This document summarizes the manufacturing process and maintenance of power transformers. It describes the key components of a transformer like the core, windings, bushings, oil filling, and conservator. The manufacturing process involves preparing the raw materials, winding the coils, assembling the core and coils, connecting accessories, drying, oil filtration and filling. Regular maintenance is needed to monitor the transformer hourly, daily, weekly, monthly, yearly and every 2-5 years to ensure proper functioning. Transformers are important equipment that allow transmitted power to be stepped up or down to usable voltages without changing frequency.
Este documento describe las fuentes controladas o dependientes, que son elementos activos cuyo voltaje o corriente depende de otra variable en la red, como voltaje o corriente. Explica que existen fuentes controladas de voltaje y de corriente, y que en cada caso la magnitud de la fuente (voltaje o corriente) es proporcional a la variable de control. También incluye un ejemplo de cálculo de potencia en un circuito que contiene una fuente dependiente.
This document outlines the design of 500kV AC and 400kV DC transmission lines for transmitting 2GW of power over 700km. Key aspects of the AC line design include using 3 transmission lines with a capacity of 700MW each. The DC line design uses converting stations at each end with thyristor valves and filters to convert to 400kV DC for transmission. An economic comparison estimates the AC line would cost $98.6 million while the DC line would cost $91 million, with the break-even distance determining which is more cost effective based on the length of the transmission line.
The document discusses moulded case circuit breakers in the TOS2 series. It provides specifications for various models of the TOS2 breaker, including rated currents from 12.5A to 1600A, rated voltages up to 750V, and rated short circuit and service short circuit breaking capacities. It describes the use of TOS2 breakers for distributing electric energy and protecting circuit equipment from overloads and short circuits. It also mentions electronic and motor protection releases available for some TOS2 models.
WHAT IS TRANSFORMER, DEFINE TRANSFORMER, TYPES OF TRANSFORMER, RATINGS OF TRANSFORMERS, MANUFACTURING PROCESS OF TRANSFORMER, PARTS OF TRANSFORMER, TESTS OF TRANSFORMER, COSTING OF COPPER.
High voltage technology & insulation testingZeeshan Akhtar
About HV Transmission, distribution, Voltage level classification, Insulation testing.
Part 1
What is High Voltage?
Why Needed
Levels of Voltages
Application of High Voltage
Electrical Insulation and Dielectrics
Part 2
Design & Test Issues for High Voltage
Aircraft Electric Power System
Introduction to the importance of HV in electric actuator systems
Basic review of HV design
Discussion of test methods
Summary
Part 3
Voltage Testing & Partial Discharge Measurement For Power Cable Accessories
Introduction
Ac Test After Installation
Acrf Test System
Schematic Diagram Of Test System
Arallel Operation Mode Of Test System
Artial Discharge Methods & Principle.
Iscussion & Conclusion.
The document summarizes key concepts related to electrical power systems. It discusses resistance in conductors, which depends on material, length, cross-sectional area, and temperature. It also describes bundled conductors, which are made of multiple subconductors joined together to increase current capacity. Skin effect and proximity effect are explained, where skin effect causes current to flow at the surface of conductors especially at high frequencies, and proximity effect increases resistance due to interaction between magnetic fields of nearby conductors.
This document summarizes the manufacturing process and maintenance of power transformers. It describes the key components of a transformer like the core, windings, bushings, oil filling, and conservator. The manufacturing process involves preparing the raw materials, winding the coils, assembling the core and coils, connecting accessories, drying, oil filtration and filling. Regular maintenance is needed to monitor the transformer hourly, daily, weekly, monthly, yearly and every 2-5 years to ensure proper functioning. Transformers are important equipment that allow transmitted power to be stepped up or down to usable voltages without changing frequency.
Este documento describe las fuentes controladas o dependientes, que son elementos activos cuyo voltaje o corriente depende de otra variable en la red, como voltaje o corriente. Explica que existen fuentes controladas de voltaje y de corriente, y que en cada caso la magnitud de la fuente (voltaje o corriente) es proporcional a la variable de control. También incluye un ejemplo de cálculo de potencia en un circuito que contiene una fuente dependiente.
This document outlines the design of 500kV AC and 400kV DC transmission lines for transmitting 2GW of power over 700km. Key aspects of the AC line design include using 3 transmission lines with a capacity of 700MW each. The DC line design uses converting stations at each end with thyristor valves and filters to convert to 400kV DC for transmission. An economic comparison estimates the AC line would cost $98.6 million while the DC line would cost $91 million, with the break-even distance determining which is more cost effective based on the length of the transmission line.
The document discusses moulded case circuit breakers in the TOS2 series. It provides specifications for various models of the TOS2 breaker, including rated currents from 12.5A to 1600A, rated voltages up to 750V, and rated short circuit and service short circuit breaking capacities. It describes the use of TOS2 breakers for distributing electric energy and protecting circuit equipment from overloads and short circuits. It also mentions electronic and motor protection releases available for some TOS2 models.
