related instructions to Touching live electrical parts can cause fatal shocks avoid the hazard. The safety information given below is only or severe burns. The torch and work circuit are a summary of the more complete safety information found in electrically live whenever the output is on. The input the Safety Standards listed in Section 1-4. Read and follow all power circuit and machine internal circuits are also Safety Standards. live when power is on. Plasma arc cutting requires higher voltages than welding to start and maintain the arc (200 to 400 Y Only qualified persons should install, operate, maintain, and volts dc are common), but also uses torches designed with safety repair this unit. interlock systems which turn off the machine when the shield cup is Y During operation, keep everybody, especially children, away. loosened or if tip touches electrode inside the nozzle. Incorrectly installed or improperly grounded equipment is a hazard. D Do not touch live electrical parts. CUTTING can cause fire or explosion. D Wear dry, hole-free insulating gloves and body protection. Hot metal and sparks blow out from the cutting arc. D Insulate yourself from work and ground using dry insulating mats or The flying sparks and hot metal, hot workpiece, and covers big enough to prevent any physical contact with the work or hot equipment can cause fires and burns. Check ground. and be sure the area is safe before doing any cutting. D Do not touch torch parts if in contact with the work or ground. D Protect yourself and others from flying sparks and hot metal. D Turn off power before checking, cleaning, or changing torch parts. D Do not cut where flying sparks can strike flammable material. D Disconnect input power before installing or servicing this equip- D Remove all flammables within 35 ft (10.7 m) of the cutting arc. If this ment. Lockout/tagout input power according to OSHA CFR is not possible, tightly cover them with approved covers. 1910.147 (see Safety Standards). D Be alert that sparks and hot materials from cutting can easily go D Properly install and ground this equipment according to its Owner’s through small cracks and openings to adjacent areas. Manual and national, state, and local codes. D Watch for fire, and keep a fire extinguisher nearby. D Check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is D Be aware that cutting on a ceiling, floor, bulkhead, or partition can connected to a properly grounded receptacle outlet – always verify cause fire on the hidden side. the supply ground. D Do not cut on closed containers such as tanks or drums. D When making input connections, attach proper grounding conduc- D Connect work cable to the work as close to the cutting area as prac- tor first. tical to prevent cutting current from traveling long, possibly D Frequently inspect input power cord for damage or bare wiring – re- unknown paths and causing electric shock and fire hazards. place cord immediately if damaged – bare wiring can kill. D Never cut containers with potentially flammable materials inside – D Turn off all equipment when not in use. they must be emptied and properly cleaned first. D Inspect and replace any worn or damaged torch cable leads. D Do not cut in atmospheres containing explosive dust or vapors. D Do not wrap torch cable around your body. D Do not cut pressurized cylinders, pipes, or vessels. D Ground the workpiece to a good electrical (earth) ground if required D Do not cut containers that have held combustibles. by codes. D Wear oil-free protective garments such as leather gloves, heavy D Use only well-maintained equipment. Repair or replace damaged shirt, cuffless trousers, high shoes, and a cap. parts at once. D Do not locate unit on or over combustible surfaces. D Wear a safety harness if working above floor level. D Remove any combustibles, such as a butane lighter or matches, D Keep all panels and covers securely in place. from your person before doing any cutting. OM-217 Page 1
  • 6. D Do not bypass or try to defeat the safety interlock systems. D Keep your head out of the fumes. Do not breathe the fumes. D Use only torch(es) specified in Owner’s Manual. D If inside, ventilate the area and/or use exhaust at the arc to remove D Keep away from torch tip and pilot arc when trigger is pressed. cutting fumes and gases. D Clamp work cable with good metal-to-metal contact to workpiece D If ventilation is poor, use an approved air-supplied respirator. (not piece that will fall away) or worktable as near the cut as D Read the Material Safety Data Sheets (MSDSs) and the manufac- practical. turer’s instruction for metals to be cut, coatings, and cleaners. D Insulate work clamp when not connected to workpiece to prevent D Work in a confined space only if it is well ventilated, or while wearing contact with any metal object. an air-supplied respirator. Fumes from cutting and oxygen deple- tion can alter air quality causing injury or death. Be sure the SIGNIFICANT DC VOLTAGE exists after removal breathing air is safe. of input power on inverters. D Do not cut in locations near degreasing, cleaning, or spraying oper- ations. The heat and rays of the arc can react with vapors to form D Turn OFF inverter, disconnect input power, and