Branche warning 3 broches 2cv mehari club cassisMarques Laurent
This document provides technical specifications for connecting a 3-prong plug to vehicles including the 2CV, MEHARI, CLUB, and CASSIS models. It was created by Laurent in October 2010 and contains information on plugs, wiring diagrams, and other technical details.
Branche warning 3 broches 2cv mehari club cassisMarques Laurent
This document provides technical specifications for connecting a 3-prong plug to vehicles including the 2CV, MEHARI, CLUB, and CASSIS models. It was created by Laurent in October 2010 and contains information on plugs, wiring diagrams, and other technical details.
Este documento fornece instruções para instalação, programação e operação do inversor de frequência Altivar 312 para motores assíncronos. Ele contém informações sobre montagem, fiação, configuração de parâmetros, funções e solução de problemas.
The document provides removal instructions for various component parts of an automatic transmission. It begins by describing how to remove external parts like the torque converter, neutral start switch, and oil pan. It then details removing internal components such as the valve body, accumulators, brake pistons, planetary gears, and differential gear assembly. Precautions are provided to safely remove parts and avoid damage.
This document contains diagrams and specifications for a PLC control panel for a tobacco filling station. It includes diagrams of the main incoming power, power monitoring circuits, and safety circuits of the control panel. Component details are provided, such as the makes and models of circuit breakers, contactors, sensors and other devices. Dimensions and layout of the overall control panel and internal components are shown. Pneumatic and electrical control circuits are illustrated.
Manual do inversor de frequência danfossClaudio Arkan
Este documento fornece instruções de segurança e instalação para o VLT Micro Drive. Ele alerta sobre os perigos da alta tensão e fornece diretrizes para evitar choques elétricos e partidas acidentais. Também inclui especificações técnicas, como dimensões mecânicas, capacidade de corrente e aterramento.
O documento discute os conceitos e práticas de manutenção de equipamentos elétricos, incluindo tipos de manutenção, priorização de acordo com o processo de fabricação, uso de equipamentos reservas, identificação, efeito da carga, e segurança. É focado em garantir a confiabilidade dos equipamentos elétricos e a continuidade dos processos industriais.
Guia definitivo dimensionamento de cabos elétricos - eng. anderson OctavioCicone
This document provides a 3-step guide for sizing electrical cables according to the Brazilian standard NBR 5410. It begins by emphasizing the importance and responsibility of properly sizing cables to ensure safety and prevent issues like fires or equipment damage. The guide then covers the three criteria for cable sizing - minimum cross-sectional area, current carrying capacity, and voltage drop. Tables from NBR 5410 are referenced to help select the appropriate cable size based on factors like cable installation method and current load. The document stresses that cable sizing should always be done carefully according to technical standards to avoid safety risks from improperly sized wiring.
This document discusses various busbar arrangements used in substations including:
- Single busbar system
- Single bus with sectionaliser system
- Double busbar system
- One and half breaker system
It provides diagrams and explanations of how each system works, their advantages and disadvantages. It also discusses the different busbar configurations adopted by the Andhra Pradesh Transmission Corporation (APTRANSCO) at various voltage levels.
This document shows a variables list for DNP3 on a Hydran M2 & M2-X device. It includes 96 registers with descriptions of analog inputs like tank levels and temperatures, as well as operation details like tap position and counts. The ranges, units, and data formats are defined for monitoring and recording purposes.
This document provides pricing information for Siemens LV Switchgear motor control products, including contactor relays, power contactors, overload relays, circuit breakers and other devices. It lists product codes, descriptions, unit prices and standard packaging quantities for various sizes and configurations. Key products mentioned include contactor relays, power contactors, overload relays, motor protection circuit breakers and soft starters. The price list is effective from October 1st, 2014.
O documento apresenta um sumário sobre o sistema de injeção eletrônica, direção elétrica e rede CAN do veículo Stilo da Fiat. O texto descreve os principais componentes dos sistemas, como o ECU, reles, sensores e atuadores, e fornece esquemas elétricos para auxiliar na compreensão do funcionamento.
A TC Chicotes tem como objetivo fornecer produtos de qualidade para atender o mercado automotivo e apresenta seu catálogo 2011/2012 com novos lançamentos e a linha mais completa de chicotes, conectores e terminais. Os clientes podem acompanhar novidades no site da empresa.
Este documento fornece instruções para instalação, programação e operação do inversor de frequência Altivar 312 para motores assíncronos. Ele contém informações sobre montagem, fiação, configuração de parâmetros, funções e solução de problemas.