WHAT IS TRANSFORMER, DEFINE TRANSFORMER, TYPES OF TRANSFORMER, RATINGS OF TRANSFORMERS, MANUFACTURING PROCESS OF TRANSFORMER, PARTS OF TRANSFORMER, TESTS OF TRANSFORMER, COSTING OF COPPER.
High voltage technology & insulation testingZeeshan Akhtar
About HV Transmission, distribution, Voltage level classification, Insulation testing.
Part 1
What is High Voltage?
Why Needed
Levels of Voltages
Application of High Voltage
Electrical Insulation and Dielectrics
Part 2
Design & Test Issues for High Voltage
Aircraft Electric Power System
Introduction to the importance of HV in electric actuator systems
Basic review of HV design
Discussion of test methods
Summary
Part 3
Voltage Testing & Partial Discharge Measurement For Power Cable Accessories
Introduction
Ac Test After Installation
Acrf Test System
Schematic Diagram Of Test System
Arallel Operation Mode Of Test System
Artial Discharge Methods & Principle.
Iscussion & Conclusion.
The document summarizes key concepts related to electrical power systems. It discusses resistance in conductors, which depends on material, length, cross-sectional area, and temperature. It also describes bundled conductors, which are made of multiple subconductors joined together to increase current capacity. Skin effect and proximity effect are explained, where skin effect causes current to flow at the surface of conductors especially at high frequencies, and proximity effect increases resistance due to interaction between magnetic fields of nearby conductors.
Module 2 ee369 KTU syllabus-high voltage ac generation,resonant circuitsAsha Anu Kurian
Generation of high AC voltages-Testing transformer – single unit testing transformer, cascaded transformer – equivalent circuit of cascaded transformer – generation of high frequency AC voltages- series resonance circuit – resonant transformer – voltage regulation.
This document discusses testing of transformers. It provides an overview of transformers and their functions in transmission and distribution of electrical energy. It then describes various routine, type, and special tests performed on transformers, including winding resistance measurement, voltage ratio measurement, no-load loss measurement, load loss measurement, insulation resistance measurement, and dielectric tests. It also discusses short-circuit testing procedures and criteria. Temperature rise testing and its limits are also summarized.
Electrical energy is generated at power stations and transmitted through a network with two parts: transmission and distribution. The transmission system uses high voltage power lines supported by steel transmission towers ranging from 15-55 meters tall. There are different types of poles that can support power lines for the distribution system, including wooden poles, concrete poles, steel tubular poles, and steel towers, with factors like cost, strength, and maintenance considered for the appropriate selection. Safety protocols must be followed when working with transmission towers.
This document discusses underground cables for electrical power distribution. It covers the construction of cables including conductors, insulation, metallic sheathing, bedding, armouring and serving. Common insulating materials like XLPE are described. Cables are classified based on voltage level. Methods of laying cables underground include direct laying, draw-in systems and solid systems. Potential cable faults include open circuits, short circuits and earth faults. Underground cables have advantages over overhead systems like better appearance, lower maintenance needs and fewer faults, but the installation costs are higher.
OPEN CIRCUIT AND SHORT CIRCUIT TEST OF SINGLE PHASE TRANSFORMER|DAY7| BASIC E...Prasant Kumar
#Open_circuit_short_circuit_test of single phase transformer
#OC_SC_TEST OF TRANSFORMER
#Core loss and copper loss test of single phase transformer.
After going through this session you will be able to answer the following questions.
• Which parameters are obtained from O.C test?
• Which parameters are obtained from S.C test?
• What percentage of rated voltage is needed to be applied to carry out O.C test?
• What percentage of rated voltage is needed to be applied to carry out S.C test?
• From which side of a large transformer, would you like to carry out O.C test?
• From which side of a large transformer, would you like to carry out S.C test?
Aim of conduction transformer Open Circuit & Short Circuit test
To predict its performance without actual loading.
Determination of equivalent circuit parameters
To determine parameters of a transformer like voltage regulation and efficiency
Open circuit test is carried out to determine core loss and shunt parameters.
Open circuit test is carried out at rated voltage and rated frequency . During this test, rated flux is produced in the core .
To carry out open circuit test rated voltage at rated frequency is applied to LV side of the transformer and HV side is left opened as shown in the circuit diagram.
HV side is left opened because it is easier to arrange rated voltage supply on LV side because no load current which is quite small about 2 to 5% of the rated current.
Metering instrument connected at LV side are economical & always safer to work.
The voltmeter, ammeter and the wattmeter readings are taken and suppose they are Voc , Io and Poc respectively.
Strictly speaking the wattmeter will record the core loss as well as the LV winding copper loss. But the winding copper loss is very small compared to the core loss as the flux in the core is rated.
1. Transformers have on-load and off-load tap changers that allow adjusting the transformer's output voltage without interrupting the load current. On-load tap changers can adjust voltage while energized using fast-acting switches, while off-load tap changers require de-energizing the transformer to change taps.