discharge input highly toxic and irritating gases. capacitors according to instructions in Maintenance Section before touching any parts. D Do not cut on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the cutting area, the area is well ventilated, and if necessary, while wearing an air- FLYING SPARKS can cause injury. supplied respirator. The coatings and any metals containing these elements can give off toxic fumes when cut. Sparks and hot metal blow out from the cutting arc. D Do not cut containers with toxic or reactive materials inside or Chipping and grinding cause flying metal. containers that have held toxic or reactive materials – they must be emptied and properly cleaned first. D Wear approved face shield or safety goggles with side shields. D Wear proper body protection to protect skin. PLASMA ARC can cause injury. D Wear flame-resistant ear plugs or ear muffs to prevent sparks from entering ears. The heat from the plasma arc can cause serious burns. The force of the arc adds greatly to the burn hazard. The intensely hot and powerful arc can ARC RAYS can burn eyes and skin. quickly cut through gloves and tissue. D Keep away from the torch tip. Arc rays from the cutting process produce intense visible and invisible (ultraviolet and infrared) rays D Do not grip material near the cutting path. that can burn eyes and skin. D The pilot arc can cause burns – keep away from torch tip when trig- D Wear face protection (helmet or shield) with correct shade of filter to ger is pressed. protect your face and eyes when cutting or watching. ANSI Z49.1 D Wear proper flame-retardant clothing covering all exposed body ar- (see Safety Standards) suggests a No. 9 shade (with No. 8 as mini- eas. mum) for all cutting currents less than 300 amperes. Z49.1 adds D Point torch away from your body and toward work when pressing that lighter filter shades may be used when the arc is hidden by the the torch trigger – pilot arc comes on immediately. workpiece. As this is normally the case with low current cutting, the D Turn off power source and disconnect input power before disas- shades suggested in Table 1 are provided for the operator’s conve- sembling torch or changing torch parts. nience. D Use only torch(es) specified in the Owner’s Manual. D Wear approved safety glasses with side shields under your helmet or shield. D Use protective screens or barriers to protect others from flash and CYLINDERS can explode if damaged. glare; warn others not to watch the arc. Gas cylinders contain gas under high pressure. If D Wear protective clothing made from durable, flame-resistant damaged, a cylinder can explode. Since gas cylin- material (leather and wool) and foot protection. ders are normally part of metalworking processes, be sure to treat them carefully. D Protect compressed gas cylinders from excessive heat, mechani- Table 1. Eye Protection For Plasma Arc Cutting cal shocks, slag, open flame, sparks, and arcs. Current Level In Amperes Minimum Shade Number D Install and secure cylinders in an upright position by chaining them to a stationary support or equipment cylinder rack to prevent falling Below 20 #4 or tipping. 20 – 40 #5 40 – 60 #6 D Keep cylinders away from any cutting or other electrical circuits. 60 – 80 #8 D Never allow electrical contact between a plasma arc torch and a cylinder. D Never cut on a pressurized cylinder – explosion will result. D Use only correct gas cylinders, regulators, hoses, and fittings de- NOISE can damage hearing. signed for the specific application; maintain them and associated parts in good condition. Prolonged noise from some cutting applications can damage hearing if levels exceed limits specified by D Turn face away from valve outlet when opening cylinder valve. OSHA (see Safety Standards). D Keep protective cap in place over valve except when cylinder is in use or connected for use. D Use approved ear plugs or ear muffs if noise level is high. D Read and follow instructions on compressed gas cylinders, asso- D Warn others nearby about noise hazard. ciated equipment, and CGA publication P-1 listed in Safety Standards. FUMES AND GASES can be hazardous. Cutting produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. OM-217 Page 2
  • 7. 1-3. Additional Symbols for Installation, Operation, and Maintenance HOT PARTS can cause severe burns. FIRE OR EXPLOSION hazard. D Do not touch hot parts bare handed. D Do not locate unit on, over, or near combustible D Allow cooling period before working on torch. surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is MOVING PARTS can cause injury. properly sized, rated, and protected to handle this unit. D Keep away from moving parts such as fans. STATIC (ESD) can damage PC boards. D Keep all doors, panels, covers, and guards closed and securely in place. D Put on grounded wrist strap BEFORE handling boards or parts. D Use proper static-proof bags and boxes to FLYING METAL can injure eyes. store, move, or ship PC boards. D Wear safety glasses with side shields or face shield. H.F. RADIATION can cause interference. D High frequency (H.F.) can interfere with radio MAGNETIC FIELDS can affect pacemakers. navigation, safety services, computers, and communications equipment. D Pacemaker wearers keep