The document provides removal instructions for various component parts of an automatic transmission. It begins by describing how to remove external parts like the torque converter, neutral start switch, and oil pan. It then details removing internal components such as the valve body, accumulators, brake pistons, planetary gears, and differential gear assembly. Precautions are provided to safely remove parts and avoid damage.
This document contains diagrams and specifications for a PLC control panel for a tobacco filling station. It includes diagrams of the main incoming power, power monitoring circuits, and safety circuits of the control panel. Component details are provided, such as the makes and models of circuit breakers, contactors, sensors and other devices. Dimensions and layout of the overall control panel and internal components are shown. Pneumatic and electrical control circuits are illustrated.
Manual do inversor de frequência danfossClaudio Arkan
Este documento fornece instruções de segurança e instalação para o VLT Micro Drive. Ele alerta sobre os perigos da alta tensão e fornece diretrizes para evitar choques elétricos e partidas acidentais. Também inclui especificações técnicas, como dimensões mecânicas, capacidade de corrente e aterramento.
O documento discute os conceitos e práticas de manutenção de equipamentos elétricos, incluindo tipos de manutenção, priorização de acordo com o processo de fabricação, uso de equipamentos reservas, identificação, efeito da carga, e segurança. É focado em garantir a confiabilidade dos equipamentos elétricos e a continuidade dos processos industriais.
Guia definitivo dimensionamento de cabos elétricos - eng. anderson OctavioCicone
This document provides a 3-step guide for sizing electrical cables according to the Brazilian standard NBR 5410. It begins by emphasizing the importance and responsibility of properly sizing cables to ensure safety and prevent issues like fires or equipment damage. The guide then covers the three criteria for cable sizing - minimum cross-sectional area, current carrying capacity, and voltage drop. Tables from NBR 5410 are referenced to help select the appropriate cable size based on factors like cable installation method and current load. The document stresses that cable sizing should always be done carefully according to technical standards to avoid safety risks from improperly sized wiring.
This document discusses various busbar arrangements used in substations including:
- Single busbar system
- Single bus with sectionaliser system
- Double busbar system
- One and half breaker system
It provides diagrams and explanations of how each system works, their advantages and disadvantages. It also discusses the different busbar configurations adopted by the Andhra Pradesh Transmission Corporation (APTRANSCO) at various voltage levels.
This document shows a variables list for DNP3 on a Hydran M2 & M2-X device. It includes 96 registers with descriptions of analog inputs like tank levels and temperatures, as well as operation details like tap position and counts. The ranges, units, and data formats are defined for monitoring and recording purposes.
This document provides pricing information for Siemens LV Switchgear motor control products, including contactor relays, power contactors, overload relays, circuit breakers and other devices. It lists product codes, descriptions, unit prices and standard packaging quantities for various sizes and configurations. Key products mentioned include contactor relays, power contactors, overload relays, motor protection circuit breakers and soft starters. The price list is effective from October 1st, 2014.
O documento apresenta um sumário sobre o sistema de injeção eletrônica, direção elétrica e rede CAN do veículo Stilo da Fiat. O texto descreve os principais componentes dos sistemas, como o ECU, reles, sensores e atuadores, e fornece esquemas elétricos para auxiliar na compreensão do funcionamento.
A TC Chicotes tem como objetivo fornecer produtos de qualidade para atender o mercado automotivo e apresenta seu catálogo 2011/2012 com novos lançamentos e a linha mais completa de chicotes, conectores e terminais. Os clientes podem acompanhar novidades no site da empresa.
This document provides technical specifications for a 2CV MEHARI CLUB CASSIS vehicle, including its dimensions: length of 1260 mm, width of 680 mm, height of 580 mm, and wheelbase of 1110 mm. It also mentions the vehicle has a 2-place rear bench seat.
1. Branchement pour faisceau Electrique 2CV
avec boîte à fusibles
rèf. : 3120000
Fiche technique 2CV MEHARI CLUB CASSIS
Schema de cablage du bouton Warning ancien modèle
Schema de cablage du moteur essuie glace
Câblage 1
Câblage 2
réf. : 1101200
7
01
0
11
11
0
01
9
9
6
5
1
2
3
4
- Deux cas possibles de branchement en fonction du bouton poussoir (il en existe plusieurs
modèles).
Comment faire son choix de câblage ?
- Si le moteur ne fait pas un arrêt automatique à la position de repos, il vous suffit de passer à
l’autre câblage.
Masse
Fil Gris
Masse
Fil Gris
Bouton pressoir
Fil Noir
Bouton pressoir
Fil Noir
Bouton pressoir
Fil Bleu
Bouton pressoir
Fil Bleu
+ 12volts
Fil Blanc
+ 12volts