2. On-load tap changers are commonly used in power generation and distribution transformers to control voltage as load and line conditions vary. They monitor voltage and raise or lower taps using an automatic voltage regulator. Off-load tap changers are typically used in solar and wind projects where the generator voltage is low-voltage.
3. The on-load tap changer maintains uninterrupted
Reluctance is the opposition to magnetic flux in a magnetic circuit, analogous to resistance in an electric circuit. Reluctance is caused by properties of the magnetic material like length, cross-sectional area, and permeability. The reluctance of a non-uniform magnetic circuit is calculated by adding the reluctances of each uniform section. An air gap is often included to reduce saturation by increasing reluctance.
Inductance is the ability of a circuit to store energy in a magnetic field. It is caused by the self-inductance within a coil or mutual inductance between two linked coils. Inductors use this property to oppose changes in current flow. The standard unit for inductance is the henry.
HVDC systems remain the best option for long-distance bulk power transmission and connecting asynchronous grids. They allow for more economical and environmentally friendly power transmission compared to HVAC systems in these conventional applications. However, advances in technology, deregulation of electricity markets, and environmental protection efforts are increasing the viability of HVDC systems for additional situations where high voltage AC transmission was previously preferred.
This document provides information about transformers and their components. It discusses how transformers work using electromagnetic induction to transfer energy between circuits without a direct electrical connection. The key components of a transformer are described, including the magnetic core made of silicon steel, the windings, insulation and cooling using mineral oil. Ideal transformer theory is also covered, explaining voltage and current ratios based on winding turns.
The document discusses lightning protection for wind turbine blades. It defines a wind turbine as a device that converts wind's kinetic energy to electrical power. There are two main types: horizontal axis and vertical axis turbines. Lightning is a sudden electrostatic discharge during a storm that can generate direct thermal effects at the strike point. The blades are one of the most vulnerable parts and research has analyzed the damage mechanisms from lightning strikes. Installation of lightning arresters at blade tips can effectively intercept lightning strikes.
Case Study - Importance of Relay Coordination in Process IndustriesSystem Protection
A cement plant experienced unexpected tripping of the entire plant twice in three months due to poor relay coordination. An investigation found that load had been added to a motor control center without properly adjusting the relay settings. Specifically, a 75kW high pressure pump and compressor loads totaling 217kW were added. This caused the starting current of a 315kW crusher motor to exceed threshold levels after it restarted, tripping the entire plant. The outages cost the plant over 500 tons of lost cement production and 2.5-2.8 million rupees in losses each time. The case study highlights the importance of coordinating relay and protection settings whenever modifications are made to the electrical distribution system.
Main component parts of the overhead line
The most effective method of providing protection to transmission lines against direct lightning strokes is by use of overhead ground wires as shown in Fig 6. For simplicity, one ground wire and one line conductor are shown. The ground wires are placed above the line conductors at such positions that practically all lightning strokes are intercepted by them (i.
e. ground wires). The ground wires are grounded at each tower or pole through a low resistance as possible. Due to their proper location, the ground wires will take up all the lightning strokes instead of allowing them to line conductors. The degree of protection provided by the ground wires depends upon the footing resistance of the tower.
This power point presentation provides an overview of fault analysis and sequence networks in power systems. It defines different types of faults including open circuit faults, short circuit faults, symmetrical faults, and unsymmetrical faults. Symmetrical faults involve all three phases and remain balanced, while unsymmetrical faults involve one or two phases. Sequence networks, including positive, negative, and zero sequence networks are used for fault analysis. The presentation describes each type of fault and sequence network in detail.
Sample calculation-for-differential-relaysRoberto Costa
The document provides calculations for setting differential relays on a power transformer. It includes calculations of currents at different transformer taps to determine relay settings that avoid unwanted operation during tap changes. Currents are calculated for the high voltage side, low voltage side and on the relay at extremes of +/- 10% taps. The differential current at each tap is compared to the relay operating current to set the pickup value to avoid operation during tap changes while maintaining protection.
The document is a product brochure for TVR-Line voltage regulators manufactured by Zhejiang Farady Electric Co., Ltd. It summarizes the company profile and provides details on the voltage regulators' applications, working principles, technical specifications, structure, functions, installation examples, and answers to frequently asked questions. The voltage regulators can automatically adjust output voltage to keep it stable within ±10-30% of the rated voltage and improve power quality and supply reliability for distribution lines.
This document provides an overview of the key components in a 132kV substation, including:
- Lightning arresters that divert high voltage waves to earth for protection.
- Coupling capacitors that allow communication over power lines.
- Wave traps that offer low impedance to carrier frequencies for communication.
- Current and potential transformers that reduce currents and voltages for safe measurement and protection.
- Circuit breakers, transformers, and busbars that distribute power throughout the substation.
- Control rooms that monitor and control the substation operations.
- Earthing systems that provide grounding for safety.