away. D Have only qualified persons familiar with elec- tronic equipment perform this installation. D Wearers should consult their doctor before go- ing near plasma arc cutting operations. D The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation. D If notified by the FCC about interference, stop using the equipment OVERUSE can cause OVERHEATING. at once. D Have the installation regularly checked and maintained. D Allow cooling period; follow rated duty cycle. D Keep high-frequency source doors and panels tightly shut, keep D Reduce amperage (thickness) or reduce duty spark gaps at correct setting, and use grounding and shielding to cycle before starting to cut again. minimize the possibility of interference. ARC CUTTING can cause interference. EXPLODING HYDROGEN hazard. D Electromagnetic energy can interfere with D When cutting aluminum underwater or with the sensitive electronic equipment such as water touching the underside of the aluminum, computers and computer-driven equipment free hydrogen gas may collect under the work- such as robots. piece. D To reduce possible interference, keep cables as short as possible, D See your cutting engineer and water table instructions for help. close together, and down low, such as on the floor. D Locate cutting operation 100 meters from any sensitive electronic FALLING UNIT can cause injury. equipment. D Be sure this cutting power source is installed and grounded D Use lifting eye to lift unit only, NOT running according to this manual. gear, gas cylinders, or any other accessories. D If interference still occurs, the user must take extra measures such D Use equipment of adequate capacity to lift unit. as moving the machine, using shielded cables, using line filters, or shielding the work area. D If using lift forks to move unit, be sure forks are long enough to ex- tend beyond opposite side of unit. OM-217 Page 3
  • 8. 1-4. Principal Safety Standards Safety in Welding and Cutting, ANSI Standard Z49.1, from American Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126 from Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Safety and Health Standards, OSHA 29 CFR 1910, from Superinten- dent of Documents, U.S. Government Printing Office, Washington, D.C. Code for Safety in Welding and Cutting, CSA Standard W117.2, from 20402. Canadian Standards Association, Standards Sales, 178 Rexdale Bou- levard, Rexdale, Ontario, Canada M9W 1R3. Recommended Practices for Plasma Arc Cutting, American Welding Society Standard AWS C5.2, from American Welding Society, 550 N.W. Safe Practices For Occupation And Educational Eye And Face Protec- LeJeune Rd, Miami, FL 33126 tion, ANSI Standard Z87.1, from American National Standards Institute, 1430 Broadway, New York, NY 10018. Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, American Cutting And Welding Processes, NFPA Standard 51B, from National Welding Society Standard AWS F4.1, from American Welding Society, Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 550 N.W. LeJeune Rd, Miami, FL 33126 National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, Batterymarch Park, Quincy, MA 02269. 1-5. EMF Information Considerations About Welding Or Cutting And The Effects Of Low 1. Keep cables close together by twisting or taping them. Frequency Electric And Magnetic Fields Welding or cutting current, as it flows through the welding or cutting 2. Arrange cables to one side and away from the operator. cables, will cause electromagnetic fields. There has been and still is 3. Do not coil or drape cables around your body. some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon 4. Keep cutting power source and cables as far away from operator committee of the National Research Council concluded that: “The body as practical. of evidence, in the committee’s judgment, has not demonstrated that exposure to power-frequency electric and magnetic fields is a human- 5. Connect work clamp to workpiece as close to the cut as possi- health hazard.” However, studies are still going forth and evidence ble. continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic About Pacemakers: fields when welding or cutting. Pacemaker wearers consult your doctor first. If cleared by your doctor, To reduce magnetic fields in the workplace, use the following proce- then following the above procedures is recommended. dures: OM-217 Page 4
  • 9. SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT UTILISATION pom_fre _nd_4/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives. Y Identifie un message de sécurité particulier. Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des ris- ques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVE- . Signifie NOTA ; n’est pas relatif à la sécurité. MENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directi- ves ci-dessous afin de connaître les mesures à prendre pour éviter tout dan- ger. 1-2. Dangers liés au coupage à l’arc au plasma Y Les symboles présentés ci-après sont utilisés tout au long du présent manuel pour attirer votre attention et identifier les ris- UNE DÉCHARGE ÉLECTRIQUE peut ques de danger. Lorsque vous voyez un symbole, soyez entraîner la mort. vigilant et suivez les directives mentionnées afin d’éviter tout Le fait de toucher à une pièce électrique sous tension peut danger. Les consignes de sécurité présentées ci-après ne font donner une décharge fatale ou entraîner des brûlures que résumer l’information contenue dans les normes de sécu- graves. Le chalumeau et le circuit de masse sont rité énumérées à la section 1-5. Veuillez lire et respecter toutes automatiquement actifs lorsque le poste est sous tension. ces normes de sécurité. L’alimentation d’entrée et les circuits internes de l’appareil le sont également. Le coupage au plasma d’arc exige des tensions plus élevées que le soudage Y L’installation, l’utilisation, l’entretien et les réparations ne pour amorcer et maintenir l’arc (souvent de 200 à 400 V CC), c’est pourquoi on doivent être confiés qu’à des personnes qualifiées. fait appel à des chalumeaux conçus avec un système de verrouillage sécuritaire qui met l’appareil hors tension lorsque la capsule anti–feu est Y Au cours de l’utilisation, tenir toute personne à l’écart et plus desserrée ou si le tube touche l’électrode à l’intérieur de la buse. Un poste incorrectement installé ou inadéquatement mis à la terre constitue un danger. particulièrement les enfants. D Ne touchez pas aux pièces électriques sous tension. D Portez des gants isolants et des vêtements de protection secs et sans LE COUPAGE présente un risque de trous. feu ou d’explosion. D Isolez–vous de la pièce à couper et du sol en utilisant des housses ou des tapis assez grands afin d’éviter tout contact physique avec la pièce à cou- Des particules de métal chaud et des étincelles peuvent per ou le sol. jaillir de la pièce au moment du coupage. Les étincelles et le D Ne touchez pas aux pièces du chalumeau si vous êtes en contact avec la métal chaud, la pièce à couper chauffée et l’équipement pièce à couper ou le sol. chaud peuvcnt causer un feu ou des brûlures. Avant de commencer à travailler, assurez–vous que l’endroit est sécuritaire. D Mettez l’appareil hors tension avant d’effectuer la vérification, le nettoyage ou le changement d’une pièce du chalumeau. D Protégez–vous, ainsi que toute autre personne travaillant sur les lieux, D Coupez l’alimentation d’entrée avant d’installer l’appareil ou d’effectuer contre les étincelles et le métal chaud. l’entretien. Verrouillez ou étiquetez la sortie d’alimentation selon la norme D Ne coupez pas dans un endroit où des étincelles pourraient atteindre des OSHA 29 CFR 1910.147 (reportez–vous aux Principales normes de sécu- matières inflammables. rité). D Déplacez toute matière inflammable se trouvant à l’intérieur d’un périmètre D Installez le poste correctement et mettez–le à la terre convenablement se- de 10,7 m (35 pi) de la pièce à couper. Si cela est impossible, vous devez lon les consignes du manuel de l’opérateur et les normes nationales, les couvrir avec des housses approuvées et bien ajustées. provinciales et locales. D Assurez–vous qu’aucune étincelle ni particule de métal ne peut se glisser D Assurez–vous que le fil de terre du cordon d’alimentation est correctement dans de petites fissures ou tomber dans d’autres pièces. relié à la borne de terre dans la boîte de coupure ou que la fiche du cordon D Afin d’éliminer tout risque de feu, soyez vigilant et gardez toujours un extinc- est branchée à une prise correctement mise à la terre – vous devez tou- teur à la portée de la main. jours vérifier la mise à la terre. D Si vous coupez sur un plafond, un plancher ou une cloison, soyez conscient D Avant d’effectuer les connexions d’alimentation, vous devez relier le bon fil que cela peut entraîner un feu de l’autre côté. de terre. D Ne coupez pas sur un contenant fermé tel qu’un réservoir ou un bidon. D Vérifiez fréquemment le cordon d’alimentation afin de vous assurer qu’il D Fixez le câble de masse sur la pièce à couper, le plus près possible de la n’est pas altéré ou à nu, remplacez–le immédiatement s’il l’est. Un fil à nu zone à couper afin de prévenir que le courant de coupage ne prenne une peut entraîner la mort. trajectoire inconnue ou longue et ne cause ainsi une décharge électrique ou D L’équipement doit être hors tension lorsqu’il n’est pas utilisé. un feu. D Vérifiez et remplacez les cosses du câble du chalumeau si elles sont usées D Ne coupez jamais des contenants qui peuvent contenir des matières inflam- ou altérées. mables. Vous devez en premier lieu les vider et les nettoyer D Le câble du chalumeau ne doit pas s’enrouler autour de votre corps. convenablement. D Si les normes le stipulent, la pièce à couper doit être mise à la terre. D Ne coupez pas dans un endroit où l’atmosphère risque de contenir de la D Utilisez uniquement de l’équipement en bonne condition. Réparez ou rem- poussière ou des vapeurs explosives. placez immédiatement toute pièce altérée. D Ne coupez pas de bouteilles, de tuyaux ou de contenants pressurisés. D Portez un harnais de sécurité si vous devez travailler au–dessus du sol. D Ne coupez pas de contenants qui ont déjà reçu des combustibles. D Assurez–vous que tous les panneaux et couvercles sont correctement en D Portez des vêtements de protection exempts d’huile tels que des gants en place. cuir, une veste résistante, des pantalons sans revers, des bottes et un cas- D N’essayez pas d’aller à l’encontre des systèmes de verrrouillage de sécuri- que. té ou de les contourner. D Ne placez pas le poste sur une surface combustible ou au–dessus de celle– D Utilisez uniquement le ou les chalumeaux recommandés dans le manuel ci. de l’opérateur. D Avant le coupage, retirez tout combustible de vos poches, par exemple un briquet au butane ou des allumettes. OM-217 Page 5