This document discusses low voltage switchgear, including definitions and examples. It describes common types of low voltage switchgear like air circuit breakers, MCCBs, contactors, relays, and fuses. It provides information on their ratings and standards. The document focuses on contactors, explaining their operation, applications, selection parameters, and utilization categories. It also discusses motor protection concepts and thermal overload relays, including their operation and selection parameters.
There is an optimal transmission voltage for electricity that balances various transmission costs. While increasing voltage reduces the cost of conductors, it also increases the costs of insulating equipment, transformers, and support structures. The document discusses how transmission voltage, power transmitted, and transmission line length affect the economic transmission voltage. A graph of total transmission cost versus voltage shows the minimum point as the optimal voltage.
This document discusses five types of transformer testing: open circuit testing, short circuit testing, load testing of single phase transformers, Sumpner's testing, and polarity testing. Open circuit testing determines losses with one winding open. Short circuit testing determines copper losses at full load. Load testing determines efficiency and regulation characteristics. Sumpner's testing uses two identical transformers to determine iron and copper losses. Polarity testing determines if the transformer windings produce voltages that are additive or subtractive.
La Navidad es una fecha especial para reunirse con seres queridos, compartir felicidad y cantar villancicos. Se decora el árbol con luces y adornos como símbolo navideño y se disfrutan dulces como los polvorones, además de creer en Papá Noel que reparte regalos a los niños buenos.
Module 2 ee369 KTU syllabus-high voltage ac generation,resonant circuitsAsha Anu Kurian
Generation of high AC voltages-Testing transformer – single unit testing transformer, cascaded transformer – equivalent circuit of cascaded transformer – generation of high frequency AC voltages- series resonance circuit – resonant transformer – voltage regulation.
This document discusses testing of transformers. It provides an overview of transformers and their functions in transmission and distribution of electrical energy. It then describes various routine, type, and special tests performed on transformers, including winding resistance measurement, voltage ratio measurement, no-load loss measurement, load loss measurement, insulation resistance measurement, and dielectric tests. It also discusses short-circuit testing procedures and criteria. Temperature rise testing and its limits are also summarized.
Electrical energy is generated at power stations and transmitted through a network with two parts: transmission and distribution. The transmission system uses high voltage power lines supported by steel transmission towers ranging from 15-55 meters tall. There are different types of poles that can support power lines for the distribution system, including wooden poles, concrete poles, steel tubular poles, and steel towers, with factors like cost, strength, and maintenance considered for the appropriate selection. Safety protocols must be followed when working with transmission towers.
This document discusses underground cables for electrical power distribution. It covers the construction of cables including conductors, insulation, metallic sheathing, bedding, armouring and serving. Common insulating materials like XLPE are described. Cables are classified based on voltage level. Methods of laying cables underground include direct laying, draw-in systems and solid systems. Potential cable faults include open circuits, short circuits and earth faults. Underground cables have advantages over overhead systems like better appearance, lower maintenance needs and fewer faults, but the installation costs are higher.
OPEN CIRCUIT AND SHORT CIRCUIT TEST OF SINGLE PHASE TRANSFORMER|DAY7| BASIC E...Prasant Kumar
#Open_circuit_short_circuit_test of single phase transformer
#OC_SC_TEST OF TRANSFORMER
#Core loss and copper loss test of single phase transformer.
After going through this session you will be able to answer the following questions.
• Which parameters are obtained from O.C test?
• Which parameters are obtained from S.C test?
• What percentage of rated voltage is needed to be applied to carry out O.C test?
• What percentage of rated voltage is needed to be applied to carry out S.C test?
• From which side of a large transformer, would you like to carry out O.C test?
• From which side of a large transformer, would you like to carry out S.C test?
Aim of conduction transformer Open Circuit & Short Circuit test
To predict its performance without actual loading.
Determination of equivalent circuit parameters
To determine parameters of a transformer like voltage regulation and efficiency
Open circuit test is carried out to determine core loss and shunt parameters.
Open circuit test is carried out at rated voltage and rated frequency . During this test, rated flux is produced in the core .
To carry out open circuit test rated voltage at rated frequency is applied to LV side of the transformer and HV side is left opened as shown in the circuit diagram.
HV side is left opened because it is easier to arrange rated voltage supply on LV side because no load current which is quite small about 2 to 5% of the rated current.
Metering instrument connected at LV side are economical & always safer to work.
The voltmeter, ammeter and the wattmeter readings are taken and suppose they are Voc , Io and Poc respectively.
Strictly speaking the wattmeter will record the core loss as well as the LV winding copper loss. But the winding copper loss is very small compared to the core loss as the flux in the core is rated.
1. Transformers have on-load and off-load tap changers that allow adjusting the transformer's output voltage without interrupting the load current. On-load tap changers can adjust voltage while energized using fast-acting switches, while off-load tap changers require de-energizing the transformer to change taps.
2. On-load tap changers are commonly used in power generation and distribution transformers to control voltage as load and line conditions vary. They monitor voltage and raise or lower taps using an automatic voltage regulator. Off-load tap changers are typically used in solar and wind projects where the generator voltage is low-voltage.
3. The on-load tap changer maintains uninterrupted
Reluctance is the opposition to magnetic flux in a magnetic circuit, analogous to resistance in an electric circuit. Reluctance is caused by properties of the magnetic material like length, cross-sectional area, and permeability. The reluctance of a non-uniform magnetic circuit is calculated by adding the reluctances of each uniform section. An air gap is often included to reduce saturation by increasing reluctance.
Inductance is the ability of a circuit to store energy in a magnetic field. It is caused by the self-inductance within a coil or mutual inductance between two linked coils. Inductors use this property to oppose changes in current flow. The standard unit for inductance is the henry.
HVDC systems remain the best option for long-distance bulk power transmission and connecting asynchronous grids. They allow for more economical and environmentally friendly power transmission compared to HVAC systems in these conventional applications. However, advances in technology, deregulation of electricity markets, and environmental protection efforts are increasing the viability of HVDC systems for additional situations where high voltage AC transmission was previously preferred.
This document provides information about transformers and their components. It discusses how transformers work using electromagnetic induction to transfer energy between circuits without a direct electrical connection. The key components of a transformer are described, including the magnetic core made of silicon steel, the windings, insulation and cooling using mineral oil. Ideal transformer theory is also covered, explaining voltage and current ratios based on winding turns.
The document discusses lightning protection for wind turbine blades. It defines a wind turbine as a device that converts wind's kinetic energy to electrical power. There are two main types: horizontal axis and vertical axis turbines. Lightning is a sudden electrostatic discharge during a storm that can generate direct thermal effects at the strike point. The blades are one of the most vulnerable parts and research has analyzed the damage mechanisms from lightning strikes. Installation of lightning arresters at blade tips can effectively intercept lightning strikes.
Case Study - Importance of Relay Coordination in Process IndustriesSystem Protection
A cement plant experienced unexpected tripping of the entire plant twice in three months due to poor relay coordination. An investigation found that load had been added to a motor control center without properly adjusting the relay settings. Specifically, a 75kW high pressure pump and compressor loads totaling 217kW were added. This caused the starting current of a 315kW crusher motor to exceed threshold levels after it restarted, tripping the entire plant. The outages cost the plant over 500 tons of lost cement production and 2.5-2.8 million rupees in losses each time. The case study highlights the importance of coordinating relay and protection settings whenever modifications are made to the electrical distribution system.
Main component parts of the overhead line
The most effective method of providing protection to transmission lines against direct lightning strokes is by use of overhead ground wires as shown in Fig 6. For simplicity, one ground wire and one line conductor are shown. The ground wires are placed above the line conductors at such positions that practically all lightning strokes are intercepted by them (i.
e. ground wires). The ground wires are grounded at each tower or pole through a low resistance as possible. Due to their proper location, the ground wires will take up all the lightning strokes instead of allowing them to line conductors. The degree of protection provided by the ground wires depends upon the footing resistance of the tower.
This power point presentation provides an overview of fault analysis and sequence networks in power systems. It defines different types of faults including open circuit faults, short circuit faults, symmetrical faults, and unsymmetrical faults. Symmetrical faults involve all three phases and remain balanced, while unsymmetrical faults involve one or two phases. Sequence networks, including positive, negative, and zero sequence networks are used for fault analysis. The presentation describes each type of fault and sequence network in detail.
Sample calculation-for-differential-relaysRoberto Costa
The document provides calculations for setting differential relays on a power transformer. It includes calculations of currents at different transformer taps to determine relay settings that avoid unwanted operation during tap changes. Currents are calculated for the high voltage side, low voltage side and on the relay at extremes of +/- 10% taps. The differential current at each tap is compared to the relay operating current to set the pickup value to avoid operation during tap changes while maintaining protection.
The document is a product brochure for TVR-Line voltage regulators manufactured by Zhejiang Farady Electric Co., Ltd. It summarizes the company profile and provides details on the voltage regulators' applications, working principles, technical specifications, structure, functions, installation examples, and answers to frequently asked questions. The voltage regulators can automatically adjust output voltage to keep it stable within ±10-30% of the rated voltage and improve power quality and supply reliability for distribution lines.
This document provides an overview of the key components in a 132kV substation, including:
- Lightning arresters that divert high voltage waves to earth for protection.
- Coupling capacitors that allow communication over power lines.
- Wave traps that offer low impedance to carrier frequencies for communication.
- Current and potential transformers that reduce currents and voltages for safe measurement and protection.
- Circuit breakers, transformers, and busbars that distribute power throughout the substation.
- Control rooms that monitor and control the substation operations.
- Earthing systems that provide grounding for safety.
This document discusses low voltage switchgear, including definitions and examples. It describes common types of low voltage switchgear like air circuit breakers, MCCBs, contactors, relays, and fuses. It provides information on their ratings and standards. The document focuses on contactors, explaining their operation, applications, selection parameters, and utilization categories. It also discusses motor protection concepts and thermal overload relays, including their operation and selection parameters.