  • 10. D N’approchez pas le tube du chalumeau et l’arc pilote lorsque la gâchette est D Ne mettez pas votre tête au–dessus des vapeurs. Ne respirez pas ces va- enfoncée. peurs. D Le câble de masse doit être pincé correctement sur la pièce à couper, métal D Si vous êtes à l’intérieur au moment du coupage, ventilez la pièce ou ayez contre métal (et non de telle sorte qu’il puisse se détacher), ou sur la table recours à une ventilation aspirante installée près de l’arc pour évacuer les de travail le plus près possible de la ligne de coupage. vapeurs et les gaz. D Isoler la pince de masse quand pas mis à la pièce pour éviter le contact D Si la ventilation est médiocre, utilisez un respirateur anti–vapeurs avec tout objet métallique. approuvé. D Veuillez lire le Material Safety Data Sheets (MSDS) et les instructions du Il y a DU COURANT CONTINU IMPORTANT dans fabricant pour obtenir plus de renseignements sur les métaux à couper, les les convertisseurs après la suppression de l’ali- enrobages et les nettoyants. D Travaillez dans un espace restreint uniquement s’il est bien ventilé ou si mentation électrique. vous portez un respirateur anti–vapeurs. Les vapeurs causées par le cou- D Arrêter les convertisseurs, débrancher le courant électrique, et décharger page et l’épuisement de l’oxygène peuvent altérer la qualité de l’air et les condensateurs d’alimentation selon les instructions indiquées dans la entraîner des blessures ou la mort. Assurez–vous que l’air ambiant est sain partie entretien avant de toucher les pièces. pour la santé. D Ne coupez pas dans un endroit près d’opérations de décapage, de net- LES ÉTINCELLES VOLANTES ris- toyage ou de vaporisation. La chaleur et les rayons d’arc peuvent réagir avec les vapeurs et former des gaz hautement toxiques et irritants. quent de provoquer des blessures. D Ne coupez pas des métaux enrobés tels que des métaux galvanisés, Le coupage plasma produit des étincelles et projections de contenant du plomb ou de l’acier plaqué au cadmium, à moins que l’enroba- métal à très haute température. Lorsque la pièce refroidit, ge ne soit ôté de la surface du métal à couper, que l’endroit où vous du laitier peut se former. travaillez ne soit bien ventilé, ou, si nécessaire, que vous ne portiez un res- pirateur anti–vapeurs. Les enrobages ou tous métaux qui contiennent ces D Portez une visière ou des lunettes de sécurité avec des écrans latéraux ap- éléments peuvent créer des vapeurs toxiques s’ils sont coupés. prouvées. D Ne coupez pas de contenants qui renferment ou ont renfermés des matiè- D Portez des vêtements de protection adéquats afin de protéger votre peau. res toxiques ou réactives – vous devez en premier lieu les vider et les D Ayez recours à des protège–tympans ou à un serre–tête ignifuges afin nettoyer convenablement. d’éviter que les étincelles n’entrent dans vos oreilles. LE PLASMA D’ARC peut entraîner LES RAYONS D’ARC peuvent en- des blessures. traîner des brûlures aux yeux et à la peau. La chaleur dégagée par le plasma d’arc peut entraîner de sérieuses brûlures. La force de l’arc est un facteur qui Les rayons d’arc provenant du procédé de coupage s’ajoute au danger de brûlures. La chaleur intense et la produisent des rayons visibles et invisibles intenses puissance de l’arc peuvent rapidement passer au travers (ultraviolets et infrarouges) qui peuvent entraîner des brûlures aux yeux et à la de gants et de tissus. peau. D N’approchez pas le tube du chalumeau. D Lorsque vous coupez ou regardez quelqu’un couper, portez un masque ou D Ne saisissez pas la pièce à couper près de la ligne de coupage. un écran facial avec le filtre approprié. La norme ANSI Z49.1 (reportez– D L’arc pilote peut causer des brûlures – n’approchez pas le tube du chalu- vous aux Principales normes de sécurité) suggère d’utiliser un filtre de meau lorsque vous avez appuyé sur le gâchette. teinte nd 9 (nd 8 étant le minimum) pour tout travail de coupage faisant ap- D Portez des vêtements de protection adéquats qui recouvrent tout votre pel à un courant de moins de 300 A. On mentionne également dans la corps. norme Z49.1 qu’un filtre plus faible peut être utilisé lorsque l’arc est caché par la pièce à couper. Comme cela est habituellement le cas pour les tra- D Ne pointez pas le chalumeau en direction de votre corps ni de la pièce à vaux de coupage à faible courant, les teintes énumérées au tableau 1 sont couper lorsque vous appuyez sur la gâchette – l’arc pilote s’allume automa- fournies à titre d’information pour l’opérateur. tiquement. D Porter des lunettes de sécurité à coques latérales sous votre casque ou D Mettez l’alimentation hors tension et débranchez le cordon d’alimentation écran facial. avant de démonter le chalumeau ou de changer une pièce du chalumeau. D Ayez recours à des écrans protecteurs ou à des rideaux pour protéger les D Utilisez uniquement le ou les chalumeaux recommandés dans le manuel autres contre les rayonnements et les éblouissements; prévenez toute de l’opérateur. personne sur les lieux de ne pas regarder l’arc. D Portez des vêtements confectionnés avec des matières résistantes et igni- LES BOUTEILLES peuvent exploser fuges (cuir et laine) et des bottes de protection. si elles sont endommagées. Tableau 1. Protection des yeux pour le coupage au plasma d’arc Les bouteilles de gaz contiennent du gaz sous haute pression. Si une bouteille est endommagée, elle peut Intensité de courant en ampères Filtre de teinte (minimum) exploser. Puisque les bouteilles de gaz font habituellement partie d’un processus de travail des métaux, assurez–vous Moins de 20 no. 4 de les manipuler correctement. 