There is an optimal transmission voltage for electricity that balances various transmission costs. While increasing voltage reduces the cost of conductors, it also increases the costs of insulating equipment, transformers, and support structures. The document discusses how transmission voltage, power transmitted, and transmission line length affect the economic transmission voltage. A graph of total transmission cost versus voltage shows the minimum point as the optimal voltage.
This document discusses five types of transformer testing: open circuit testing, short circuit testing, load testing of single phase transformers, Sumpner's testing, and polarity testing. Open circuit testing determines losses with one winding open. Short circuit testing determines copper losses at full load. Load testing determines efficiency and regulation characteristics. Sumpner's testing uses two identical transformers to determine iron and copper losses. Polarity testing determines if the transformer windings produce voltages that are additive or subtractive.
La Navidad es una fecha especial para reunirse con seres queridos, compartir felicidad y cantar villancicos. Se decora el árbol con luces y adornos como símbolo navideño y se disfrutan dulces como los polvorones, además de creer en Papá Noel que reparte regalos a los niños buenos.
Este documento describe cómo crear y utilizar blogs en educación. Explica la definición de blog, sus posibilidades y aplicaciones educativas. Luego detalla los pasos para crear un blog en Blogger, incluyendo alta, acceso, configuración y elementos. Finalmente incluye una bibliografía de recursos sobre blogs.
El documento describe un hogar transitorio en Cochabamba, Bolivia que alberga a 25 niños menores de 5 años. Los niños viven en el hogar debido al abandono o problemas de sus padres como drogas y alcohol. El hogar es apoyado por "mamás" que los cuidan pero no pueden pagar su comida. Los niños quieren crecer sanos tomando leche, pero es muy cara. Han buscado una vaca para su leche sin éxito y piden ayuda a la audiencia para comprar leche para los próximos dos años.
Présentation permettant de se rendre compte de l'évolution des personnes actives occupées en Suisse selon les 3 premiers trimestres 2014.
Sont considérées comme actives occupées selon le concept intérieur, les personnes travaillant dans le pays, qu'elles résident ou non dans ce dernier.
El documento habla sobre varios temas relacionados a Internet como la Internet profunda, PageRank, WHOIS, dominios y búsquedas avanzadas. Explica conceptos como la Internet profunda o invisible, PageRank y su algoritmo, el protocolo WHOIS y tipos de dominios como territoriales y genéricos. También cubre criterios para realizar búsquedas avanzadas y filtrar resultados en motores de búsqueda.
Este documento describe la importancia y el uso de las herramientas web 2.0 para la gestión del conocimiento. Explica que debido a la pandemia, las clases presenciales han sido reemplazadas por material de aprendizaje como una guía didáctica, un CD multimedia y trabajo a distancia. El CD contiene presentaciones de PowerPoint y archivos PDF para reforzar el aprendizaje. Además, detalla que el correo electrónico se ha convertido en el medio más eficaz para comunicarse a distancia y que Google Docs permite realizar
Este documento presenta la novela "Las aventuras matemáticas de Daniel", la cual describe las experiencias de un estudiante de enseñanza media con la asignatura de matemáticas. A través de actividades creativas e innovadoras, el profesor implementa un enfoque práctico y vivencial para romper con los esquemas tradicionales de enseñanza. El objetivo es motivar a los estudiantes haciendo relevante las matemáticas en la vida cotidiana y demostrando su belleza. La novela propone un modelo didáct
El documento describe varias situaciones en las que Dios puede estar presente de forma sutil en la vida de las personas, como el deseo de hacer algo bueno por alguien querido, sentir tristeza a pesar de tener a alguien cercano, recibir algo maravilloso que no se pidió, encontrar soluciones inesperadas a problemas, o sentir paz interior en medio de la tristeza. El mensaje invita a dejar que Dios toque el corazón y a compartir su inmenso amor con todos, ya sean amigos, familiares o desconocidos.
Este documento argumenta que la sociedad ha ido alejándose de los valores y enseñanzas religiosas a través de los años al permitir que se saquen la Biblia y la oración de las escuelas y al aprobar cosas como el aborto y la pornografía. Sugiere que esto ha llevado a una pérdida de moral y una incapacidad de los jóvenes para distinguir el bien del mal, lo que puede explicar problemas como tiroteos en escuelas. Concluye diciendo que debemos reconsiderar las consecuencias de haber "dicho que estaba
El Grupo Parlamentario Socialista propone la creación de una ponencia de estudio para evaluar la aplicación de la ley de separación y divorcio de 2005, en especial sobre la custodia y guarda compartida. La ponencia escucharía a asociaciones de padres, jueces, psicólogos y trabajadores sociales durante un plazo inicial de cuatro meses para mejorar la legislación en beneficio de los niños. El objetivo es fomentar la responsabilidad parental compartida pero establecer criterios claros cuando no hay acuerdo entre los progenitores.
Este documento presenta información sobre la ONG Amigos de Mali. La ONG trabaja en Mali, uno de los países más pobres del mundo, para apoyar proyectos de agua y saneamiento, agricultura, salud, educación y enfoque de género. El proyecto elegido por los estudiantes se centra en proporcionar becas para la educación secundaria y profesional de 71 estudiantes en Mali. La ONG está dispuesta a recibir una donación de los estudiantes para continuar financiando este proyecto de becas.
Este documento trata sobre electrónica digital. Explica que la electrónica estudia el comportamiento de los electrones y cómo construir circuitos para controlar el flujo de electrones. También describe cómo los circuitos digitales representan números binarios usando diferentes voltajes para los bits 1 y 0, y cómo estos circuitos pueden tener múltiples entradas y salidas.
El documento habla sobre la integración de las TIC en las teorías de aprendizaje de Bruner y Piaget. Según Bruner, el aprendizaje por descubrimiento favorece el desarrollo mental ya que es importante que los estudiantes resuelvan problemas por sí mismos. Los profesores deben proporcionar situaciones problemáticas y recursos como software educativos y blogs para estimular el aprendizaje. Por su parte, Piaget explica que el aprendizaje se da a través de la asimilación y acomodación a través de
Este libro trata de la vida de Juan Manuel Montilla, conocido como "El Langui", quien nació con parálisis cerebral. El libro consta de 16 capítulos que exploran emociones y experiencias como la amistad, el miedo, la soledad y el amor. A lo largo del libro, el autor incluye rimas de hip hop en las que expresa lo que quiere decir en cada capítulo. El libro ofrece consejos para ver cada sentimiento desde la perspectiva del autor y mejorarse a uno mismo.
Este documento proporciona lineamientos para crear diferentes tipos de gráficos con el objetivo de resumir y comparar datos de manera efectiva. Incluye recomendaciones para graficar tendencias de una o más series de datos a lo largo del tiempo, comparar valores numéricos, destacar valores atípicos y describir comportamientos entre categorías. En todos los casos enfatiza la importancia de presentar los datos de forma ordenada y con un comportamiento consistente para facilitar la comprensión de la información.
Découvrez votre LIGATUREUSE la plus performante du marché.
Les ligatureuses MAX sont reconnues sur les chantiers au près des maçons, des éléctriciens et des plombier.
Avec les rouleaux de fil doublé les LIGATUREUSE Twintier sont l'atout pour le ferraillage dans le monde du BTP
Solutions de manutention des poudres
Manutention des pulvérulents
Equipement de manutention
Manutention poudre
Manutention poudres
Manutention produit vrac
Manutention vracs
Process poudre
Technologies manutention poudre
Process industriels traitant des poudres
Acome connector data sheets - Acome liitinesitteetAerial Oy
Acome connector data sheets
C0001A 7/16 female for HPL 50-1/2 inch F cable
C0002A 7/16 female for HPL 50-7/8 inch F cable
C0003A 7/16 female for HPL 50-1 1/4 inch F cable
C0004A 7/16 female for HPL 50-1 5/8 inch F cable
C0005A 7/16 male for HPL 50-1/2 inch SF cable
C0006A 7/16 male for HPL 50-1/2 inch F cable
C0031A 7/16 male 90 deg. for HPL 50-1/2 inch SF cable
C0032A 7/16 female for HPL 50-1/2 inch SF cable
C0042A N male for HPL 50-1/2 inch SF cable
C0043A N male 90 deg. for HPL 50-1/2 inch SF cable
C0044A N female for HPL 50-1/2 inch SF cable
C0050A 7/16 male 90 deg. for HPL 50-1/2 F cable
C0055A 7/16 male for HPL 50-7/8 inch F cable
C0059A N female for HPL 50-1/2 inch F cable
C0061A N male for HPL 50-1/2 inch F cable
C0069A N female for HPL 50-7/8 inch F cable
C0070A N male for HPL 50-7/8 inch F cable
Revo job - Centrale aspirante Sistem - tertiaire/professionnelHomexity
REVO Job est la nouvelle centrale aspirante Sistem Air conçue des usages intensifs dans le secteur tertiaire/professionnel. Simplicité, fiabilité et puissance d’aspiration représentent les caractéristiques de pointe de ce produit.
Electrodistributeur 5 orifices - Catalogue SMC New SQ1000/2000SMC Pneumatique
SMC renouvelle sa série d'électrodistributeurs SQ1000/2000 pour parfaitement s'adapter aux critères environnementaux mondiaux tels qu'une faible consommation électrique et une grande facilité d'entretien.
- Réduction de la consommation de 60% par rapport au modèle actuel : 0,4W en standard contre 1W avec la version antérieure.