20 – 40 no. 5 D Protégez les bouteilles de gaz comprimé contre la chaleur excessive, les 40 – 60 no. 6 chocs mécaniques, le laitier, la flamme, les étincelles et l’arc. 60 – 80 no. 8 D Installez et attachez les bouteilles dans la position verticale à l’aide d’une chaîne, sur un support stationnaire ou un châssis porte–bouteille afin de prévenir qu’elles ne tombent ou ne basculent. LE BRUIT peut endommager l’ouïe. D Les bouteilles ne doivent pas être près de la zone de coupage ni de tout autre circuit électrique. Certaines applications de coupage produisent un bruit D Un contact électrique ne doit jamais se produire entre un chalumeau de constant, ce qui peut endommager l’ouïe si le niveau plasma d’arc et une bouteille. sonore dépasse les limites permises par l’OSHA (repor- D Ne coupez jamais sur une bouteille pressurisée – une explosion en tez–vous aux Principales normes de sécurité). résulterait. D Utilisez des protège–tympans ou un serre–tête antibruit si le niveau sonore D Utilisez uniquement des bouteilles de gaz, des détendeurs, des boyaux et est élevé. des raccords conçus pour l’application déterminée. Gardez–les, ainsi que D Prévenez toute personne sur les lieux du danger relié au bruit. toute autre pièce associée, en bonne condition. D Détournez votre visage du détendeur–régulateur lorsque vous ouvrez la LES FUMÉES ET LES GAZ peuvent soupape de la bouteille. D Le couvercle du détendeur doit toujours être en place, sauf lorsque vous être dangereux. utilisez la bouteille ou qu’elle est reliée pour usage ultérieur. Le coupage produit des vapeurs et des gaz. Respirer D Lisez et suivez les instructions sur les bouteilles de gaz comprimé, l’équi- ces vapeurs et ces gaz peut être dangereux pour la pement connexe et le dépliant P–1 de la CGA mentionné dans les santé. Principales normes de sécurité. OM-217 Page 6
  • 11. 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance DES PIECES CHAUDES peuvent pro- Risque D’INCENDIE OU voquer des brûlures graves. D’EXPLOSION. D Ne pas toucher des parties chaudes à mains nues. D Ne pas placer l’appareil sur, au-dessus ou à proximité D Laisser refroidir avant d’intervenir sur la torche. de surfaces infllammables. D Ne pas installer l’appareil à proximité de produits in- flammables DES ORGANES MOBILES peuvent D Ne pas surcharger l’installation électrique – s’assurer que l’alimentation est provoquer des blessures. correctement dimensionné et protégé avant de mettre l’appareil en service. D S’abstenir de toucher des organes mobiles tels que LES CHARGES ÉLECTROSTATI- des ventilateurs. QUES peuvent endommager les cir- D Maintenir fermés et verrouillés les portes, panneaux, recouvrements et dispositifs de protection. cuits imprimés. D Etablir la connexion avec la barrette de terre avant de DES PARTICULES VOLANTES manipuler des cartes ou des pièces. peuvent blesser les yeux. D Utiliser des pochettes et des boîtes antistatiques pour stocker, déplacer ou expédier des cartes PC. D Porter des lunettes de sécurité avec protections laté- rales ou frontales. LE RAYONNEMENT HAUTE FRÉ- QUENCE (H.F.) risque de provoquer LES CHAMPS MAGNÉTIQUES peuv- des interférences. ent affecter les stimulateurs cardia- ques. D Le Rayonnement haute frequence (H.F.) peut provo- quer des interférences avec les équipements de ra- D Porteurs de stimulateur cardiaque, restez à distance. dio–navigation et de communication, les services de sécurité et les ordinateurs. D Les porteurs sont priés de consulter leur médecin avant d’approcher les opérations de coupage D Demander seulement à des personnes qualifiées familiarisées avec des plasma. équipements électroniques de faire fonctionner l’installation. D L’utilisateur est tenu de faire corriger rapidement par un électricien qualifié les interférences résultant de l’installation. L’EMPLOI EXCESSIF peut D Si le FCC signale des interférences, arrêter immédiatement l’appareil. SURCHAUFFER L’ÉQUIPEMENT. D Effectuer régulièrement le contrôle et l’entretien de l’installation. D Maintenir soigneusement fermés les portes et les panneaux des sources D Prévoir une période de refroidissement; respecter le de haute fréquence, maintenir les éclateurs à une distance correcte et utili- cycle opératoire nominal. ser une terre et et un blindage pour réduire les interférences éventuelles. D Réduire l’ampérage (épaisseur) avant de continuer à couper ou réduire le facteur de marche. LE COUPAGE Ã L’ARC peut causer des interférence. Danger D’EXPLOSION D’HY- DROGÈNE. D L’énergie électromagnétique peut gêner le fonction- nement d’appareils électroniques comme des ordi- nateurs et des robots. D Lors du coupage d’aluminium partiellement ou totale- ment immergé dans l’eau, de l’hydrogène libre peut D Pour réduire la possibilité d’interférence, maintenir les câbles aussi courts s’accumuler sous la pièce. que possible, les grouper, et les poser aussi bas que possible (ex. par D Consultez votre ingénieur de coupage et les instruc- terre). tions de la table de coupage. D Veiller à couper à une distance de 100 mètres de tout équipement électroni- que sensible. D S’assurer que la source de coupage est correctement branchée et mise à LA CHUTE DE L’APPAREIL peut la terre. blesser. D Si l’interférence persiste, l’utilisateur doit prendre des mesures supplémen- taires comme écarter la machine, utiliser des câbles blindés de des filtres, D Utiliser l’anneau de levage uniquement pour soulever ou boucler la zone de travail. l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire. D Utiliser un engin d’une capacité appropriée pour sou- lever l’appareil. D En utilisant des fourches de levage pour déplacer l’unité, s’assurer que les fourches sont suffisamment longues pour dépasser du côté opposé de l’appareil. 1-4. Principales normes de sécurité Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel- Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, ding Society, 550 N.W. Lejeune Rd, Miami FL 33126 de la Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. Règles de sécurité en soudage, coupage et procédés connexes, norme 20402. CSA W117.2, de l’Association canadienne de normalisation, vente de normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3. Recommended Safe Practice for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, norme AWS Safe Practices For Occupation And Educational Eye And Face Protec- F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL tion, norme ANSI Z87.1, de l’American National Standards Institute, 33126 1430 Broadway, New York, NY 10018. National Electrical Code, NFPA Standard 70, de la National Fire Protec- Cutting and Welding Processes, norme NFPA 51B, de la National Fire tion Association, Batterymarch Park, Quincy, MA 02269. Protection Association, Batterymarch Park, Quincy, MA 02269. OM-217 Page 7
  • 12. 1-5. Information sur les champs électromagnétiques Données sur le soudage électrique et sur les effets, pour l’organisme, Afin de réduire les champs électromagnétiques dans l’environnement des champs magnétiques basse fréquence de travail, respecter les consignes suivantes : L’extrait suivant est tiré des conclusions générales du document intitulé 1 Garder les câbles ensembles en les torsadant ou en les Biological Effects of Power Frequency Electric & Magnetic Fields – attachant avec du ruban adhésif. Background Paper, OTA–BP–E–53 (Washington DC : U.S. Govern- 2 Mettre tous les câbles du côté opposé de l’opérateur. ment Printing Office, mai 1989), publié par le Office of Technology Assessment du Congrès américain : «... il existe maintenant d’abon- 3 Ne pas courber pas et ne pas entourer pas les câbles autour de dantes données scientifiques compilées à la suite d’expériences sur la vous. cellule ou d’études sur des animaux et des humains, qui montrent clai- 4 Garder le poste de soudage et les câbles le plus loin possible de rement que les champs électromagnétiques basse fréquence peuvent vous. avoir des effets sur l’organisme et même y produire des transforma- 5 Relier la pince de masse le plus près possible de la zone de tions. Même s’il s’agit de travaux de très grande qualité, les résultats soudure. sont complexes. Cette démarche scientifique ne nous permet pas d’établir un tableau d’ensemble cohérent. Pire encore, elle ne nous per- Consignes relatives aux stimulateurs cardiaques : met pas de tirer des conclusions finales concernant les risques Les consignes mentionnées précédemment font partie de celles desti- éventuels, ni d’offrir des conseils sur les mesures à prendre pour rédui- nées aux personnes ayant recours à un stimulateur cardiaque. Veuillez re sinon éliminer les risques éventuels». (Traduction libre) consulter votre médecin pour obtenir plus de détails. OM-217 Page 8
  • 13. SECTION 2 – DEFINITIONS 2-1. Warning Label Definitions Warning! Watch Out! There are possible hazards as shown by the symbols. 1 Cutting sparks can cause explosion or fire. 1.1 Keep flammables away from cutting. Do not cut near flammables. 1.2 Cutting sparks can cause fires. Have a fire extinguisher 1 1.1 1.2 1.3 nearby, and have a watchperson ready to use it. 1.3 Do not cut on drums or any closed containers. 2 The plasma arc can cause injury and burns. 2.1 Turn off power before 2 disassembling torch. 2.1 2.2 2.3 2.2 Do not grip material near cutting path. 2.3 Wear complete body protection. 3 Electric shock from torch or wiring can kill. 3.1 Wear dry insulating gloves. 3 3.1 3.2 3.3 Do not wear wet or damaged gloves. 3.2 Protect yourself from electric shock by insulating yourself from work and ground. 3.3 Disconnect input plug or power before working on 4 4.1 4.2 4.3 machine. 4 Breathing cutting fumes can be hazardous to your health. 4.1 Keep your head out of the fumes. 4.2 Use forced ventilation or local exhaust to remove the fumes. 5 5.1 4.3 Use ventilating fan to remove fumes. 5 Arc rays can burn eyes and + + + 5.1 injure skin. Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of 6 7 filter. Wear complete body protection. + 6 Become trained and read the instructions before working on the machine or cutting. 7 Do not remove or paint over (cover) the label. S-179 219 1/96 OM-217 Page 9