- Distributeur montable à l'aide d'une simple vis
- Remplacement facilité des raccords instantanés à attaches
- Le sens d'entrée du connecteur peut être modifié par une simple pression
- En option : clapet antiretour intégré, pour éliminer les problèmes de contre-pression lors de la commande d'un vérin simple ou l'utilisation d'un électrodistributeur de centre d'échappement
- Une large gamme d'embases précâblées est disponible
- Conformité CE
Alternative - Complément au Tramway et 3ème lien de la ville de Québec Daniel Bedard
An update of this presentation has been done with Slide 16 that has been updated and 17 has been added, only.
Cette présentation a été ajournée avec la diapo 16 qui a été modifié et la 17 qui a été ajouté.
Voir ici
https://www.slideshare.net/slideshow/alternative-au-tramway-de-la-ville-de-quebec-rev1-sum-pdf/269691794
CDPQ Infra dévoile un plan de mobilité de 15 G$ sur 15 ans pour la région de Québec. Une alternative plus économique et rapide, ne serait-elle pas posssible?
- Valoriser les infrastructures ferroviaires du CN, en créant un Réseau Express Métropolitain (REM) plutôt qu'un nouveau tramway ou une combinaison des 2.
- Optimiser l'utilisation des rails pour un transport combiné des marchandises et des personnes, en accordant une priorité aux déplacements des personnes aux heures de pointes.
- Intégrer un téléphérique transrives comme 3ème lien urbain dédiés aux piétons et cyclistes avec correspondance avec le REM.
- Le 3 ème lien routier est repensé en intégrant un tunnel routier qui se prolonge avec le nouveau pont de l'Île d'Orléans et quelques réaménagemet de ses chausées.
https://www.linkedin.com/in/bedarddaniel/
English:
CDPQ Infra unveils a $15 billion, 15-year mobility plan for the Quebec region. Wouldn't a more economical and faster alternative be possible?
Leverage CN's railway infrastructure by creating a Metropolitan Express Network (REM) instead of a new tramway or a combination of both.
Optimize the use of rails for combined freight and passenger transport, giving priority to passenger travel during peak hours.
Integrate a cross-river cable car as a third urban link dedicated to pedestrians and cyclists, with connections to the REM.
Rethink the third road link by integrating a road tunnel that extends with the new Île d'Orléans bridge and some reconfiguration of its lanes.
https://www.linkedin.com/in/bedarddaniel/
5. Courroies Industrielles - Rapport détaillé
Design Flex® Pro de Gates Corporation
Dest. Projet : Fourni par : v vb
f
dd
dd, Liège (fr) 4950
Belgique
info@tuningbox.com
003280679497 Tél.
Application: Projet n° 1
ENTREE
Info transmission
Rapport vitesse: 1.36 Réd.
Puiss. moteur : 25 kW
Facteur service : 1.6
Puiss. prévue: 40 kW
Entraxe : 160 mm +/-20%
Motrice Réceptrice
Vitesse rotation : 3400.0 2500.0 +4%/-4%
Vitesse maxi à la circonférence: 33 m/s 33 m/s
Moyeux vérifiés : TL
Courroies vérifiées : Poly Chain Carbon
TRANSM. SELECT.
Type courroie : Poly Chain Carbon - 8M
Rapport vitesse: 1.39 Réd.
Vit. Réceptrice: 2448.0
Puiss. nominale : 40.75 kW
Charge /Palier : 1966 N
Entraxe : 187.2 mm
Plage installation/tension 152.1 mm à 187.9 mm
Courroie Motrice Réceptrice
Réf. pièce : 8MGTC-720-21 8M36S21 8M50S21
Réf. produit : 9274-01090
Largeur au sommet : -- 42.00 mm 42.00 mm
Poids : 71 g 0 g 0 g
Vitesse Courroie : 16.3 m/s 16.0 m/s 16.1 m/s
Vitesse rotation : 1359.9 3400.0 2448.0
Réf. moyeu : -- 1610 2012
Alésage : -- 12.7 mm - 42.0 mm 14 mm - 50.8 mm
Diamètre primitif : -- 91.67 mm 127.3 mm
TENSION
Courroie neuve Courroie usagée
Déflexion des stries/brins 2.91 mm 2.91 mm
Effort de déflexion sur stries/brins 74 à 80 N 56 à 62 N
Tension Sonic
Fréquence de la courroie : 277 à 290 Hz 237 à 251 Hz
Données Sonic 505C/507C Poids : 4.7 g/m,Largeur : 21 mm/#R, Long. Brin : 186 mm
Si vous prévoyez de réinstaller des courroies
usagées, mesurez et enregistrez la tension
avant le démontage et réinstallez les courroies
à la valeur de tension enregistrée.
NOTES
- Les solutions Gates Design Flex Pro ne sont que valable pour des produits Gates
- Les produits GATES ne doivent en aucun cas être utilisés sur des applications où la défaillance de l'équipement entraîné pourrait
entraîner des dommages corporels ou la mort. Ceci inclus l'utilisation en aéronautique, entraînement d'hélices, entraînement de
rotors ou commande d'accessoires de vols.
25/11/2010 13:33 Page 1 sur 1 1.65/1.48/1.52/ Europe