  • 14. Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring can kill. Disconnect input plug or power before working on machine. Read the Owner’s Manual before working on this machine. 1 Consult rating label for input power requirements, and check power available at the job site – they must match. 2 Read Owner’s Manual and inside labels for connection points and procedures. 3 Move jumper links as shown on inside label to match ? V voltage at job site. 1 2 3 4 Having a loop of extra length, connect grounding conductor first. ? V 5 Connect line input conductors as shown on inside label – ? A 5 double-check all connections, jumper link positions, and ÍÍÍ input voltage before applying ÍÍÍ ÍÍÍ ÍÍÍ ÍÍÍ 3 power. 4 S-179 290 1/96 1 Input connection point for nitrogen gas. 2 3 2 Input connection point for compressed air. 3 Air/gas pressure adjustment control with recommended setting. – + N 70 psi ( 4.8 bar 483 kPa ) S-175 971 1 1/96 OM-217 Page 10
  • 15. 2-2. Manufacturer’s Rating Label For CE Products Match label to one on unit. See Section 3-4. 100 Ampere Model 70 Ampere Model 3 3 EN 60974-1 EN 60974-1 30A/120V 100A/120V 30A/120V 70A/120V X 80% 100% X 100% I2 100A 80A I2 70A U0 = 270V U0 = 270V U2 120V 120V U2 120V U1 V I1 U1 V I1 3 220V 78A 64A 3 220V 57A 380V 45A 37A 380V 33A 415V 41A 34A 415V 30A 50 Hz 50 Hz IP 21S IP 21S Drawing # S-174 462-A S-174 463-A OM-217 Page 11
  • 16. 2-3. Symbols And Definitions NOTE Some symbols are found only on CE products. A Amperes Plasma Arc Cutting (PAC) Trigger Hold On Trigger Hold Off V Volts Pilot/Pulse Starting Continuous Pilot Arc Pulse No – Do Not Do Output Increase Temperature This Protective Earth Three Phase High Frequency Input (Ground) On Off Percent Direct Current U0 Rated No Load Voltage (Average) U1 Primary Voltage U2 Conventional Load Voltage Line Connection Three Phase I1 Primary Current I2 Rated Welding Current X Duty Cycle Transformer Rectifier IP Degree Of Protection Loose Shield Cup Torch-Tip-To Electrode Short Hz Hertz Air/Gas Pressure Low Air Pressure Nitrogen Gas Input Work Adjustment Light Connection Adjust Air/Gas Pressure SECTION 3 – INSTALLATION 3-1. Specifications Amperes Input at Rated Output, Plasma Model/ 50 or 60 Hz, Three-Phase Gas Rated Plasma Flow/ Max IP Output 200 V 220 V 230 V 380 V 415 V 460 V 575 V KVA KW Gas Pressure OCV Rating 1000 / 70 Amperes At 57 54 33 30 27 22 21 10 108 Volts DC –– (4.0*) (2.6*) (2.5*) (1.5*) (1.3*) (1.0*) (1.04*) (0.6*) At 100% 7 CFM Duty Cycle Air Or 270 (198 L/min) Nitrogen Volts 21S 1250 / 100 At 70 PSI Only DC Amperes At (482 kPa) 85 77 74 45 41 37 30 30 16 120 Volts DC (3.4*) (4.0*) (2.9*) (2.5*) (1.5*) (1.5*) (1.0*) (1.2*) (0.5*) At 80% Duty Cycle *While idling OM-217 Page 12
  • 17. 3-2. Duty Cycle And Overheating Duty Cycle is percentage of 10 min- 70 Ampere Models: 100% Duty Cycle At 70 Amperes utes that unit can cut at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, Temperature trouble light goes On, and cooling fan runs. Wait fifteen minutes for unit to cool or temperature light to go off. Reduce amperage or duty Continuous Welding cycle before cutting or gouging. Y Exceeding duty cycle can 100 Ampere Models: 80% Duty Cycle At 100 Amperes damage unit and void warranty. 8 Minutes Welding 2 Minutes Resting Overheating A 0 15 OR Minutes Reduce Duty Cycle duty1 4/95 – Ref. ST-159 463-B 3-3. Cutting Speed The cutting speed curves show the recommended maximum cutting speed capabilities of the power source and torch for mild steel of various thickness. Cut at speeds below the lines shown to avoid poor cuts and torch wear. 70 Ampere Model 100 Ampere Model ST-171 819 / ST-171 820 OM-217 Page 13
  • 18. 3-4. Selecting A Location 1 Lift Hook Install lift hooks using supplied bolts. Tighten to 25 ft/lb (34 N·m). Movement 2 Spreader Bar (Not Supplied) 3 Lifting Cable (Not Supplied) If lifting unit, use spreader and 3 cable. 2 4 Lifting Eye 5 Lifting Forks If using lifting forks, extend forks 1 beyond opposite side of unit. 4 6 Rating Label (Non CE Models Only) 7 Rating Label (CE Models Only, See Section 2-2) Use rating label to determine input OR power needs. 5 8 Plate Label (CE Models Only) 9 Line Disconnect Device Locate unit near correct input pow- er supply. Location And Airflow Y Special installation may be required where gasoline or 6 9 volatile liquids are present – see NEC Article 511 or CEC Section 20. 8 7 18 in (460 mm) 18 in (460 mm) S-0439 / Ref. ST-800 402-B / ST-159 463-B OM-217 Page 14
  • 19. 3-5. Dimensions And Weight Dimensions Height 37-1/4 in (946 mm) A Width 22-3/4 in (578 mm) B Length 20 in (508 mm) C A 22-1/16 in (560 mm) B 21-1/32 in (210 mm) D C 1-1/32 in (26 mm) E D 18-13/16 in (478 mm) E 17-11/16 (449 mm) F 5-5/8 (143 mm) F G 1-1/8 (29 mm) Bottom Front H H 7/16 in (11 mm) Dia G ST-159 464-B Weight 405 lbs (184 kg) 3-6. Tipping Y Be careful when placing or moving unit over uneven surfaces. OM-217 Page 15